Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.5 LAccepted-AOC 36 THE MALL FEROZEPUR CANTT 152001 | FEROZEPUR CANTT | FEROZEPUR | PUNJAB | 152001 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹24.9 L+₹4.4 L (21.3%)Rejected-Finance H NO 37 VIKAS VIHAR PHASE II FEROZEPUR CITY PB 152002 | FEROZEPUR CITY | FEROZEPUR | PUNJAB | 152002 | L2 | Rejected-Finance Higher bidder | |
| 3 | L3₹24.9 L+₹4.4 L (21.4%)Rejected-Finance | L3 | Rejected-Finance Higher bidder | |
| 4 | L4₹24.9 L+₹4.4 L (21.5%)Rejected-Finance | L4 | Rejected-Finance Higher bidder | |
| 5 | L5₹24.9 L+₹4.4 L (21.5%)Rejected-Finance | L5 | Rejected-Finance Higher bidder |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
25 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Ferozepur Cantt
HQ CWE Ferozepur Cantt
CWE/FZR- /2021-22 Repair/maint of HT OH/UG distribution system and allied works for AOR of ARTY BDE and Inf Bde under GE (East) Ferozepur Cantt
2021_MES_490989_4
CWE/FZR-30/2021-22
Open Tender
Civil Works
Item Rate
180 days
Ferozepur Cantt
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (East) Ferozepur
₹50,000
Yes
23 Apr 2022
11 Mar 2022
4 Apr 2022
11 Mar 2022
25 Mar 2022
19 Mar 2022
60 days
Amount
Excavation in trenches in soft/loose soil not exceeding 1.5 meter wide and not exceeding 1.5 meter deep for laying of cable, pole foundation, etc including taking out old brick cable protection cover and getting out forming bottom surface to required gradient complete all as specified and directed.
All as per item No 1 hereinbefore but depth exceeding 1.5 meter but not exceeding 3.0 meter for poles etc.
Returning, filling in, earth including spreading, leveling watering and well ramming in layers each not exceeding 25cm thick each layer, complete all as specified and directed.
Removal of surplus soil to a distance not exc. 50 meter and depositing where directed at a level not exc. 1.5 meter above the starting point complete all as specified and directed.
M&L for Precast reinforced cement concrete cable cover factory made class HV, type-I, flat, size 300mm x 180mm x 40mm for HT cable ISI marked, laid flat across the cable, complete all as specified and directed.
M&L Dry and clean fine sand for cable cushioning to underground cable protection, complete all as specified. (Excavation and earth work measured separately). Note-Punned down thickness shall be measured.
M&L for Cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation of poles including necessary form work, fair finished to exposed surfaces without using extra cement wherever required complete all as specified and directed.
M&L for Cement concrete (1:3:6) type C-2 using 40mm graded stone aggregate as in foundation of stay assembly/feeder pillar/LT panel etc including necessary form work, fair finished surfaces without using extra cement complete all as specified.
M&L for Cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in foundation of electric poles/struts etc including necessary form work, fair finished surfaces without using extra cement complete all as specified.
Dismantling & taking out old damaged PCC/Steel pole of any size and removing from site of work complete all as specified and directed.
Dismantling & taking out old damaged stay assembly complete with stay wire, loop type insulator,worntout clamps etc of any size and removing from site of work complete all as specified and directed.
Dismantling and taking down old wornt out ACSR conductor of any type and size complete all as specified and directed.
Dismantling & taking down old wornt out MS clamps/cross arms/channels complete with nuts & bolts etc complete all as specified and directed.
Dismantling and taking down old U/S insulators of any type and size complete all as specified and directed.
Dismantling and taking down old air break gang operated switches vertical/horizontal mounted including insulators and operating mechanism for repair/ replacement of broken/worn out components and insulators etc of any type and size complete all as specified and directed.
Dismantling and taking down old U/S Earth Wire of any type and size complete all as specified and directed.
M&L for Pre-stressed concrete pole 11.0 meter long, 152 mm X 152mm at top and 152mm X 260mm at bottom, class-9, complying with the requirement of IS-1678-1978 including painting of poles with two coats of synthetic enamel paint over a coat of cement primer with red and yellow strips of 30cm each up to 1.5 meter from top of PCC base and numbering of pole and two coats of white wash on PCC base, as in repairs complete all as specified . (PCC and earth work shall be measured separately).
M&L for Stay assembly complete comprising of mild steel plate 300mmx300mmx 6mm thick, mild steel galvanized stay bow 40 cm long with two nos galvanized thimbles 20mm dia of MS galvanized stay rod 180 cm long complete with & including accessories as shown in electrical plate No 1 of SSR Part-I all as specified as in repairs.(loop type insulator, stay clamps, stay wire, excavation and concrete measured separately).
M&L for Pin type, porcelain, vitreous, white, brown or green insulator of height 150 mm x 150 mm dia of 11000 Volts grade including one galvanized mild steel spindle, nut & two washers, complete all as specified.
M&L for Disc type, porcelain, vitreous, white, brown or green insulator of height 145 mm x 255 mm dia for working pressure 11000 Volts ball and socket type of two in series disc assembly with tension clamp complete all as specified.
M&L for Loop type insulator, porcelain, vitreous white, brown or green of size 90mm x140mm and clearance of hole 25.5 mm for stay assembly, complete all as specified.
M&L for providing GI Earth continuity/Gurad Wire 8 SWG wire on HT pole fixed with MS clamp, bolts, nuts of approved size complete all as specified & directed by engineer in charge.
M&L for Cross arms, bracings, stiffeners, supporting clamps and back plates, fabricated from structural steel sections, drilling holes for bolts, in any shape or size as indicated or directed and including necessary welding, bending cold or hot inclusive of nuts, bolts, washers and two coats of aluminum paint over a coat of aluminum primer including preparation of surfaces, complete all as specified.
M&L for Anti climbing device spike type fabricated out of MS flat 50mm x 6 mm in two parts with 14 Nos 230 mm long and 12mm dia spikes, sharpened ends with and including nuts, bolts & washers and welding made to shape to suit the cross section of poles including painting with two coats of aluminum paint over a coat of red oxide primer complete all as specified.
M&L in repair for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size, complete all as specified.
M&L for Galvanized iron stay strand of size 7/4mm complete all as specified.
M&L as in repair / replacement Lightening arrestor expulsion type for outdoor suitable for 11 KV high tension line complete with all fittings with discharge capacity 65 Kilo amperes, including bracket clamps, nuts, bolts & washers and connection to earth wire & SWG GI wire of 4mm size complete all as specified.
M&L for Aluminum conductor steel reinforced (ACSR) of any size complete including jointing for over head line on poles, including GI wire 14 SWG jumper line taps complete all as specified and as directed by engineer in charge, all as required following sizes of conductor:-(a) 6/1x3 mm Ferret.(b) 6/1x3.66 mm Mink.(c ) 6/1x2.59 mm weasel. complete all as specified. NOTE-Measurement for the purpose of payment shall be made by measuring horizontal distance centre to centre distance between each two adjacent poles by additional 3% extra for sag, joints & jumpers etc.
M&L for Air break gang operated switch, triple pole, mechanically operated, with contacts of ferrous knife and spring loaded moving contact of copper, vertically mounted, (12 insulator type) mounted on insulator and steel frame with operating mechanism in accordance with IS-9921 including 25mm bore medium grade GI pipe to worked from ground level for current rating up to 200 Amps 11 KV with locking mechanism, mild steel clamp, nuts, bolts, washers, operating handle with in both OFF and ON position of required size including two coats of aluminum paint over a coat of red oxide complete all as specified.
S&F in repair/replacement Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminum conductor cable of size 95 sqmm,complete all as specified and directed.
All as per item No 30 above but 120 sqmm to 185 sqmm
S&F in repairs/ Replacement Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminum conductor cable of size 95 sqmm,complete all as specified and directed.
All as per item No 32 above but 120 sqmm to 185 sqmm
S&F in repairs XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured electric cable (heavy duty),HT 11000 Volts grade (E) with aluminum conductor 3 core 95 sqmm ISI marked IS: 7098-1985, laid in trenches, duct, through pipe, in floor, on pole including jointing and testing including taking out old unerviceable complete all as specified. Note: Clamps, GI pipe, excavation & earth work, sand cushion, and brick protection shall be measured and paid separately.
All as per item No 34 above but of size 120 Sqmm.
All as per item No 34 above but of size 150 Sqmm.
All as per item No 34 above but of size 185 Sqmm.
M&L in repairs / replacement Stranded aluminum conductor PVC HT jumpers with colour coding of 95 Sqmm size and of Length not less then 2mtr with aluminum thimble duly crimpled with crimping tools complete all as specified.
S&F HT Cable route indicator duly marked with HT cable Size and Feeder Name, of mild steel or cast iron plate of size 10 cm dia 5 cm thick welded on GI pipe light grade of size 40 mm and length 1.5 m with MS sheet of size 50x50x20mm Welded at bottom and GI pipe should be 90 cm in ground & 60 cm height above ground level duly embended in PCC (1:2:4) type B-1, in ground with mild steel flat/angle/rod complete all as specified
M&L for Mild steel galvanized pipe, light grade, 100 mm nominal bore for passing of cable, fixed to poles/laid under floor/road crossing/walls complete with and including clamps socket & elbow etc complete all as specified.
All as per item No 40 hereinbefore but of size 80 mm bore.
Painting to HT steel tubular pole with and including cross arms 11 mtr long except planting depth /PCC coping including two coats of aluminum paint with scrabing of old paint including preparation of old painted surface Numbering of poles by making a circle of black colour and inside circle writing of (HT POLE/FEEDER NAME/POLE NO. ) in white colour and Painting with red and yellow strips of 30cm each up to 1.5 meter from top of PCC base all as specified and directed . complete all as specified and directed .
Painting of HT PCC pole/steel tubular pole upto 1.5 mtr height from PCC, of synthetic enamel paint over a coat of cement primer with red and Yellow strips & Numbering of poles by making a circle of black colour and inside circle writing of (HT POLE/ FEEDER NAME/POLE NO. ) in white colour all as specified and directed by Engr-in-Charge.
M&L for Boring of holes under road, pavement, hard standing for laying pipe for crossing cable including getting out, disposal of rubbish off to a distance upto 50 Mtrs including 100 mm GI pipe medium grade
M&L for Earthing complete for GOD/LA/Panel, all as shown on electrical plate No 3 of MES schedule part-I , as in repairs and as specified including the following :-(I) Galvanized steel earth plate of size 60cmsx60cmsx6mm thick buried directly in ground vertically to a depth not less than 2.25 meter below ground level with top edge of earth plate at a depth not less than 1.50 meter below normal ground level.(ii) Earth plate surrounded by and packed with char-coal and common salt in alternative layers (n.exc 15cms each layer).(iii) 32mmx6mm G.I earth strip from earth plate to main switch board including necessary GI bolts, nuts check nuts, washers, thimbles etc.(iv) 50mm bore, light grade, GI pipe for protection to earth-strip.(v) 20mm bore, light grade, GI pipe for watering including GI funnel and wire mesh. Pipe shall be provided vertically up to top level of earth pit and then taken horizontally to the earth pit. (vi) 50mm thick pre-cast cover of cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate and MS angle iron 25x25x3mm frame including two coats of painting over a coat of red oxide to exposed steel surfaces.(vii) Excavation in soft/loose soil, returning filling & removal of surplus soil to a distance up to 50 meter as directed.
M&L for pinpointing of 11 KV underground HT cable fault of any size with help of cable fault locating machine (CFL Machine) consisting of DC Testing,Thumping system and DIGI point Sensor complete to locate the exact fault location (1'st fault) all as specified. Note : Contractor should prepared the layout plan with proper dimensions of HT route as per site / Fault location and submiited the same to the AGE E/M Office.
All as per item No 46 here in before but sucessive fault at other location/Feeder
M &L for cable jointing kit for 11 KV (Earthed) grade cable for Heat-shrinkabIe straight through heat-shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminum conductor cable of size 95 sqmm,complete all as specified and directed. Note:- Meggering of cable after disconnecting form GOD/panel as directed, including cutting of cable and preparation for jointing of defective portion of cable.
All as per item No 48 above but 120 sqmm to 185 sqmm complete all as specified and directed. Note for item No 48 & 49 (i) After Rectification of the fault, the cable route indicator should be fixed near joint location. (ii) Cable route indicator should be paid separately in respective item.
M&L for repair to 11 KV, 200Amps/ 400 Amps GOD/ AB Switches consisting of alignment,applying petrolium jelly to moving /fixed contact (Male/Female contact assy ),replacement of moving/fixed contact,copper strip jumper etc for smooth operation of GOD switches,tightening of channels /clamps for level setting,tightening of in/out jumper, jointing with thimbles etc all as specified and directed by Engr -in -Charge
Re-Stretching only of loosened existing ACSR conductor with GI wires and cradles (Per Span consisting of any number and size of wire) any size, by opening the binding wire from insulator and re-fixining after streching with proper sag incl strenghtening of ACSR conductor and re-binding the same on insulators and binding complete all as directed. NOTE :- The unit rate includes attending the complaints of snapping of conductors as and when occured and as intimated
M&L for Pruning of tree branches of any size /dia from HT overhead line up to a minimum clearance of 2.5 mtr from over head conductor incl T &P and transportation for disposal complete all as specified and directed by Engr in Charge.
M&L for Painting of two coats of aluminum paint including preparation of surfaces by scraping of Cross arms, bracings, stiffeners, supporting clamps and back plates, fabricated from structural steel sections, in any shape or size on Two pole Structure at Sub-station as indicated or directed complete all as specified.
M&L for Painting of two coats of aluminum paint including preparation of surfaces by scraping of Cross arms, bracings, stiffeners, supporting clamps and back plates, fabricated from structural steel sections, in any shape or size on Four pole Structure at Sub-station as indicated or directed complete all as specified.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering and removing surplus soil to a distance n.exc 50m and making good surface in hard dense soil complete all as specified.
S&F rolled mild steel angle for Post and struts in fencing including cutting top to shape as directed, drilling holes, notching for wire etc, flat iron fillets (For securing wiremesh) including all necessary drilling, boulting, or reveting etc and similar work confirming to FE-290 Gde E165 ,compete all as specified.
M&L Cement concrete (1:3:6) type C-1 (20 mm graded stone aggregate) as in post hole including necessary formwork complete all as specified.
S&F Mild steel round bars 10 mm dia and over to support chain link fencing, cut to length bent to shape required including cranking, and binding, FE-500/550 confirming to IS-1786-1985, complete all as specified.
Supply only Chain link MS galvanisd fencing of any size and type, complete all as specified.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire, complete all as specified.
M&L Preparation of new steel surfaces of any description, over 10cm width or girth and applying two coats of aluminium paint over a coat of aluminium red oxide, complete all as specified.
Supply and spreading 40 mm graded stone coarse aggrgate in substation yard complete all as specified and directed.
Supply, fix in replacement of Aluminium strip 25 x 3.15mm with clamp , fixing screws, UPVC Insulators etc. for roof conductors/ fixing on HT two/four pole structure above ground complete all as specified and directed.
Supply, fix in replacement of Galvanised iron strip 32 x 6mm buried in ground complete all as specified and directed.
Karan Engineers
M/s Sham and Company
S.R. Kaura and Company
Tarsem Chand Singla Electrical Contractor
HAPPY ELECTRICALS
M/S Pee Kay Builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .