| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹135.6 CrAccepted-AOC A 18 SECTOR 136 NOIDA UTTAR PRADESH 201304 | NOIDA | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201304 | ₹135.6 Cr Quoted ₹136.7 Cr | L1 | Accepted-AOC Work awarded on Negotiated value |
| 2 | L2₹192.1 CrRejected-AOC | ₹192.1 Cr | L2 | Rejected-AOC Rejected |
Tender Value
₹112.7 Cr
EMD Value
₹2.3 Cr
Closing Date
14 Feb 2024, 3:00 pmClosed
Director (Technical), RSDCL
E-166, Yudhisthir marg, C-scheme, Jaipur
Balance work for construction of 03 Nos. Park Pooling Station at Nokh Solar Park District- Phalodi
2024_RRECL_378629_1
RSDCL/TN-05 (2023-24)
Open Tender
Electrical Works
210 days
Nokh Phalodi Rajasthan
As per Bid document
3 documents required · 3 mandatory
₹29,500
MD RSDCL
₹2.3 Cr
Jaipur
7 Mar 2024
29 Jan 2024
14 Feb 2024
29 Jan 2024
14 Feb 2024
29 Jan 2024
2 Feb 2024
Amount
Structures/Beams with Nuts, Bolts & Washers etc. Complete.
AT4 (Short Members Approx.Weight)
AB1/2 Beam
Y with stub
Outdoor Equipments
220 KV/33 KV, 100 MVA Power Transformer with all accessories & 5% extra oil
220 kV Bus bar Reactor of 25 MVAr
220 KV Isolator with Single Earth Blade 2000 Amp (motor operated & double break type) 40 kA, 3 Sec.
220 KV Isolator with Double Earth Blade 2000 Amp (motor operated & double break type) 40 kA, 3 Sec.
220 kV Post Insulators (including for isolators)
33KV Isolator with single Earth Blade 1250 Amp, 31.5 kA, 1 Sec
33 KV Current Transformer: 2400 / 1A, 4C class 0.2S, 31.5 kA, 1 Sec.
33 / 0.4 KV, 250 KVA Station Transformer
11/0.4 KV, 100 KVA Station Transformer (For alternate Aux. supply from DISCOM)
33 KV H.G. Fuse (Set for 3 phases) with supporting structures
11 KV H.G. Fuse (Set for 3 phases) with supporting structures
Control Room Equipments
Battery Set 220 Volts, 400 AH
Lighting Distribution Board
Bus Bar Material
Single/ Double Tension Hardware for double AL-59 (Moose equivalent and equivalent weight zebra) (Bolted type)
Single/ Double Tension Hardware for twin Tarantulla
Single/ Double Suspension Hardware for twin Tarantulla
Earth Wire Tension Hardware 7/3.15 mm
Clamps & Connectors i.e. PG-clamps, T-clamps, PI clamps, Bus bar spacers etc and terminal connectors for Equipments for AL-59 (Moose Equivalent and weight equivalent to zebra) conductor as per specification requirement.
Clamps & Connectors i.e. PG-clamps, T-clamps, PI clamps, Bus bar spacers etc and terminal connectors for Equipments for AAC Tarantulla conductor as per specification requirement (PANTHER for jumper of 33 kV PT only)
Copper Control Cables of assorted size
LT Power Cable (Aluminum) 3.5C X 35 Sqmm
Earthing Material
M. S. Round 40 mm. dia.
M. S. Flat 75x12mm
M. S. Flat 50 x12 mm
M. S. Flat 50 x 8 mm
M. S. Flat 50 x 6 mm
Others
GI Channel 100 x 50 x 6 mm
ISI marked insulating mats for electrical purpose (Rubber mating of size 05m x 01m x 3mm)
Lighting/ Illumination (LED Lighting)
In Switchyard Area
Street light from main Gate upto Control Room & upto switchyard Gate
Fire Fighting Equipments
ISI Marked trolley mounted Fire Extinguishers mechanical foam type 9 litres as per specification
ISI Marked trolley mounted Fire Extinguishers dry powder (Cartridge type) 6 kg. as per specification
ISI Marked trolley mounted Fire Extinguishers dry powder (cartridge type) 9 kg. as per specification
ISI Marked trolley mounted Fire Extinguishers CO2 type 9 kg. as per specification
ISI Marked trolley mounted Fire Extinguishers CO2 type 4.5 kg. as per specification
ISI Marked Fire buckets along with stands (each stand suitable for 6 buckets) as per specification
PLCC Equipment with associated equipments & accessories
48V 360/600 AH maintenance Free Battery set alongwith accessories and stand
FOTE / OFC equipments
Control Cable 1.5 Sq mm 16 core
Serial to FO Converter item 9 pin FO cable for connection of SAS to FOTE beyond 10mt. Length both ends of FOTE & SAS
Telephone cable 10 pair unarmoured
Description of Work / Item(s)
Amount
Structures/Beams with Nuts, Bolts & Washers etc. Complete.
AB1/2 Beam
Wave trap structure
PIS type
X-15 for 33 KV Isolator
33 KV CT/ PT Structure
Y with Stub
GF 5.4m type beam
Outdoor Equipments
220 KV/33 KV, 100 MVA Power Transformer with all accessories & 5% extra oil
Nitrogen Injection Based Fire Protection System for 100MVA Transformer and 25MVAR Reactor
220 kV Bus bar Reactor of 25 MVAR
220 KV Circuit Breaker with mounting structure, 2000 Amp, 40 kA, 3 Sec.
220 KV Isolator without Earth Blade 2000 Amp (motor operated & double break type) 40 kA, 3 Sec.
220 KV Isolator with Single Earth Blade 2000 Amp (motor operated & double break type) 40 kA, 3 Sec.
220 KV Isolator with Double Earth Blade 2000 Amp (motor operated & double break type) 40 kA, 3 Sec.
220 KV Tandom isolator 2000 Amp (motor operated & double break type) 40 kA, 3 Sec.
220 KV Current Transformer: 500-1000/1A,5C, 0.2S class, 40 kA, 1 Sec.
220 KV Capacitor Voltage Transformer (CVT), 0.2 class including metering CVT
198 KV Lightning Arrester
220 KV Post Insulators (including for Isolators)
220 KV Marshalling Kiosk
33 KV Current Transformer: 2400/1A, 4C class 0.2S, 31.5 kA, 1 Sec.
33 KV Current Transformer: 500-1000/1A, 2C class 0.2S, 31.5 kA, 1 Sec.
33Kv CT/PT Junction Box
30 KV Lightning Arrester
33 KV Marshalling Kiosk
33 KV Vacuum circuit breaker with mounting structure, 2500 Amp, 31.5 kA, 3 Sec
33 KV Vacuum circuit breaker with mounting structure, 1250 Amp, 31.5 kA, 3 Sec
33 KV Potential Transformer
33KV Isolator without Earth Blade 2500 Amp, 31.5 kA, 1 Sec
33KV Isolator with single Earth Blade 2500 Amp, 31.5 kA, 1 Sec
33KV Isolator without Earth Blade 1250 Amp, 31.5 kA, 1 Sec
33KV Isolator with single Earth Blade 1250 Amp, 31.5 kA, 1 Sec
2*24 KV PI or 36 kV PI
33 / 0.4 KV, 250 KVA Station Transformer
11/0.4 KV, 100 KVA Station Transformer (For alternate Aux. supply from DISCOM)
33 KV H.G. Fuse (Set for 3 phases) with supporting structures
11 KV H.G. Fuse (Set for 3 phases) with supporting structures
Control Room Equipments
Control & Relay Panel for 220 KV feeder Type- SAS-FCB/FRB
Control & Relay Panel for 220 KV Transformer (220 KV side) Type- SAS-THCB/THRB
Control & Relay Panel for 220 KV Bus Coupler Type- SAS-BCCB & BCRB
Control & Relay Panel for 220 KV Transfer Bus Coupler Type- SAS-BTCB & BTRB
220 kV Bus bar Protection Scheme Type- SAS-BBRB
Control & Relay Panel for 25 MVAR Reactor (220 kV Side) Type- SAS- RCB & RRB
Substation Automation Network Panel Type-SAS-NW
Substation Network Panel Type-SAS-FN
Time Synchronization and Gateway Panel, Type-SAS-TSE/GW
Substation Auxiliary Monitoring Panel, Type- SAS-SAMP
Control & Relay Panel for 33 KV Transformer incomer+ Bus Coupler Panel (combined for incomer+ Bus Coupler, Type- SAS-FCRD
Control & Relay Panel for 33 KV Feeders / SectionliserType- SAS-FCRD (each panel compraises two feeders)
Battery Set 220 Volts, 400 AH
Battery Charger 220 Volts, 400 AH
220 Volts DC Distribution Board (With 2 Nos. I/C & auto change over facility)
L. T. Panel 800A
Lighting Distribution Board
Outdoor AC Distribution Box:(i) For 220kV Bays: 1 I/C 100A & 12 O/G 16A
Outdoor AC Distribution Box:(ii) For 33kV Bays: 2 I/C 100A & 24 O/G 16A
Bus Bar Material
Single Tension Hardware for AL 59 (Moose equivalent and Eq. wt. Zebra) (Bolted type)
Single/ Double Tension Hardware for Double AL 59 (Moose equivalent and Eq. wt. Zebra) (Bolted type)
Single/ Double Suspension Hardware for Double AL 59 (Moose equivalent and Eq. wt. Zebra)
Single/ Double Tension Hardware for Twin Tarantulla
Single/ Double Suspension Hardware for Twin Tarantulla
Disc Insulators, 120 KN
Disc Insulators, 70 / 90 KN
AL-59 Conductor (Moose equivalent and Eq. wt. Zebra)
AAC Tarantula conductor
Earthwire (7 / 3.15 mm)
Earthwire Tension Hardware, 7 / 3.15 mm.
Clamps & Connectors i.e. PG-clamps, T-clamps, PI clamps, Bus bar spacers etc and terminal connectors for Equipments for AL-59 (Moose equivalent and weight equivalent to Zebra) conductor as per specification requirements, .
Clamps & Connectors i.e. PG-clamps, T-clamps, PI clamps, Bus bar spacers etc and terminal connectors for Equipments for AAC Tarantulla conductor as per specification requirements
Clamps & Connectors i.e. PG-clamps, T-clamps etc for Earthwire as per specification requirements
Copper Control Cable
Copper Control Cables of assorted size
LT Power Cable (Aluminium)
3½ core x 300 sq. mm
3½ core x 35 sq. mm
Earthing Material
M. S. Round 40 mm. dia
M. S. Flat 75x12mm
M. S. Flat 50 x12 mm
M. S. Flat 50 x 8 mm
M. S. Flat 50 x 6 mm
M.S. Pipe electrode 40mm
Others
GI Channel 100 x 50 x 6 mm
ISI marked insulating mats for electrical purpose (Rubber mating of size 05m x 01m x 3mm) for control rooms
Lighting/ Illumination (LED Lighting)
In Switchyard Area
Street light from main Gate upto Control Room & upto switchyard Gate
Fire Fighting Equipments
ISI Marked trolley mounted Fire Extinguishers mechanical foam type 9 litres as per specification
ISI Marked trolley mounted Fire Extinguishers dry powder (Cartridge type) 6 kg. as per specification
ISI Marked trolley mounted Fire Extinguishers dry powder (cartridge type) 9 kg. as per specification
ISI Marked trolley mounted Fire Extinguishers CO2 type 9 kg. as per specification
ISI Marked trolley mounted Fire Extinguishers CO2 type 4.5 kg. as per specification
ISI Marked Fire buckets along with stands (each stand suitable for 6 buckets) as per specification.
PLCC Equipment with associated equipments & accessories
Phase to Phase Coupling Devices (each set consisting of LMU + LMDU).
HF Coaxial cable having 75 Ohms unbalanced impedance
Digital Signal processor based 40W SSB single Channel Carrier Set (PLCC Panel) suitable for transmitting Data and super imposed channels alongwith fully functional Remote subscriber facility and emergency calling set (With protection coupler)
48 V, 50/100 Amp, SMPS based battery charger with N+1 configuration suitable for VRLA maintenance free batteries
48V 360 AH maintenance Free Battery set alongwith accessories and stand.
48 V DCDB
Wave traps 0.5 mh / 1600A. with tuning unit, Protection device, terminals clamps, bird barriers etc. (Pedestal type)
FOTE / OFC equipments
Fully wired cabinate with base19" equipment rack (including front cover, cable,tray common cards) with fan and control, synchronization, alarm dual power supply input cables
Central Processing Unit CPU(CESM)
OFC patch cord (set of 48 Nos.)
8 Port 2W/4W E&M Interface cards
4 Port Data Interface Card(Programmable)
4 Command Integrated Tele protection card
Engineering Order wire Phone
Control Cable 1.5 Sq mm 16 core
Serial to FO Converter item 9 pin FO cable for connection of SAS to FOTE beyond 10mt. Length both ends of FOTE & SAS
Telephone cable 10 pair unarmoured
OLTE-1/4 and 4/16 port STM-16 along with SFP U16.1
Differential prot. OPIC2 with SFP
SFP for integration with existing SDH
Description of Work / Item(s)
Amount
Outdoor Equipments
220 KV Circuit Breaker with mounting structure, 2000 Amp, 40 kA, 3 Sec.
220 KV Isolator without Earth Blade 2000 Amp (motor operated & double break type) 40 kA, 3 Sec.
220 KV Isolator with Single Earth Blade 2000 Amp (motor operated & double break type) 40 kA, 3 Sec.
220 KV Isolator with Double Earth Blade 2000 Amp (motor operated & double break type) 40 kA, 3 Sec.
220 KV Tandom isolator 2000 Amp (motor operated & double break type) 40 kA, 3 Sec.
220 KV Current Transformer: 500-1000/1A,5C, 0.2S class, 40 kA, 1 Sec.
220 KV Capacitor Voltage Transformer (CVT), 0.2 class including metering CVT
198 KV Lightning Arrester
33 KV Current Transformer: 500-1000 / 1A, 2C class 0.2S, 31.5 kA, 1 Sec.
33 KV Vacuum circuit breaker with mounting structure, 2500 Amp, 31.5 kA, 3 Sec
33 KV Vacuum circuit breaker with mounting structure, 1250 Amp, 31.5 kA, 3 Sec
33 KV Potential Transformer
Description of Work / Item(s)
Amount
Site preparation including cutting,filling of earth and levelling,dressing of complete sub station area
Grading and Gravelling of switch yard area as marked in Electrical Layout plan,enclosed with volume-III as per specification clause No.4.0 (For PPS-1, PPS-2 & PPS-3)
Drainage system of Control room bldg,dormitory,switch yard & approach road including rain water harvesting system as per specification clause No.5.0, Vol-III (For PPS-1, PPS-2 & PPS-3)
Construction of A class 3.00 mtr wide road with shoulder & with kerb stone on both side including culvert as per specification clause No.6.0,Vol-III (For PPS-1, PPS-2 & PPS-3)
Construction of A class 3.00 mtr wide road without shoulder & without kerb stone on both side including culvert as per specification clause No.6.0,Vol-III (For PPS-1, PPS-2 & PPS-3)
Construction of AA class 4.00 mtr wide road including culvert with shoulder and kerb stone on both side as per specification No.6.0,Vol-III (For PPS-1, PPS-2 & PPS-3)
Construction of foundation of AO1 structure (As per Annexure-12 & S. No. 11 of 12(A)) (For PPS-1, PPS-2 & PPS-3)
Construction of foundation of AO1-T structure (for PPS-3) as per S. No. 12 of Annexure 12(A)
Construction of foundation of PIS Type structure (As per Annexure-12 & S. No. 16 of 12(A))
Construction of foundation of X-15 (For 33kV Isolator) structure (As per Annexure-12 & S. No. 17 of 12(A))
Construction of foundation of 33kV CT/PT structure (As per Annexure-12 & S. No. 18 of 12(A))
Construction of foundation of 33 kV Breaker (for PPS-1) (As per Annexure-12 & S. No. 22 of 12(A))
Construction of foundation with Gravel/Boulder filling including civil work for oil collection in oil pit for 220/33 kV, 100 MVA Transformer (As per Annexure-12 & S. No. 23 of 12(A))
PPS-3 (ii)
Construction of foundation with Gravel/Boulder filling including civil work for oil collection in oil pit for 220 KV, 25 MVAR BUS Reactor (As per Annexure-12 & S. No. 24 of 12(A))
Civil works for oil collection in oil pit of 10000 litres capacity required for firefighting system in respect of 220/33KV, 100MVA Transformer and 25 MVAr Bus Reactor (For PPS-1, PPS-2 & PPS-3) (As per Annexure-12 & S. No. 25 of 12(A))
Construction of foundation of 33/0.4 kv, 250 KVA station Transformer(for PPS-2 & PPS-3) (As per Annexure-12 & S. No. 26 of 12(A))
Construction of foundation of 11/0.4 kv, 100KVA station Transformer (for PPS-2) (As per Annexure-12 & S. No. 27 of 12(A))
Construction of Type-Ax Cable Trenches including ferro cement cover (For PPS-1, PPS-2 & PPS-3) (As per Annexure-12 & S. No. 28 of 12(A))
Construction of Type-A Cable Trenches including ferro cement cover (For PPS-1, PPS-2 & PPS-3) (As per Annexure-12 & S. No. 29 of 12(A))
Construction of Type-C Cable Trenches including ferro cement cover (For PPS-1, PPS-2 & PPS-3) (As per Annexure-12 & S. No. 30 of 12(A))
Construction of Type-D Cable Trenches including ferro cement cover (For PPS-1, PPS-2 & PPS-3) (As per Annexure-12 & S. No. 31 of 12(A))
Providing & Laying PVC pipe Type B-150mm dia with accessories (for road crossing) (For PPS-1, PPS-2 & PPS-3) (As per Annexure-12 & S. No. 32 of 12(A))
Construction of Control room building & Rest rooms complete in all respect as per specification including cable trenches and 6mm thick chequerred plate covers inside control room, PLCC & Battery room & sanitary & Electric fittings etc. including illumination of control room & rest rooms as per specification clause 12.0, Vol-III (As per Annexure-12 & S. No. 33 of 12(A))
Supply, Installation and testing of 5 star rated, 2 Ton capacity split inverter AC indoor type with stabilizer 05 kva (make approved by Engineer-Incharge) in control room,PLCC room, incharge room, Rest rooms as per approved design and standard requirement of units including all required electrification works/items as per clause 12.0, Vol-III (For PPS-1, PPS-2 & PPS-3)
Supply, Installation and testing of 5 star rated, 1.5 Ton capacity split inverter AC indoor type with stabilizer 05 kVA (make approved by Engineer-Incharge) in control room, PLCC room, XEN room, Rest rooms as per approved design and standard requirement of units including all required electrification works/items as per clause 12.0, Vol-III (For PPS-1, PPS-2 & PPS-3)
Furnishing of control room building as per specification clause 12.0 & Annexure-1 of Vol-III (For PPS-1, PPS-2 & PPS-3)
Furnishing of Rest rooms & Dining room as per specification clause 12.0 & Annexure-2 of Vol-III (For PPS-1, PPS-2 & PPS-3)
Water cooler (40 litre) of Voltas/Blue star as per specification clause 11.0 & Annexure-4 of Vol-III.(with RO of sufficient capacity & reputed make) (For PPS-1, PPS-2 & PPS-3)
Construction of chain link fencing with toe wall as per approved drawing for switchyard as per clause 13.0 of specification of Vol-III (For PPS-1, PPS-2 & PPS-3)
P & F M.S. PSS Main Gate with Vicket gate, pillars , cattle catcher for entry to PSS premises as per clause 14.0 of specification, Vol-III (For PPS-1, PPS-2 & PPS-3)
P & F M.S. Switchyard Gate with pillars for entry to switchyard as per clause 14.0 of specification, Vol-III (For PPS-1, PPS-2 & PPS-3)
Construction of pucca parking area for six Nos. Cars with RCC Roofing & pavement as per specification (For PPS-1, PPS-2 & PPS-3)
Construction of Store shed as per drawing attached with the specification (As per Annexure-12 & S. No. 43 of 12(A))
Construction of Boundry wall of PPS with railing, barbed wire, Y-shape angle as per specification clause No.11, Vol-III (As per Annexure-12 & S. No. 44 of 12(A))
Construction of Under ground water storage tank size 5.0m x 3.0m x 2.0m with submersible electric motor of 2 HP capacity of approved make with switch board , starter to be placed in pump room to cater water supply for main water supply system and water pipe line to control room, rest rooms, dormitory, security hut and Transformer yard as per specification (For PPS-1, PPS-2, PPS-3)
Park/Lawn of 30.0 m x 12.0 m size with 0.60 m high boundary wall, 0.60 m M.S.Railing and entrance gate in front of control room/porch as per site requirement (For PPS-1, PPS-2, PPS-3)
Construction of security/Guard hut at main Gate of PPS (As per Annexure-12 & S. No. 47 of 12(A))
Providing & Fixing of Glow sign board at roof of control room bldg as per specification clause No.24.0, Vol-III (For PPS-1, PPS-2 & PPS-3)
Providing & Fixing of sign board at Ground near the entrance gate of GSS as per specification clause No.24.0, Vol-III (For PPS-1, PPS-2 & PPS-3)
Construction of Meter shed size 4.0m x3.0m x2.50m with GI sheet roofing (For PPS-1, PPS-2 & PPS-3)
Construction of Dormitory building with all sanitary, electrical, door, window fittings in all respect as per specification clause No. 23.0, Vol-III
PPS-1(As per Annexure-12 & 12(A))
PPS-2(As per Annexure-12 & 12(A))
PPS-3(As per Annexure-12 & 12(A))
Furnishing of Dormitory building as per specification clause no. 23.0 & Annexure-3, Vol-III (For PPS-1, PPS-2 & PPS-3)
Providing & Fixing Interlocking block in GSS premises near the control room, dormitory, parking as per specification clause No. 22.0, Vol-III (For PPS-1, PPS-2 & PPS-3)
Description of Work / Item(s)
Amount
Handholding of Substations
Total Lumpsum Charges for Handhlding of 12 months from date of Taking over of 220kV Park Pooloing Sub-station PPS-1 at Nokh Solar Park
Total Lumpsum Charges for Handhlding of 12 months from date of Taking over of 220kV Park Pooloing Sub-station PPS-2 at Nokh Solar Park
Total Lumpsum Charges for Handhlding of 12 months from date of Taking over of 220kV Park Pooloing Sub-station PPS-3 at Nokh Solar Park
Montecarlo Limited
Montecarlo Limited
Montecarlo Limited
Montecarlo Limited
Montecarlo Limited
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid