Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹31.6 LAccepted-AOC R O ABI GUZAR THE BUND SRINAGAR 190001 J K | SRINAGAR | JAMMU AND KASHMIR | 190001 | L-1 | Accepted-AOC Being L-1 | |
| 2 | L-2₹34.4 L+₹1.6 L (4.78%)Rejected-Finance R O KHREW TEH PAMPORE DISTT PULWAMA PIN 191103 J K | PULWAMA | JAMMU AND KASHMIR | 191103 | L-2 | Rejected-Finance Not being L-1 | |
| 3 | L-3₹34.6 L+₹1.8 L (5.38%)Rejected-Finance | L-3 | Rejected-Finance Not being L-1 | |
| 4 | L-4₹35.8 L+₹3.0 L (9.13%)Rejected-Finance R O KHREW PULWAMA J K 191103 | PULWAMA | JAMMU AND KASHMIR | 191103 | L-4 | Rejected-Finance Not being L-1 | |
| 5 | L-5₹35.9 L+₹3.1 L (9.43%)Rejected-Finance | L-5 | Rejected-Finance Not being L-1 |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
3 Feb 2024, 6:00 pmClosed
GE 861 EWS
GE 861 EWS c/o 56 APO
SPECIAL REPAIRS TO BUILDING NO T 41 OR LIVING ACCOMMODATION AT UPPER GRN OF 15 CBS KHREUH, PROVISION OF CHEQUERED TILE PATH AND ENTRANCE GATE AT 405 COY PET AND PROVISION OF PARKING SHED AT STATION HQ KHUNMOH UNDER AGE BR III OF GE 861 EWS
2024_MES_635946_1
GE861 EWS-69/2023-24
Open Tender
Civil Works
Item Rate
270 days
GE 861 EWS
As per Tender Documents
7 documents required · 7 mandatory
₹50
Yes
GE 861 EWS
₹86,000
Yes
29 Mar 2024
5 Jan 2024
10 Feb 2024
5 Jan 2024
3 Feb 2024
20 Jan 2024
Amount
Taking down cement plaster on brick or concrete surfaces including raking out joints, hacking for key scrubbing down with water etc complete all as specified and directed.
Demolition of cement concrete in ground floors and pavings n exe 15 cm thick below or above GL complete all as specified and directed.
Demolition of brick or stone masonry built in cement mortar including all necessary arches quoins etc. complete all as specified and directed.
Demolition of reinforced cement concrete of any description (reinforcement cut as reqd to facilitate demolition ) complete all as specified and directed.
Taking down chowkhat or frames with shutters (without taking off shutter from the frame) exceeding 1.5sqm and not exceeding 4.00 sqm each complete all as specified and directed.
Taking down chowkhats or frame with shutters (without taking off shutters from the frame) n exe 1.50 Sqm each complete all as specified and directed.
Taking down shutters of any description exc 1.0 sqm but n exc 2.00 Sqm each leaf complete all as specified and directed.
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 in depth for foundation etc or for shafts well cesspits manholes pier holed etc 10 Sqm on plan and n.exc 1.5m in depth and getting out in hard and dense soil complete all as specified and directed.
M&L PCC 1:4:8 type D2 using 40 mm graded crushed stone aggregate in foundation filling and mass concrete / Bed concrete complete all as specified and directed.
M&L for RCC M-25 Design mix ( using 20 mm graded crushed stone aggregate ) as in foundation, including rafts, footing, foundation beams, plinth beams, bases for columns etc basement slabs complete all as specified and directed.
M&L for RCC M-25 Design mix (using 20mm graded crushed stone aggregate) as in columns, pillars, piers, post and struts. Complete all as specified and directed.
M&L for RCC RCC M-25 Design mix (using 20mm graded crushed stone aggregate) as in RCC bands, lintels over 1.5 span etc, complete all as specified and directed.
M&L for RCC M-25 Design mix (using 20mm graded crushed stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for form work to sides of concrete foundations, footings, bases of columns, sides and soffits, plinth beams and similar work complete all as specified and directed.
M&L of form work sides of RCC bands, lintels etc, complete all as specified and directed.
M&L of form work sides of columns, pillars etc complete all as specified and directed.
M&L of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200m thick (Horizontal or sloping) complete all as specified and directed.
S&F for mild steel TMT bars 10mm dia and over cut to length bent to shape required including cranking bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire not less than 0.9mm dia or securing with clips complete all as specified and directed.
All as per item No 18 above but 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders Complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in CM 1:4 complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan to any radius in half brick thick walls built in CM (1:4) complete all as specified and directed.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finished fair and even without using extra cement complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar 1:6 on brick or concrete surfaces finished even & smooth without using extra cement complete all as specified and directed.
M&L for rendering 5 mm thick in cement mortar 1:3 on brick or concrete surfaces finished even & smooth without using extra cement as in ceiling complete all as specified and directed.
M &L for preparing plastered or un plastered new surfaces of walls and applying two coats of Cement base paint on walls over a coat of alkali resistant priming paint complete all as specified and directed
M &L for preparing plastered or un plastered new surface of walls and applying three coats of white wash on walls complete all as specified and directed.
M &L for preparing new plastered surface of celling and applying three coats of white wash on ceiling complete all as specified and directed.
M&L for moorum/red bajri filling in floors or paving laid in layers n exc 15 cm thick spread levelled and consolidated including watering complete all as specified and directed.
M & L for broken stone hard core of gauge not exc. 63mm, deposited, spread and levelled rammed in layers not exc. 15cm thick, watered and well rammed to a true surface complete all as specified and directed.
M & L for 100 mm thick PCC 1:3:6 type C2 using 40mm graded crushed stone aggregate as in sub base, floors and pavings etc.complete all as specified and directed.
S&F for coloured Non skid ceramics joint free tiles 7mm to 8mm thick area of each tiles exceeding 0.06 Sqm but n.exc 0.11 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including screed bed/bedding layer 15mm thick in cm 1:6 complete all as specified and directed.
M&L for glazed ceramic coloured tiles in vertical surfaces 350 x250x7/450x350x7 mm thick , set and jointed in neat cement slurry and pointed in white or colour cement to match laid over and including 10mm thick backing coat in cm (1:4) complete all as specified and directed.
M&L for 75 mm thick PCC ( 1:3:6) type C-2 using 40mm garded crushed stone aggregate as in plinth protection etc complete all as specified and directed.
S&F roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc Fe 290 Gde E-165 complete all as specified and directed.
M&L for preparation of new steel surfaces over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red-oxide zinc chrome primer complete all as specified and directed.
S&F in repairs vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) including connections of flush pipe to squat pattern closet including PVC (SWR) P trap 110 mm bore fixed with WC, lime concrete bedding and all joint, making good to the floor complete all as specified and directed.
S & F in repairs vitreous china bowl urinal flat back, size of 465 x 355 x 265 mm white (min), with grating and union for discharge pipe excluding flushing cistern, flush pipe & waste pipe) complete all as specified and directed.
S&F in repair PVC valveless 10 litre capacity syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and directed.
S&F in repair Vitreous china wash hand basin, white, flat back, size 550 x 400 mm with brackets, including cutting for and pinning in ends of brackets or erecting stand complete all as specified and directed. (Including 15mm bore CP pillar tap, waste coupling and 32mm dia PVC waste pipe) complete all as specified and directed.
S&F in repairs 15 mm size PVC connection with PTMT nuts, 600 mm long complete all as specified and directed.
S&F in repairs swivel shower of PTMT any colour with arm, 195 mm long with bend of 45 degree with flange (both min wt 80 gms ) complete all as specified and directed.
S&F in repairs 75 mm dia PVC (SWR) floor trap, with grating including jointing to waste pipe fixed in cement concrete (1:2:4) type B1 using 20mm graded crushed stone aggregate complete all as specified and directed.
S&F in repair Gully trap PVC (SWR) 125/110 mm dia including jointing to pipe complete all as specified and directed.
S&F in repairs 15 mm bore fancy type CP bib taps cast copper alloy with crutch or butterfly handle, screwed down for iron pipe complete all as specified and directed.
S&F & repairs, 15 mm bore CP stop/angle valve cast copper alloy screwed down , high pressure with crutch or butterfly handle fancy type complete all as specified and directed.
Dismantling water storage tanks of any description n. exc 500 litres capacity and removing from site complete all as specified and directed.
S&F for Rotational moulded polyethylene 500 litres capacity water storage tank (Cylindrical vertical with closed top), 3 layered hoisted and fixed in position including 20 mm ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball complete all as specified and directed.
S & F in repairs gun metal globe or gate valves, with iron wheel head, screwed both ends for iron pipes and fixed for bore of pipe 20 mm complete all as specified and directed.
M&L 2nd class hard wood, plain solid straight chowkhats and frames wrought, framed, rebated on the solid rounded or chamfered put together with glue pinned at joints complete all as specified and directed.
S&F 2nd class hard wood 35 mm thick panelled shutter (any number of panels ) with panels of timber flat on both sides (feathered edged), or veneered particle board medium density, wood particle board with commercial face veneers supplied and fitted to chowkhats complete all as specified and directed
Supply and fixed 35mm thick 2nd class hard wood glazed and skeleton shutters open rebated and prepared to receive glass, gauge etc (internal sash bars) edges of framing plain, chamfered or rounded fitted and mitred beads for securing glass etc size of members as specified in SSR Part-I Section 8 clause 8.24(a) (kail) complete all as specified and directed.
S&F for 30 mm thick 2nd class hard wood glazed and skeleton shutters open rebated and prepared to receive glass, gauge etc windows/ventilators, devided into square with plain chamfered or rounded, mitred and rebated sash bars any numbers , provided with stiles and rails as specified in SSR part I section 8 clause 8.24 (b) complete all as specified and directed.
M&L for 4mm thick sheet glass ordinary quality and glazing with oil putty or fixed with bead/glazing pins in squares n.exc 0.5 Sqm in each pane complete all as specified and directed.
S&F Factory made solid PVC door frame of size 50mm x 47mm made out of 5 mm thick single side prelaminated PVC sheet reinforced with MS square tube manufactured as per SSR Part-I specifications and drawings complete all as specified and directed.
S&F factory made sold panelled PVC door shutter 30mm thick (style) consisting of frame made out of MS tube for top and bottom rails MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail lock rail and bottom rail on either side and gap insert for top rail and bottom rail panelling of plain colour PVC to sheet to be fitted in the MS frame welded / sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement complete all as specified and directed.
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm fixed with tinned tacks, or stainless steel wire staples complete all as specified and directed.
S&F aluminium alloy, anodised, sliding door bolt of length 300 mm with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of sections or cast-aluminium extruded alloy and fixed complete all as specified and directed.
S&F aluminium anodised barrel tower bolts extruded section of size 200 mm complete all as specified and directed.
S&F aluminium anodised barrel tower bolts extruded section of size 150 mm long complete all as specified and directed.
S&F aluminium handle extruded fabricated type anodised of size 150 mm complete all as specified and directed.
S&F aluminium handle extruded fabricate type anodised of size 100 mm complete all as specified and directed.
S&F for butt hinges 100mm medium weight cold rolled mild steel complete all as specified and directed.
S&F for butt hinges 75 mm medium weight cold rolled mild steel complete all as specified and directed.
S&F MS helical door spring including roller & roller plate complete 300 mm size complete all as specified and directed.
S&F 150 mm long floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring complete all as specified and directed.
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering complete all as specified and directed.
Supply and fixing 0.63mm thick galvanized corrugated mild steel sheet with two corrugation side lap fixed with ‘L’ or ‘J’ hooks as in roof covering complete all as specified and directed.
S&F Plain, galvanised, mild steel sheeting, 0.63mm thick in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) any thickness, including cover fillets complete all as specified and directed.
S&F anodised aluminium snap grid frame work for false ceiling size of grid 605x605mm all as specified with hangers 6mm dia GI wire (upto 1200mm length) adjusting level fixed to roof slab by means of ceiling cleats made out of GI flat 40x3 mm size 60 mm long complete all as specified and directed.
S&F for 10 mm thick PVC insulation panels with EPS stuck to 1 mm thick plain PVC sheet suitably placed in false ceiling grid made of aluminium GI/MS as per specification and drawing complete all as specified and directed.
M&L for kota stone slab flooring 20-25 mm thick over cement screed bed laid and jointed with grey cement slurry mixed with pigment to match th shade of the slab including rubbing and polishing laid over and including 15mm thick screed bed in cm (1:4) complete all as specified and directed.
All as per item No 74 above but on vertical surfaces of walls /skirting/dado in backing coat of 15mm thick in CM 1:4 complete all as specified and directed.
M&L new plastered surface and applying 3 mm thick wall care putty and two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified and directed.
M&L for Non skid ceramic coloured joint free tiles 7mm to 8mm thick (square/ rectangular), area of each tiles exceeding 0.11 sqm but n exc 0.18 sqm, in floor etc set and jointed in neat cement slurry and pointed in coloured cement to match the colour of tiles, laid over and including cement screed bed 15 mm thick in cement mortar (1:6) laying floor finish complete all as specified and directed.
Taking up or down 15mm bore GI Tubing and connections including cleaning for refixing or removal to store complete all as specified and directed.
Taking up or down 20 mm bore GI Tubing and connections including cleaning for refixing or removal to store complete all as specified and directed.
S&F 15 mm bore GI tubing med grade galvanised with all fittings and fixed complete to walls & floors etc complete all as specified and directed.
S&F 20 mm bore GI tubing med grade galvanised with all fittings and fixed complete to walls & floors etc complete all as specified and directed.
S&F in repairs 75mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S&F in repairs 110 mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S&F in repairs 75mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed on walls complete all as specified and directed.
S&F in repairs 110 mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed on walls complete all as specified and directed.
S&F 75mm PVC (SWR) bends any radius complete all as specified and directed.
S&F 110mm PVC (SWR) bends any radius complete all as specified and directed.
S&F 75mm PVC (SWR) vent cowl complete all as specified and directed.
S&F 110mm PVC (SWR) vent cowl complete all as specified and directed.
S&F in repairs tubular towel rail aluminium anodised 20mm dia, D type, 60 cm long between flanges incl brackets complete all as specified and directed.
S&F in repairs 40mm thick , 2nd class hardwood planks , planed one side with butt joints and fixed with nails complete all as specified and directed.
M&L in repairs for weather boarding in 2nd class softwood clean sawn complete all as specified and directed.
Dismantling of timber scantling 40 sq cm and over in section in any position in unframed complete all as specified and directed.
Dismantling of timber scantling 40 sq cm and over in section in any position in framed work complete all as specified and directed.
S&F of timber framed in second class soft wood clean sawn as in scantling etc. complete all as specified and directed.
M&L for two coats of synthetic enamel paint on new wooden surfaces over coat of pink primer including preparation of surfaces, over 10cm width or girth complete all as specified and directed.
M&L for one coat of synthetic enamel paint on OLD wooden surfaces including preparation of surfaces over 10cm width or girth complete all as specified and directed.
M&L for preparation of plastered or plastered OLD SURFACES of walls and applying two coats of cement base paint on walls (externally) including removal of existing treatment over a coat of alkali resistant priming paint complete all as specified and directed.
Complete removal of existing treatment of walls and applying two coats of oil bound distemper over 3mm thick layer of wall care putty complete all as specified and directed.
M&L for chequered cement concrete tiles glossy finish 20cm x20cmx25mm thick with grey cement and pigment , set , jointed and pointed in neat cement slurry in floors laid over and including 15 mm thick screed bed in cm 1:6 complete all as specified and directed.
M&L for 100 mm thick PCC 1:4:8, type D-2 using 40mm graded crushed stone aggregate as in sub base complete all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in hard dense soil complete all as specified and directed.
M&L PCC 1:3:6 type C2 using 40mm graded crushed stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
S&F 10mm thick MS Plates (plain or chequered) square cut or notched (ordinary and counter sunk) forming holes, welded including all necessary bolting or riveting etc with roof trusses Fe 410 -W Gde?E- 250)quality A complete all as specified and directed.
M&L Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and counter sunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
S & F for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet as in ridge, 0.50mm thick of any colour having tensile strength of not less than 550 Mpa as in roof covering/cladding to gabble sides/wall, fixed with self tapping machine GI screws full threaded complete all as specified and directed.
S&F for pre-painted galvalume aluminium zinc coating GI based plain steel sheets 0.50mm thick of an color having tensile strength of not less than 550 Mpa as in roof covering/cladding/ridge/ doors , fixed with self tapping screws complete all as specified and directed.
Surface excavation n exc 30 cm deep and averaging 15 cm deep and getting out complete all as specified and directed.
M&L for 75 mm thick PCC (1:3:6) type C2 (using 40 mm graded aggregate ) as in sub for receiving floor finishes etc. complete all as specified and directed.
M&L Machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade complete all as specified and directed.
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in coping, benching, haunching including form work complete all as specified and directed.
Returning, filling in incl spreading, levelling, watering and well ramming in layers n exc 25 cm thick complete all as specified and directed.
Removal of surplus soil n exc 50m and depositing where directed not exceeding 1.50 mtr above starting point complete all as specified and directed.
Taking down carefully aluminium point wiring (light, fan, socket or power, bell complete fitting such as sockets, ceiling roses, pendants, batten holders, regulators and making good the disturbed surfaces of wall, floors, ceiling in CM 1:3 etc. complete all as specified and directed.
M & L for point wiring complete for light/ fan on independent /combine board with cable 1.5 sqmm (Nominal area) FRLS PVC insulated multi stranded unsheathed copper conductor, drawn in PVC casing & capping and including pipe hooks , elbows, junction covers and junction boxes , after fixing or cutting on wall chasing for conduits and sinking's for sunken cast iron/ pressed steel terminal boxes 60mm deep, suitable length and thickness for mounting, switches, sockets, fan regulator with 3 mm thick plastic laminated sheet cover fixed with brass screwed and cup washers, duly fixed on wall or grouting and painted with red oxide primer and making the good disturbed surfaces of wall in CM 1:3 with white wash or existing colour including provision of continuous earth continuity conductor along with point wiring of 1.5 sqmm copper PVC insulated cable for one light/ fan point controlled by one switch and connected to common earth dolly, complete all as specified and directed.
All as per srl item No-116 here in above but for one 5A socket outlet on the same board controlled by one switch complete all as specified and directed.
All as per srl item No-116 here in above but for one 3 pin 5A socket outlet independent controlled by one switch complete all as specified and directed.
All as per item No 116 above but for 3 pin socket outlet 15 Amps independent board with 2.5 Sqmm copper PVC insulated cable complete all as specified and directed.
All as per srl item No-116 here in above but for One light Point controlled by two, two way switches complete all as specified and directed.
M&L for sub main wiring with two single core PVC insulated unsheathed , FRLS flexible copper conductor cable of size 6 sqmm and one single core PVC insulated unsheathed, FR flexible copper conductor cable of size 4.0 sqmm as earth lead in & including PVC casing / non metallic rigid PVC conduit medium grade, and making good the disturbed portion complete all as specified and directed. Note: two runs of 6 sqmm cable and one run of 4Sqmm cable including casing capping or conduit shall be measured as one unit for measurement and payment purpose.
S & F switch piano flush type 5/6 Amps single pole one way complete all as specified and directed.
S & F switch piano flush type Single pole, two way 6 Amp rating complete all as specified and directed.
S & F for Switch Socket combination, 6 pin 5 and 15 amps multi purpose 2 in 01 flush type, 230 volts complete all as specified and directed.
S & F for Switch Socket combination 2 in 1, 5 Amps flush type, 230 volts complete all as specified and directed.
S & F fan regulator Electronic type complete all as specified and directed.
S & F ceiling rose surface bakelite three terminals complete all as specified and directed.
S&F LED lights fitting 1x20W, 230V, AC decorative box type with drive, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
Taking down old Unserviceable Bldg Security light fitting and taken as credit including supply & Fixing 25W New generation energy saving & environment friendly long life Versatile pressure die-cast aluminium IP65 roadway luminaries with high power LED as light source along with suitable bracket incl all accessories complete all as specified and directed.
Taking down exhaust fan of any size after disconnecting the wire from existing ceiling rose and deposited to MES Store (AGE E/M Sub Divn) and supply & fixing exhaust fan, steel body, AC single phase 230/240 volts heavy duty of size 300mm sweep with blades, frame, louvers and all fixing arrangements complete all as specified and directed.
S & F Lamp holder insulated body with back plate for batten fittings complete all as specified and directed.
Supply and fixing of LED 9 watt pin type bulb complete all as specified and directed.
S&F LED light fitting mirror type with high out put diffuser 1x5Watt, 220V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F MCCB Distribution board, TP&N, vertical, double door, sheet steel, enclosure powder coated with 100 Amps rated bus bar with neutral link, 415 Volts 4 way fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete including 3 Pole V-Tec MCCB of 100 A rating & 16kA breaking capacity, MCCB pre-fitted at factory complete all as specified and directed.
Supply and fix MCB Distribution board , 240 volts single pole and neutral, double door, sheet steel, enclosure powder coated with 100 Amps rated bus bar with neutral link, 8 way, fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete all as specified and directed.
Supply and fix in replacement MCB SPN, 240 volts any rating from 40-63 amps, with rupturing capacity 10 KA, including providing thimble for outgoing cables complete all as specified and directed.
M&L for MCB single pole 240 volts 6 to 32 amps as per site requirement , with rupturing capacity 10 KA as per IS-8828-1996 (IEC-60898), disconnect upper and lower terminals , integrated label holder to ensure circuit identification.
Supply , laying and fixing testing cable XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volt grade of size 25 Sqmm 4 core complete all as specified and directed.
Supply , laying and fixing testing cable XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volt grade of size 35 Sqmm 3.5 core complete all as specified and directed.
M&L for sand cushioning in trenches for cable protection including consolidation and punning complete all as specified and directed. Note: Punned thickness shall be measured for payment purpose.
M&L for bricks laid in trenches flat with width equal to length of brick for cable protection well burnt sub class 'B' laid across the cable complete all as specified and directed.
S&F GI water tubing 40 mm bore, medium grade (ISI marked) laid in trenches incl all fittings as required at site complete all as specified and directed.
Supplying installing, commissioning testing in repairs LT cubical feeder pillar box out door kiosk type made out of CRCA sheet 3.15mm, 3 phase 4 wire 50 C/S AC with aluminium bus bar of 250 Amps rating fixed on insulators for incoming & outgoing taping complete double door type with locking arrangement fixing on PCC platform with suitable nuts, bolts dully painted with two coats of synthetic enamelled paint over a coat of red oxide primer, comprising with MCCB 160 Amps TPN 50Hzs, 35KA (01 Nos) in coming and MCCB 100 Amps TPN, 25 KA (01 Nos), MCB40 Amps SPN C curve (02 Nos) cable for service connection complete all as specified and directed. Make : Havells/Legrand/L&T
Material & labour for earthing complete with galvanised cast iron earth plate electrode of size 600x600x6.0mm thick busied directly in ground less than 2.25mtr deep below normal ground level as earth electrode with top edge of the earth plate not less than 1.5mtr below normal ground level, continuity conductor 4mm dia GI wire connected to earth plate by means of welding, GI thimbles, nuts, bolts & washers all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover with handle of angle iron frame of size 40 x 40 x 6mm in PCC 1:3:6 adequate quantity of charcoal dust and salt all around the earth plate, earth work in any type of soil and removing remaining surplus excavated material all as required at site and specified in EP No 3 of SSR part I 2009 complete all as specified and directed. (i) Main earthing lead from earth plate electrode to test point up to length of 7.5 meters length shall be deemed to be included in the unit rate quoted against this item . (ii) GI protection pipe & earthing lead beyond 7.5 meter shall be measured and paid for separately under appropriate item of Sch A part-IV (Sec-I) . (iii) On testing after completion if the desired resistenance is not obtained the contractor shall redo the earthing without any extra cost to the department .
Material & labour for earthing complete with galvanised cast iron earth plate electrode of size 600x600x6.0mm thick busied directly in ground less than 2.25mtr deep below normal ground level as earth electrode with top edge of the earth plate not less than 1.50mtr below ground level using GI strip 32x6 mm dia as earth continuity conductor connected to earth plate by means of welding, GI thimbles, nuts, bolts & washers all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover with handle of angle iron frame of size 40 x 40 x 6mm in PCC 1:3:6 adequate quantity of charcoal dust and salt and all around the earth plate, earth work in any type of soil remaining surplus excavated material all as required at site and specified in EP No 3 of SSR part I 2009 or directed by Engineer-in-charge and incl testing on completion. (i) Main earthing lead from earth plate electrode to test point up to length of 7.5 meters length shall deem to be included in the unit rate quoted against this item .(ii) GI protection pipe & earthing lead beyond 7.5 meter shall be measured and paid for separately under appropriate item of Sch A part-IV (Sec-I). (iii) On testing after completion if the desired resistenance is not obtained the contractor shall redo the earthing without any extra cost to the department .
M/S SHEIKH FEROOZ AHMAD
M/S STARE BUILDERS
M/S KHAN CONSTRUCTION COMPANY (KCC)
BHAT CONSTRUCTIONS AND BUILFERS
Concept Engineering & Constructions
RASHID CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .