| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.4 LAccepted-AOC | L1 | Accepted-AOC L1 bidder lowest | |
| 2 | L2₹36.5 L+₹54,277.20 (1.51%)Rejected-Finance SHOP NO 13 45 FEET ROAD BHARAT COLONY FARIDABAD HARYANA 121014 | FARIDABAD | HARYANA | 121014 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹47.8 L+₹11.9 L (33.0%)Rejected-Finance | L3 | Rejected-Finance Other than L1 |
Tender Value
₹48.9 L
EMD Value
₹97,880
Closing Date
21 Jan 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (West) Jabalpur
Garrison Engineer (West) Jabalpur Supply Marg Post Box No. 54 Jabalpur Cantt-482001 (MP)
REPAIR AND MAINT OF SUMMER COOLING APPLIANCES UNDER GE (WEST) JABALPUR
2024_MES_690167_1
8836/E8
Open Tender
Civil Works
Item Rate
180 days
GE (West) Jabalpur
As per tender documents
6 documents required · 6 mandatory
₹500
GE (West) Jabalpur
₹97,880
28 Feb 2025
24 Dec 2024
23 Jan 2025
26 Dec 2024
21 Jan 2025
7 Jan 2025
26 Dec 2024 - 2 Jan 2025
Amount
Material & Labour for replacement of old / Unserveciable compressor with new sealed unit compressor company fabricated with all accessories such as starter, running capacitor & over load wiring of existing makes/model for the water cooler, Deep Freezer & Refrigerator including first fill of refrigerant gas, brazing jointing, leak proof testing & commissioning complete all as specified and as directed for the following :-
(a) Compressor suitable for Water cooler capacity 60/120 Litre Make : Godrej / Voltas / Bluestar
(b) Compressor suitable for Water cooler capacity 150/150 Litre Make : Godrej/ Voltas/ Bluestar
(c) Compressor suitable for Water cooler capacity 40/80 Litre Make : Godrej/ Voltas / Bluestar
(d) Compressor suitable for Deep Freezer capacity 320 Litre Make : Godrej/ Voltas / Bluestar
(e ) Compressor suitable for refrigerator capacity 165 Litre Make Godrej /Tecumesh / LG
(f ) Compressor suitable for refrigerator capacity 280 Litre Make Godrej /Tecumesh /LG
(g ) Compressor suitable for refrigerator capacity 310 Litre Make Godrej /Tecumesh /LG
Material & Labour for replacement of Old Unserviceable compressor with new sealed unit compressor, company fabricated with all accessories such as starting running capacitor & over load with wiring of existing Make/model for the window AC and Split AC including first fill of refrigerant gas, brazing jointing, leak proof testing & commissioning for the following :- Note : (i) Make of compressor should be same as per make of equipment i.e. AC, Water cooler, Deepfreezer and Refrigerators. (ii) Rate quoted by contractor deems to be included for replacement warranty of 5 Yrs for compressor of all items excluding AC and 10 Year for AC. Make for Sl Item No 10 to 15 : Blustar/Samsung/Voltas/LG
(a) Compressor hermatic type Suitable for 1.0 Ton AC window type
(b) Compressor hermatic type Suitable for 1.5 Ton AC window type
(c) Compressor hermatic type Suitable for 2.0 Ton AC window type
(d) Compressor rotary screw type Suitable for 1.5 Ton AC split type
(e) Compressor rotary screw type Suitable for 2.0 Ton AC split type
(f) Compressor inbuilt invertor type Suitable for 1.5 Ton AC split type
Material & Labour for Rewinding of fan motor of water cooler, desert cooler and AC with super enameled copper winding wire of existing gauge including insulation, warnishing etc, and replacement of worn out bushes, bearings, shafts, nuts, bolts and washers includind greasing, oiling, reassembling and testig the motor complete all as specified and directed for the following capacities:-
(a) 1/7 HP Suitable for Desert cooler
(b) 1/10 HP and 1/35 HP Suitable for water cooler
(c ) 1/4 HP and 1/6 HP Suitable for AC any type
Replacement new PCB (printed circuit board ) units as existing model/make for split AC 1.5/2 Ton capacity complete all as specified and as directed . Make:Blue star/Voltas/LG/Samsung
Replacement Old/UNSV with new water lifting pump suitable for Desert cooler of 1/20 Hp, 240 volts, 50 Hz, 12 watts, 1.5 mtr head capacity complete all as specified and as directed .Make:Crompton /Khaitan/Kenstar
S & F PVC switch box including two switch & indicater of Plaza Make for Desert cooler including taking down old switch box complete all as specified and as directed
S & F five speed regulator for Desert cooler 240 volts 50 Hz, single phase, including taking down old/unservicable regulator complete any make and any size of Make : PLAZA/KINJAL/ANCHOR
S & F Knobs for window AC , including taking down old unserviceable knobs complete any make and any size, complete all as specified and as directed
S & F AC contactor MP-11 suitable for window AC /split AC 1.5/ 2 TR ,240 volts 50 Hz, single phase including taking down old AC contactor MP-11 complete all as specified and as directed .
S&F in replacement Desert cooler water tank suitable for Desert cooler (as per existing size) made out of 22 gauge GI sheet made to shape including complete all as specified and as directed .
S&F in replacement water cooler float valve PVC ISI mark size 15 mm, with ball rod for water cooler any capacity/make complete all as specified and directed . Mark : Prayag or equivalent as approved by Engineer in Charge.
S & F in replacement Suction valve/Liquid valve of size 1/2" & 1/4" along with dead nut complete suitable for split AC cap 1.5/2 Ton out door unit complete all as specified and directed by Engr-in-Charge.
S&F Lamp/bulb Suitable for Refrigerantor of Capacity 310Ltrs/280ltrs/165 ltrs, (thread or pin type),15 volts, 240 volts 50 Hz, single phase including taking down old Lamp complete all as specified and as directed .
S&F door switch suitable for refrigerator 240 volts 50 Hz, single phase suitable for existing make of refrigerator including taking down old Lamp complete all as specified and directed .
S & F in replacement GI tubing 15 mm dia medium grade with all fittings and fixtures such as elbow,tee,union ,socket etc complete all as specified and directed by Engr-in-Charge.
S & F in replacement PVC tubing 15 mm dia heavy duty fixed on wall/floor with suitable clamps with all PVC fittings and fixtures such as elbow,tee,union ,socket etc ISI mark Complete all as specified and directed by Engr-in-Charge.
M&L for Preparation of surfaces and applying two coat of synthetic enamel spray painting on metal surface (inner/outer) including writing SM No/MES No with paint to following items complete all as specified and directed .
(a) Water cooler of any make and size
(b) Desert cooler of any make and size
(c) Refrigerator cap 165 ltrs
(d) Refrigerator cap 280 and 310 ltrs
(e) Deep Freezer of any make and size
Replacement of Old/UNSV with new wood/wool pads of required size for Desert cooler any make including complete all as specified and directed .
Replacement of Old/damaged with new front Grill made out of 22 gauge GI sheet suitable for Desert cooler any make/size complete all as specified and directed .
Repair/replacement of damaged body of Desert cooler, water cooler,Deep Freezer with 1 mm thick MS sheet any make complete all as specified and directed .
S & F in replacement of old/UNSV fan motor, single phase, 230 volt ,50 Hz ,1/7 HP with blade arm 18" sweep size suitable for Desert cooler, complete all as specified and directed. Make: Khaitan/Champion/Jyoti
S & F in Replacement of defective / damaged transformer of voltage stabilizer complete all as specified and as directed of following capacity:-
S & F in Replacement of volt meter range 0 to 300 volts, flush type square or circular for voltage stabilizer complete all as specified and directed.
Supplying and fixing in Replacement of liner (cold gold model) for refrigaretor capacity 165 ltr complete all as specified and directed.
Ditto all as per above items but capacity 310 Ltr
Replacement of old/UNSV fan motar 230 volt ,50 Hz for following items complete all as specified and directed . Make: Crompton
(a) 1/10 HP of Water cooler cap 150/150 ltr
(b) 1/35HP of Water cooler cap 60/120 ltr
(c) 1/20 HP suitable size of water cooler cap 40/80 ltr
(d ) 1/20 HP for deep freezer cap 310 ltr)
(e) 1/4 and 1/6 HP suitable for AC window type and split type
Re-filling of Refrigerent gas Non CFC R 32 of Window AC & Split AC of capacity 1.5 Tr including breezing, jointing,leak testing ,commissioning,taking down and refixing complete all as specified and as directed .
Re-filling of Refrigerent gas Non CFC R 22 of Window AC & Split AC of capacity 1.5 Tr including breezing, jointing,leak testing ,commissioning,taking down and refixing complete all as specified and as directed .
Re-filling of Refrigerant gas Non CFC (R-134 A) of Refregirator, water Cooler and Deep Freezer of any capacity including brazing, jointing,leak testing ,commissioning,taking down and refixing complete all as specified and directed .
Replacememt of Old/UNSV submain wiring with two run of PVC insulated cable of size 4 sqmm copper conductor (Multi strand) drawing into existing surfaces/ concealed conduit including PVC 2.5 sqmm multi strand copper conductor cable as continious earth wire complete and making good distrubed surfaces of wall /floor etc complete all as specified and directed.
Taking down carefully following item of any make/model after repair refixing of same or other position or depositing in MES store of AGE E/M (W) W/S Jabalpur complete all as specified and directed.
(a) Water cooler of any make and size
(b) Desert cooler of any make and size
(c) Window AC/Split AC of any capacity /position
(d) Refrigerator of any capacity /position
(e) Deep Freezer of any make and model
Servicing of summer cooling appliances including pressure testing of AC ,cleannig of indoor unit with blower & outdoor unit of AC washing, filter cleaning,copper tubing check etc, complete all as specified and directed by Engr-in-Charge.
(a) Water cooler of any make and size
(b) Desert cooler of any make and size
(c) Window AC/Split AC
Replacement of Old/UNSV Ply-wood grade BWR type BB 6mm thick (five Ply) cut into required size fixed where required with all fixing are complete all as specified and directed.
Replacement of old/UNSV Running capacitor for AC, Water Cooler, Desert Cooler of following capacity, any type and Make - GC/Universal/Havells/Epcos/Tibcon
(a) S&F in repair Capacitor aluminium body 45 Mfd 450 VAC 50 HZ Make - GC/Universal/Havells/Epcos/Tibcon
(b) S&F in repair Capacitor aluminium body 55+4 Mfd 450 VAC 50 HZ Make - GC/Universal/Havells/Epcos/Tibcon
(c) S&F in repair Capacitor aluminium body 45+4 Mfd 450 VAC 50 HZ Make - GC/Universal/Havells/Epcos/Tibcon
(d) S&F in repair Capacitor aluminium body 60+6 Mfd 450 V AC 50 HZ Make - GC/Universal/Havells/Epcos/Tibcon
(e) S&F in repair Capacitor aluminium body 60+4 Mfd 450 V AC 50 HZ Make - GC/Universal/Havells/Epcos/Tibcon
(f) S&F in repair Capacitor aluminium body 36 Mfd 450 V AC 50 HZ Make - GC/Universal/Havells/Epcos/Tibcon
(g) S&F in repair Capacitor aluminium body 50 Mfd 450 V AC 50 HZ Make -GC/Universal/Havells/Epcos/Tibcon
(h) S&F in repair Capacitor aluminium body 45 Mfd +6 450 V AC 50 HZ Make - GC/Universal/Havells
(j) S&F in repair Capacitor aluminium body 36 Mfd +6 450 V AC 50 HZ Make - GC/Universal/Havells/Epcos/Tibcon
(k) S&F in repair Capacitor aluminium body 50 Mfd +6 450 V AC 50 HZ Make - GC/Universal/Sarda
S&F in Replacement new Thermostate for AC, complete all as specified and directed by Engr-in-Charge.
S&F in Replacement of Old/damaged with new Chromium plate flush type Bib cock of 15mm dia for water cooler any type and any make complete all as specified and directed by Engr-in-Charge. .
S&F in replacement of Thermostate for water cooler of any type and any make /capacity complete all as specified and directed by Engr-in-Charge. ..
S&F in replacement of Over load protector for water cooler, as per existing size and make.
S&F in replacement installation and testing copper tubing of size 1/2" &1/4" along with sleeve insulation complete all as specified and directed by Engr-in-Charge. ..
S & F in replacement switch socket combination flush type 5 Amps including Make : PLAZA/KINJAL/ANCHOR complete all as specified and as directed.
M & L for fabrication of angle iron frame with equal angle of size 40x40x 6 mm suitable out door unit window/split AC 1.5/2 Ton capacity incl PCC work and fixing arrangement complete all as directed by Engr-in-Charge .
S & F in repairs single pole and neutral encloser with two pin and earth plug and socket complete with one MCB SP 32/20 Amps complete all as directed by Engr-in-Charge . Make: L & T/Legrarnd/Schinder.
S & F in repairs MCB SP, 230 volts, 20 to 32 amps as per complete all as directed by Engr-in-Charge .
S & F in repairs MCB SPN, 230 volts, 32 to 40 amps as per complete all as directed by Engr-in-Charge .
S&F in repairs Three core copper flexible wire PVC insulated cable and PVC sheathed of size 40/0.076 mm complete all as specified and directed.
S & F in repairs three pin plug top 15 A amps ISI mark complete all as directed by Engr-in-Charge . Make : PLAZA/KINJAL/ANCHOR
S & F in replacement of PVC connection ISI mark 15 mm dia & 60 cm long complete with rubber washer for water cooler complete all as specified and directed.
S & F MS fan blade suitable for follwing sizes including taking out of old unserviceble blade:-
S & F in replacement of heavy duty flexible PVC pipe 15 mm bore for desrt cooler complete all as specified and directed.
S & F in repairs air filter suitable for 1.5/2 Ton split AC as per existing size complete all as directed by Engr-in-Charge .
S & F in repairs Nitrile Rubber black insulation cover suitable for copper tubing any of size complete all as directed by Engr-in-Charge .
Re-filling of Refrigerent gas Non CFC R 410 of Window AC & Split AC of capacity 1.5 Tr including breezing, jointing,leak testing ,commissioning,taking down and refixing complete all as specified and directed .
Replacement of Old/UNSV PCB with new inbuilt inverter type PCB(printed circuit board ) units as existing model/make for split AC 1.5/2 Ton capacity complete all as specified and directed . Make:Blue star/Voltas/LG/Samsung
S & F in replacement swing motor of split AC cap 1.5/2 Ton, any type and any make/model complete all as specified and directed by Engr-in-Charge .Make: LG/Voltas/Samsung
S & F in replacement water tray suitable for split AC 1.5/2 Ton capacity, any type and any make/model complete all as specified and directed by Engr-in-Charge .Make: LG/Voltas/Samsung
S & F in replacement condensor Coil of window type/ split type AC cap 1.5/2 Ton any type and any make/model complete all as specified and directed by Engr-in-Charge .
S & F in replacement cooling coil of window type/split type AC cap 1.5/2 Ton, any type and any make/model complete all as specified and directed by Engr-in-Charge .
S & F in replacement of wiring kit of window type AC of cap 1.5/2 Ton, any type and any make/model complete all as specified and directed by Engr-in-Charge .
S & F in replacement of Freezer /Evaporator for refrigerator with freezer door of capacity 165, 280,310 ltrs any make/model complete all as specified and directed by Engr-in-Charge .
S & F in replacement of stainless steel tank of water cooler for all capacity of any make/model all as specified and directed.
S & F in replacement of condensing coil for refrigerator of capacity 165, 280,310 ltrs any make/model complete all as specified and directed by Engr-in-Charge .
S & F in repairs switch socket combination 15 Amp flush type, 240 Volts, 50 Hz of any make/model complete all as specified and directed by Engr-in-Charge .
Replacement of Old/UNSV PCB with new PCB(printed circuit board ) units as existing model/make for Window type AC 1.5/2 Ton capacity complete all as specified and directed . Make:Blue star/Voltas/LG/Samsung
S & F in replacement of remote control suitable for split AC cap 1.5/2 Ton, any type and any make/model complete all as specified and directed by Engr-in-Charge . Make: LG/Voltas/Bluestar/IFB
S & F in replacement of PVC drain pipe of 15mm dia and 0.5mm thick corrugated type complete all as specified and directed.
S & F in replacement of RO membrane , sediment filter ,Pre filter inbuilt in water cooler along with inlet and outlet pipe complete all as specified and directed by Engr-in-Charge . Make: Bluestar/ voltas
S & F in replacement of indoor unit of cap 1.5 ton split AC, any type and any make/model complete all as specified and directed by Engr-in-Charge. Make: Bluestar/ voltas
S & F in replacement of Out door unit of cap 1.5 ton split AC, any type and any make/model complete all as specified and directed by Engr-in-Charge. Make: Bluestar/ voltas
M&L for Shifting of split type AC by taking out AC from MES yard or from existing location to the new location by taking it after taking down, closing the opening of old location with cement mortar,white wash to match with the existing colour of the site & making holes in brick wall at new location and fine finishing with cement mortar white wash etc to match with the existing colour of the site installation & commissioning after replacement of insulation of suction & dischare line,charging,electrical connection only. ( Note:- (i) S&F insulation ,copper tube ,gas and other spare parts will be measured and paid separately under relevant items. (ii) Existing/ new location will be in Technical or Domestic area as per site requirement.)
Supply & filling Nitrogen gas for vaccum for Split AC/Window Type AC & other appliances all as specified and directed by Engr-in-Charge.
S&F in repair Flare Nut of any size (upto 1 inch) Make: as per sample
S&F in repair Overload Protector. As per Sample.
M&L LPG butane gas cartridge of capacity 230 gm for soldering.
S&F in repair overload relay for water cooler as per sample
S&F in repair overload relay for Refrigerator as per sample
S&F in repair for Non return valve for charging gas As per sample
S&F in repair Bi-Metal with timer suitable for Double door Refrigerator Make:- As per sample
S&F in repair Strainer two way/single way . make : As per sample
S&F in repair Capacitor aluminium body 6 Mfd ±5% 440 V AC 50 HZ Make -GC/Universal/Havells/Epcos/Tibcon
S&F in repair Capacitor of capacity 10mfd,±5% 220VAC . Make –GC/Universal/Havells/Epcos/Tibcon
S&F in repair Capacitor of capacity 12mfd,±5% 220VAC. Make –GC/Universal/Havells/Epcos/Tibcon
Attending of complaints of summer appliances deploying experienced air condition / refrigeration mechanic and helper and rectification of complaints to the entire satisfaction of Engineer-In-Charge and users. Note:-(i) For rectification of complaints if any spares, gas etc required to be replaced the same shall be measured and paid seperately under "supply and fixing" items. (ii) Mechanic engaged by contractor for attending complaints and rectification there of, shall carry the required job card, which shall be supplied by contractor at his own cost. (iii) Sufficient mechanic and staff shall be engaged by contractor in order to rectify the all complaints with in 24 hrs on all working days as well as holidays as given by the dept.If contractor fails to attend/rectify the complaints within 24 hrs he shall be panalised for Rs. 100 Per complaints. Note for Item No.1 to 129:- (i) Being maint contract site will be hand over to contractor as per complaint received from user and as per site requirement. (ii) Contractor trade man should report to AC section daily and take complaints from concern JE E/M and after attending complaint he will give feedback and return complaint slip to concern JE E/M in the evening at 17.30 Hrs on same day.
Haryana EngineerService (BID ID -3212980)
M/s Ajayshwar Singh Rana (BID ID -3213251)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .