Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
₹3 L
Closing Date
22 Dec 2021, 4:30 pmClosed
XEN REW KATHUA
XEN REW KATHUA
NTHPC upgradation and renovation of Allopathic Disp. mandli
2021_RDPR_152742_41
e-NIT No. 209 REW/K of 2021 Dated 11/12/2021
Open Tender
Civil Works
Item Rate
30 days
MANDLI
SBD
2 documents required · 2 mandatory
₹500
Yes
XEN REW KATHUA
Exempted
28 Dec 2021
13 Dec 2021
23 Dec 2021
14 Dec 2021
22 Dec 2021
14 Dec 2021
Amount
Removing white or colour wash by scrapping and sand papering andpreparing the surface smooth including necessary repairs to scratches etc. complete.
Distempering with oil distemper of approved brand and manufacture (twoor more coats) and of required shade on new work, over and includingwater thinnable priming coat to give an even shade
Finishing walls with water proofing cement paint of required shade Old work (one or more coats applied @ 2.20 kg/10sqm) overpriming coat of primer applied @ 0.80 liters/10sqm completeincluding cost of priming coat.
12 mm Cement plaster in 1 : 4 ( 1 cement : 4 fine sand)
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade Two or more coats on new work
Wiring for light point/fan point/exhaust point/with 1.5 sq mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class pvc conduit with paino type switch ,phenolic,laminated sheet,suitable size ms box, and earthing the point with 1.5 sq mm ,FRLS pvc insulated copper conductor sigle core cable etc required. (wire make ISI marked havells/anchor/HPl)
Wiring for circuit /sub main wiring along with earth wire with the following sizes of FRLS PVC isulated copper conductor ,single core cable,in surface /recessed medium class PVC conduit as required.( Wire make ISI markedShalimar/ Havells/Anchor/HPL . 2x2.5+1x2.5 sq m
Wiring for light /power plug with 2x4 sq.mm FRLs PVC Insulated Copper conductor single core cable in surface/ recessed medium class PVC conduct along with 1no. 4Sq.mm FRLs pvc insulated copper conductorsingle core cable for loop earthing as required
Supply and fixing suitable GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 and 15/16 A modular socket outlet 15/16 A modular switch connection etc as reqd
Suppling and fixing 5A to 32A rating, 240/415 V , 10 kA, "C" Curve , miniture circuit breaker suitable for inductive load of following poles in the existing MCB, DB complete with connection, testing and commissioning etc as reqd
1200mm size 18/20W LED batten Tubelight fitting
Supply and fixing 9W LED lamp
Supply of ceiling fan 230V 50Hz with double ball bearing with low power consumption of following sweeps including fan regulators
Supply and fixing of main service line 16sqmm twin core aluminium cable unarmoured from the LT pole upto the MCV/DB including connection etc as reqd
Supply and fixing following way single pole and neutral sheet steel MCB distribution board, 240V , on surface / recess complete with tinned copper bus bar neutral bus bar, earth bar interconnections power painted including earthing etc as reqd ( without MCB/RCCB/Isolators)
Supply and fixing following modular switch / socket on the existing modular plate , and switch box including connections but excluding modular plate etc as reqd
5/6A switch
3Pin 5/6A socket outlet
Supply and fixing modular blanking plate on the exising modular plate and switch box excluding modular plate as reqd
Supplying and fixing suitable G.I. box with modular plate and cover in front on surface or in recess , including providing and fixingg 3 Pin 5/6 A modular socket outlet and 5/6A modular switch connection etc as reqd
Wiring for light/ power plug with 2 x 4 sqmm FRLs PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit along with 1 no 4 sqmm FRLs PVC insulated copper conductor single core cable for loop earthing as reqd
Supplying and Fixing of following rating 240/10KA"C" curve , minature circuit breaker suitable for inductive load of following poles in the existing MCB/ DB complete with connections , testing and commissioning as reqd
Providing and fixing panelling or panelling and glazing in panelled or panelledand glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to bemeasured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. 4mm thick glass pane(wt not less than per sqm)
Providing and fixing 1mm thick M.S. sheet sliding-shutters with frame anddiagonals braces of 40x40x6mm angle iron, 3mm M.S. gusset plates at thejunction and corners, 25mm dia pulley, 40x40x6mm angle and T-iron guideat the top and bottom respectively including applying a priming coat ofapproved steel primer
Providing and making CIB of approved size by way of making another layer of 12 mm thick plaster with 1:4 cement mortar on front side outer plastered surface, painting and writings as per the direction of engineer in-charge including supply of materials, carriages all complete. L.M.R.
TILAK RAJ
RASAL CHAND GOVT CONTRACTOR
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .