| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC | ₹1.3 Cr | L1 | Accepted-AOC Being lowest |
| 2 | L2₹1.4 Cr+₹13.4 L (10.4%)Rejected-Finance FLAT NO B 401 4TH FLOOR NAVADURGA CO OP HSG SOCIETY LTD PLOT NO 7 SECTOR 19A NERUR EAST NAVI MUMBAI THANE MAHARASHTRA 400 706 | NAVI MUMBAI | THANE | MAHARASHTRA | 400706 | ₹1.4 Cr+₹13.4 L (10.4%) | L2 | Rejected-Finance Other than being lowest |
| 3 | L3₹1.5 Cr+₹19.2 L (14.9%)Rejected-Finance FLAT NO 002 MAHAVIR VILLA CHS LTD PLOT NO 259 SECTOR 21 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | ₹1.5 Cr+₹19.2 L (14.9%) | L3 | Rejected-Finance Other than being lowest |
| 4 | L4₹1.5 Cr+₹20.9 L (16.3%)Rejected-Finance 15 281 CHHILI INT ROAD GHATIYA AZAM KHAN AGRA UTTAR PRADESH 282003 | AGRA | UTTAR PRADESH | 282003 | ₹1.5 Cr+₹20.9 L (16.3%) | L4 | Rejected-Finance Other than being lowest |
| 5 | L5₹1.5 Cr+₹22.0 L (17.1%)Rejected-Finance | ₹1.5 Cr+₹22.0 L (17.1%) | L5 | Rejected-Finance Other than being lowest |
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
30 Sept 2024, 6:00 pmClosed
CWE (NW) Mumbai
Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 05
ADDITION/ALTERATION AND SPECIAL REPAIR TO BUILDING NO P 173 AT MWC UNDER GE (NW) KUNJALI, COLABA, MUMBAI
2024_MES_670635_1
8381/CWE(NW)MUMBAI/E8
Open Tender
Civil Works
Item Rate
270 days
GE (NW) Kunjali
Class B
Category a (i)
7 documents required · 7 mandatory
₹1,000
GE (NW) Kunjali
₹2.2 L
Yes
21 Nov 2024
3 Sept 2024
2 Oct 2024
3 Sept 2024
30 Sept 2024
24 Sept 2024
3 Sept 2024 - 23 Sept 2024
Amount
SCHEDULE 'A' PART I (B/R WORKS) Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness including cover fillets complete all as specified.
Dismantling of fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section complete all as specified.
Supply & Fixing second clas Hard wood (Sal) Plain fillets exc 6 sqcm and not exc 13 sqcm square, rectangular or triangular in section, clean sawn, secured with nails complete all as specified .
Taking down cement plaster of any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc and removing debris outside MD land. Note: The place of disposal shall be find out by the contractor.
Material & Labour for rendering 15 mm thick on fair faces of brick work or concrete surfaces of wall in CM 1:4 mixed with waterproofing compound @ 3% of weight of cement and finished even and smooth without using extra cement complete all as specified and directed. Note- Water proofing compound shall be measured and paid seperately.
Material & Labour for rendering 5 mm thick on fair faces of concrete surfaces of ceiling in CM 1:3 mixed with waterproofing compound @ 3% of weight of cement and finished even and smooth without using extra cement complete all as specified and directed. Note- Water proofing compound shall be measured and paid seperately.
Supply only Integral waterproofing compound
Material & Labour for preparing new plastered surfaces of wall, applying one coat of wall care putty not less than 2mm thickness and making the surface even and smooth using emery paper and applying two coats of oil bound distemper over a coat of alkali resistant primer complete all as specified.
Material & Labour for preparation of new plastered ceiling surfaces, applying one coat of wall care putty not less than 2mm thickness and making the surface even and smooth using emery paper and applying two coats of acrylic based paint (100% acrylic) complete all as specified as directed by EIC .
Material & Labour for providing and injecting chemical edmulsion for post construction anti termite treatment of voids in masonery using chemical emulsion at the rate of one litre per hole, 300 mm interval including drilling hole at 45 degree and replugging them in CM 1:2 (1 Cement : 2 Coarse Sand) to match the existing wall complete all as specified & directed by Engr-in-Charge.
Supply & Fixing for Amstrong optra acoustical Wall panelling with square edge made of fiber glass substrate 25 mm thick and wrapped on lthe front side with an acousticaltransparent and fire resistant fabric with an option of colour as approved of size 2100 x 600 or 600 x 600mm providing a minimum sound absorption level of 0.90 NRC to be affixed to wall using wall panel impalers. Panel to be fixed using self tapping screw. Silica based construction adhesive to be dabbed on the projecting elements (spikes) of the impalers all as per manufacturers instructions and directed by Engineer- in- charge .
Supply & Fixing for Amstrong ceiling made out of 600 x 600x 15 mm thick optra 101(white) acoustics ceiling board/tiles deep panel suspender system made out of Aluminium powder coated main tee of size 24mm x 43mm x 0.63mm and cross tees of size 30mmx24mmx0.63mm and angle size 19mm x 19mm x 0.63mm powder coated including 2.68 mm GI wire for suspending, necessary bolts, nut,clits, pin hook, washer,etc for securing frame work to ceiling to snap grid all as per manufacturers instructions and directed by Engineer- in- charge .
Supply & Fixing 25mm thick Wood wool building slabs , light weight, type 1, fixed with nails to timber frame work in wall complete all as specified and directed by Engineer- in- charge .
Supply & Fixing in repairs 4mm thick PVC tiles/ sheets, laminated, plain coloured, marbled mosaic or mottled finish, homogeneous laid with approved rubber based adhesive in floors complete all as specified and directed by Engineer- in- charge .
Material & Labour for preparing surfaces of timber piles and diping in a hot mixture of tar and creosote in the proportion of 20 kg coal tar pitch to 25 litres of creosote oil, for 4 mins complete all as specified and directed by Engineer- in- charge .
Dismantling boarding, any description, fixed in any position with nails.
Supply & Fixing of vista branded wooden laminated flooring size 1215x195x8.3 alongwith floring profiles, reducer, skirting, molding with matching color over 2mm thick hitlon foam all as specified as directed by EIC .
Material & Labour for 18 mm thick Plywood, grade BWP, type BB fixed with screws to timber frame work complete all as specified and directed by Engr-in-charge.
Material & Labour for Prelaminated sunmica 1 mm thick exterior grade, with decorative choice lamination & fixed with adhesive (as per manufacture instructions) to timber frame work. all as specified and directed by Engr-in-Charge.
Supply & Fixing collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc made out of sections as specified in clause No 10.24 of SSR Part I erected in position and securing runners with hold fasts and brackets complete all as specified and directed.
M&L for rendering 20 mm thick pre polymer modified ready mixed cement based plaster in two coats 12 mm thick base coat and 8 mm thick finishing/final coat using polymer modified ready mixed cement based plaster having minimum composition of cement & sand (1:4) using fully treated dry, well graded natural sand conforming to IS-383 suitable for external plastering having low rebound properties, low water demand for curing properties, mechnical mixing with water in a matalic tray only to made good, consistency as per the specification of the manufacturer and applied over exterior masonry and concrete surfaces including using richer mix for making corners if necessary including making grooves of existing size and necessary two legged MS pipe scaffolding wherever required including curing,upto ground plus 4th floor bldg complete all as specified and directed.
Demolition of Cement concrete (unreinforced) of Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work and removal of debris out of MD land complete all as specified. Note: The place of disposal shall be find out by the contractor.
Demolition of Brick tiles or terracing tiles, single layer on roofs and removal of debris out of MD land complete all as specified. Note: The place of disposal shall be find out by the contractor.
Material & Labour for 25mm thick PCC 1:2:4 type B0 using 12.50mm graded stone aggregate as a leveling course / padding on RCC roof top surfaces laid to slope and finished fair and even complete all as specified.
Material & Labour for rendering 10mm thick on fair faces of concrete on roof top in cement mortar 1:3 mixed with water proofing compound and finished even and smooth by using steel trovel complete all as specified. Note - WPC will be measured and paid saprately.
Material & Labour for preparing roof surface and applying water proofing treatment as per manufacturers instructions and comprises of the following activities:- (a) Apply a coat of oil based bituminous primer @ 200 gms/ sqm on the prepared surfaces. (b) Apply a coat of blown type bitumen grade 85/25 conforming to IS:702 heated to a working temperature of 180 degree C and applied @ 1.2 Kg/Sqm of the surface area. (c) Provide and lay 4mm thick APP modified membrane using torch application method weighing not less than 4.00 Kg per square meter reinforced with non woven polyester matt, weighing not less than 160gm/sqm having softening point not less than 140 degree C , Longitudinal tensile strengh not less than 650 N/5 CM, tear strength of 180N(Min), a static puncture resistance of 180, keeping a minimum of 10 cm over laps and 15cm end lap. (d) Finishing surface with solar reflective bituminous aluminium paint, @ 100 gm/Sqm complete The APP membrane shall be taken upto minimum 200 mm on vertical surfaces. The edge of the membrane shall be sealed with sealant. The rain water gutter portion shall be finished with cement mortar 1:4 to provide requisite slope towards rain water pipe outlet. e) Ponding test including supply of water for 72 hours after completion of water proofing work. Notes :- (i) Irrespective of lap the net covered area shall only be measured and paid (ii) The laying of membrane shall be got done through an authorised applicator of manufacturer of the membrane.
Material & Labour cement concrete tiles 25 cm x 25 cm x 22 mm thick, machine pressed (with grey cement and pigment), laid over and including 20mm thick screed bed in CM 1:4, set, jointed and pointed in neat cement slurry and pointed with mixture of gray cement and pigment to match the shade of the tiles complete all as specified and directed by Engr-in-Charge.
S&F 15 mm bore GI tubing medium grade including all fittings such as bends, socket, tees, elbows, unions, barrel, nipple, plugs, etc fixed to walls and ceilings with suitable size GI clamps or laid in floors including taking down old GI tubing including fittings complete all as specified.
Supply & fixing 25 mm bore Gun-metal, globe or gate valves , with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified .
M & L for disconnecting carefully all connections of existing tank PVC tank of capacity exc 1000 Ltr and n.exc 2000 Ltr , setting aside (or lowering if required) for cleaning / laying WPT etc and hoisting and reconnecting and re-fixing in the same position complete all as specified and directed by Engineer- in-Charge.
Material & Labour for 2000 lit capacity rotational moulded polyethylene water storage tank (Cylindrical vertical with closed top) including PVC cover with locking arrangement and making all connections for inlet, outlet, overflow and washout etc hoisted and fixed in position all as specified in SSR Part-I including PVC cover with locking arrangement complete all as specified.
Material & Labour for Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe 25 mm and fixed . (Minimum weight 455gms)
Supply & fixing PVC perforated caps screwed to ends of puff or vent pipes complete all as specified and as directed by Engineer- in-Charge.
Taking down PVC soil, waste and rain water pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, including cleaning or refixing or removal to store etc complete all as specified and directed by EIC.
Supply & Fixing 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with suitable size GI clamps complete all as specified .
Material & Labour for PVC (SWR) bend 110 mm bore fixed with rubber ring joints .
SCHEDULE 'A' PART II ( E/M WORKS) Taking down carefully copper / aluminium point wiring (light, fan socket or power) through steel / PVC conduit / casing caping including complete fittings such as switches, ceiling roses, pendants, regulators, sockets, buzzer, bell, switch sockets, etc removing and making good to the disturbed surfaces of walls/ceiling etc, with its original specification complete all as specified and directed.
Taking down old U/s tube light fittings of any description and capacity from wall/ ceiling and making good disturbed surfaces as per existing complete all as specified and directed
Taking down old U/s MCB DB's complete including MCB, Isolator etc. of any description and capacity from wall/ ceiling and making good disturbed surfaces as per existing complete all as specified and directed
Material & Labour for point wiring with 1.5 sqmm (nominal area) PVC insulated and unsheathed multistranded FRLS copper conductor cable, ISI marked, 1100 volts grade drawn through and including suitable size surface PVC casing caping (ISI marked) with all accessories fixed on wall, ceiling etc. and terminated in and including surface PVC modular box with cover plate and frame of sutable size including 1.5 sqmm size PVC insulated, unsheathed, multistranded FRLS copper conductor cable, ISI marked, for continuous earth conductor and connecting to earth dolly for one light point controlled by one switch 5 Amp, SP, one way 240 volts. Note: i) Colour coding shall be as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green
-Ditto- as per item No 40.00 above but one fan point controlled by one switch 5 Amp, SP, one way 240 volts.
-Ditto- as per item No 40.00 above but one bell point controlled by one switch 5 Amp, SP, one way 240 volts.
Ditto- all as per item No 40.00 above but One 3 pin 5 Amps switch socket on independent board.
-Ditto- all as per item No 40.00 above but One 3 pin 5 Amps socket on same board
Material & labour for point wiring ( for work station for computer) with 2.5 Sqmm (nominal area) PVC insulated and unsheathed multistranded FRLS copper conductor cable, ISI marked, 1100 volts grade drawn through and including suitable size surface PVC casing caping double deck type (ISI marked) with all accessories fixed on wall, ceiling etc. and terminated in and including surface PVC modular box of sutable size including 2.5 Sqmm size PVC insulated, unsheathed, multistranded FRLS copper conductor cable, ISI marked, for continuous earth conductor and connecting to earth dolly for each work station comprising of 03 Nos 6 Amp switch socket and 1 No 15 Amps switch socket on one board complete all as specified. Note: i) Colour coding shall be as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green
Material & labour for point wiring with 4 Sqmm (nominal area) PVC insulated and unsheathed multistranded FRLS copper conductor cable, ISI marked, 1100 volts grade drawn through and including suitable size surface PVC casing caping double deck type (ISI marked) with all accessories fixed on wall, ceiling, truss etc.and terminated in and including surface PVC modular box of sutable size including 4 Sqmm size PVC insulated, unsheathed, multistranded FRLS copper conductor cable, ISI marked, for continuous earth conductor and connecting to earth dolly for each work station comprising of 02 Nos 5/6 Amp switch socket and 1 No 15/16 Amps switch socket on one board complete all as specified. Note: i) Colour coding shall be as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green
S&F exhaust fan 300mm sweep, heavy duty metalic body, 1325 RPM suitable for working on 230 V, 50 HZ, AC supply, air delivery 1050 Cum / hr, power 31W complete with louvers, fixed with suitable size GI bolts, nuts and washers duly grouting new hanger fasteners of size 50mm x 10mm - 4 Nos including connecting up with 0.75 Sq.mm. size 3 core PVC insulated flexible cable with multi-stranded copper conductor from ceiling rose to connector of exhaust fan complete all as specified.
Taking down carefully wall mounted fan of any make, type and sweep, opening the motor, removing of old grease, washing and cleaning properly, heating, varnishing, greasing including testing and refixing in same position including applying one coat of synthetic enamel paint by spray painting including numbering of MES No with max 7.5 mm size letter with black pfu paint complete all as specified
Taking down carefully ceiling fan of any make, type and sweep, opening the motor, removing of old grease, washing and cleaning properly, heating, varnishing, greasing including testing and refixing in same position including applying one coat of synthetic enamel paint by spray painting including numbering of MES No with max 7.5 mm size letter with black pfu paint complete all as specified
Supply, laying,connecting & testing 16 Sqmm x 4 core XLPE insulated armoured heavy duty 1100 volts grade, aluminum conductor cable laid in ducts / pipes / fixed on wall with suitable size GI clamps complete all as specified and directed.
Material & Labour for sub-main wiring with 2 runs of 4 Sqmm multi-stranded copper conductor cable (FRLS grade), 1100 volts grade PVC insulated and unsheathed, ISI marked, drawn through and including heavy grade PVC casing and caping, ISI marked, not less than 25 mm wide (internal width) with all accessories like tees, elbows, junction boxs, reducer etc as required, including one run of 4 Sqmm multi-stranded copper conductor cable (FRLS grade), 1100 volts grade PVC insulated and unsheathed, ISI marked as earth dolly/mains complete all as specified and directed. Note: (a) Colour coding shall be as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) 2 runs of 4 Sqmm cable, One run of 4 Sqmm earth cable and PVC casing and caping shall be measured and paid as one length only.
Material & Labour for sub-main wiring with 2 runs of 6 Sqmm multi-stranded copper conductor cable (FRLS grade), 1100 volts grade PVC insulated and unsheathed, ISI marked, drawn through and including heavy grade PVC casing and caping, ISI marked, not less than 25 mm wide (internal width) with all accessories like tees, elbows, junction boxs, reducer etc as required, including one run of 6 Sqmm multi-stranded copper conductor cable (FRLS grade), 1100 volts grade PVC insulated and unsheathed, ISI marked as earth dolly/mains complete all as specified and directed. Note: (a) Colour coding shall be as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) 2 runs of 6 Sqmm cable, One run of 6 Sqmm earth cable and PVC casing and caping shall be measured and paid as one length only.
Supply & fixing LED recess mounting type fitting, 36 Watt 2' x 2' , not less than 125 lum/ watt with powder coated CRCA housing LED slim full glow panel with all accessories, including control gear and lamp including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified.
Supply & fixing new generation 20 Watt, 4 feet, LED batten luminarious, for surface / pendent application, anodised aluminium housing, high transmissitvity diffuser high lumen output of not less than 125 lum/ watt including all accessories and connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified.
Supply, laying,connecting & testing 10 Sqmm x 4 core XLPE insulated armoured heavy duty 1100 volts grade, aluminum conductor cable laid in ducts / pipes / fixed on wall with suitable size GI clamps including takiing out old cable complete all as specified and directed.
Supply, laying,connecting & testing 25 Sqmm x 4 core XLPE insulated armoured heavy duty 1100 volts grade, aluminum conductor cable laid in ducts / pipes / fixed on wall with suitable size GI clamps including takiing out old cable complete all as specified and directed.
Supply & fixing Modular switch 1 way 6 Amps, 1 module, 240 Volts ISI (Marked) complete all as specified.
Supply & fixing Modular switch 1 way 16 Amps, 1 module, 240 Volts ISI (Marked) complete all as specified.
Supply & fixing modular socket 6 Amps, 2/3 pin, 240 volts, 2 module ISI (Marked) complete all as specified.
Supply & fixing modular socket 16 Amps, 2/3 pin, 240 volts, 2 module ISI (Marked) complete all as specified.
Supply & fixing modular fan regulator, 120 W , 2 module, step type ISI (Marked) complete all as specified
Supply & fixing bell push modular type 16 Amps, 240 volts, 2 module ISI (Marked) complete all as directed.
Supply & fixing ceiling rose surface bakelite 65 x 50mm, three terminals ISI (Marked) complete all as specified and directed by Engineer-in-Charge.
Supply & fixing bell ding dong AC, 230 volt,single pole complete all as specified .
Supply & Fixing sheet metal enclosure double door type, prewired, made out of CRCA sheet epoxy powder coating and IP54 & IK 09 protection DB VTPN 8 way, 240 volts AC factory made with copper bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB TPN complete all as directed.
Supply & Fixing in repair Distribution Board double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection surface mounting SPN 8 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc complete all as directed. Note : The cost of removing old wooden box and making good of surface i.e. brick work, plastering etc is included in quated rate.
Supply & Fixing in repair Distribution Board double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection surface mounting SPN 12 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc complete all as directed. Note : The cost of removing old wooden box and making good of surface i.e. brick work, plastering etc is included in quoted rate.
Supply & fixing ceiling fan BLDC 1200mm sweep, 230 V, 50 HZ, AC supply, having air delivery not less than 225 Cum/Min, 350 rpm, single phase, including down rod as per site requirement including connecting up with 0.75 Sq.mm. size 3 core PVC insulated flexible cable with multi-stranded copper conductor from ceiling rose to connector of fan complete all as specified.
Supply & fixing MCCB, 4 pole, thermal release range 100 Amps of breaking capacity 16kA, 415 Volts, 50 HZ complete all as specified.
Supply & fixing MCB SP 240 Volts, 50Hz, 10 kA, conforming to IS 8828 of rating 6 to 32 Amps 'C' series ISI marked complete all as specified.
Supply & fixing MCB SP 240 Volts, 50Hz, 10 kA, conforming to IS 8828 of rating 40 to 63 Amps 'C' series ISI marked complete all as specified.
Supply & fixing MCB SPN 240 Volts, 50Hz, 10 kA, conforming to IS 8828 of rating 40 to 63 Amps 'C' series ISI marked complete all as specified.
Supply , fixing, testing in repairs of JEF ECO SAFE Maintenance Free Grounding Solution set comprising of High tensile low carbon steel rod of 3 Mts length & 25 mm dia with 250 micron ( avera Schneider ) molecularly bonded copper on the outer surface to confirm with requirements of UL467 along with Back-fill compound strictly be a Carbon based conductive concrete type which has a resistivity of less than 0.12 Ohm Mtr as per Clause 14.5D of IEEE : 80 standard. Back-fill compound should be electronically conductive ( Like in metals ) and should not depend on moisture for conduction. JEF Powerfill Loresco compound shall be supplied in 50 Pound Bag. ( 1 Bag of 50 Pounds required per earthing set). Back-fill comound should be environment friendly, should solidify when mixed with water and set like concrete and should not leach / diffuse into the ground. A suitable earth terminaton clamp should also be supplied along with the set alongwith earth pit weatherproof incl all as specified . Note : Back-fill compund shall not be mixed with any soil while pouring in the bore hole.
Material & labour for 4mm dia galvanised iron earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing complete all as specified .
ROHIT CONSTRUCTION (BID ID -3121959)
RAJENDRA CONSTRUCTION (BID ID -3121277)
Garima Construction Co (BID ID -3122533)
Nexus Infratech (BID ID -3121590)
Shetty Construction Co (BID ID -3120750)
ASHOK CONSTRUCTION (BID ID -3121709)
RS Enterprises (BID ID -3121650)
RAMESH ENTERPRISES (BID ID -3122342)
MUKESH CONSTRUCTION CO (BID ID -3121574)
stage.html
html • 0.07 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .