Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.3 LAccepted-AOC | ₹14.3 L Quoted ₹15.4 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹15.6 L+₹15,274.68 (0.99%)Rejected-Finance VILL KADUA PO HARIATARA DISTT PASCHIM MEDINIPUR WB PIN 721304 | HARIATARA | PASCHIM MEDINIPUR | WEST BENGAL | 721304 | ₹15.6 L+₹15,274.68 (0.99%) | L2 | Rejected-Finance Not Being L1 |
| 3 | L3₹17.6 L+₹2.2 L (14.5%)Rejected-Finance GROUND FLOOR SUIT NO 2 SARITA APARTMENT KHARIDA MAIN ROAD KHARAGPUR 721 301 DIST PASCHIM MIDNAPORE WEST BENGAL | KHARAGPUR | PASCHIM MIDNAPORE | WEST BENGAL | 721301 | ₹17.6 L+₹2.2 L (14.5%) | L3 | Rejected-Finance Not Being L1 |
| 4 | L4₹18.4 L+₹3.0 L (19.3%)Rejected-Finance | ₹18.4 L+₹3.0 L (19.3%) | L4 | Rejected-Finance Not Being L1 |
| 5 | L5₹20.1 L+₹4.7 L (30.6%)Rejected-Finance VILL PO KOTA VIA PANAGARH BAZAR DIST BURDWAN WB PIN 713148 | BURDWAN | BURDWAN | WEST BENGAL | 713148 | ₹20.1 L+₹4.7 L (30.6%) | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
13 Oct 2021, 6:00 pmClosed
GE AF KALAIKUNDA
GE (AF) Kalaikunda PO Kalaikunda Air Field Dist Paschim Medinipore St West Bengal Pin 721303
REPAIR AND REWINDING OF CEILING FANS, EXHAUST FANS, WALL MOUNTED FANS, GEYSERS/ SOLAR HEATERS AND ALLIED WORKS AT DOMESTIC AND TECH AREA AT AF STN KALAIKUNDA
2021_MES_475313_1
8707/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AF STN KALAIKUNDA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF KALAIKUNDA
₹40,000
16 Dec 2021
15 Sept 2021
14 Oct 2021
15 Sept 2021
13 Oct 2021
30 Sept 2021
Amount
Taking down old ceiling fan/Exhaust fans/Wall mounting fans/ Air cirulators fan of any capacity/sweep after disconnecting the electric supply from any site, checking for its electrical defect and opening fans for checking of mechanical defect after dismantling of fan, carry out repair/over hauling including removing dust and grease, and cleaning of internal mechanical parts of fan with lubricant as per OEMs reccommendations, checking of alignment of shaft, oiling and greasing, checking of worn out bearing and other defective parts, winding, condenser etc and re-assembling, and connecting/refixing of fans in its original position , replacement of defective parts,re-assembling, hanging in original position including testing and commissioning, by providing new GI nut bolt, lock washer and lock/split pin complete all as specified and directed by Engr-in-charge. complete all as specified and directed. NOTE: (i) Rewinding and replacement of defective parts, Painting etc shall be measured and paid seperately (ii) Burnt out fan shall be kept separately and to be repaired (rewinded) in OEM workshop and to be hanged in existing position after rewinding. .
Supply only the following items as per OEMs specifications, complete. for fixing against defective parts of fan taking down under item No 1 here in before complete all as specified and directed by Engr-in-charge.
(a) Bearing No 6201 Make : SKF/NBC/FAG
(b) Bearing No 6202 Make : SKF/NBC/FAG
(c) Bearing No 6203 Make : SKF/NBC/FAG
(d) Bearing No 6204 Make : SKF/NBC/FAG
(e) Rubber Bush as reqd at site suitable for ceiling fan
Capacitors for electric fan motors, 2.5 mfd, 440 V conforming to IS:1709 (Cat No. QHPCWC5002X5 of Make Havells or equivalent Model of Make UNIVERSAL/EPCOS)
Capacitors for electric fan motors, 4.00 mfd, 440 V conforming to IS:1709 (Cat No. QHPCWC5004X0 of Make Havells or equivalent Model of Make UNIVERSAL/EPCOS)
Capacitors for electric fan motors, 6.00 mfd, 440 V conforming to IS:1709 Havells / of Make UNIVERSAL/EPCOS)
(j) Lathe work of Fan shaft any type / size as per OEM recommendation through OEM Workshop.
M&L for Rewinding of ceiling fan of sweep 1200 mm any make any model including taking down ,dismantaling of parts, removing burnt out windings with insulating materials,cleaning throughly internally and externally, rewinding fan motor with super enamelled copper wires of existing size including provision of all insulating materials and varnishing, lubrication of bearing / bushes using fresh lubricant all as per OEMs reccommendations, replacement of defective parts,re-assembling, hanging in original position including testing and commissioning, complete all as specified and directed. NOTES:- (i) Spare parts for replacement will be deemed to be included in Quoated rates. (ii) Repairs shall be carried out through authorised technicians of the OEMs as approved by GE.
M&L for Rewinding of ceiling fan of sweep 1400 mm any make any model including taking down ,dismantaling of parts, removing burnt out windings with insulating materials,cleaning throughly internally and externally, rewinding fan motor with super enamelled copper wires of existing size including provision of all insulating materials and varnishing, lubrication of bearing / bushes using fresh lubricant all as per OEMs reccommendations, replacement of defective parts,re-assembling, hanging in original position including testing and commissioning, complete all as specified and directed. NOTES:- (i) Spare parts for replacement will be deemed to be included in Quoated rates. (ii) Repairs shall be carried out through authorised technicians of the OEMs as approved by GE.
M&L for Rewinding of Exhaust fan of 450 mm any make any model , 1400 rpm including taking down ,dismantaling of parts, removing burnt out windings with insulating materials,cleaning throughly internally and externally, rewinding fan motor with super enamelled copper wires of existing size including provision of all insulating materials and varnishing, lubrication of bearing / bushes using fresh lubricant all as per OEMs reccommendations, replacement of defective parts,re-assembling, hanging in original position including testing and commissioning, complete all as specified and directed. NOTES:- (i) Spare parts for replacement will be deemed to be included in Quoated rates.
M&L for Rewinding of Exhaust fan of 380 mm any make any model , 1400 rpm including ,dismantaling of parts, removing burnt out windings with insulating materials,cleaning throughly internally and externally, rewinding fan motor with super enamelled copper wires of existing size including provision of all insulating materials and varnishing, lubrication of bearing / bushes using fresh lubricant all as per OEMs reccommendations, replacement of defective parts,re-assembling, hanging in original position including testing and commissioning, complete all as specified and directed. NOTES:- (i) Spare parts for replacement will be deemed to be included in Quoated rates. (ii) Repairs shall be carried out through authorised technicians of the OEMs as approved by GE.
M&L for Rewinding of Exhaust fan/ fresh air fan upto 300 mm any make any model including ,dismantaling of parts, removing burnt out windings with insulating materials,cleaning throughly internally and externally, rewinding fan motor with super enamelled copper wires of existing size including provision of all insulating materials and varnishing, lubrication of bearing / bushes using fresh lubricant all as per OEMs reccommendations, replacement of defective parts,re-assembling, hanging in original position including testing and commissioning, complete all as specified and directed. NOTES:- (i) Spare parts for replacement will be deemed to be included in Quoated rates. (ii) Repairs shall be carried out through authorised technicians of the OEMs as approved by GE.
M&L for Rewinding of wall mounted fan 400 mm sweep any make any model including ,dismantaling of parts, removing burnt out windings with insulating materials,cleaning throughly internally and externally, rewinding fan motor with super enamelled copper wires of existing size including provision of all insulating materials and varnishing, lubrication of bearing / bushes using fresh lubricant all as per OEMs reccommendations, replacement of defective parts,re-assembling, hanging in original position including testing and commissioning, complete all as specified and directed. NOTES:- (i) Spare parts for replacement will be deemed to be included in Quoated rates. (ii) Repairs shall be carried out through authorised technicians of the OEMs as approved by GE.
M&L for Rewinding of Pedestal fan 400 mm sweep any make any model including ,dismantaling of parts, removing burnt out windings with insulating materials,cleaning throughly internally and externally, rewinding fan motor with super enamelled copper wires of existing size including provision of all insulating materials and varnishing, lubrication of bearing / bushes using fresh lubricant all as per OEMs reccommendations, replacement of defective parts,re-assembling, hanging in original position including testing and commissioning, complete all as specified and directed. NOTES:- (i) Spare parts for replacement will be deemed to be included in Quoated rates. (ii) Repairs shall be carried out through authorised technicians of the OEMs as approved by GE.
M&L for Rewinding of Flame proof Exhaust fan upto 300/380 mm any make any model including ,dismantaling of parts, removing burnt out windings with insulating materials,cleaning throughly internally and externally, rewinding fan motor with super enamelled copper wires of existing size including provision of all insulating materials and varnishing, lubrication of bearing / bushes using fresh lubricant all as per OEMs reccommendations, replacement of defective parts,re-assembling, hanging in original position including testing and commissioning, complete all as specified and directed. NOTES:- (i) Spare parts for replacement will be deemed to be included in Quoated rates. (ii) Repairs shall be carried out through authorised technicians of the OEMs as approved by GE.
M&L for Rewinding of Industrial Air circulator fan of any make any model and sweep with including ,dismantaling of parts, removing burnt out windings with insulating materials,cleaning throughly internally and externally, rewinding fan motor with super enamelled copper wires of existing size including provision of all insulating materials and varnishing, lubrication of bearing / bushes using fresh lubricant all as per OEMs reccommendations, replacement of defective parts,re-assembling, hanging in original position including testing and commissioning, complete all as specified and directed. NOTES:- (i) Spare parts for replacement will be deemed to be included in Quoated rates. (ii) Repairs shall be carried out through authorised technicians of the OEMs as approved by GE.
S & F hot rolled medium and high tensile structural steel of grade E165 as per IS 15911: 2010 as in bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles complete all as specified and as directed.
Materials and labour for painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. including writing letters or figures (Block,Roman, Italic or Indian) n exc. 2.5 cm high and stops, commas, short lines, dashes,hyphens, brackets, etc. for writing MES/SM No., complete all as specified and directed.
Materials and labour for painting of Pedestal fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. including writing letters or figures (Block,Roman, Italic or Indian) n exc. 2.5 cm high and stops, commas, short lines, dashes,hyphens, brackets, etc. for writing MES/SM No., complete all as specified and directed.
Materials and labour for painting of exhaust fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. including writing letters or figures (Block,Roman, Italic or Indian) n exc. 2.5 cm high and stops, commas, short lines, dashes,hyphens, brackets, etc. for writing MES/SM No., complete all as specified and directed.
Supply and fixing 'U' clamp for hanging ceiling fan in ceiling to be fixed with 3" long anchor fastener 3 Nos for each clamps as per OEMs specifications complete all as specified and directed by Engr-in-Charge.
Supply and Fixing ceilling Fan down rod heavy duty as per existing dia and length of 50 cm including brass nut bolts, double waher, rubber bush heavy duty and spilit pin washers etc as per OEMs specifications complete all as specified and directed by Engr-in-charge.
Supply and fixing aluminium blade assy of celling fan of 1200 mm sweep (set of three) in replacement of make and colour as existing as per OEMs specifications as specified and directed by Engr- in - charge.
Taking down carefully, existing defective storage type water heater (geyser) of any Capacity and Make for repairing, including replacement of defective spares as required and including replacement of terminals with defective connection wires and reinstallation of the geyser in original position including testing and commissioning, complete all as specified and directed. NOTES:- (i) Repairs shall be carried out through authorised technicians of the OEMs as approved by GE. (ii) Spares for replacement will be measured and paid separately under respective items in S&F .
Supply and fixing the following spares of geyser in repair and testing suitable for storage type water heaters (Geyser) as per OEMs specifications, complete.
Thermostat, stem type, adjustable upto 75 Degree Celcius, ISI Marked (IS 3017).
(b) Heating element 1.5 KW, ISI marked as per existing Make : Bajaj / Usha/Theta
(c) Heating element 2 KW, ISI marked as per existing Make : Bajaj / Usha/Theta
(d) Glass Incandescent Electric Water Heater Indicator Lamp, in multi-color caps. with including flexibe copper wire of suitable size Red/Green
(e) PVC Connection with steel reinforced pipe for hot water connection of Size 18" x 1/2" including rubber washers.
(f) Copper Apperture plate suitable for 25/50 ltrs geyser along with rubber gasket, nuts, bolts,etc complete.
S&F in repairs Heating element 1.5 KW, ISI marked as per existing type Make : Bajaj / Usha/Theta/ Haveels/ Crompton as per OEMs specifications, complete. (Note heating element replaced without taking down of geysers and other than in item No. 19) is measured under this item.
S&F in repairs Heating element 2.0 KW, ISI marked as per existing type Make : Bajaj / Usha/Theta/ Haveels/ Crompton as per OEMs specifications, complete. (Note heating element replaced without taking down of geysers and other than in item No. 19) is measured under this item.
Supply and replacement of 3-Pin plug top 16 Amps. (Code No.39582 of Make Anchor or equivalent of Make Kinjal/Maru).
Supply and fixing 2 feet long hot/cold water PVC connection pipe, heavy duty, braided PVC pipe and the connector nuts coated with stainless steel, including rubber washer complete suitable for 50/25 ltrs geyser all as specified and directed including taking out old unserviceable pipe as per OEMs specifications, complete
M&L for complete servicing of solar hot water system (solar water heater, flate plate collector type), with cleaning of sluge deposited in pipe line of solar pannel by using cleaning regent, check and repair of pipe line for any leakage, including carring out brazing of copper pipe for leakage, cleaning of glass shell, cleaning of hot water tank, replacement of u/s clamps, adopter, hose pipe including filling of distilled water and coolent in reservior including complete sevicing to keep the plant functional of capacity up to 200 LPD. NOTES:- (i)Servicing shall be carried out through authorised technicians of the OEMs as approved by GE.
M&L in repair for replacement of thermostate, long body, ISI marked of solar water heater of cap up to 200 LPD as per OEMs specifications, complete
M&L in repair for replacement of electrical heating element of 2.0 KW (long thread type, as per existing), ISI marked, of solar water heater of cap up to 200 LPD as per OEMs specifications, complete. Make: Solar Element or equivelent as approved by GE.
M&L for replacement in repair hot water pipe insulation with glass wool and aluminium cladding 20 mm bore including all material as required as per OEMs specifications, complete directed by EIC.
S&F LED 18 Watt tube light fitting (T8 type) ,single end connection type including LED retrofit tube lamp 18 W , 240 Volt, PF > 0.90, colour Temp 6500 K, System Luminious efficacy > 100Lm/W, complete with powder coated CRCA decorative box type batten suitable for surface mounting on wall, complete fitting including connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm three core, and PVC round/ square box white colour x 2 Nos for mounting of fitting including taking down existing unserviceable one complete all as specified & directed. Make :- Bajaj (Batten Cat No. BLRB DB 118 box type batten suitable for 18/20 watt retofit LED tube single side connection type). LED lamp : Make : Bajaj Cat No. BLRB 18W CW LED (retrofit LED tube lamp 18 Watt, Single end connection) or equivelent Century (Batten Cat No.KCCF0200 box type batten suitable for 18/20 watt retofit LED tube single side connection type). LED lamp : Make : Century Cat No. TWPP020C (retrofit LED tube lamp 20 Watt, Single end connection) OR CROMPTON (Batten Cat No. IGP161LT8-16 box type batten suitable for 20 watt retofit LED tube ). LED lamp : Make : Crompton Cat No. LTT8-20 LED (retrofit LED tube lamp 20 Watt WIPRO/ as approved by GE. Note : Make of batten and LED tube lamp should be of same make.
S&F in repair LED bulkhead light of 10W / 12W with pressure die-cast housing along with polycarbonate diffuser and LED's IP-65 protction of watt, PF>0.95 complete all as specified and directed by Engineer in charge. Make : CENTURY - HWAR012C or Syska LED/ Crompton/Philips/Wipro as approved by GE.
Supply and fixing in repair of stepped type Modular electronic fan regulator 2 module, 100 watt flush type , (deluxe) on the existing hylam laminated sheet etc as required complete all as specified and directed ake: Anchor (Deluxe /Code:-14502) / L&T/ Havells
Supply and fixing in repair of stepped type electronic fan regulator 1 module (mini) 100 watt flush type , on the existing hylem laminated sheet etc as required complete all as specified and directed. Make: Anchor (Code:-14501) / L&T/ Havells
Supply and fixing in repair lamp holder , PVC/Poly carbonate type with back plate suitable for batten fittings to be fixed on PVC box including supply and fixing 10 /11 watt LED lamp and taking out u/s CFL or LED bulb. Make For holder : Anchor / L& T/ Havells. LED lamp : Philips/ Bajaj/ Crompton/ Havells
Supply and Fix in repairs for recess mounting downlight of capacity 12 Watt with aluminum die-cast body compact and sleek design, constant current LED driver, with fitting arrangement, rated input voltage 240 V, AC, 50Hz, complete all as specified and directed. Make :- Crompton Cat No.CDR-205-12-57-SL-NWH(PROXIMA) or equivalent in Phillips/Bajaj/Century.
Supply and fixing in repair for Round surface mounted LED panel , aluminum housing and high translucent frosted plastic diffuser , Efficacy 100 lm/w , 240 V , AC ,50Hz , complete all as specified and directed.Make:- Crompton Cat No:- LCDSPLN-R-18- CDL (PEARL NIOS -R) or equivalent in Phillps/ Bajaj/Century
S & F LED flood lights nominal power 120 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 100 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with polyester powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hours as per catalogue No. LF20-132-060-57-XX of Wipro or equivalent of Make mentioned under particular specification including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed.
S & F LED street lights nominal power 60 Watt, LED of Make Osram; Everlight; Philips; Nicha; Cree; Samsung, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen output of minimum 6000, lumen efficacy of minimum 100 lumens per watt, built-in integrated electronic LED driver, output open /short circuit protection, phase to phase protection, over voltage protection, surge voltage protection upto 4 KVs, protection grade IP 66, CRI greater than 80%, CW available CCT of 5700K, power factor of minimum 0.95, pressure die-cast aluminium alloy housing with polyester powder coated metallic silver finish after phosphochromate treatment, life span of minimum 50000 working hours as per catalogue No. LR02-671-XXX-57-XX of Wipro or equivalent of Make mentioned under Particular specification including fixing at any height and including wiring using three core PVC insulated, PVC sheathed, flexible stranded copper conductor FR-LSH cables suitable for outdoor use, 1.5 sqmm as per IS 694: 2010 complete all as specified and as directed. Note : (i) Connection cable to flood light and flood light bracket deemed to be incl in the item rate. (ii) At location where flood lights are connected through overhead conductor, connection cable from light fitting to overhead conductor is deemed to be incl in the item rate. (iii) All LED flood light shall be properly connected with earth dolly provided with fittings and steel poles. (iv) Contractor has to arrange his T&P for installation of this light inside gymnasium/ squash court or hanger as per requirement and as directed by Engr-in-Charge.
S&F in repair LED light with pressure die-cast housing along with prismatic polycarbonate diffuser and LED's with secondary optics and IP-65 protection of 25 watt,PF>0.9 for building security light complete all as specified and directed by Engineer in charge. Make : Century Cat Part No. SPS 025C or Crompton /CG/Philip/Wipro as approved by GE.
Supply and fixing PVC insulated multistranded Copper conductor, sheathed round cable ISI marked 1.0 sqmm x 3 core complete all as specified and directed by Engr-in-charge.
Supply and fixing PVC insulated multistranded Copper conductor, sheathed round cable ISI marked 2.5 sqmm x 3 core complete all as specified and directed by Engr-in-charge.
Taking down old unserviceable GI/Copper earth plate from soft and hard soil from any location as directed by Engineer -in- charge.
M&L earthing complete with copper earth plate electrode 600 mm x 600 mm x 3 mm thick burried directly in ground (Earth pit not less than 4 mtr deep below ground level) with top edge of the plate not less than 3.25 mtr below ground level connected to copper strip 20 x 3 mm as earth lead by brass nut bolts washer including brazing the copper strip with copper plate as shown in electrical plate No 3 connected to earth test point including necessary excavation in hard dense soil / disintergate rock, filling charcoal and salt around the plate in layers , filling the pit with agriculture soil free from stones, to be bring from out side defence land and mixed with Bentonide (3 bags of 25 Kg each ), construction of inspection pit of brick work of size 600 x 600 x 600 mm with PCC copping of 1 :2: 4 , 12.5 mm aggregate A1 with MS sheet 3 mm plate cover on frame of angle iron of size 40 x 40 x 5 mm with , wire mess, funnel, test point, 40 mm dia GI protection pipe light grade and 32 mm GI peforated pipe for watering etc complete and testing on completion. The electrode and lead shall be of copper all as specified and directed by Engr-in-charge (Copper strip upto 7.5 RM will be included in the item rate and copper strip beyond 7.5 RM will be measured seperately (Note : (i) Contractor shall use Fresh agriculture soil , mixed with 3 x Bags of bentonide of 25 Kg each for refilling the pit to achive the desired resistance. (ii) copper strip will be laid below 60 cm from ground level and connected to test point through plinth protection (iii) Necessary cost of repair to plinth protection and connected plate and earth continuity conductor by providing 2 x brass nuts bolts and brazing of joints, bringing argiculture soil from out side defence land and cost of 3 x Bags of bentonide deemed to be included in the item rate. (iv) Contractor has to clear the side and disposed off the excavated soil from pit on completion of work.
M & L for laying of GI tube medium grade 25 mm bore with all fitting as required at site and fixed to wall and ceiling or laid in floor including connection with existing line all as directed by Engineer -In -charge.
M & L for laying of GI tube medium grade 20 mm bore with all fitting as required at site and fixed to wall and ceiling or laid in floor including connection with existing line all as directed by Engineer -In -charge.
Taking out old unserviceable GI/aluminium/copper earth wire/strip of any size and type in any height and any location as directed by Engineer In charge.
M & L for copper earth contInuity conductor of size 20 x 3 mm strip with insulator fixed to wall or drawn in conduit/pipe as required all as directed by Engineer In charge. Note: Insulator to be fixed on every one meter distance and cost of insulator is deemed to be included in unit rate of item.
Supply & laying of UPVC pipe of size 25 mm dia for incorporating of earthing copper strips complete all as specified and directed by Engineer -in-charge
S&F for thermoplastic(polycarbonate) junction box for test point without terminal block of dimension 130x180 x 77 mm IP 66 halogen free and weather proof including four hexagonal anticorrosive screws for out door installation including taking down unserviceable one. Make : Hensel- Cat part No. KF 1000 H
M&L in repair for Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed incl 3 Nos 8mm dia 25mm long hexagonal head screws for fixing strips to test point including necessary fixing arrangement to fix test point terminal block in junction box all as specified and directed. including taking down unserviceable one.
S&F in repair Surge protection device Type 1 + 2 to withstand implus current with 10/350 us wave to simulate lightining current. SPD having max contionous operating voltage - 440 Uc (v), I imp in KA(10/350 Us wave) - 12.5 KA , I max in KA(8/32 Us wave) - 80 KA, Pole 3+1 (3 Pole + Neutral), 4 module including installation in parallel connection in DB and making all electrical connections with 4 x 6.0 Sqmm single core copper wire with copper lugs complete all as specified and directed by Engineer in charge. Make ABB cat Part No. OVR T1-T2 3N 12.5-440s P QS (2CTBB15710R4800) or equivalent in Havells/ L&T.
S&F in repair Surge protection device Type - 2, having max contionous operating voltage - 440 Uc (v), I max in KA(8/32 Us wave) - 40 KA, Pole 3+1 (3 Phase + Neutral), 4 module including installation in parallel connection in DB and making all electrical connections with 4 x 6.0 Sqmm single core copper wire with copper lugs complete all as specified and directed by Engineer in charge. Make ABB cat Part No. OVR T2 3N 40-440 P QS (2CTB803973R1400) or equivalent in Havells/ L&T.
S&F in repair Condenser 2.5 mfd, 240 Volts, in attending fan complaint Make: Epcos/Tibcon/ Havells
S&F in repair Condenser 4.0 mfd, 240 Volts, in attending fan complaint Make: Epcos/Tibcon/ Havells
General Note : The work is to be executed as per complaints received from users day to day. Contractor is liable to levy compensation for delaying in execution. Complaints having in repair to Fan, Geyser, Solar and LED Flood Light , compensation will be levied after 24 hours excluding the date of receipt of complaints either through Digital mode or offline mode @ ` 500.00 per complaint per day of work delayed for execution till physical completion of per complain. (ii) Contractor has to detail his supervisior to visit office of AGE E/M complaint cell daily in morning and take the complaints releated to his scope in subject work from concern JE .Also contractor is responsible to get the signature with date of the users/rep of units as a token of work executed physically and the same will be handed over to the concerned JE. However delay (if any) for unforeseen reason, natural calamities etc. shall be recorded separately. (III)A register shall be maintained by the concerned Engineer-in-Charge and same will be fwd alongwith running payment for verification before payment to the contractor
Neha Enterprise
Lotas Engineers
I.S.ENTERPRISE
NATIONAL CONSTRUCTION CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .