IWD IIT Kanpur
SITC of 7 x 2.0 TR and 5 x 1.5 TR split ACs with associated works at the Nursery A B and C prep A and B KG A and B and office of the Kislay School building at IIT Kanpur
2026_IITK_911067_1
09/AC/SE/2026/57
Open Tender
Electrical Works
60 days
IIT Kanpur
As per tender
2 documents required · 2 mandatory
₹0
₹14,472
1 Jun 2026
1 Jun 2026
9 Jun 2026
1 Jun 2026
8 Jun 2026
1 Jun 2026
1 Jun 2026 - 5 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). | ||||||
| 1.1 | Inverter Type - Cooling Only | - | - | - | - | item3 |
| 1.2 | 1.5 TR with 5 star BEE rating | 5 | Nos. | 43,539 | ₹2,17,695 | item4 |
| 1.3 | 2.0 TR with 5 star BEE rating | 7 | Nos. | 57,396 | ₹4,01,772 | item5 |
| 2 | Providing & fixing of additional refrigerant copper piping (6.3 mm/15.88mm) or (6.3 mm/12.7 mm) suitable for suction & discharge line i/c additional refrigerant R-32 /R-410 A top-up as required with 6/9 mm XLPE/Nitrile insulation with PVC tape on surface /recessed with clamps, screws etc from indoor tooudtdoor units as standard specifications complete as required | 30 | Mtr | 1,416 | ₹42,480 | item6 |
| 3Providing & fixing Unplasticized Polyvinyl Chloride (uPVC) pipes, having thermal stability for cold water supply, including all UPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer In Charge. Internal Work - Exposed on Wall | ||||||
| 3.2 | 25 mm | 20 | Mtr | 212 | ₹4,240 | item8 |
| 4 | Providing & fixing of suitable size and type ready made iron wall/floor mounting bracket stand duly painted for ODU w/o canopy | 7 | Nos | 1,063 | ₹7,441 | item9 |
| 5 | Providing & fixing of suitable size and type ready made iron wall/floor mounting bracket stand duly painted for ODU i/c canopy made 25 x 3 mm angle frame with fibre Aluminium sheet with VI pad, Nut-bolt, washers etc for outdoor unit complete as required. | 5 | Nos | 2,006 | ₹10,030 | item10 |
| 6Suplly, laying, testing and Commissioning of approved make FRLS PVC/ XLPE insulated Power / Control copper cable of on surface / recessed complete as required. | ||||||