| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.7 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹51.0 L+₹5.4 L (11.8%)Rejected-Finance NH 31 GAIRKATA PO SAKOAJHORA DIST JALPAIGURI W B PIN 735212 | JALPAIGURI | WEST BENGAL | 735212 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹55.7 L+₹10.1 L (22.0%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹56.9 L+₹11.2 L (24.6%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹62.3 L+₹16.7 L (36.5%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹56 L
EMD Value
₹1.1 L
Closing Date
14 Mar 2020, 6:00 pmClosed
CWE BINNAGURI
HQ CWE BINNAGURI
SPECIAL REPAIRS TO CERTAIN RESIDENTIAL BUILDING CUM STORES AND SECURITY WALL WITH RCC COLUMN BEAMS WITH BRICK MASONRY PANELS BARBED WIRE FENCING WITH ANGLE IRON FRAME WORK AT COOCH BEHAR MIL STN UNDER GE SOUTH BINNAGURI
2020_MES_323678_1
8010/BIN(S)/52/2019-20
Open Tender
Civil Works
Item Rate
120 days
COOCH BIHAR MIL STN
AS PER TENDER DOCUMENT
8 documents required · 8 mandatory
₹1,000
GE SOUTH BINNAGURI
₹1.1 L
Yes
23 Apr 2020
11 Feb 2020
16 Mar 2020
11 Feb 2020
14 Mar 2020
2 Mar 2020
Amount
Schedule 'A'
Taking down existing old tar felt of any type and course form roof surface including adjoining Parapets and removing the material to distance exceeding 50 mtr but n/exc. 100 Mtr including Roughening old concrete surfaces with wire brushes and cleaning the surface with water to remove all losses dust ets. complete all as specified and directed.
Disconnection existing tanks (any description)setting a side (or lowering if required for Repairs, cleaning etc, & hoisting if required, reconnecting and refining in position after cleaning and Removing all sludge and dirt etc with help of scrapers, wire brush and applied casting soda and Bleaching powder and cleaning out all sludge from tanks and mouth of circulation pipers etc and tank of tanks capacity exc, 500Ltrs and not exc. 1000 Ltrs complete all as specified and as directed
M & L labour for cutting groves in brick walls 75 mm wide and 65mm deep and shaping horizontal to Face of groove with cement mortar (1:3) complete all as specified and directed.
Cutting out cracks V section (Shape ) in existing roof slab or terracing cleaning out and filling Solidly with cement & sand mortar(1:1) complete all as specified and as directed.
M & L for 25 mm thick PCC 1:2:4 type B1 (Using 20 mm graded granite stone aggregate) mixed with integral Water Proofing Compound wherever required as directed and laid on RCC slab as base layer for roof treatment including roughing the top surface of concrete by using broom sticks while the concrete is green but excluding cost of Water Proofing compound complete all as specified and directed.
M & L 15 mm thick screed bed in cermet's mortar (1:4) in order to maintain proper slope over existing Roof surfaces for laying of APP based polymeric membrane finished even and smooth without using Extra cement complete all as specified and as directed.
M&L for water proofing treatment to non accessible RCC roof slab, including parapet comprising with the following courses of treatment/specified from bottom to top:- (a) Applying bituminous primer @ 0.40 Ltr per Sqm over plastered surface of roof including parapets surfaces (b) Over the priming coat laying one layer of APP based polymeric membrane of approved manufacturer, 3 mm thick of weight not less than 3.5 Kg/sqm reinforced with non woven polyester fabric of weight not less than 150 gms per Sqm. Polymeric members shall be taken to a height of 60 cm (min) and then inserted inside the groove of parapet wall and shall be finished by a membrane flashing. (c) Applying one coat of aluminium paint on top of APP for heat resistance @ 100ml/Sqm as per manufacturer etc complete all as specified and directed. (Note :- (i) Laying APP based polymeric membrane shall be done by torch of method or as per manufacturers Instructions. (ii) A minimum over lap of 100mm and 75 mm should be made at the end and side respectively.
Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness, (Below or above ground level) complete all as specified and directed.
M &L for 75 mm thick PCC(1:3:6)type C-2 using 40mm graded stone aggregate as in path & Plinth protection finished even and fair complete all as specified and directed.
M & L for 15mm thick screed bed in CM (1:6) for laying floor finishes complete all as specified and directed.
M & L for chequered cement concrete tiles 300 x 300 x 22 to 25mm thick, set, jointed and pointed in Neat cement slurry (with grey cement and pigment ) as n path/pavings complete all as specified and directed.
M &L PCC(1:2:4)type B1using 40 mm thick aggregate as in flooring finished even and smooth using extra cement complete all as specified and directed.
S& F 38mm wide and 3 mm thick glass dividing strips and inserted in position to confirm to design Complete all as specified and as directed
Taking down cement plaster , terrazzo topping on wall of any description including racking out Joints hacking for key and scrubbing down with water etc complete all as specified and as directed.
M &L for 20mm thick rendering in cement mortar (1:4) in two layers (10mm thick each) with water Proofing compound in top layer as per manufacture’s instruction finished even and smooth without Using extra cement complete all as specified and as directed Note:- integral water proofing compound Shall be measured and paid separately complete all as specified and directed.
M & L for 15 mm thick rendering on other than fair faces of brick work in CM (1:6) finished even and smooth without using extra cement complete all s specified and as directed
10mm thick rendering on fair faces of concrete surfaces as in ceiling in (CM) 1:3) finished even and Smooth without using extra cement complete all as specified as directed
Demolition of cement concrete of any description (reinforced of unreinforced) and in any position not otherwise specifically provided for complete all as specified and as directed.
Dismantling of brick work built in cement mortar and separating cleaning and stacking serviceable bricks for re-use in the work and removing unserviceable bricks from site of works complete all as specified and as directed.
M & L for PCC (1:2:4) type B-2 (using 40mm graded stone aggregate) as in foundations, mass concrete complete all as specified and as directed.
M &L for brickwork with subclass ‘B’ bricks, (locally available best quality) straight or curved on Plan exc 6cm mean radius built in cement mortar (1:6) complete all as specified and as directed.
All as per item no 21.00 here-in-above but except bricks complete all as specified and directed. Note :- Old serviceable bricks shall be obtained from Sri item No 19 here-in-before)
M & L for 15mm thick rendering in cement mortar (1:4) on brick or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
S &F in repair grating doom 100mm dia of PTMT (minimum weight 25 gms) complete all as Specified and as directed .
Supply only integral water proofing compound (ISI marked) of approved make/brand complete all as specified And as directed.
M&L for M-25 Desogn Mix Concrete using 20mm aggregate as in chajja and the like complete all as specified and as directed.
Preparation of old surfaces of wall and applying two coats of cement based paint oil emulsion including priming plastered and other surfaces with alkali resistant priming paint on surfaces of walls complete all as specified and directed.
M & L for three coats of white wash on newly plastered surfaces of wall including preparations Complete all as specified and as directed.
Preparing old surfaces of walls by brooming down or by steel wire brushing and applying two coats of white wash complete all as specified and directed.
M & L for applying three coats of white wash on newly plastered surfaces of ceiling including Preparation completes all as specified and as directed.
Preparing old surfaces of ceilings by brooming down or by steel wire brushing and applying two coats of white wash complete all as specified and directed.
Dismantling floor, hearth or wall tilling including cement mortar bedding (but not backing) Removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M & L 15mm thick screed bed in CM (1:6) for laying floor finishes complete all as specified and directed.
M&L Coloured Non Skid ceramic tiles 7 to 8 mm thick (Square/ Rectangular) area of each tile exceeding 0.11 Sq. M but not exceeding 0.18 Sq. M, in floors etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match complete all as specified and directed.
M &L for 10mm thick backing coat in CM (1:4) for laying wall tiles complete all as specified and directed.
M&L Coloured Glazed ceramic tiles in vertical surface 350 x 250 x 7 mm/ 450 x 350 x 7 mm thick set and jointed in neat cement slurry and pointed in white or Coloured cement to match complete all as specified and directed.
Taking down chowkat or frames with shutters (without taking of shutters from the frame) exc1.5 Sqm and n.exc 4.00Sqm each including hold fasts and removing the same from site complete all as specified and directed. (unit rate shall be inclusive of demolition of cement concrete blocks for embedding hold fasts complete)
All as per item No 37.00 here-in-avove but n.exc 1.5 sqm each and removing from site complete all as specified and directed.
Taking down shutters of any description exceeding 1 Sq. M but not exceeding 2 Sq. M each and removing to or from store complete all as specified and directed.
Taking down shutters of any description not exceeding 1 Sq. M each complete all as specified and directed.
S & F Second class hard wood plain, solid, straight Chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed.
S & F in opening Factory made solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube manufactured as per SSR Part I specifications and drawing complete all as specified and directed.
S & F Factory made solid panel PVC door shutter 30 mm thick (style) manufactured as per SSR Part I specifications and drawing. consisting of frame made out of MS tubes for top & Bottom rails. MS frames shall be covered with heat moulded plain colour PVC "C" channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail. Paneling of plain colour PVC sheet to be fitted in the MS frame welded/ sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement manufactured as per SSR Part I specifications and drawings complete all as specified and directed.
S&F 150mm ling Aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed.
S & F 105 x 60 mm size Pressed steel frames (thickness of profile 1.25mm) for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., with one shop coat of red oxide primer complete all as specified and directed.
S & F 125 x 60 mm size Pressed steel frames (thickness of profile 1.25mm) for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and directed.
S&F 35mm thick 2nd class hardwood approved factory made gauzed and and Skelton shutters open Rebutted and prepared to receive gauze without sash bars edges of framing plain, chamfered or rounded, fitted With mitred beads for securing gauze and reacted with preservative treatment and fitted to chwakts complete all as specified and detected (wire gauze shall be measured & paid separately here-in-after complete all as specified and directed.
S & F35mm thick factory made shutters ( three panel)with lock rail and panel of 9mm BWP Commercial ply or 12mm veneered particle board with commercial veneering on both faces size of rail and style as per IS -1003(part-1),kill seasoned and chemically pressure treated complete all as specified and directed.
Taking down, easing, adjusting and refixing in the same opening shutters of any description exceeding 1 Sq. M but not exceeding 2 Sq. M each and refixing builders hardware as required including renewal of unserviceable screws etc. complete all as specified and directed.
M & L for PCC (1:3:6)Type C-1(suing 20mm graded stone aggregate) for filling back to press steel Door frame complete all as specified and as directed.
S & F 100mm butt Stainless steel hinges medium weight complete all as specified and directed.
S & F 200mm long Aluminium anodized, barrel tower bolts of extruded section complete all as specified and directed.
S & F 125mm Extruded aluminium anodized alloy handles complete all as specified and directed.
S & F 300mm, mild steel ordinary rat tail rod pattern springs including roller and roller plate Complete all as specified.
S & F 300mm aluminium alloy anodized sliding door bolt with hasp staple (bolt type ) and fixing clips Area exc 0.010 Sqm but n,exc 0.50 Sqm each complete all as specified and directed.
Preparing surfaces of wood and wood based materials, steel and iron work new or old, of any description and girth not otherwise described, and treated with tar or coal tar black paint complete all as specified and directed.
M & L for preparation of old painted surfaces of wood and wood based surfaces of any description Not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel painting on the Complete all as specified and as directed.
M & L for preparation new painted surfaces of wood and wood based surfaces of any description Not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel painting on the Complete all as specified and as directed.
Tanking up or down steel tubing and connections f 15mm bore pipe for refixing complete all as Specified and as directed.
All as per ser item No 59.00 here-in-above but bore of pipe 20mm complete all as specified and directed.
All as per ser item No 59.00 here-in-above but bore of pipe 25mm complete all as specified and directed.
Refixing old steel tubing and connections of 15 mm bore of pipe in new or old position (walls, ceiling, floors etc) with new fittings complete all as specified and as directed.
All as per ser items NO 62.00 here-in-above but bore of pipe 20mm complete all as specified and directed.
All as per ser items NO 62.00 here-in-above but bore of pipe 25mm complete all as specified and directed.
S & F 15mm bore tubes, medium grade galvanized, with all fitting and fixed complete to walls and Ceilings or laid in floors complete all as specified and as directed.
All as per ser item no 65.00 here-in-above but bore of pipe 20mm complete all as specified and directed.
All as per ser item no 65.00 here-in-above but bore of pipe 25mm complete all as specified and directed.
Dismantling water tanks exceeding 500 litres and not exceeding 1000 litres capacity and removing to store complete all as specified and directed.
S &F rotational moulded polyethylene water storage tanks, multilayer, (cylindrical vertical with closed top) Hoisted and fixed in position of capacity 1000 ltrs (ISI Marked) complete all as specified and directed.
S & F 25 mm dia Ball brass Valves, high pressure, with polythene float and fly nut complete, screwed for Iron pipe or brass ferrule complete all as specified and directed.
S & F 25 mm dia Gun Metal, globe or Gate Valve with Iron wheel head Screwed both ends for Iron Pipe and fixed complete all as specified and directed.
All as per item no 71.00 here-in-above but 20mm dia complete all as specified and directed.
S & F in repair white colour PVC valveless, symphonic action type ,10 ltr capacity high or low level Flushing cistern, with inlet, ball valve, float and handle including brackets complete all as specified and as directed
S & F in repairs Chromium plated shower rose 125 mm size with or without swivel joints including taking down the existing fitting, fixing to steel pipe or union complete all as specified and directed.
S & F in repairs 15 mm bore Fancy type Chromium plated bib taps, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule including taking down the existing fitting complete all as specified and directed.
S & F in repairs Fancy type chromium plated 15 mm bore Angle/ plain Stop valves, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions including taking down the existing fitting complete all as specified and directed.
Supply 15 mm bore Fancy type pillar taps, Cast Copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe and fixed complete all as specified and directed.
Supply 15 mm bore Fancy type pillar taps, Cast Copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe and fixed in repairs including taking down the existing fitting complete all as specified and directed.
S & F in repair vitreous china wash basin white flat back, size 550x400mm excluding taps, waste, Chain and plug and porcelain stopper but including brackets complete all as specified and as directed.
S &F in repair 15mm dia PVC connections with PTMT nuts of length 600 mm long complete all as specified and as directed
S & F in repair vitreous china squatting pan, Orissa pattern’ size 580x440mm white, with integrate foot Rests (excluding flushing cistern and flush pips ) including connection to trap, and flushing pipe anti syhonage pope 18306 etc, including making good disturbed surfaces of floor complete all as specified and as directed.
S & F in repairs Brass Chromium plated tubular towel rail, 20 mm dia., D Type, 60 cm long between flanges including taking down the existing towel rail complete all as specified and directed.
S & F in repairs Steel rolling shutters of 1.25 mm thickness laths without ball bearing as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer erected in position as indicated complete push & pull or manual type complete all as specified and directed.
S & F in repairs Stainless Steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with Stainless steel wire staples including taking down the existing mesh and fixing new mesh with old beading complete all as specified and directed.
M & L for second class hard wood plain fillets, square, rectangular or triangular in section, bull nosed, splayed, chamfered or rounded on one edge or face, sectional area exceeding 6 and not exceeding 13 Sq. cm., clean sawn, secured with nails or brads complete all as specified and directed.
Fair finished flat Form work to Chajjas, water troughs and similar items including edges complete all as specified and directed.
S & F 4 mm thick Sheet glass, ordinary quality and glazing with oil putty in squares not exceeding 0.5 Sq. M in each pane complete all as specified and directed.
Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete (fittings such as switches, ceiling roses, pendants, regulators, socket outlet, bulk head fittings, tube light fittings etc. to be measured separately), and segregating serviceable fittings and keep them in safe custody for re-use and removing unserviceable fittings from site and making good the disturbed surface complete all as specified and as directed.
Taking down carefully by unscrewing from board /out-let boxes, fittings and fixtures such as switchs, sockets, ceiling rose, lamp holders, brackets,ceilling fittings, bulk head fittings, tube light fittings, and regulators. etc for re- use at site or carrying to the store (To be measured only when found serviceable in all respect complete for re- use) complete all as specified and as directed
Taking down main switch, DB of any size including MCB,s and making good disturbed surfaces, complete all as specified and directed by Engineer-in-Charge
Taking down old unserviceable existing sub main wiring with copper/aluminium conductor cable upto and including 6 sqmm single core including earth wire from existing conduit or wooden battens including taking out unserviceable wooden gutties etc, matching with the existing surfaces, complete all as specified and directed by Engineer-in-Charge.
M&L complete for concealed wiring with cable of size 1.5sqmm single core copper multistrand conductor including continuous earth wire, using cable FRLS flexible insulated(unsheathed) 1100 volts grade conforming to is 694 1990 drawn in to and including concealed ‘U ‘pvc rigid conduit medium duty with all fittings and fixing accessories ISI certified IS 9537 part -3 and terminated in to pressed steel terminal boxes with 3.00mm thick plastic laminated/ebonite sheet top covers fixed with brass screws, cap and washers for mounting switches, socket regulator, brackets etc and including necessary cement work complete all as directed by the Engr in charge including cutting chases pinning in making good to facing and pointing in cement moter 1;3 to the ends or cutting chases for concealed conduit point wiring and making good disturbed surface complete. Cutting not exc 4cm depth and 4cm width for followings:- (Note : The rates for concealed type wiring shall deemed to include the cost of cutting chases in the wall by using elect cutter and making good the disturbed surfaces of wall by providing cement plaster and matching the surfaces by white wash/colour wash all as per existing finishes complete.) complete all as specified and directed. (a)one light point & Fan point controlled by one, one way switch
(b ) one 3 pin socket out let 5 amps independent complete all as specified and directed.
(c ) one 3 pin 5 amps socket point in same board with other switches complete all as specified and directed.
(d) one 3 pin socket out let 15 amps independent but with cable of size 4 sqmm in point wiring and 4 sqmm in continuous earth wire .Note :-for srl no 5(a) to(d), cable to be incorporated in point wiring/sub main wiring complete all as specified and directed.
M&L for two single core (sub main) PVC insulated cable with 4 sqmm nominal cross sectional area multistranded copper conductor conforming to IS 694 and one single core green PVC insulated 4 sqmm multistranded copper conductor conforming to IS 694 earth continuity cable drawn through non metallic, medium duty, rigid PVC conduit not less than 20 mm dia concealed in wall including all conduit and fixing accessories including cutting chases & making disturbed surfaces complete all as directed. Note :- (I) The cost for cutting, chases required shall deemed to be included in the quoted unit rate. (II) Two run of sub main wire, one run of earth wire and one run of PVC conduit shall be measured one RM
S & F in replacement Switch Piano Flush Type Single Pole One Way 5 Amps complete all as specified and directed.
Fixing only switch piano type obtained against item No 2 here in-before complete all as specified and directed.
S & F in replacement for switch socket combination piano flush type 2 in 1,2/3 pin 5 amps flush type universal complete all as specified and directed.
Fixing only switch socket combination 3 pin 5amp/15amp obtained against item No 2 here -in-before complete all as specified and directed.
S & F in replacement electronic fan regulator Deluxe step type suitable for 1200/1400mm sweep ceiling fan AC 240V, 120 Watt (White) complete all as specified and directed.
M&L complete for ceiling rose surface Bakelite 3 terminal complete all as specified and directed.
Fixing only ceiling rose obtained against item No 2 here –in-before complete all as specified and directed.
Supply and fix 4 feet LED tube light fitting 18 Watt complete with all accessories internally pre-wired and incl connecting upto ceiling rose with three core 0.5 sqmm copper cable complete all as specified and directed.
Supply and fix in replacement LED 10 Watt diecast bulk head luminary cost aluminium alloy housing gray poweder coated, heat resistant prismatic glass table including connecting with short length of PVC insulated, sheathed copper conductor wire of size not less than 0.5 sqmm from light point lamp fitting & testing complete all as specified and directed. .
S & F in replacement pvc/polycarbonate type Lamp Holder, insulated body, with back plate for battern fittings complete all as specified and directed.
M&L MCBs suitable for lighting load, 50 Hz, 10 kA C curve of under mentioned types and rating (To be housed in DBs) here in before including making all electrical connection with suitable size of copper lugs complete all as specified and directed. -. (a) MCB SPN 32-63 Amps 240V.
(b) MCB SP 6-32Amps 240V.
Supplying and fixing 1100 Volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathing in service connection suspended by insulating hangers not more than 1 meter apart including 4 mm suspension wire on twin core cable 10 Sqmm flat or circular complete all as specified and directed.
Supply and fix, SPN DB, IP 43 protection, double door, 240 volts, 8 way complete all as specified and directed.
S & F in replacement 25 watt LED building security light made up of pressure die-cast aluminium , housing with high power LED as lighting source and lens embedded PC cover having separate driver compartment with IP65 protection and impact resistance of IK07. and all accessories including brackets made out of GI tubing , light grade, 40mm bore 1200 mm long bent to shape at 120 degree, fixed on top corner/centre of building by providing MS clamp made up of flat iron 50 x 6 mm including bolts nuts and washers of suitable size complete all as specified and directed.
Taking down carefully by unscrewing from boards/out-let boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc. for re-use at site or carrying to the store (To be measured only when found serviceable in all respects complete for re-use) complete all as specified and as directed.
S&F in repair surface & wall mounted 20/22 watt 1200mm LED Tube light fittings complete with constant current electronic driver all accessories including provision of three core PVC cable of copper conductor of size 23/.0076 and making connection complete all as specified and directed.
S & F in replacement LED 10 watt die cast bulk head luminary cost aluminium alloy housing gray powder coated, heat resistant prismatic glass table complete all as specified and directed.
Demolition of brickwork built in cement mortar incl complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.
Excavating in trenches, n. exc 1.5 m wide and exc 1.5 m to 3 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and exc 1.5 m additional in depth and getting out in soft/loose soil complete all as specified and directed.
M&L for Plain Cement concrete (1:4:8) type D2 (Using 40 mm graded stone agg) in foundations, filling and mass concrete complete all as specified as directed by the Engr-in-charge.
M&L for M-25, design mix Concrete using 20 mm aggregate for Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L for M-25, design mix Concrete using 20 mm aggregate for Columns, pillars, piers, posts and struts complete all as specified and directed.
M&L for M-25, design mix Concrete using 20 mm aggregate in Beams, cantilevers, lintels over 1.5 M span complete all as specified and directed.
M&L for flat. Rough finished surface of concrete, Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed.
M&L for, Formwork to sides of rectangular pillars, posts, struts, piers, columns and stanchions flat Fair finished surface of concrete complete all as specified and directed.
M& L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bres summers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc for fair finished surfaces complete all as specified and directed.
M&L for TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for TMT bars 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
All as per item ser No. 127.00 here-in-above but as in stirrups, spacers and binder, 8mm dia TMT bar complete all as specified and directed.
S&F for hand rails, half round or other steel section or core for wooden hand-rail right portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165
Dismantling of Barbed wire fencing of any type and size complete all as specified and directed.
M&L Galvanized. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanized mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as specified and directed.
M&L for brickwork using subclass 'B' bricks' straight or curved on plan exc 6m mean radius, built in Cement mortar in 1:4 complete all as specified and directed.
M&L for rendering 15 mm thick cement plaster in cement mortar 1:6 on fair fair faces of brickwork or concrete surfaces complete all as specified and directed.
M&L for preparation of newly plastered surfaces of any description and applying two coats of cement base paints over a coat of alkali resistant primer complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick with soils complete all as specified and directed.
Removing Excavated soils exceeding 500 M but not exceeding 1 KM and depositing where directed complete all as specified and directed.
Preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red oxide zinc chrome primer complete all as specified and directed.
samrat saw mill and joinery workshop
M/s PATEL ENGINEERING
M/s Sohini Construction
S.N. GHOSH AND CO.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .