| 1 | L1₹2.3 CrAccepted-AOC | ₹2.3 Cr | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹2.5 Cr+₹14.2 L (6.05%)Rejected-Finance | ₹2.5 Cr+₹14.2 L (6.05%) | L2 | Rejected-Finance being not lowest |
| 3 | L3₹3.2 Cr+₹90.1 L (38.5%)Rejected-Finance | ₹3.2 Cr+₹90.1 L (38.5%) | L3 | Rejected-Finance being not lowest |
| 4 | L4₹3.3 Cr+₹92.5 L (39.5%)Rejected-AOC 20 SC BOSE COLONY GALL NO 2 DEFENCE LAB ROAD RATNADA JODHPUR 342001 | JODHPUR | JODHPUR | RAJASTHAN | 342001 | ₹3.3 Cr+₹92.5 L (39.5%) | L4 | Rejected-AOC Being Not Lowest |
| 5 | L5₹3.3 Cr+₹93.3 L (39.9%)Rejected-Finance | ₹3.3 Cr+₹93.3 L (39.9%) | L5 | Rejected-Finance being not lowest |
Tender Value
₹2.7 Cr
EMD Value
₹3.5 L
Closing Date
22 Apr 2023, 6:00 pmClosed
CE (AF) GANDHINAGAR
LEKHAWADA PATIA CHILODA GANDHINAGAR 382042
ADDN ALTN IMPROVEMENT TO HANGER DOORS, ROLLING SHUTTERS, STEEL GATES AND ROOFING SHEET AT AF STATION JAISALMER
2023_MES_584228_1
81215
Open Tender
Civil Works
Item Rate
365 days
GE (AF) JAISALMER
ALL AS PER NIT AND TENDER DOCUMENTS
9 documents required · 9 mandatory
₹2,000
GE (AF) JAISALMER
₹3.5 L
Yes
13 May 2023
3 Mar 2023
25 Apr 2023
3 Mar 2023
22 Apr 2023
5 Apr 2023
4 Mar 2023 - 20 Mar 2023
Amount
Buildings including Internal Services
Taking down existing unserviceable rolling shutter complete of any size and any type and removing from site, complete all as specified and directed
Demolition of brickwork or stone/boulder/PCC block masonry, built in cement mortor including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified and directed
Demolition of plain cement concrete in ground floors and pavings n exc 15cm thickness (below or above ground level) incl disposing off the debris out of MOD land complete all as specified and directed
Dismantling structural steel work including door gate etc of any description not otherwise provided for complete all as specified and directed
Dismantling Plain or corrugated steel sheeting / Fiber glass reinforced translucent sheet, any gauge, thickness, including Nainital or similar pattern roof covering complete all as specified and directed
Dismantling Asbestos cement ( corrugated or semi corrugated , etc) sheets any gauge, thickness, roof covering complete all as specified and directed
Taking down the sliding steel Hangar Doors, Area of each shutter not exc 20sqm, with mechanical crane without damaging existing structure, straightening of worn out top and bottom rails,replacing the loose nuts and bolts,necessary welding, locking arrangement and greasing/ oilling to bearings of each rollers, top/bottom wheels, gear mechanism, steel chains, cleaning bottom and top rails etc and positioning / refixing of door shutter in same position opening and ensure smooth and free operation of hangar doors/steel doors complete all as specified and directed Note : (S & F for damaged major spare/parts is not included in this item and same shall be measured and paid sepertely)
Ditto all as in Sl Item No 7 above but area of each shutter exc 20sqm Note : (S & F for damaged major spare/parts is not included in this item and same shall be measured and paid sepertely)
S&F in repair bottom wheel made up of mild steel conforming to IS 2062 Fe 410 of 250mm dia 85-100mm thick including necessary cutting of surclip groove, bearing groove complete all as specified and directed
S&F in repairs top wheel made up of taflon/cast iron wheel of hangar doors/steel gates including fixing only of ball bearings (qty -02 Nos), 01 Nos shaft of dia 25mm and 120mm long as per requirement at site including necessary welding, drilling and other fittings as required etc complete all as specified and directed.
S&F in repairs gear system suitable for Hangar doors/steel doors complete all as specified and directed.
S&F in repairs MS chain of size 20mm x 20mm and 1.50 to 2.00m long complete all as specified and directed.
S&F in repairs bottom sprocket attached wheel of 200-300mm dia complete all as specified and directed.
S&F in repairs stainless steel ball bearings roller of existing make 100mm x 60mm as per site requirement complete all as specified and directed
S&F in repairs stainless steel ball bearings roller of existing make 60mm x 40mm or as per site requirement complete all as specified and directed.
S&F in repair MS Flat iron handle of 500mm long suitable for operating hangar door/steel doors complete all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out, returning,filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering and removing surplus soil to a distance n exc 50m and making good surface complete all as specified and directed
M & L Hardcore with broken stone and boulder of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15cm thick,watered and rammed to a true surface complete all as specified and directed
M&L for cement concrete 1:3:6 type C2 (40mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed
M&L PCC 1:4:8 type C2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and directed
M&L for pre-cast cement concrete Type C1 1:3:6 (20mm graded stone aggregate) solid block masonry exc 10cm in width and setting in CM 1:6 complete all as specified and directed
M&L for square rubble walling Jodhpur type brought up to courses well bonded, bedded and solidly hearted in cement mortar 1:6 complete all as specified and directed
S&F mild steel conforming to Fe-290 Gde E-165 as in wind ties to roof including securing bolts, flat iron fillets etc complete all as specified and directed.
Taking down cement plaster on brick or stone wall etc including raking out joints hacking for key scrubbing down with water etc incl disposing off the debris out of MOD land complete all as specified and directed
S&F in repair 1.25mm thick mild steel plain black sheet in wall cladding, steel gates and similar work cut to size, holes punched, including round headed screws or rivets and fixed by welding to steel framing with plain 40mm lap joints or riveted or welded seams, including bending or turning up, mitred angles etc as required complete all as specified and directed
M&L for mild steel conforming to Fe-410-W(Gde E-250) rolled sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates complete all as specified and directed
M & L Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed
S&F for Steel work in tubular trusses using hollow tubular/ square/ rectangular pipes including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed
M&L for prepration of old decorated wall surface of any description and applying one coat of Oil Bound Distemper of any tint complete all as specified and directed
S & F pull push or manual type complete steel rolling shutter with thickness of laths 1.25 mm including top cover, anchoring rod, hasp and staple and one shop coat of primer and erect in position complete all as specified and directed
S & F gear operated type with bevel gear box and crank handle Steel rolling shutter with thickness of laths 1.25 mm including top cover, anchoring rod, hasp and staple and one shop coat of primer and erect in position complete all as specified and directed
Running welding in repairs, thickness of metal to be welded exc 6 mm but n exc 9mm complete all as specified and directed
S & F in repairs 40 mm dia bore M S Pipe medium grade for rolling shutter for smooth functioning of old rolling shutter complete all as specified and directed
Ditto all as in Sl Item No 33 above but 50 mm bore.
S & F in repair steel spring of suitable size for old rolling shutter and including smooth functioning complete all as specified and directed
S & F in repairs in rolling shutters top cover fabricated to required shape and size made out of 1.00 mm (20 gauge) thick M S sheet including necessary fixtures and fastening with one shop coat of redoxide primer, of length upto 3.00 Mtr complete all as specified and directed
S&F 2mm thick Fibre glass reinforced translucent corrugated /plain sheeting with two corrugations side lap fixed with L-type or J-type or cranked hook bolts and washer in lieu of screw in roof, wall etc complete all as specified and directed
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.60mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed
S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.60mm thick of an colour having tensile strength of 550 Mpa as in roof complete all as specified and directed
M&L for 100mm thick PCC M-20 (20mm graded stone aggregate) as in floors finishing surface of concrete pavement with broom finish complete all as specified and directed
M&L for 15mm thick plaster in CM 1:4 on concrete surfaces and finished even and smooth without using extra cement complete all as specified and directed
M&L for preparation of newly plastered surfaces and applying two coats of cement based paint of approved tint over a coat of primer complete all as specified and directed
M&L for preparation of old painted steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthethic enamel paint in one or more tints as required in camouflage pattern etc complete all as specified and directed.
M&L for preparation of old painted steel surfaces of any description, not over 10cm in width or girth, not otherwise described and applying two coats of synthethic enamel paint in one or more tints as required in camouflage pattern etc complete all as specified and directed.
M&L for preparation of new steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthethic enamel paint in one or more tints as required in camouflage pattern over a coat of red oxide primer etc complete all as specified and directed.
S&F in steel Air exhaust turbo ventillators driven by natural wind mounted on roof top with exhaust 600mm size complete all as specified and directed
S&F Collapsible steel gates, top hung,consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complete all as specified and directed
S&F Mild steel guard bars ,plain,let in and fixed independently in frames as specified conforming to Fe-290 Gde E-165 complete all as specified and directed
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing, serviceable tiles to store and rubbish off the premises complete all as specified and directed
M&L for glazed coloured ceramic tiles in vertical surfaces 300 x 200 x 6-7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick rendering in CM 1:4 on other then fair faces of brick work or concrete surfaces etc complete all as specified and directed
M&L vitrified ceramic tiles light shade 9-10 mm thick (square / rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:6 etc complete all as specified and directed
All as per item No.51 but as in skirting, dados etc over 10mm thick rendering in CM 1:4
M&L for non skid coloured ceramic tiles 7 to 8mm thick (square or rectingular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:6 etc complete all as specified and directed
M&L for non skid coloured ceramic tiles 7 to 8mm thick (square or rectingular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:6 etc complete all as specified and directed
M&L for non skid coloured ceramic tiles 7 to 8mm thick (square or rectingular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:6 etc complete all as specified and directed
M&L Hard drawn steel wire fabric cut to lengths, bent to shape required and tying with and including mild steel wire(annealed) not less than 0.9mm in dia supplied and fixed weight per Sqm n exc 4kg/sqm complete all as specified and directed
Dismantling wall and ceiling board (fibre, pulp, insulation etc or insulation boards/ slabs/ blankets) any thickness including cover fillets and removing old hangers complete all as specified and directed
S & F GI frame work for seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/ intermediate channel 0.9mm thick having two equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel at 457mm centre to centre, size of grid 605 mm x 605mm complete all as specified and directed
S &F Hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long complete all as specified and directed
S &F PVC false ceiling board, 595 x 595mm, 7 to 9mm thick, fixed in the grid complete all as specified and directed Note : Frame work for ceiling shall be measured and paid separately
M & L for Reinforced cement cocrete 1:2:4 type B1 (20mm graded stone aggregate) as in foundations, including rafts,footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs,under-reamed piles and mass concrete complete all as specified and directed
M & L for Reinforced cement cocrete 1:2:4 type B1 (20mm graded stone aggregate) in Columns, pillars, piers, posts and struts concrete complete all as specified and directed
M & L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams,sides and soffits (if any) of foundation and plinth beams;and similar work; vertical or to batter rough finished surface flat complete all as specified and directed
M & L for Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
M&L PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in coping, benching etc incl necessary form work complete all as specified and directed
M&L for 18-20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including rounding of edges complete all as specified and directed
Dismantling structural steel work framed truss Span exc 10m but nexc 15m complete all as specified and directed
Dismantling posts or struts (wood,steel or RCC) any section including taking down embedded portion and making good disturbed ground post embed in concrete etc complete all as specified and directed
Dismantling timber scantling in fillets, rails, posts, rafters, purlins etc under 40Sqcm in section complete all as specified and directed
S&F rolled mild steel in roof trusses, (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee,angle,channel or flat sections) including distance pieces, cleats etc conforming to Fe-410-W Gde E-250 quality A complete all as specified and directed.
S & F 2.8mm thick Polycarbonate sheet fixed in any type of frame with self tapping screws/ addessive chemical/ beadding complete all as specified and directed
HANGAR DOOR REPAIR
Dismantling the Hangar door motor, gear, mainwheel, balancing wheel, chain spocket, chain of any sizes including opening/cutting existing hangar door of any size and refixing the new items including spring loaded gear assy for auto tighten the chain, lathe work, nut, bolt, washers, welding, cleaning of rail, grinding where required, oiling and greasing or any other work required for smooth functioning of the electrically operated doors complete all as specified and directed. Note : New items like motor gear, chain, main wheel, balancing wheel, coupling etc. shall be measured and paid seperately.
Servicing of 3 phase induction motor of capacity 1 to 2 HP, 960 RPM, 50 Hz including greasing, oiling, change of motor bearing and re-winding if required and two coat of super enammeled paint complete all as specified and directed.
Supply and fixing in replacement of motor control panel made out of CRCA sheet of minimum 2mm thickness powder coated IP-65 protection with provision of cable entry from bottom and top canopy shape with forward starter with push button - 02 Nos, reverse starter with push button - 02 Nos, MCB TPN of capacity 32 Amp - 01 No, contactors of capacity 32 Amp - 04 No complete all as specified and directed.
Supply and fixing in replacement of roller chain spoket pully set 4" for main hangar door wheel complete all as specified and directed.
Supply and fixing in replacement of roller chain spoket pully set 2" for main hangar door wheel complete all as specified and directed.
Supply and fixing in replacement of roller chain heavy duty suitable for hangar door wheel complete all as specified and directed.
Supply and fixing in replacement of Gear box with assembly complete type 2.25, ratio 20:1 suitable for hangar door complete all as specified and directed.
Supply and fixing of star coupling set No 100, suitable for 2 HP motor and gear type 2.25 of ration 20:1 complete all as sepcified and directed.
Supply and fixing of cable carrier including suitable size stranded steel wire for mounting of cable carrier complete all as specified and directed.
Supply and fixing in replacement of multistranded copper conductor cable of size 3 core 2.5 Sqmm complete all as specified and directed
Lighting Protection
M&L for earthing complete with copper earth plate electrode 300 x 300 x 3.15 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr deep below GL with top edge of the plate not less than 1.5 mtr below normal GL and connected to earth plate surrounded by 15cm thick packed layers of charcoal dust and common salt and connected to copper earth lead of size 20 x 3mm by means of bolts, nuts check nuts and washers of copper connected to test point and protected by galvanised iron pipe medium grade 40 mm bore and water pipe 20mm bore GI light grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No 5 of MES schedule Pt-I of 2009 complete all as specified and directed Note : (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM weighting not less than 4 Kg/Sqmm in lieu of CI cover. (ii) Rates of Excavation, earthwork, PCC pit & RCC cover deemed to be included in the quoted rate. (iii) Copper strip upto 7.5 mtr length shall be deemed to include in this item rate. (iv) If the test results of the earthing for the desired earth resistance is not obtained on testing after completion, the earthing will be redone at no extra cost by the contactor
M&L for Air termination, single pointed, copper rod 12mm dia and 300mm long complete all as specified and directed.
M&L for Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed
M&L for Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground.
Supply and fixing of 25mm dia bore galvanized iron tubes light grade with all fittings complete all as specified and directed.
M&L for PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in coping, benching etc incl necessary form work complete all as specified and directed
M&L for Plates (plain or chequered) FE 410-W( Grade E-250 quality A), channels, square cut or notched (ordinary and counter sunk) forming holes,without any attachement complete all as specified and directed
M&L for copper strip 32 x 6mm with saddles and fixing screws etc. saddles and fixing screws etc. conductors above ground complete all as specified and directed
Internal Electrification
Taking down carefully copper /aluminium point wiring light/fan, socket or power point complete including fittings such as switches, sockets, ceiling rose, bell push bell buzzer lamp holder bracket etc removing from site and making good disturbed surface of wall, floor etc as existing complete all as specified and as directed..
Taking down submain wiring including earth wire and making good distrubed surfaces to match with the existing surface roof/wall/floor including removing rubbish from site complete all as specified and as directed.
Taking down carefully unserviceable main switches, DB including MCB's complete of any size and capacity complete all as specified.
M&L Point wiring with 1.5 Sqmm copper conductor cables (multistranded) FRLSH PVC insulated and unsheathed in and including concealed PVC conduit (ISI marked) 25mm dia with sunk cast iron/pressed steel terminal box of adequate size with 3mm thick plastic laminated sheet cover for one light point/fan point/Bell point controlled by one, one way switch including continuous 1.5 Sqmm copper conductor (multistranded) FRLS PVC insulated and unsheathed cable connected to earth doly conforming to IS-694 including cutting, chases in wall and making the disturbed surface to match with the existing surface and colour complete all as specified and directed
All as per item No. 93 here in before but point wiring for one 3 pin socket outlet 5 Amps on the same board with other switches.
All as per item No. 93 here in before but point wiring for one 3 pin socket outlet 5 Amps independent
All as per item No. 93 here in before point wiring but for one 5 pin socket outlet 15 Amp and 5 Amp Multipurpose independent using 2.5 Sqmm copper conductor cable (multi-strand) FRLSH PVC insulated and unsheathed cable and 1.5 sqmm copper (multistrand) FRLSH PVC insulated and unsheathed earth wire with terminal box of size 175mm x 100mm x 3.15mm complete all as specified and directed
S&F of switch piano flush button type, 6 Amp, single pole one way complete all as specified and directed.
S&F of switch socket combination 2 in 1, 6 Amps multipurpose, flush type complete all as specified and directed.
S&F of ceiling rose, 3 terminals, PVC/Polycarbonate, isolated body complete all as specified and directed.
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one Double pole MCB 20 Amp complete all as specified and directed
S&F of Electronic fan regulator, flush mounting 300-400 Watts, having 4 step to regulate/ control speed of ceiling fan complete all as specified and directed
M&L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr deep below GL with top edge of the plate not less than 1.5 mtr below normal GL and connected to earth plate surrounded by 15cm thick packed layers of charcoal dust and common salt and connected to earth lead GI 4mm dia by means of bolts, nuts check nuts and washers of galvanized iron or steel and thimbles and other end of the earth wire connected to DB and protected by galvanised iron pipe medium grade 15mm bore and water pipe 20mm bore GI light grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No 5 of MES schedule Pt-I of 2009. Note : Note : (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM weighting not less than 4 Kg/Sqmm in lieu of CI cover. (ii) Rates of Excavation, earthwork, PCC pit & RCC cover deemed to be included in the quoted rate. (iii) If the test results of the earthing for the desired earth resistance is not obtained on testing after completion, the earthing will be redone at no extra cost by the contactor
M&L Wiring for circuit/submain wiring alongwith earth wire of the sizes 2 x 2.5 Sqmm + 1 x 2.5 Sqmm FRLSH PVC insulated copper conductor, single core cable drawn through and including concealed PVC conduit of suitable size as required including cutting, chases in wall and making the disturbed surface to match with the existing surface and colour complete all as specified and directed Note : All runs of cables ,1 run of conduit & chases shall be measured and paid as one metre length of unit
M&L Wiring for circuit/submain wiring alongwith earth wire of the sizes 2 x 6 Sqmm + 1 x 6 Sqmm FRLSH PVC insulated copper conductor, single core cable drawn through and including concealed PVC conduit of suitable size as required including cutting, chases in wall and making the disturbed surface to match with the existing surface and colour complete all as specified and directed Note : All runs of cables ,1 run of conduit & chases shall be measured and paid as one metre length of unit
Supply and fixing of DB SPN 8 way, 240V, double door complete all as specified and directed
Supply and fixing LED lights fitting 1x 18W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed
Supply and fixing of DB TPN 4 way, 415V, double door complete all as specified and directed
S&F MCCB FP, 125 Amp, 415 volt, with breaking capacity 16 KA complete all as specified and directed.
S&F MCB SPN 40-63 Amp, 240 volt, 10KA 'C' curve with connection testing commissioning complete all as specified and directed.
S&F MCB SP 6-32 Amp, 240 volt, 10KA 'C' curve with connection testing commissioning complete all as specified and directed.
Supply and fixing LED flood light 120W 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed
Supply and fixing Triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB 63 Amp complete all as specified and directed.
M&L Wiring for circuit/submain wiring alongwith earth wire of the sizes 4 x 10 Sqmm + 1 x 10 Sqmm of FRLSH PVC insulated copper conductor, single core cable drawn through and including concealed PVC conduit of suitable size as required including cutting, chases in wall and making the disturbed surface to match with the existing surface and colour complete all as specified and directed Note : All runs of cables,1 run of conduit & chases shall be measured and paid as one metre length of unit
M&L for PCC 1:2:4 type B1 using 20mm stone aggregate as as in foundations, filling and mass concrete complete all as specified and directed
M&L for 40 to 50mm thick stone patti rough dressed jodhpur stone slab cover laid in trenches for protection of cable 25 to 30 cm wide and not less than 80cm in length laid dry abutting each other with gap between adjacent slab not exceeding 10mm over sand cushioning complete all as specified and directed
M&L for sand cushioning with layer of dry sand (Local Tibba Sand) 80 mm thick before laying of cable and 150 mm thick after laying of cable in trenches complete all as specified and as directed by Engr-in-Charge. Note : Punned thickness of 180mm shall be considered for measurement and payment.
Supply, laying and testing cable XLPE Insulated,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sqmm 4 core complete all as specified and directed.
Flame Proof Lighting
Point wiring with 1.5 Sqmm copper conductor cables (multistranded) FRLSH PVC insulated and unsheathed in and including recessed stove enamelled steel conduit (ISI marked) 25mm dia with sunk cast iron/pressed steel terminal box of adequate size for one light point controlled by one, one way flame proof switch including continuous 1.5 Sqmm copper conductor (multistranded) FRLSH PVC insulated and unsheathed cable connected to earth dully complete all as specified conforming to IS-694 including fixing of conduit with clamps and screws at a interval not more than 1 mtr and making the disturbed surface to match with the existing surface and colour complete all as specified and directed.
S&F Switch flame proof rotary type with termination box in LM6, 6A, single pole 250V complete all as specified and directed.
Supply and Fixing of Flameproof cum Waterproof LED Bulk Head light fitting of 120W, IP66 protection of Cast Aluminum alloy material and Heat and Impact resistance toughen 'A' clear glass having Anti corrosive epoxy powder coated finish complete with all accessories pre wired and including connecting up with three core flexible copper conductor cable with suitable size. complete all as specified and directed
M & L for Wiring for circuit/submain wiring alongwith earth wire of the sizes 2 x 2.5 Sqmm + 1 x 2.5 Sqmm of FRLSH PVC insulated copper conductor, single core cable drawn through and including stove enamelled steel conduit surface/ recessed as required complete all as specified and directed. Note : All runs of cables and 1 run of conduit shall be measured and paid as one metre length of unit
Supply and fixing of DB SPN 4 way, double door, 240V complete all as specified and directed.
Earth work
Excavating in trenches n exc 1.5m wide and n exc 1.5 m in depth for foundation etc for shafts, wells, cesspits,manholes, pier holes,laying cables etc. nexc 10 sq m on plan and n exc1.5 m in depth and getting out in any type of soil complete all as specified and directed
Returning filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soil complete all as specified and directed
Removing of excavated soils to a lead not exc 50 M and depositing where directed at a level not exc1.5 M above the starting point complete all as specified and directed
Schedule of Credit Rs 8,11,360/-
M.D. CONSTRUCTION CO.
SHISHODIA ENTERPRISES
M K ENGINEERS CO.
BABU LAL PARIHAR
Rajan Traders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .