Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical 301 A WINGH AZIZ APARTMENT WAZI MOHALLA OLD PANVEL NAVI MUMBAI 410 206 | NAVI MUMBAI | RAIGAD | MAHARASHTRA | 410206 | Accepted-Technical Approved |
| 2 | Accepted-Technical HARSH INFRASTRUCTURE NEAR DWARKADISH PETROLEUM NANDANA DEVBHOOMI DWARKA JAMNAGAR GUJARAT 361315 | DEVBHUMI DWARKA | GUJARAT | 361315 | Accepted-Technical Approved |
| 3 | Rejected-Technical 2 YOUR TENDER SUBMITTED ON 22 08 2025 ON E TENDER WEBSITE 3 YOUR PRICE BID OPENED ON 11 09 2025 ON E TENDER WEBSITE SIR THIS IS TO NOTIFY YOU THAT YOUR TENDER FOR THE WORK UNDER REFERENCE HAS BEEN ACCEPTED | Rejected-Technical Not Appoved as original copy of bank solvency and working capital not submitted. |
| 4 | Rejected-Technical 8 51 PLOT NO 6 LIC COLONY SUJATA NAGAR PENDURTHY MANDAL VISAKHAPATNAM 530042 AP | 530042 | Rejected-Technical Not Appoved as original copy of MOU not submitted. |
| 5 | Rejected-Technical 33 NATIONAL CHAMBERS NEAR CITY GOLD CINEMA ASHRAM ROAD AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | Rejected-Technical Not Appoved as original copy of MOU not submitted. |
Tender Value
₹43.6 L
EMD Value
₹87,300
Closing Date
8 Oct 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE CARNICOBAR
HQ CWE Carnicobar c/o 99 APO Pin 744301
Provision of Solar Rooftop panels at Admin Block, CGDHQ-10, at Campbell Bay
2026_MES_788292_1
81012/E8
Open Tender
Civil Works
Works
180 days
Campbell Bay
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE Campbell Bay
₹87,300
Yes
17 Nov 2026
8 Sept 2026
10 Oct 2026
8 Sept 2026
8 Oct 2026
23 Sept 2026
60 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, delivery, installation of Solar Mono Crystalline Bifacial PV: >= 605Wp IEC 61215 : 2016, IEC 61730 : 2016, IEC 61701, IEC 62716, IEC 60068-2- 68, IEC 62804 including supply of all necessary accessories, etc complete in all Respect as per specification laid down else where in the tender and as per direction and satisfaction of Engineer In - Charge. | 46 | Each | - | - |
| 2 | Supplying, fiting & fixing of 25 KVa ( 10 + 10+ 5) Semi Hybrid connected String Inverter for Solar use along with all accessories.
Max. input voltage:180-440 V No. of MPPTs: 6 (2 per Inverter)
Max. number of PV strings per MPPT: 1, AC voltage range: 127V/220V
Nominal grid frequency: 50 Hz / 60 Hz
Power factor: > 0.99 @default value at nominal power, (adj. 0.8 leading - 0.8
lagging)
Over Voltage Category: OVC II(DC),OVC III(AC) | 1 | Each | - | - |
| 3 | Supplying, fiting & fixing of 12 volt 200 AH battery for Solar use (As per Inverter Capacity) along with all accessories. | 24 | Each | - | - |
| 4 | Supplying, fiting & fixing of conventional type Lightening Arrestors along with all accessories. | 1 | Each | - | - |
| 5 | Supplying, fitting & fixing of PV Module Mounting Hot Dip Galvanized Module Mounting Structures with 80 micron Galvanization Thickness GI Structure (Sheet Metal) consisting of mainly Angle material and accessories, capable of withstanding 180 km / hr. wind speed, Design Factor for safety 1.5 as recommended by PV manufacturer & as directed by Engineer In - Charge. | 1 | Each | - | - |
| 6 | Supplying, fitting & fixing of Array Junction Boxes, DC Junction Box with Glass fuse and DC SPD, complete in all respect as per specification laid down else where in the tender and as per direction and satisfaction of Engineer In - Charge. | 1 | Each Set | - | - |
| 7 | Supplying, fitting & fixing of Inverter / ACDB canopy/kisok with stand & fitting accessories complete in all Respect as per specification laid down and as per direction and satisfaction of Engineer In - Charge. | 1 | Each | - | - |
| 8 | Supplying & Installation of IIP/MCCB box with suitable rating, MCCB indicators, required for development of existing feeder as per site requirement complete in all Respect as per specification laid down and as per direction and satisfaction of Engineer In - Charge. | 1 | Each | - | - |
| 9 | Supplying, fitting - fixing of ACDB/GIP as per specification & approved SLD ,IP 65 suitable for outdoor installation complete in all Respect as per specification laid down else where in the tender and as per direction and satisfaction of Engineer In - Charge. | 1 | Each | - | - |
| 10 | Suppling & Installation of LT Solar Energy Generation meter complete in all Respect as per specification laid down else where in the tender and as per direction and satisfaction of Engineer In - Charge. | 1 | Each | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.85 MB
Tender.pdf
Tender Documents • 1.34 MB
BOQ_883587.xls
BOQ • 0.68 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .