Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹17.0 LAccepted-AOC | 1 | Accepted-AOC RABK 1 | |
| 2 | 2₹18.2 L+₹1.2 L (6.82%)Rejected-Finance | 2 | Rejected-Finance REJECT |
Tender Value
₹15.2 L
EMD Value
₹30,304
Closing Date
30 Jan 2024, 9:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EXECUTIVE ENGINEER
EXECUTIVE ENGINEER LUDHIANA CANAL AND GROUND WATER DIVISION WRD PB LDH DUGRI P 1 LDH
.Estimate for reconstruction of fall-cum-Bridge at RD 12000 of Kishanpura Disty.
2024_WR_115157_5
39/28A
Open Tender
Civil Works
Item Wise
45 days
MOGA
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,000
₹30,304
Yes
EXECUTIVE ENGINEER LUDHIANA CANAL AND GROUND WATER
2 Mar 2024
6 Jan 2024
30 Jan 2024
6 Jan 2024
30 Jan 2024
6 Jan 2024
12 Jan 2024
Amount
Dismantling brick work tile, masonry or tile lining In cement. (CSR - 8.5.B)
Dismantling concrete Reinforced cement concrete. (CSR - 8.6.e)
Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with excavated surplus soil. In Ordinary soil. Mechanical Means Depth upto 3 m. (CSR - 21.1.B.a)
Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications. PCC Grade M15. (CSR - 21.7.A)
Plain/Reinforced cement concrete in sub-structure complete as per drawing and Technical Specifications. RCC Grade M25. Height upto 5m With Batching Plant, Transit Mixer and Concrete Pump. (CSR - 21.32.F.a.ii)
Plain/Reinforced cement concrete in sub-structure complete as per drawing and Technical Specifications. RCC Grade M-30. Height upto 5m. Using Batching Plant, Transit Mixer and Concrete Pump. (CSR - 21.32.G.a.ii)
Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and Technical Specifications. (CSR - 21.33)
Cement concrete lining 75mm. thick or less laid manually for irrigation channels, using cement concrete M-15 with cement content 325 kg/cum mixed in an automatic computerized Batching & Mixing Plant and transported to the site in transit mixers with an average lead of 1 Km(FOR TRAPEZOIDAL SECTION AND CUP SECTION OF ALL RADII).(CSR - 19.4)
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical Specification (B) Sandy material (CSR - 21.36.B)
Supplying & laying dry brick ballast. (CSR - 10.30)
Drainage Spouts complete as per drawing no. SD/205 and Technical specification with 0.6 meter long GI 100 mm dia drainage GI light grade pipe (For Bridges). (CSR - 22.8.B)
Provision of an Reinforced cement concrete crash barrier at the edges of the Bridge,road, approaches to bridge structures and medians, constructed with M-40 grade concrete , with HYSD reinforcement conforming to IRC:21 and dowel bars 25 mm dia, 450 mm long at expansion joints filled with pre-moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclosure to MOST circular No. RW/NH - 33022/1/94-DO III dated 24 June 1994 as per dimensions in the approved drawing and at locations directed by the Engineer, all as specified-with concrete mixture. (CSR - 22.12.A)
Cautionary sign board 900x900x900mm triangular as per IRC 67- 2012 with high intensity Microprismatic grade retro reflective Sheeting as per ASTM D 4956 09 and as per IRC 67 2012 fixed over 4mm thick aluminum Composite material (ACM) sheeting having aluminum skin thickness of 0.4 to 0.5 mm on both sided and fixing the same with suitable size aluminum alloy rivets @ 200 mm c/c to back support frame of 25x25x3mm angle iron supported on a square hollow steel section post 60x60x3.2mm conforming to IS 4923 without cost of definition plate firmly fixed to ground in foundation concrete M-25 of size 0.45x0.45x0.75m for vertical post complete as per clause 801 of MORT&H specifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting & a certified copy of test reports from an independent test laboratory conforming to clause 6.7 of IRC 67-2012. Using high intensity. Microprismatic grade retro reflective Sheeting Type IV as per ASTM D 4956 09 and as per IRC 67 2012. (CSR - 24.44.A.B)
Hazard Marker sign board 300x900mm rectangular as per IRC 67- 2012 with high intensity Microprismatic grade retro reflective Sheeting as per ASTM D 4956 09 and IRC 67 2012, fixed over 4mm thick Aluminium Composite Material (ACM) sheeting having skin thickness of 0.4 to 0.5 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame of 25x25x3mm angle iron supported on a square hollow steel section post 60x60x3.2mm conforming to IS 4923 firmly fixed to ground including foundation concrete M-25 of size 0.45x0.45x0.60m for vertical post complete as per clause 801 of MORT&H specifications. Using high intensityMicroprismatic grade retro reflective Sheeting Type IV as per ASTM D 4956 09 and as per IRC 67 2012. (CSR - 24.51.B)
Mandatory sign board 900mm circular as per IRC 67- 2012 with high intensity Microprismatic grade retro reflective Sheeting as per ASTM D 4956 – 09 and as per IRC 67 – 2012. Fixed over 4mm thick aluminium Composite material (ACM) sheeting having aluminium skin thickness of 0.4 to 0.5 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame of 25x25x3mm angle iron supported on a square hollow steel section post 60x60x3.2mm conforming to IS 4923 without cost of definition plate firmly fixed to ground in foundation concrete M-25 of size 0.45x0.45x0.60m for vertical post complete as per clause 801 of MORT&H specifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting & a certified copy of test reports from an independent test laboratory conforming to clause 6.7 of IRC 67-2012. Using high intensity Microprismatic grade retro reflective Sheeting Type IV as per ASTM D 4956 09 and as per IRC 67 2012. (CSR - 24.45.A.B)
Putting 1:3 (Cement:water) cement slurry with cement @ 2.25 kg per sqm on prepared bed and side slopes before laying concrete on bed and side slopes. (CSR - 19.12)
Filling Contraction/Construction joints with special impervious hot pour. (CSR - 19.16)
Dressing side slopes and preparation of sub grade for lining. (CSR - 19.2)
Cement concrete lining 75mm. thick or less laid manually for irrigation channels, using cement concrete M-15 with cement content 325 kg/cum mixed in an automatic computerized Batching & Mixing Plant and transported to the site in transit mixers with an average lead of 1 Km(FOR TRAPEZOIDAL SECTION AND CUP SECTION OF ALL RADII).(CSR - 19.4)
THE CHOTIYAN CO-OP L AND C SOCIETY LTD
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .