OFFICE OF THE XEN MH DIVISION GMCH JAMMU
Executive Engineer Mech and Hosp. Div Jammu Bakshi Nagar
Strengthening of air conditioning system at CDEHall, Lecture rooms and Library room of Indira Gandhi Govt Dental College, Jammu
2026_PWDJK_322856_1
MHDJ/e-NIT 173 of 2026-27
Open Tender
Machineries/ Mechanical Engg Items
Turn-key
30 days
IGGDC jammu
as per enit
2 documents required · 2 mandatory
₹1,000
Yes
XEN MH DIVISION GMCH JAMMU
₹45,000
18 Sept 2026
31 Aug 2026
19 Sept 2026
1 Sept 2026
18 Sept 2026
1 Sept 2026
1 Sept 2026 - 10 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | SITC of 2.0 TR split air conditioners (Hot and Cold) with all accessories (along with outdoor stand) and ambient upper temperature range of >= 54 degree Celsius for cooling with Maximum cooling capacity >= 6500 W and for heating ambient lower temperature range <= 0 degree Celsius with Maximum Heating Capacity >=6000 W having Air Flow Rate >=580 cfm to be installed in various locations of Administrative Block of IGGDC, Jammu with minimum 3 star and of reputed make along with allied accessories i.e. minimum of 10’ of refrigerant pipes and communication cable. Complete job as per site requirement and instructions of Engineer-in-charge and also includes cost of materials, labour charges, transportation charges and all other charges and taxes.
Make: O-General/Hitachi/Diakin/carrier/Bluestar. | - | nos. | 100 | - |
| 2 | SITC of 2.0 TR Split air conditioner to be installed at various section of Administrative Block of IGGDC, Jammu with all accessories (along with outdoor stand and drain pipe) having below given specifications:
Air Conditioning Technology: Inverter
Min. Star Rating: 3
Max. Cooling Capacity >= 23406 BTU/hr
Air Flow Volume(High) >= 699 CFM
Ambient upper temperature range >= 56 degree Celsius
Refrigerant: Ecofriendly
Complete job as per site requirement and instructions of Engineer-in-charge and also includes cost of materials, labour charges, transportation charges and all other charges.
Make: O-General/Bluestar/Hitachi/Diakin/carrier. | - | nos. | 100 | - |
| 3 | SITC of 1.5 TR Split Air Conditioner (Hot & Cold) complete with all accessories (including outdoor unit stand), suitable for operation at ambient temperature up to 52°C in cooling mode having minimum cooling capacity of 5200 W and suitable for operation at ambient temperature down to 0°C in heating mode having minimum heating capacity of 5200 W. The unit shall have minimum air flow rate of 570 CFM and minimum 3-Star BEE rating. The AC shall be of reputed make such as Daikin, O-General, Mitsubishi, Hitachi, Bluestar. The scope shall include supply and installation of minimum 10 feet refrigerant copper piping, communication cable between indoor and outdoor units, drain piping, insulation, outdoor stand and all other accessories required for satisfactory operation. The Job includes all materials, labour, transportation, testing, commissioning, taxes and all incidental charges complete as per site requirements and directions of the Engineer-in-Charge. | - | no. | 100 | - |
| 4 | Supply, Installation, Testing and Commissioning of 5KVA copper wound automatic wall mounted voltage stabilizer input Voltage 90-300 V & of superior quality ISI mark for ACs.
Make: Microtek/Aulten/Servokon/Electricfield | - | nos. | 100 | - |
| 5 | Providing and fitting of SPN of 32 Amp of standard make i.e. Havells, L&T/ABB with Gang box (complete with fittings) for ACs to be installed. | - | nos. | 100 | - |
| 6 | Providing and fitting of extra copper pipe with insulation. | - | ft | 100 | - |
| 7 | Providing and laying (using conduits and wire fasteners / cable clips) ) of 6 sq mm ISI Marked, FRLS PVC insulated copper conductor cable and of standard make i.e. Havells, Polycab, Finolex, Anchor only for the purpose of interconnecting stabilizers, digital timer panel and electrical panel . Complete job as per instructions of Engineer-in-charge and site requirements and also includes cost of materials (including clamps, bends/elbows, Tee-bends, thimbles etc.), labour charges, transportation charges and all other charges and taxes. | - | mtrs | 100 | - |
| 8 | Providing and Installation of Heavy Duty Main Electrical Panel (Powder Coated)-200A which includes MCCB 250A-4 Pole, 50 Ka breaking circuit capacity of standard make i.e. Havells, L&T of required size along with spread links and04 nos .buss bar of capacity 250A each along with holes for thimbling of the cable with nut bolt arrangement as per site requirement for Connection of incoming cable connecting using aluminiumarmoured cable of standard make. | - | job | 100 | - |
| 9 | Providing and Installation of MCCB 250A-4 Pole 50 Ka breaking circuit capacity with cover of standard make with i.e. Havells, L&Tuse for Connection of incoming connecting cables from the electric sub-station and also connect it to Servo stabilizer/DG Panel using aluminiumarmoured cable of standard make. | - | job | 100 | - |
| 10 | Providing and fitting of Double Door 8-Way TPN Distribution Board complete with 63A, 4 Pole MCCB incomer of 36 kA breaking capacity, suitable busbars, neutral link, earth bar and outgoing MCBs of required ratings, including all accessories, connections, testing and commissioning as required. The work shall be carried out complete in all respects as per the directions of the Engineer-in-Charge. | - | nos. | 100 | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.92 MB
BOQ_1084764.xls
BOQ • 0.29 MB
com.pdf
PDF • 0.16 MB
com.pdf
PDF • 0.16 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .