| 1 | L1₹54.9 LAccepted-Finance | L1 | Accepted-Finance as per financial evaluation | |
| 2 | L2₹61.2 L+₹6.3 L (11.5%)Rejected-Finance | L2 | Rejected-Finance as per financial evaluation | |
| 3 | L3₹62.9 L+₹8.1 L (14.7%)Rejected-Finance | L3 | Rejected-Finance as per financial evaluation | |
| 4 | L4₹63.5 L+₹8.6 L (15.6%)Rejected-Finance | L4 | Rejected-Finance as per financial evaluation | |
| 5 | L5₹66.7 L+₹11.8 L (21.5%)Rejected-Finance | L5 | Rejected-Finance as per financial evaluation |
Tender Value
₹70.5 L
EMD Value
₹1.8 L
Closing Date
16 Oct 2025, 3:00 pmClosed
SA, ASI, Patna Circke, Patna
JC Road Antaghat Patna-800001
as per tender document
2025_ASI_879382_1
G-20/May/25/21965914/NAP
Open Tender
Job Works
Works
30 days
Nalanda
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
Yes
SA ASI
₹1.8 L
Yes
11 Nov 2025
26 Sept 2025
17 Oct 2025
27 Sept 2025
16 Oct 2025
27 Sept 2025
Amount
Purchase & installation of 01 No. 125 KVA DG Set.:-SITC of 125 KVA, 415V, 50Hz, 3Ø silent DG Set, comprising of Engine, alternator, separate AMF panel, Base frame, Fuel tank, Battery, CPCB-II approved Engine, Acoustic Enclosure & necessary control cables for connection with AMF Panel including transportation, loading and unloading of the DG set arrangements in termination box suitable UP to 3.5 x 400 sq mm aluminium cables with all other associated equipment/ work as per specifications. As per CBCB latest Norms.
Main LT Panel (indoor Type):- SITC of MAIN LT PANEL (Indoor Type)Supplying, installation, testing & commissioning of cubicall type LT panel suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system fabricated in compartmentalized design from CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland, plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade. As per technical specifications (A) MAINLTPANEL 1. 250A, 4P, MCCB (LCD Display With Current Metering), Incomer-1 2. 150A, 4P, MCCB (LCD Display With Current Metering), Incomer-2 3. Under Voltage Release (MN), 380/ 480VAC 4. MECH. I/L – LOCK & KEY LOCK (1K+1L) + M.KIT 5. Multifunction Meter 6. Aux. Contact, 2NO + 2NC 7. Bus Bar 300 Amp Aluminium 8. Bus Bar 200 Amp Aluminium (B) BUSCOUPLER 1. 250A, 4P, MCCB (LCD Display With Current Metering), Incomer-1 2. Under Voltage Release, 380/480 VAC 3. MECH.I/L-LOCK & KEY LOCK(1K+1L)+M.KIT 4. Aux. Contact Block, 2NO+2NC 5. 50A disconnecting type Neutral Link (C) OUTGOINGS-MUSEUM BUILDING TO UPS 1. 150A, 4P, 36kA, MCCB with TM Release 2. Standard Extended rotary handle for 400A 3. 50A disconnecting type Neutral Link (D) To HVAC DB 1. 150A, 4P, 36kA, MCCB with TM Release 2. Standard Extended rotary handle for 400A 3. 50A disconnecting type Neutral Link (E) Spare 1. 100A, 4P, 36kA, MCCB with TM Release 2. Standard Extended rotary handle for 100A 3. 50A disconnecting type Neutral Link (F) APFC Panel:- 1. 150A, 4P, 36kA, MCCB with TM Release 2. Standard Extended rotary handle for 300A 3. 50A disconnecting type Neutral Link (H) IMMERSIVE BUILDING TO UPS:- 1. 100A, 4P, 36kA, MCCB with TM Release 2. Standard Extended rotary handle for 400A 3. 50A disconnecting type Neutral Link (I) To HVACDB:- 1. 100A, 4P, 36kA, MCCB with TM Release 2. Standard Extended rotary handle for 400A 3. 50A disconnecting type Neutral Link (J) Spare:- 1. 100A, 4P, 36kA, MCCB with TM Release 2. Standard Extended rotary handle for100A 3. 50A disconnecting type Neutral Link 4. 100A, 4P, 36kA, MCCB with TM Release 5. Standard Extended rotary handle for 300A 6. 50A disconnecting type Neutral Link
Distribution Board:- (A) Supply, installation, testing, tagging, (Circuit numbering) & commissioning of following double door readymade recessed type MCCB, DB, fabricated out of CRCA sheet and painted with powder coating process OR made out of scratch proof polycarbonate body, & concealed in wall, or on surface with necessary frame complete as required.8 WAY TPN, 1 no. of 150A4P MCCB as in comer, 7 no. of 63ATPNP MCB as outgoing. (B) Supply, installation, testing, tagging, (Circuit numbering) & commissioning of following double door readymade recessed type MCCB, DB, fabricated out of CRCA sheet and painted with powder coating process OR made out of scratch proof polycarbonate body, & concealed in wall, or on surface with necessary frame complete as required. 1 no. of 150 ATP NMCCB as incomer, and 3 no. 63 amp DP RCCB, 22 no. of 32A SP MCB as outgoing (B) 8way (4 + 24), Double door (C) Supply, installation, testing, tagging, (Circuit numbering) & commissioning of following double door readymade recessed type MCCB, DB, fabricated out of CRCA sheet and painted with powder coating process OR made out of scratch proof polycarbonate body, & concealed in wall, or on surface with necessary frame complete as required.16 WAY SPN, 1 no. of 100A4P MCCB as incomer , 13 no. of 32 ASP MCB as Supply, installation, testing, tagging, (Circuit numbering) & commissioning of following double door readymade recessed type MCCB, DB, fabricated out of CRCA sheet and painted with powder coating process OR made out of scratch proof polycarbonate body, & concealed in wall, or on surface with necessary frame complete as required.1no.of 100A TPN MCCB as incomer, and 3 no.63 amp DP RCCB, 23 no. of 32A SP MCB as outgoing. (D) 8 way (4+24), Double door
APFC Panel 55 KVAR :- (A) Supplying, installation, testing & commissioning of cubical type floor/wall mounted auto/manual power factor correction system of 55 KVAR capacity in having 3 phase MPP super heavy duty resin bonded, low loss, terminal less capacitors without oil, housed in aluminium cans power capacitors, each capacitor provided with suitable rating Thyristor switch, copper inductor coils (14% detuned reactors), semiconductor fuse and suitable for 433V, 3 Phase, 4Wire, 50 Hz AC supply system, fabricated in compartmentalized design from CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland plates i/c cleaning & finishing complete with 7 tank process and powder coating in approved shade. (B) Automatic power factor intelligent monitoring relay (microprocessor) to sense and monitor the system power factor and provide impulses for operation of 6 sequential capacitor circuits. The system shall have step display mode real time power factor control with 14% anti harmonic block reactors, microprocessor based power factor controller, for target PF setting and having LED display, with first mode showing V, I, PF, shortfall KVAR, KW on the screen continuously without scrolling & in second mode the controller should show actual KVAR activated, KVA in every second & actual PF (in 30-40 mili seconds). Dedicated fan should be provided for forceful cooling of the Thyristor. (C) MPP Super Heavy duty 3 phase capacitors suitable for operation on 433V, 50 Hz as per following configuration. Each capacitor shall be provided with thyrister switching module and 14% harmonic block reactors. The rating of the switching module and harmonic block reactors shall be confirming to rating of respective capacitors. Each bank of capacitor shall be provided with semiconductor fuse and fuse.
APFC Panel 30 KVAR:- (A) Supplying, installation, testing & commissioning of cubical type floor/ wall mounted auto/manual power factor correction system of 30 KVAR capacity in having 3 phase MPP super heavy duty resin bonded, low loss, terminal less capacitors without oil, housed in aluminium cans power capacitors, each capacitor provided with suitable rating Thyristor switch, copper inductor coils (14% detuned reactors), semiconductor fuse and suitable for 433V, 3 Phase, 4 Wire, 50 Hz AC supply system, fabricated in compartmentalized design from CRCA sheet steel of 2 mm thick for frame work and covers, 3mm thick for gland plates i/c cleaning & finishing complete with 7 tank process and powder coating in approved shade. (B) Automatic power factor intelligent monitoring relay (microprocessor) to sense and monitor the system power factor and provide impulses for operation of 6 sequential capacitor circuits. The system shall have step display mode real time power factor control with 14% anti harmonic block reactors, microprocessor based power factor controller, for target PF setting and having LED display, with first mode showing V, I,PF, shortfall KVAR, KW on the screen continuously without scrolling & in second mode the controller should show actual KVAR activated, KVA in every second & actual PF (in 30-40 mili seconds). Dedicated fan should be provided for forceful cooling of the Thyristor. (C) MPP Super Heavy duty 3 phase capacitors suitable for operation on 433V, 50 Hz as per following configuration. Each capacitor shall be provided with thyrister switching module and 14% harmonic block reactors. The rating of the switching module and harmonic block reactors shall be confirming to rating of respective capacitors. Each bank of capacitor shall be provided with semiconductor fuse and fuse
Safety equipments (1) Supplying & fixing or Rubber matting of 12 mm thick, 1 Mtrs wide suitable for voltage of 1.1 KV etc. as required. 20 Sqr, Mtr (2) Supplying & fixing of Shock treatment chart printed in atle;ast three languages i.e, Hindi, English and a local language fitted in wooden Frame and glass at front side and hard board at back side etc. 1 No. (3) Providing & fixing of MV/ HV Danger Notice Plate of 200mm x 150 mm, made of mild steel at least 2mm thick and vitreous enameled, white on both side & with inscription in signal red colour on front side as required 1No. (4) Strong grip Comfortable Rubber Insulating Seamless Hand Safety Gloves. High tear resistance. Salisbury Insulating Rubber Gloves. Proper fit is import ant to minimize chafing and fatigue., especially with thermal liners. In Type Natural Rubber only. The gloves meet or exceed ASTM D120 and IEC EN60903 Standards. 1No. (5) Supplying and fixing of carbon dioxide type fire extinguisher 4.5kgs. Capacity of approved make with wall mounting bracket (Push type) as required conforming to IS: 15683-2006 (Latest amended). 1No. (6) Material In The Box First Aid Box- Scissors 01, Snake bite lancet 01, Wound Cleaning antiseptic wipes 30, Tincture – Providence Wipes 20, Cotton Wool- 15, gm. 03, Adhesive plaster – small 02, Small Sterilized dressing 06, Medium sterilized dressing 06, Large Sterilized Dressing 06, Steroids Eye pad in shield packet (Dressing) with elastic dressing roll 05,Tourniquet01,Safetypins 24, Roller bandage- medium 5 cm wide x 2mtr.05, Roller bandage- medium 10 cm wide x 2mtr. 05, Triangular bandage 04, Burn ointment 01,Cpr mask 02, Instant cold pack 02, Adhesivebandages16, Burn/ rescue blanket 01, Disposable gloves(1pair)01, Muscle relaxant ointment 01, Gauze pad – 5, cm 03, Gauze pad- 7.5 cm 03 -01 No.
Earthing system:- (1) Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required – 04 Nos. (2) Providing & fixing of 25mm x 6mm GI strip on surface or recess for earth connection as required.- 40 Mtr. (3) Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.- 50 Mtr (4) Providing and installation of Chemical Earthing of Length 3.00mtr, 25mm dia, Hightensile – low carbon steel rod bonded by high conductivity copper on outer surface as per IEC62561-2, including universal clamp and cover including all required items. Test report to be provided along with earth electrod for short circuit current testing , Copper coating thickness, Electrical resistivity test as per IEC625612, test report for corrosion- 4 Set (5) Providing and fixing 50mm X 6mm copper strip on surface or in recess for connections etc. as required.- 20 Mtr
Lightening arrester :- (A) Advanced ESE Type Lightning Arrester: * Make: Saturn | Model No: C60 At = 60us * Very high–grade stainless-steel material body with pointed tip. * Tested & certified by CPRI, Bengaluru against Lightning Impulse Current with stand test 8/20 us (70KA). * Avg. Protection radius at 6m height up to 108 Mtrs (level-III) * As per International Standard NFC 17- 102:2011
(B) 25 meter 3 Legged self - supported Tripod tower] high support structure for Lightning Protection Air Terminal fabricated out of GI pipe along with base plate, Guy wire clamping system, termination arrangement for the down conductor complete as required
(C) 06 Digit Lightning Strike Counter Lightning strike counter working electro mechanically without any power supply complete as required
(D) Down conductor and accessories: * Copper Cable (PVC Coated, 70sq.mm Make: MESCAB) * Accessories include: PVC Pipe & Sleeve, Saddles, Clamp sand wall mounting materials, etc. (For connection between roof top arrestor, Earthing Terminal)
(E) KP Brand Safe Earthing System: * Model: KP317 (Set Length : 3metres, Dia - 17.20mm): 1No (Tested & certified by CPRI, Bhopal at 70 KA) * BFC Powder–for backfilling of the Earth Pit: 02 Bags (BFC Powder tested By NABL Accredited lab)
(F) Transportation, Installation & Final Testing Charges: * Mounting/Welding & Fixing Roof Top Arrestor on GI Stand * Laying of Down Conductor vertically downward from top to bottom (Earthing Point) * Making platform for GI Stand (Plinth Base) arrangement * Connection of Down Conductor to roof top arrestor & the Earthing terminal. * Transportation of Material at site, Supervision & Final Testing.
CHANDRA BHUSHAN SINGH (BID ID -3299341)
M/s.K.P.Enterprises (BID ID -3294617)
LAPANI PROGRESSIVE Pvt. Ltd (BID ID -3296162)
M/S LIGHT PALACE (BID ID -3298062)
SAURAV KUMAR CHOUDHARY (BID ID -3299735)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 8.61 MB
BOQ_924327.xls
BOQ • 0.31 MB
ELECTRIC.pdf
Tender Documents • 8.60 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .