Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.8 LAccepted-AOC | L1 | Accepted-AOC Found reasonable for acceptance | |
| 2 | L2₹8.0 L+₹6,191.90 (0.78%)Rejected-Finance FLAT NO 402 4TH FLOOR BLDG NO 31 HANSGEET CO OP HSG SOCIETY PANT NAGAR GHATKOPAR E MUMBAI 400 075 | MUMBAI SUBURBAN | MAHARASHTRA | 400075 | L2 | Rejected-Finance L1 being accepted |
Tender Value
₹8.2 L
EMD Value
₹16,300
Closing Date
8 Apr 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (P) Navy Mandovi
GE (P) Navy Mandovi Military Engineer Services INS Mandovi
As per tender documents
2024_MES_644404_1
8523/E8 GE (P) NAVY MANDOVI
Open Tender
Construction Works
Item Rate
180 days
Mandovi
As per tender documents
7 documents required · 7 mandatory
₹500
GE (P) Navy Mandovi
₹16,300
Yes
11 Nov 2024
28 Feb 2024
10 Apr 2024
28 Feb 2024
8 Apr 2024
16 Mar 2024
28 Feb 2024 - 15 Mar 2024
Amount
B/R WORKS
Taking down cement or cement lime plaster, any description on stone/ PCC block/ brick wall or top of chajja including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M & L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6, finished even and smooth without using extra cement complete all as specified and directed.
M & L for preparation of newly plastered wall surfaces, priming with alkali resistant priming paint, applying 1 mm thick wall care putty wherever required and distempering with two coats of distemper oil emulsion, white or tinted, complete all as specified and directed.
M & L for rendering 15 mm (10+5) thick on fair faces of brick work or concrete wall surfaces in cement mortar 1:4 in two layers i.e first layer 10 mm thick and 5 mm thick outer layer mixed with WPC as per manufacturer's instruction and surfaces finished even and smooth without using extra cement including all necessary scaffolding, trestles, ladders, cradles etc. for execution of work and protective/ safety measures complete all as specified and directed. Note: Quoted rate shall be deemed to be inclusive of cost of WPC.
M & L for preparation of newly plastered wall surfaces and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces ncluding all necessary scaffolding, trestles, ladders, cradles etc. for execution of work and protective/ safety measures complete all as specified and directed.
M & L for rendering 5 mm thick in cement mortar 1:3 on fair faces of brick work or concrete ceiling surfaces and surface finished even and smooth without using extra cement complete all as specified and directed.
M & L for preparation of newly plastered ceiling surfaces and applying three coats of white wash complete all as specified and directed.
M & L for preperation of old plastered wall surface including washing down, rubbing down and stopping of distempered wall surfaces, applying 1 mm thick wall care putty wherever required and applying one coat of oil bound distemper complete all as specified and directed.
M & L for preparation of old decorative wall surfaces, ceiling cornices etc by brooming, scrapping down dust particle, smoke soot, moulds, moss and efforescent salts etc, making surface smooth by applying ready mix putty where ever required and applying one coat of acrylic emulsion exterior paint including all necessary scaffolding, trestles, ladders, cradles etc. for execution of work and protective/ safety measures complete all as specified and directed.
M & L for preperation of old plastered wall surfaces and applying two coats of white wash complete all as specified and directed.
Taking down chowkats or frames not exceeding 1.5 sqm each, with shutters (without taking off shutters from the frames) complete all as specified and directed.
Taking down chowkats or frames exceeding 1.5 sqm but not exceeding 4.0 sqm each, with shutters (without taking off shutters from the frames) complete all as specified and directed.
S & F 2nd class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid rounded or chamfered, put together with glue pinned at joints complete all as specified and directed.
S & F factory made 2nd class hard wood plain, framed, panelled shutter (two panel), 40mm thick, with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces and size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed.
S & F extruded aluminium alloy handles, 125 mm long, fabricated type, anodised complete all as specified and directed.
S & F aluminium anodised, barrel tower bolts of extruded section and 150 mm length complete all as specified and directed.
S & F aluminium alloy, anodised, sliding door bolt of 300 mm size, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and directed.
S & F 100 mm long butt hinges, medium weight, powder coated, cold rolled mild steel complete all as specified and directed.
S & F 4 mm thick sheet glass, ordinary quality and glazing with oil putty/ beading in squares exc 0.5 sq. m in each pane complete all as specified and directed.
S & F 4 mm thick sheet glass, ordinary quality and glazing with oil putty/ beading in squares not exceeding 0.5 sq. m in each pane complete all as specified and directed.
M & L for preparation of new wooden surfaces of any description exc. 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M & L for preparation of old painted wood and wood based surfaces of any description, not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
S & F in repairs floor door stopper of aluminium alloy body and tongue, anodised with hard draw steel spring, 140mm overall length of cover plate complete all as specified and directed.
S & F in repairs stainless steel premium 06 Pins 'L' type cloth hanger complete all as specified and directed.
S & F mild steel clamps; hold fasts; wall ties and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed.
Cutting holes in brick walls built in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required, depth of embedded portion of holdfasts or lugs measured from the face of the jamb into the wall exc. half brick but not exc.one brick complete all as specified and directed.
S & F aluminum powder coated window/ ventilator shutter including frame, any type (sliding or open-able) and other similar work etc, fabricated, by using sections, including necessary arrangement to receive 4mm thick sheet glass or wire mesh with aluminium channel beading, stainless steel screws, rollers, maruti lock including the cost of rubber gasket / rubber beading, rollers, maruti lock etc, fixing frames complete all as specified and directed. Notes: (i) Weight of rubber gasket / beading rollers, maruti lock will not be measured with weight of aluminium shutter. (ii) Sheet glass & wire mesh shall be measured and paid separately.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
S & F rolled mild steel Fe-290 (Gde E-165) in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. complete all as specified and directed.
S & F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161- 1979 grade St. 240 complete all as specified and directed.
S & F mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk), forming holes, with riveted, bolted or welded attachment confirming to Fe 410-W(Gde-E-250) Quality-A complete all as specified and directed.
M & L for preparation of new steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M & L for preparation of old painted steel surfaces of any description, not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M & L for complete repair of collapsible steel gate, top hung, consisting of channel pickets, pickets, pivoted flat bars, top and bottem runners etc., as specified, erecting in position and securing runners with hold fasts and brackets, complete all as specfied and directed
E/M WORKS
Taking down copper/ aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. and making good disturbed surfaces of walls, floors, etc to match existing surface complete all as specified and directed.
Taking down DB complete all as specified and directed.
Taking down submain wiring complete all as specified and directed.
M & L for point wiring complete with 1.5 Sqmm 1100 volts grade single core PVC insulated FRLS unsheathed cable with multistranded copper conductor confirming to IS-694, Part II, ISI marked, drawn through and including medium grade PVC conduit of size not less than 25mm dia, ISI marked with all accessories, concealed in wall/ ceiling, pressed steel terminal boxes firmly fixed with pipe /wall including concealed GI sheet metal box (rust protected), suitable modular frame and top cover fixed with chromium plated brass screws for fixing switches, sockets, regulators etc., and including providing 1.5 sqmm 1100 volts grade single core PVC insulated FRLS unsheathed cable with multistranded copper conductor in green colour as earth continuity conductor connected to common earth dolly for the following complete all as specified and directed. Note: Quoted rate shall be deemed to be inclusive of cutting chasis in wall/ floor/ ceiling and making good disturbed surface with PCC work and paint etc.
One light point controlled by one switch
One ceiling/ exhaust fan point controlled by one switch
One light point controlled by two way switch
One switch socket combination 3 pin 5 Amp on same board
One switch socket combination 3 pin 5 Amp on independent board
M & L for point wiring complete with 2.5 Sqmm 1100 volts grade single core PVC insulated FRLS unsheathed cable with multistranded copper conductor confirming to IS-694, Part II, ISI marked, drawn through and including medium grade PVC conduit of size not less than 25mm dia, ISI marked with all accessories, concealed in wall/ ceiling, pressed steel terminal boxes firmly fixed with pipe /wall including concealed GI sheet metal box (rust protected), suitable modular frame and top cover fixed with chromium plated brass screws for fixing switches, sockets, regulators etc., and including providing 2.5 sqmm 1100 volts grade single core PVC insulated FRLS unsheathed cable with multistranded copper conductor in green colour as earth continuity conductor connected to common earth dolly for one 3 pin 15 Amps switch socket combination on independent board complete all as specified and directed. Note: Quoted rate shall be deemed to be inclusive of cutting chasis in wall/ floor/ ceiling and making good disturbed surface with PCC work and paint etc.
S & F in repairs modular switch 1 way 6A, 1 module, for 230V 50Hz AC supply complete all as specified and directed.
S & F in repairs modular switch, two way 6A, 1 module, for 230V 50Hz AC supply complete all as specified and directed.
S & F in repairs modular switch 1 way 16A, 1 module, for 230V 50Hz AC supply complete all as specified and directed.
S & F in repairs modular socket 6A, 2/3 pin 2 module, for 230V 50Hz AC supply complete all as specified and directed.
S & F in repairs modular socket 6/16A, 2/3 pin 2 module, for 230V 50Hz AC supply complete all as specified and directed.
S & F in repairs modular fan regulator, eletronic step type, 120 watt, 2 module, for 230V 50Hz AC supply complete all as specified and directed.
S & F in repairs ceiling rose, 3 terminal, PVC polycarbonated isolating body, complete all as specified and directed.
S & F in repairs ceiling fans, 230V, 1200mm sweep alongwith neccssory accessories like downrod, blades, fixing rubber clamps, cups etc marking of MES No and depositing old unserviceable ceiling fan in MES storeyard complete all as specified and directed.
Fixing only in repairs LED tube light fitting 1 X 20 watt, 220V AC, baton integrated LED channel integral sleek extruded polycarbonate LED channel with white acrylic cover alongwith LED tube including connecting with three core flexible copper conductor cable of suitable size from ceiling rose to fitting duly mounted on PVC block with steel screw complete all as specified and directed. Notes: (i) LED tube light shall be issued to contractor under Schedule 'B' free for fixing. (ii) Quoted rate shall be deemed to be inclusive of cost of fixing screws, PVC square blocks & flexible wire etc.
S & F LED bulb, 9 watt along with batten holder duly mounted on PVC block with steel screws & sleeves complete all as specified and directed.
S & F exhaust fan, 300 mm sweep single phase 230/240 volt AC supply 50 HZ, made of sturdy engineered plastic complete with louvers and shutters, fixed with suitable MS Bracket, nuts, bolts and fixing arrangement, including making/ resizing holes and PCC work as per site requirement complete all as specified and directed.
S & F MCB's (D.B), sheet metal enclosure, double door, SPN 4 way, suitable for 240 volts 50 Hz AC supply complete all as specified and directed.
S & F MCB's (D.B), sheet metal enclosure, double door, TPN 4 way, suitable for 240 volts 50 Hz AC supply complete all as specified and directed.
S & F in repairs MCB SPN 6 to 32 Amps, 'C' series, suitable for 230 volts 50 Hz AC supply complete all as specified and directed.
S & F in repairs MCB TPN 40 to 100 Amps, 415 Volts, 'C' curve complete all as specified and directed.
S & F in repairs MCB SP 6 to 32 Amps, 240 Volts, 'C' curve, 10kA breaking capacity complete all as specified and directed.
M & L for providing submain wiring with two runs of 4 sqmm single core multistranded PVC insulated unsheathed cable 1100 Volts with copper conductor and one run of 4 sqmm single core PVC insulated unsheathed cable 1100 Volts with copper conductor as continuous earth wire drawn through and including rigid PVC conduit of 25 mm dia concealed in wall/ceiling with all accessories such as tees, elbows, junction boxes, reducers etc as required, connecting to existing main switch board/ distribution board and testing on completion and making good disturbed surfaces and painting to match with existing surface complete all as specified and directed. Note: Two runs of 4 Sqmm cable, one run of 4 Sqmm earth wire and one run of PVC conduit shall be measured as unit run.
M & L for providing submain wiring with two runs of 2.5 sqmm single core multistranded PVC insulated unsheathed cable 1100 Volts with copper conductor and one run of 2.5 sqmm single core PVC insulated unsheathed cable 1100 Volts with copper conductor as continuous earth wire drawn through and including rigid PVC conduit of 25mm dia concealed in wall/ceiling with all accessories such as tees, elbows, junction boxes, reducers etc as required, connecting to existing main switch board/ distribution board and testing on completion and making good disturbed surfaces and painting to match with existing surface complete all as specified and directed. Note: Two runs of 2.5 Sqmm cable, one run of 2.5 Sqmm earth wire and one run of PVC conduit shall be measured as unit run.
S & F in repairs GI bracket arm, 1.2 m long, made out of 32 mm dia bore light grade GI pipe, for mounting street light fitting, bent to required shape, fixed on to wall/pole with suitable clamps including necessary GI bolts, nuts, washers etc complete all as specified and directed.
Fixing only in repairs LED building light fitting, 45 watts for 230 V 50 Hz AC supply, in existing GI bracket with suitable size clamps with bolts,nuts and washers including connecting with three core flexible copper conductor cable of suitable size from ceiling rose to fitting complete all as specified and directed. Notes: (i) LED building light shall be issued to contractor under Schedule 'B' free for fixing. (ii) Quoted rate shall be deemed to be inclusive of cost of fixing screws, nuts and bolts & flexible wire etc.
Fixing only in repairs LED flood light fitting, 150 watts for 230 V 50 Hz AC supply, and connecting with existing supply including all accessories for fixing on pole/ wall and connecting with three core flexible copper conductor cable of suitable size from ceiling rose to fitting complete all as specified and directed. Notes: (i) LED flood light shall be issued to contractor under Schedule 'B' free for fixing. (ii) Quoted rate shall be deemed to be inclusive of cost of fixing screws, nuts and bolts & flexible wire etc.
M & L for providing earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6.3 mm thick buried directly in ground, earth pit not less than 2.25 m below ground level, with top edge of plate not less than 1.5 m below ground level, connected to 4mm dia GI earth wire by means of bolts, nuts, check nuts and washers of galvanised steel including neccessary earthwork and excavation in any strata, PCC earth chamber in PCC 1:3:6 type C1, 20 mm dia light grade GI pipe for protection of earth strip and GI wire, 15 mm dia light grade GI pipe with funnel for watering, RCC chamber cover etc all as per electrical plate No. 3 of SSR Part-I including connections with earth testing point complete all as specified and directed. Note: On testing after completion if the desired earth resistance is not obtained, earthing shall be redone at no extra cost.
Ramesh Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .