Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.3 LAccepted-AOC | L1 | Accepted-AOC being lowest | |
| 2 | L2₹8.4 L+₹13.31 (<0.01%)Rejected-Finance | L2 | Rejected-Finance Being not lowest |
Tender Value
₹9.3 L
EMD Value
₹19,000
Closing Date
8 May 2024, 6:00 pmClosed
AGE (I) Fatehgarh
AGE (I) Fatehgarh
ADDN/ALTERATION TO BLDG NO P-239 OFFICERS MESS AT MH FATEHGARH AND PROVN OF VIP CAR SHED AT CARIAPPA TRG COMPLEX AT RAJPUT REGT CENTRE FATEHGARH CANTT
2024_MES_649217_1
AGE(I)/FAT/ET-67 OF 2023-2024
Open Tender
Miscellaneous Works
Works
180 days
AGE (I) Fatehgarh
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
AGE (I) Fatehgarh
₹19,000
Yes
15 Jun 2024
6 Apr 2024
14 May 2024
6 Apr 2024
8 May 2024
20 Apr 2024
6 Apr 2024 - 19 Apr 2024
Amount
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, n exc 10 sqm on plan and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
M & L for surface dressing n.exc. 15 cm deep and getting out in soft/loose soil complete all as specified and directed.
Removing Excavated material n. Exc. 50m and depositing where directed at a level n. Exc. 1.5m above the starting point etc complete all as specified and directed.
M & L Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface(Broken stones / boulders) etc complete all as specified and directed.
M & L PCC 1:4:8 type D-2 as in foundations, filling and mass-concrete etc complete all as specified and directed.
M & L for PCC 1:2:4 type B-1 (using 20mm graded stone aggt) as in kerb stone, coping and all other siilar works including necessary formwork etc complete all as specified and directed
M & L RCC Nominal mix 1:2:4 type B-1 (using 20 mm graded stone aggt) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete etc complete all as specified and directed.
M&L for RCC Type B1 1:2:4 Nominal mix (20 mm graded aggregate) as in beams, cantilevers, bressummers, lintels bends including nacessary form work etc. complete all as specified
M & L RCC Nominal Mix 1:2:4 type B-1 (20 mm graded stone aggt) as in Columns, pillars, piers, posts and struts etc complete all as specified and directed.
M & L brick work with subclass `B' bricks, (old size) straight or curved on plan exc 6m mean radius, built inin CM 1:6 in superstructure etc complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan to any radius in half brick thick wall built in CM 1:4.complete all as specified and directed.
M & L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter etc complete all as specified and directed.
M & L for form work as in Linel /Tie beams etc complete all as specified and directed.
M & L for form work as in sides of columns etc complete all as specified and directed.
Taking down Chowkhats or frames with shutters (without taking off shutters from the frames) exc 1.5 sqm but not exc 4.0 sqm each complete all as specified and directed
S&F Door closer aluminium die cast body hydraulically regulated,designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed
M & L for Wire netting of galvanised steel wire 1.40mm dia fixed with tinned tacks of wire staples or welding etc complete all as per specified and directed.
S&F galvanized stainless steel wire cloth 0.36 mm nominal dia of wire & average width of aperture 1.40mm & fixed with tinned tacks or stainless steel staples complete all as spd & directed for gauged steel windows W/O glazing bars
M & L Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc complete all as specified and directed.
M & L for MS TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders etc complete all as specified and directed.
S & F for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, holdfasts, pintel higes etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete
S & F Steel work as in tubular trusses and purlins including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 etc complete all as specified and directed.
S&F powder coated Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified
S&F powder coated Anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos,sliding bolt( 250 mm) 02 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified.
S&F Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, tower bolts(4 no.),screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) in each window complete all as specified.
S & F for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and directed.
M & L for 75 mm thick PCC 1:4:8 type D-2 (using 40mm graded aggregate) as in sub base all as specified and directed.
M & L for 100 mm thick Cement concrete type D-2, 1:4:8 (40mm graded aggregate) complete all as specified and directed.
M & L for Glass dividing strips, 3 mm thick, 28mm of width and inserted in position, conform to design etc complete all as specified and directed.
Taking down Cement Plaster on Brick / Concrete surfaces incl raking out joints, hacking for key scrubbing down with water and Removing Rubbish off the Defence land.
M & L for two coat of Synthetic enamel paint over a coat of red oxide primer inclung preparation New steel surfaces or old previously untreated steel surfaces description, over 10cm in width or girth, not otherwise described complete all as specified and directed.
Demolition of Two way Trellis work (Jafri), including taking as under of battens in trellis (posts and rails measured separately) complete all as specified and directed
M & L for PCC 75mm thick 1:3:6 type C-1 using stone aggt 20mm as in plinth protection incl joint filling with bitumen and coarse sand mixture. 1:3 by weigh at the joints complete all as specified and directed.
M & L for 75mm thick Cement concrete type B-1, 1:2:4 (20mm graded aggregate) for flooring finished even and smooth without using extra cement including laid in alterntive bays etc complete all as specified and directed.
M&L for 15mm thick cement plastering in cm 1:6 on brick or concrete surface fair finished the surface even and smooth without using extra cement all as specified
M&L for rendering 15mm thick plaster in CM 1:4 on fair faces of brick work even and smooth without using extra cement complete all as specified.
M & L for preparation of new plastered surfaces of walls and making surface smooth and applying two coats of OBD over a coat of chalk whitening over 1mm thick wall care putty complete all as directed.
M & L for preparation of old plastered surfaces of walls by complete removal of existing treatment and making surface smooth and applying two coats of OBD over a coat of chalk whitening over 1mm thick wall care putty complete all as directed.
M & L two coat of cement based paint on new plastered wall surfaces with priming with alkali resistant primer including preparation complete all as specified
S&F 5.5 mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane all as specified
M & L for preparation of new plastered surfaces of walls and applying three coats of white wash on walls complete.
M&L 20-25 mm thick machine cut kota stone as in flooring laid over 20 mm thick screed in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab incl rubbing and mirror polishing complete.
M&L 16-18 mm thick machine cut kota stone as in skirting laid over 10 mm rendring in CM 1:3 laid and jointed with grey cement slurry mixed with pigment to match the shade of the tile incl rubbing and mirror polishing complete.
M&L Rolled mild steel Fe-410-W(Gde-E-250) quality-A in rolled sections as in main and cross beams, hip and jack rafters,purlins,posts where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and directed
S&F False Ceiling Horizontal level regular edge grid 600 x600 mm from work using hot dip sections and fixing tiles vinyl laminated MPL gypsum panels size 595x595x6 to 8mm thick after lamination, suspended the grid with grid hangers to Roof Truss / RCC Slab all as per manufactured instruction.
M&L Preparing new surfaces of steel and applying two coats of SE paint, complete all as specified and as directed.
Taking down copper/aluminium point wiring of any description and any position (light, fan, socket or power point) complete, including fixture and fittings such as switches,socket, ceiling rose,lamp holder,pendants, bracket and regulator etc and removing material from site including making good disturbed surface to match with the existing surface complete all as specified and as directed .
Taking down Aluminium/copper sub main wiring and making good disturbed surfaces to match with the existing surface roof/wall/floor complete all as specified and as directed .
M&L for point wiring with 1100 volt grade PVC insulated and unsheathed 1.5 Sq mm (FRLS) multistranded copper conductor cable with continuous earth wire of 1.5 Sq mm (FRLS) multistranded copper conductor cable PVC insulated and unsheathed, drawn in & including concealed PVC rigid conduit medium grade with fittings (ISI marked) sunken pressed steel galvanised terminal boxes with top cover ISI marked plastic laminated hylam sheet for housing/ fixing switches etc for One light/fan/exhaust fan point controlled by one switch complete all as specified and directed for the following- Note- (i) The quoted rete is deemed to be included for the chases cutting. (ii) Cutting chases for concealed shall be made good using CM 1:4 and surface finished to match the existing surface & colour.
All as per item above but for One 5 pin 5 Amp switch socket combination point on an independent board.
All as per item above but for One 5 pin 5 Amp socket point controlled by one switch on same board.
All as per item above but for one 16 Amp 6 Pin switch socket combination independent with 4.0 Sqmm FRLS unsheathed copper conductor single core multistranded complete all as specified.
S&F Switch Piano flush type 6 Amp single pole one way complete all as specified and as directed .
S&F Socket outlet 2 in 1, 3 pin, 6 Amp complete all as specified and as directed .
S&F Switch socket combination 2 in 1 flush type 6 Amp 5 Pin complete all as specified and as directed .
S&F Switch socket combination 2 in 1 flush type 16 Amp 5 Pin complete all as specified and as directed .
Supply and fix electronic fan regulator 5 stepped type complete all as specified and directed
S&F ceiling rose PVC/Poly carbonate isolated body three terminal AC 230 volts complete all as specified and directed.
M&L for sub main wiring with two single core 6 Sqmm FRLS copper conductor PVC insulated and unsheathed cable including PVC conduit medium grade (appropriate size) concealed in wall for sub main connection including 6 Sqmm FRLS insulated multistranded unsheathed copper conductor used as a earth wire to common earth and connection to earth dolly complete all as specified and as directed. ( Note :- Two runs of 6 sqmm FRLS and one run of 6 sqmm FRLS copper conductor shall be measured as one unit length.)
Supply and fixing of VTPN DB suitable for Mounting MCCB as Incomer of rating 100 Amp Vertical distribution board 12 way with suitable rated bus bar having IP-43 protection and double metal door concealed in wall including connection with aluminium thimbles as required complete all as specified.
S&F of MCCB 100 Amp, 16KA, 4 Pole including complete electrical connection by appropriate size of copper lugs complete all as specified and directed
S&F MCB in repair of MCB SP 6 to 32 Amp 240 Volt 'C' curve 10 KA complete all as specified and directed.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.
S & F building security LED Light 30 Watt made up pressure die-cast aluminium housing with high power LED as lighting source and lens embedded PC having top opening separate driver compartment with IP-65 protection and impact resistance of IK 07 for building secuity purpose with bracket size made of GI pipe medicum grade 40 mm dia 1.5 mtr long bend to shape as required and fixing with two nos MS Clamp of size 40x6 mm for fixing of builiding security light fittings completed all as specified and directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep min air delivery 210 CFM with service value 6.00 BEE five star rated complete all as specified and driected.
Supply and fixing exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all as specified and directed
Supply, laying & testing cable XLPE insulated , screened, PVC bedded, galvanized steel trip or wire armoured electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade with standed aluminium conductor of size 25 Sqmm 3.5 core including taking down of cable complete all as specified and directed. .
Excavation in trenches n. exc 1.5 m wide and n.exc 1.5 m in depth and getting out soft /loose soil complete all as specified and as directed for laying of under ground cable, foundation of pole and stay etc. complete all as specified and as directed
Returning, filling in, including spreading, levelling, watering and well remmining in layers not exc 25 cm complete all as specified and as directed
Removing excavated material n.exc 50 m and depositing where directed at a level n. exc 1.5 m above the starting point all as directed.
M & L Sand cushioning for U/G cables in layers of 23 cm thick (8cm before laying the cable and 15cm thick after laying the cable) in trenches complete and all as specified and directed . ( Note : Punned down volume shall be measured )
Supply and lay burnt best quality locally available old size sub class 'B' bricks laid in trenches perpendicular to U/G cable for cable protection complete all as specified and as directed.
M/S Shree Gopal Engineers & Contractor
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .