Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Rejected-Technical 202 1ST FLOOR VIVEKANAND PURI MALKAGANJ SARAI ROHILLA NORTH DELHI DELHI 110007 UDYAM DL 01 0065084 | NORTH DELHI | DELHI | 110007 | Rejected-Technical Due to FDR is not submit |
| 4 | Rejected-Technical 1008 A PREMIER ENGINEERING COMPANY PURVI RITHANI MEERUT DELHI ROAD MEERUT UTTAR PRADESH 250103 INDIA | MEERUT | UTTAR PRADESH | 250103 | Rejected-Technical Due to FDR is not submit |
Tender Value
Refer Docs
EMD Value
₹17,900
Closing Date
19 Sept 2023, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER (EM) M-10
GREATER KAILASH, PART-I, NEW DELHI
Providing/ Fixing of lighting system at JE Store and Newly constructed sewer store Chirag Delhi ward under Greater Kaialsh Constituency (AC-50)
2023_DJB_247396_22
NIT No. 4/EE(EM)M-10/(23-24)
Open Tender
Electrical Work/ Equipment
Works
30 days
EXECUTIVE ENGINEER (EM) M-10
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Delhi Jal Board
₹17,900
Yes
8 Nov 2023
12 Sept 2023
19 Sept 2023
12 Sept 2023
19 Sept 2023
12 Sept 2023
S/o 20W LED Batten light. DJB SOR2022 item code-19.1.2
S/o 70W LED street light. DJB SOR2022 item code-19.10.6
S/o LED fitting and frame 600mm x 600 mm (N.S) with HET diffuser, Recess Mounting 36 watt. DJB SOR2022 item code-19.9.2
S/o 450 mm size Exhaust Fan. DJB SOR2022 item code-20.2.3
S/o 1200 mm size Ceiling Fan. DJB SOR2022 item code-20.1.2
S/o PVC/XLPE insulated (heavy Duty) Electrical Cable for working voltage up to and including 1100 volts to IS:1554 (part-I) 1988/7098 (part-I) with aluminum conductor- ISI marked power cable- aluminum for size 10 Sq.mm 2 core Armored cable. Make: Any DJB Approved make
Wiring for light point / fan point/ exhaust fan / call bell point / with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. DSR (E&M)2022 1.10.3 Group C
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire DSR (E&M)2022 1.14.2
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire DSR (E&M)2022 1.14.3
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.5/6 A switch DSR (E&M)2022 1.23.1
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.3 pin 5/6 A socket outlet DSR (E&M)2022 1.23.4
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.15/16 A switch DSR (E&M)2022 1.23.3
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.6 pin 15/16 A socket outlet DSR (E&M)2022 1.23.5
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. DSR (E&M)2022 1.25
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. DSR (E&M)2022 1.44
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required. DSR (E&M)2022 7.7.1
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door DSR (E&M)2022 2.3.3
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole DSR (E&M)2022 2.10.1
Supplying and fixing 63 A rating, double pole 240 isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole DSR (E&M)2022 2.12.2
Supplying and fixing of 32 mm dia X 2.00 meter long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 Nos. 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer andfinish paint etc. as required. DSR (E&M)2022 12.34
Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc.with charcoal/ coke and salt as required DSR (E&M)2022.5.2
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required DSR (E&M)2022.5.16
Raj Engineering Co.
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .