| 1 | L-1₹21.5 LAccepted-AOC | L-1 | Accepted-AOC being lowest bidder | |
| 2 | L-2₹28.9 L+₹2.0 L (7.41%)Rejected-Finance 201 GANAPATI SANKUL AGASHIVNAGAR MALKAPUR KARAD SATARA MAHARASHTRA 415539 | SATARA | MAHARASHTRA | 415539 | L-2 | Rejected-Finance Other than lowest bidder | |
| 3 | L-3₹30.8 L+₹3.9 L (14.4%)Rejected-Finance | L-3 | Rejected-Finance Other than lowest bidder | |
| 4 | L-4₹34.8 L+₹7.9 L (29.4%)Rejected-Finance | L-4 | Rejected-Finance Other than lowest bidder | |
| 5 | L-5₹35.4 L+₹8.5 L (31.5%)Rejected-Finance SIMBAL CAMP WARD NO 5 NEAR GURUDWARA SAHIB R S PURA DISTT JAMMU J K 1812104 | R S PURA | JAMMU | J K | 1812104 | L-5 | Rejected-Finance Other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹86,000
Closing Date
27 Jun 2022, 6:00 pmClosed
GE Jammu
GE Jammu c/o 56 APO Pin-900277
REPAIR, MAINTENANCE AND REPLACEMENT OF INTERNAL WIRING INCLUDING FITTINGS, SOLAR WATER HEATER, CEILING FANS, EXHAUST FANS, ELECTRIC GEYSERS AND CONNECTED WORKS AT SUNJUWAN, BALIDAN STAMBH, SAINIK ARAM GRAH UNDER GE JAMMU
2022_MES_527807_1
GEJC-20/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AoR of GE Jammu
Please refer Tender documents
9 documents required · 9 mandatory
₹500
GE Jammu
₹86,000
Yes
7 Oct 2022
1 Jun 2022
29 Jun 2022
1 Jun 2022
27 Jun 2022
14 Jun 2022
Amount
Charges for attending day to day/ E/M petty complaint in respect repair / rectification of fault in electric fitting MCB DB's, internal wiring LT panel and fixture and rectify the faults and replacement of unserviceable any type of fitting / fixture, MCB's, any type, bakellite sheet, restore the electric supply and made the item functionable light point, fan point, socket point 5A / 15A, switches, sockets, fan regulator, light fixtures any type of lamp, MCB DB's and all electrical accessories and day to day / door to door maintenance, making the points / accessories serviceable in all respect with replacement of any minor parts like small length of wires (not more than 1 metre) and other connected minor accessories. Work shall also include to check and removal of leakage in service connection / submains of houses as and when directed. The scope also include cutting of existing bakellite sheet to accommodate new wiring accessories all type of electric fitting / fixture.
Note : Any other replacement of major items shall be measured and paid under respective items as supply only. Fixing charge of fitting / fixture and MCB's of any type is deemed to be included in the above item.
(i) Contractor representative / Engineer will report to complaint cell for morning and afternoon to collect routine / urgent nature of complaint related to internal electric supply till completion of contract. The work shall be attended by the contractor immediately. The contractor will ensure availability of manpower (Two Electrician and Two Helper) equipped with all sort of petty items such as insulation tape, galvanised screws, nuts, bolts, washers etc required to accomplish the job. The contractor will also ensure availability of every type of requisite T&P items to his tradesman. All routine / urgent job received on job slip will be repaired and got signature of users and will be deposited to complaint cell within 24 hours. In case of any delay in attending the complaint more than 12 hours after handing over of routine / urgent works, the contractor shall be liable to pay the penalty as per the item rate. (ii) Contractor shall maintain the maintenance register showing all daily complaints received and shall maintain job card for attending complaints. The signature of the user shall be obtained on the job card showing the materials used in the work after completion of the job. (iii) If the Contractor did not attend complaints, a penalty of Rs 300/- per day per complaint recovery shall be made from the work done amount. (iv) The MES Department is not responsible for the payment of staff hired by contractor for complaint rates for attending the complaints by the electrician are deemed to be included in the item for repair i.e. Electrician / Helper, as all the items of CA are to be supply and fixed by the contractor. (v) Proper record (date wise) of complaints received and rectified by the contractor shall be produced for verification at the time of payment of each RAR / Bill. (vi) All the complaint slip, register and connected documents will be provided by the contractor without any extra cost. (vii) After any repair the site has to be cleaned and make the surface good.
Supply only switch piano, flush type single pole one way 5 Amp, 240 volts ISI marked complete all as specified and directed.
Supply only socket outlet 2 in 1, 3 pin, 5 A complete all as specified and as directed.
Supply only switch socket outlet combined 5 pin 5 amp flush type, 240 volts ISI marked complete all as specified and directed.
Supply only switch socket outlet combined 2 in 1, 3 pin, 5 amp and 15 amp flush type, 240 volts ISI marked complete all as specified and directed.
Supply only socket outlet 3 pin, 15 Amp, flush type, 240 Volts, 6 pin flush type complete ISI marked all as specified and directed.
Supply only switch piano, flush type single pole one way 15 Amps, 240 volts ISI marked complete all as specified and directed.
Supply only ceiling rose 3 terminal surface type complete all as specified and as directed.
Supply only lamp holder, PVC / Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.
Supply only bell, AC 230 Volts single pole complete all as specified and as directed.
Supply only bell push flush type single pole one way 5 amp complete all as specified and as directed.
Supply only holder any type for batten fitting including taking old one ISI marked complete all as specified and directed.
Supply only MCB SP 6 to 32 Amps, 240 Volt 'B' series complete all as specified and as directed.
Supply only SPN 32 Amp rating 240 V, 10 KA 'B' curve miniature circuit breaker (MCB) complete all as specified and as directed.
Supply only SPN 40 to 63 Amp rating 240 V, 10 KA 'B' curve miniature circuit breaker (MCB) complete all as specified and as directed.
Supply only stepped type electronic fan regulator flush type as required complete all as specified and as directed.
Taking down old unserviceable copper / aluminium point wiring concealed / batten (light, fan, socket or power) complete, including fixture and fittings such as switches, sockets, ceiling roses, bell push, bell electric, lamp holder, bulk head fitting, pendants, regulators, sockets, light fitting and any type switch board wooden / iron, round block etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed.
Material and labour for point wiring for one light / fan / call bell point controlled by one 5 Amp switch with 1.5 Sqmm single core multistranded copper conductor FRLS, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 Sqmm copper conductor multistranded FRLS, PVC insulated (unsheathed) drawn into existing concealed PVC rigid / steel conduit and into existing CI / pressed steel terminal boxes including 3.00mm thick hylam brand IS-2036 marked, laminated sheet cover for mounting switches, sockets, fan regulators etc complete all as specified and as directed. Note: - (a) Wiring shall be done by using proper colour coding. (b) Earth wire shall be of green colour. (c) On RCC roof / ceiling PVC conduit shall be provided on surface with proper fixing clamps all as directed by Engineer-in-Charge.
Description same as per Ser item No 18.00 here-in-before but for one 5 pin socket outlet 5 amps on the same board complete all as specified and as directed.
Description same as per Ser item No 18.00 here-in-before but for one 5 pin socket outlet, 5 amps on independent board complete all as specified and as directed.
Description same as per Ser item No 18.00 here-in-before but for one 5 pin socket outlet 15 Amps on independent board with cables 2.5 Sqmm size complete all as specified and as directed.
Material and labour for point wiring for one light / fan / call bell point controlled by one 5 Amp switch with 1.5 Sqmm single core multistranded copper conductor FRLS, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 Sqmm copper conductor multistranded FRLS, PVC insulated (unsheathed) drawn into and including new concealed PVC rigid / 1.8mm wall thickness ISI marked including new CI / pressed steel terminal boxes including 3.00mm thick hylam brand IS-2036 marked, laminated sheet cover for mounting switches, sockets, fan regulators etc complete all as specified and as directed. Note: - (a) Wiring shall be done by using proper colour coding. (b) Earth wire shall be of green colour. (c) On RCC roof / ceiling PVC conduit shall be provided on surface with proper fixing clamps all as directed by Engineer-in-Charge.
Description same as per Ser item No 22.00 here-in-before but for 5 Amp socket outlet on same board complete all as specified and as directed.
Description same as per Ser item No 22.00 here-in-before but for socket outlet 5 Amps independent board complete all as specified and as directed by Engineer-in-Charge.
Description same as per Ser item No 22.00 here-in-before but for one 6 pin socket outlet 15 Amps on independent board with cables 2.5 Sqmm size complete all as specified and as directed.
Description same as per Ser item No 22.00 here-in-before but drawn through and including new surface conduit PVC rigid non-metallic conduit 20 mm dia for socket outlet 5 amp independent board complete to accomodate the accessories for PVC gang box complete all as specified and as directed.
Description same as per Ser item No 22.00 here-in-before but drawn through and including new surface conduit PVC rigid non-metallic conduit 20 mm dia for socket outlet 15 amp independent board complete to accomodate the accessories for PVC gang box complete all as specified and as directed.
Material and labour for point wiring for one light / fan / call bell point controlled by one 5 Amp switch with 1.5 Sqmm single core multistranded copper conductor FRLS, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 Sqmm copper conductor multistranded FRLS, PVC insulated (unsheathed) drawn into and including new concealed PVC rigid / 1.8mm wall thickness ISI marked including pressed steel with existing colour terminated boxes of modular metal flush boxes of any way i.e. (1 to 8 way as per site requirement) for mounting switches, sockets, fan regulators etc complete all as specified and as directed for the following: - Note: - (a) Suitable module white cover sheets with frame as specified to be provided in replacement to mild steel / galvanised sunken boxes and measured and paid separately as per relevant item. (b) Wiring shall be done by using proper colour coding. (c) Earth wire shall be of green colour. (c) On RCC roof / ceiling PVC conduit shall be provided on surface with proper fixing clamps all as directed by Engineer-in-Charge.
Description same as per Ser item No 28.00 here-in-before but for 5 Amp socket outlet on same board complete all as specified and as directed.
Description same as per Ser item No 28.00 here-in-before but for socket outlet 5 Amps independent board complete all as specified and as directed by Engineer-in-Charge.
Description same as per Ser item No 28.00 here-in-before but for one 6 pin socket outlet 15 Amps on independent board with cables 2.5 Sqmm size complete all as specified and as directed.
Supply and fixing in replacement modular switch 1 way 6 A, 1 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in replacement modular switch 1 way 16 A, 1 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in replacement socket, 6A - 2/3 pin combined 2 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in replacement socket 6A / 16A - 2/3 pin combined 2 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in replacement fan step regulator, 120 W 1 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in replacement modular metal flush box 1/2 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in replacement modular metal flush box 3 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in replacement modular metal flush box 4 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in replacement modular metal flush box 6 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in replacement modular metal flush box 8 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in replacement modular white cover plate with frame 1 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in replacement modular white cover plate with frame 2 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in replacement modular white cover plate with frame 3 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in replacement modular white cover plate with frame 4 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in replacement modular white cover plate with frame 6 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in replacement modular white cover plate with frame 8 module, 240 volts ISI marked complete all as specified and directed.
Material and labour for replacement distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 12 way 240 volts double door complete all as specified and as directed by Engineer-in-Charge. Note: - Distribution board and MCB's should be of same make.
Material and labour for replacement distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 8 way 240 volts double door complete all as specified and as directed by Engineer-in-Charge. Note: - Distribution board and MCB's should be of same make.
Material and labour for replacement distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 4 way 240 volts double door complete all as specified and as directed by Engineer-in-Charge. Note: - Distribution board and MCB's should be of same make.
Supply and fixing in replacement MCCB 4 pole, 415 Volt fixed thermal and fixed magnetic setting of capacity 125 Amps 16 KA complete all as specified and as directed.
Supply and fixing in replacement 240 V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 Amp, in the MCB DB complete with connection, testing and commissioning complete all as specified and as directed.
Supply and fixing in replacement 240 V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 40 Amp, in the MCB DB complete with connection, testing and commissioning complete all as specified and as directed.
Supply and fixing in replacement 240 V, 10 KA 'C' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 32 Amp, in the MCB DB complete with connection, testing and commissioning complete all as specified and as directed.
Supply and fixing in replacement 240 V, 10 KA 'C' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 40 to 63 Amp, in the MCB DB complete with connection, testing and commissioning complete all as specified and as directed.
Supply and fixing in replacement 415 V, 10 KA 'B' curve TPN 40 to 125 Amp miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection, testing and commissioning complete all as specified and as directed.
Supply and fixing in replacement for switch piano, flush type single pole one way 5 Amp, 240 volts complete all as specified and as directed.
Supply and fixing in replacement of switch piano, flush type single pole one way 15 Amps, 240 volts complete all as specified and as directed.
Supply and fixing in replacement socket outlet 2 in 1, 3 pin, 5 A complete all as specified and as directed.
Supply and fixing in replacement socket outlet 5 pin, 15 Amp, flush type, 240 Volts, 6 pin flush type complete all as specified and as directed.
Supply and fixing in replacement switch socket outlet combined 5 pin 5 amp flush type, 240 volts complete all as specified and as directed.
Supply and fixing in replacement switch socket outlet combined 2 in 1, 3 pin 5 amp and 15 amp flush type, 240 volts complete all as specified and as directed.
Supply and fixing in replacement for bell push, flush type single pole, 5 Amp, 240 volts complete all as specified and as directed.
Supply and fixing in replacement ceiling rose 3 terminal surface type complete all as specified and as directed.
Material and labour in replacement for lamp holder, PVC / Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.
Material and labour in replacement self ballast LED retrofit lamp with PVC body and PC Diffuser 9 watt 230 Volt 6500K complete all as specified and as directed.
Supply and fixing in replacement of LED lights fitting with 20 W LED 220 Volts 50 Hz 4 feet long made out of plastic with opal diffuser for glare free and smooth light distribution, 6500 K cool day type conforming to ISI including LED tube light connecting up with two core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
Supply and fixing in replacement LED light fitting mirror type with high output diffuser 2 feet, 9 watt 220 V AC including connecting up with two core flexible copper conductor cable of suitable size complete all as specified and as directed.
Supply and fixing in replacement bulk head luminaries with energy efficient IP-66 rated integrated LED oval bulk head suitable for surface mounting constructed from tough corrosion resistant plastic with black finish with opal diffuser 10 watt, 230 Volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, suitable for roof ceiling including connecting up with driver three core flexible copper conductor of suitable size complete all as specified and as directed.
Supply and fixing in replacement stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as required complete all as specified and as directed.
Supply and fixing in replacement calling bell Ding Dong / buzzer AC 230 Volts, single pole complete all as specified and as directed.
Material and labour in replacement for sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 6 Sqmm for phase and neutral and one run of 4.0 Sqmm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the existing rigid PVC concealed conduit fixed on wall. Two runs of cable for phase / neutral and one run of cable for earth will be measured and paid as one unit length. Note: - Wiring shall be done in proper colour coding.
Material and labour in replacement for sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 4 Sqmm for phase and neutral and one run of 2.5 Sqmm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the existing rigid PVC concealed conduit fixed on wall. Two runs of cable for phase / neutral and one run of cable for earth will be measured and paid as one unit length. Note: - Wiring shall be done in proper colour coding.
Material and labour in replacement for wiring for circuit with proper existing colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 1 run 2.5 Sqmm for phase, drawn through the existing rigid PVC concealed conduit fixed on wall including taking down existing unserviceable wiring complete all as specified and as directed. Note: - Wiring shall be done in proper colour coding.
Material and labour in replacement for wiring for circuit with proper existing colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 1 run 1.5 Sqmm for phase, drawn through the existing rigid PVC concealed conduit fixed on wall including taking down existing unserviceable wiring complete all as specified and as directed. Note: - Wiring shall be done in proper colour coding.
Material and labour for Earthing complete with galvanised mild steel earth plate electrode of size 600 x 600 x 6mm thick buried directly in ground earth (in vertical) earth pit not less than 2.25 metre deep below normal ground level with top edge of the earth plate not less than 1.5 metre below ground level connected to galvanised iron or earth lead wire 4mm dia (8 SWG) by means of nut, bolt, check nuts and washer of galvanised iron including PCC pit in PCC (1:2:4) type B-1 pre-cast RCC cover slab using reinforcement with suitable handle made of round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube for watering with one end fixed with cast iron funnel and wire mesh 15mm dia bore light grade galvanised steel tubing upto 5 m length for drawing earth lead wire protection, common salt, charcoal, etc complete all as shown in electrical plate No 3 of SSR Part-I and testing on completion all as specified and as directed.
Supply and fixing in replacement unserviceable wooden / CI shunken box with new CRCA pressed steel terminal box of size 7 X 4' including taking down old complete with cemented and patch work all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement unserviceable wooden / CI shunken box with new CRCA pressed steel terminal box of size 4 X 4' including taking down old complete with cemented and patch work all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement unserviceable wooden / CI shunken box with new CRCA pressed steel terminal box of size 10 X 8' including taking down old complete with cemented and patch work all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement Bakellite hylum sheet 3 mm thick complete with cutting and making size for fixing switches (06 No's each) of size 8'' X 5'' all as specified and directed.
Supply and fixing in replacement Bakelite hylum sheet 3 mm thick complete with cutting and making size for fixing switches (12 No's each) of size 12'' X 10'' all as specified and directed.
Supply and fixing in replacement Bakelite hylum sheet 3 mm thick complete with cutting and making size for fixing switches (02 No's each) of size 5'' X 5'' all as specified and directed.
Supply and fixing in replacement plug top 15 Amps complete all as specified and directed.
Supply and fixing in replacement of Vertical Distribution Board (TP&N) 4 way double door suitable for and including MCCB 125 Amp 16 KA four pole as incomer and outgoing MCB's and should be IP-43 protected with copper bus bars, neutral links, earthing bar all as specified and directed including taking down old unserviceable DB / MCB any type. Note: - (i) Rate includes MCCB four pole 125 Amp, 16 KA, 415 volts with adjustable thermal settings. (ii) MCB's shall be measured and paid separately. (iii) TPN DB and MCCB should be of same make.
Supply and fixing in replacement PVC box (gang box) surface mounted heavy duty 3 way complete with socket outlet 2 in 1, 6 pin 5 amp 240 volt along with switch piano 5 amp 240 volt complete all as specified and as directed.
Supply and fixing in replacement PVC box (gang box) surface mounted heavy duty 3 way complete with socket outlet 2 in 1, 6 pin 5 amp 240 volt along with switch piano 15 amp 240 volts complete all as specified and as directed.
Notes: - (i) For Serial No 17 to 87 : The contractor has to complete the work assigned for above items within 72 hours failing which recovery @ Rs. 25/- per complaint per day will be charged. (ii) The MES Department is not responsible for the payment of staff hired by contractor for complaint rates for attending the complaints by the Electrician are deemed to be included in the item for repair. Electrician / Helper, as all the items of CA are to be supply and fixed by the contractor. (iii) Proper record (date wise) of complaints received and rectified by the contractor shall be produced for verification at the time of payment of each RAR / Bill. (iv) All the complaint slip, register and connected documents will be provided by the contractor without any extra cost. (v) After any repair the site has to be cleaned and make the surface good.
Labour for repair / servicing of ceiling fan of any capacity complete with strip opening the ceiling fan for repair / washing / varnishing and removing of old lubricating substance from bearing / bush using Kerosine oil, carrying out fresh lubrication using grease and to make the ceiling fan noise free for smooth functioning, including replacement of worn out / unserviceable minor spare parts split pin, fan body bolts, spring washer, fan rod bolt etc and PVC insulated, unsheathed stranded twin twisted copper conductor cable of size 1.5 Sqmm upto 1.0 m long, assembling the repaired ceiling fan in existing position and testing to the entire satisfication of Engineer-in-Charge on site. Notes: - (i) Replacement of spares flexible wire etc / rewinding of ceiling fan / capacitor with clamps shall be measured and paid separately under respective item for material and labour cost. (ii) Burnout winding ceiling fans will be taken out for repair / rewinding.
Description same as per Ser item No. 89.00 here-in-before but for exhaust fan of any type mm sweep complete all as specified and as directed.
Description same as per Ser item No. 89.00 here-in-before but for wall mounting fan of any size / type complete all as specified and as directed. Note: - Burnout winding exhaust fans / Wall fans will be taken out for repair / rewinding.
Rewinding of ceiling fan, of any make / type and size (1200 / 1400 mm sweep) with super enamelled copper wire of appropriate gauge as existing to obtain the specified and satisfactory RPM as per manufacturer's specification, including replacement of all insulation materials, varnishing, heating, drying, assembling of stator / rotor, connection and testing complete all as specified and as directed.
Description same as per Ser item No. 92.00 here-in-before but for exhaust fan of any make / type and size complete all as specified and as directed.
Description same as per Ser item No. 92.00 here-in-before but for wall mounting fan of any make / type and size complete all as specified and as directed.
Labour for remetalling of worn out shaft of fan, cutting, brazing, machining and polishing to make the shaft suitable for fixing of new ball bearing and fixing ball bearing in replacement of bushing system in ceiling fan and assembling the same and testing to the entire satisfaction of Engineer-in-Charge to ensure smooth and noise free operation complete all as specified and as directed. Note: - Bearing shall be measured and paid separately.
Supply and fixing ball bearing of any size and type, suitable for any type / make / size of ceiling fan complete all as specified and as directed.
Description same as per Ser item No. 96.00 here-in-before but for exhaust fan of any type / make and size complete all as specified and as directed.
Description same as per Ser item No. 96.00 here-in-before but for wall mounted fan of any type / make and size complete all as specified and as directed.
Supply and fixing in replacement of capacitor 230 Volt AC 50 Hz, conforming to IS-1709 and rated capacity 2.5 MFD for ceiling fan, exhaust fan and wall mounted fan complete all as specified and as directed.
Supply and fixing in replacement of capacitor 230 Volt AC 50 Hz, conforming to IS-1709 and rated capacity 4.0 MFD for ceiling fan, exhaust fan and wall mounted fan complete all as specified and as directed.
Supply and connection in replacement of PVC insulated, unsheathed multistranded, three core twisted copper flexible cable of size 1.5 Sqmm as required complete all as specified and as directed.
Supply and fixing in replacement of only bush of suitable size for exhaust fan of any type / size as per existing type complete all as specified and as directed.
Description same as per Ser item No. 103.00 here-in-before but suitable for wall mounted fan of any type / size as per existing type complete all as specified and as directed.
Supply and fixing in replacement of PVC connector 4 way 6 Amps with connection screws, nuts complete all as specified and as directed.
Supply and fixing in replacement of PVC clamps with fixing screws for holding capacitor of any type and size complete all as specified and as directed.
Supply and fixing of galvanised iron / mild steel anodized bolts with anodized nuts, spring washers, split pin etc size 50 mm long 10 mm dia half threaded type with split pin hole complete all as specified and as directed.
Supply and fixing in replacement mild steel clamp for down rod of suitable size including gromet / reel type rubber pad with bolts, nuts, split pin and washers suitable for housing ceiling fan complete all as specified and as directed.
Supply and fixing in replacement of ceiling fan down rod 12 mm dia and 30 / 45 cm long complete with mild steel clamp rubber reel, split pin nut bolts etc complete all as specified and as directed.
Supply and fixing in replacement of louver shutter made of mild steel sheet metal 1.2 mm thick for round base and 0.8 mm thick for flaps, comprising of mounting legs frames made of mild steel flat strips of size 25mm x 3mm including heavy duty rust proof passivated bolts of size 50 mm long 8 mm dia to be fixed on wall at ground / first / second floor etc complete with using fastener bolt, drilling, (spray painting) over a coat of primer for exhaust fan upto 400 mm sweep including taking down old one complete all as specified and as directed. Note: - (i) Rates are deemed to be including charges for hiring any type of T&P, Ladder, cutter etc. (ii) Contractor shall be responsible for life cover of staff deployed for fixing of lover shutter.
Cleaning of ceiling fan assembly of any type / size and carrying out two coats of spray painting with first quality synthetic enamelled paint of approved colour, including writing of MES number in black paint all as specified and as directed.
Description same as per Ser item No. 111.00 here-in-before but for exhaust fan upto 450 mm complete all as specified and as directed.
Supply and fixing in replacement PVC canopy set of two pieces for ceiling fans of any size complete all as specified and as directed.
Repair to oscillation moving part of wall mounted fan including replacement of all wornout components, bearing, lubrication and assembling complete all as specified and as directed.
Supply and fixing in replacement of ceiling fan blades set of 3 pieces suitable for 1200 / 1400 mm sweep of white / brown / ivory colors complete all as specified and as directed.
Taking down and strip opening to geyser of any make and capacity 25 / 35 / 50 litres including disconnection of all water pipe connection and taking out water inlet / outlet assembly, removing glass wool, the inner tank, descaling the assembly and tank, detecting the leakage, welding / brazing the defected part, repacking the glass wool and refixing the same after making it functional including replacement of worn out nuts, bolts, washer etc complete all as specified and directed. Note: - Cost of material and labour for providing new items shall be measured under relevant items of sch 'A'.
Material and labour for replacement of water inlet and outlet geyser assembly of existing make as required at site with rubber gasket suitable for geyser of 25 / 35 litres capacity electric driven water storage heater with provision of housing for thermostat assembly, heating element fixing arrangement nuts, bolts and washers etc. complete all as specified and directed.
Material and labour for replacement of water inlet and outlet assembly of existing make as required at site with rubber gasket suitable for geyser of 50 litres capacity electric driven water storage heater with provision of housing for thermostat assembly, heating element fixing arrangement nuts, bolts and washers etc. complete all as specified and directed.
Material and labour for replacement of geyser internal assembly (flanged) comprising complete with heating element and thermostat housing as per site requirement and suitable with the existing assembly suitable to 25 / 50 litres capacity complete all as specified and as directed.
Material and labour for replacement thermostat capillary type switch for electric water heater storage type of capacity 25 / 50 litre, 230 volts of existing make of geyser complete all as specified and as directed.
Material and labour for replacement thermostat, switch electric water heater storage type of capacity 25 / 50 litre, 230 volts of existing make of geyser complete all as specified and as directed.
Material and labour for replacement heating element with triangular base / round base, single phase, 230 volt, capacity 2 KW of existing make complete all as specified and as directed.
Material and labour for replacement heating element with triangular / round base, single phase, 230 volt, capacity 1.5 KW of existing make complete all as specified and as directed.
Material and labour for replacement pressure release valve conforming to relevant IS 15mm bore suitable for fixing with GI pipe / tubing 15mm bore complete all as specified and directed.
Material and labour for replacement of heavy duty PVC connection (For Hot Water) nylon threaded 450mm large (18”) 15mm bore including brass nuts, rubber washers complete on both ends all as specified and as directed.
Material and labour for replacement of heavy duty PVC connection (For cold Water) nylon threaded 450mm large (18”) 15mm bore including brass nuts, rubber washers complete on both ends all as specified and as directed.
Material and labour for replacement of indicator lamps round / rectangular type 230 volt AC suitable for geyser of any capacity including providing electric connections complete all as specified and as directed.
Supply and fixing in replacement of unserviceable Geyser with metal body water heater storage type (Geyser) 25 Litre capacity, confirming to ISI, single phase with working voltage 240 Volts, 50 Hz complete all as specified and directed.
Material and labour for replacement water storage inner tank of stainless steel heavy duty confirming to ISI 25 / 35 litres capacity geyser, with provision for fixing 15mm dia galvanized air release valve all as specified and directed.
Material and labour for replacement water storage inner tank of stainless steel heavy duty confirming to ISI 50 litres capacity geyser, with provision for fixing 15mm dia galvanized air release valve all as specified and directed.
Material and labour for painting of geyser of capacity 25 / 35 / 50 litre complete with superior quality synthetic enamel white paint by spray painting after scrapping old paint and making surface clean all as specified and directed.
Material and labour for replacement non return valve 15 mm dia complete all as specified and directed.
Material and labour for replacement split bottom cover (two pieces) suitable for 25 to 50 litres geysers complete with fixing arrangement etc as required at site complete all as specified and as directed.
Material and labour for replacement rubber gasket heavy duty of water inlet outlet assembly suitable for 25 litres capacity geyser complete all as specified and as directed.
Material and labour for replacement outer shell suitable for 25 / 35 litre geyser made out of GI sheet heavy duly confirming to ISI suitable for existing make of geyser complete factory manufactured painted complete all as specified and as directed.
Material and labour for replacement outer shell suitable for 50 litre geyser made out of GI sheet heavy duly confirming to ISI suitable for existing make of geyser complete factory manufactured painted complete all as specified and as directed.
Supply and fixing in replacement glass wool suitable for each geysers complete all as specified and as directed.
Repair / maintenance / servicing to solar water heater system having a capacity 100 to 500 LPD complete with descaling / cleaning to flat plate collector plate, solar heater water tanks, toughened solar glass panels, welding / breazing to solar tanks, repair / rectification of leakage in inlet / outlet water tubing GI, checking and repair to electric system, repair of water make up tank and make the system functionable after repair / servicing and rectification of the fault complete with and including repacement of minor spare parts complete all as specified and as directed. Note: - Spare shall be measured and paid separately.
Supply only union medium grade 25 mm dia
Supply only union medium grade 20 mm dia
Supply only Rubber hose pipe with MS clamp of suitable size
Supply only Gun metal gate/glove valve 20 mm dia
Supply only Rubber gasket of toughened glass
Supply only Painting to steel structure base frame
Supply only float valve PVC 20 mm dia
Material and labour for replacement of Electrical heating element long threaded type, as per existing 3 KW, ISI marked, single phase suitable for solar water heater complete all as specified and directed.
Material and labour for replacement of thermostat, long body, ISI marked of solar water heater of capacity 100 to 500 LPD complete all as specified and as directed.
Material and labour for replacement of Solar hot water tank with thermal insulation suitable for solar water heater of capacity 100 LPD complete all as specified and as directed.
Material and labour for replacement of Solar hot water tank with thermal insulation suitable for solar water heater of capacity 500 LPD complete all as specified and as directed.
Material and labour for replacement of toughened collector glass of size 1.5 M x 1.0 Mtr complete all as specified and directed confirming to ISI.
Material and labour for fasteners 80-100 mm long for fixing of geyser of capacity upto 50 litres including grouting completed works in wall as per site requirement with the floor complete all as specified and directed.
Supply and fixing in replacement chromium plated CP Bib cock 15 mm dia conforming to ISI complete all as specified and as directed.
Supply and fixing in replacement Gun metal glove / gate valve 15 mm dia internal threaded with iron wheel head conforming to ISI complete all as specified and as directed.
Material and labour for replacement of hot water pipe insulation with glass wool and aluminium cladding 20mm bore including all materials as required and directed by Engineer-in-Charge.
Supply and fixing sheet metal enclosure for MCB DB SPN 240 Volts, 2 way single door without bus bar, enclosure made up of CRCA sheet IP-30 including wooden rectangular board of first quality of suitable size for mounting of DB box complete all as specified and directed by Engineer-in-Charge.
Material and labour in replacement for sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 4 Sqmm for phase and neutral and one run of 2.5 Sqmm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn in but including non metallic rigid PVC concealed conduit of 25 mm dia fixed on wall. Two runs of cable for phase / neutral and one run of cable for earth will be measured and paid as one unit length. Note: - Wiring shall be done in proper colour coding.
Material and labour for replacement of tubing galvanised iron "medium grade" with all fittings laid in floor or trenches including taking out old unserviceable pipe of size 15 mm dia complete all as specified and directed.
NOTE NO 1: - Samples of materials as approved will be kept in GE's sample room. NOTE NO 2: - All fittings and fixtures mentioned above will be fixed to the satisfaction of Engr-in-Charge and GE. NOTE NO 3: - Warranty certificate to the Engineer-in-Charge where ever applicable shall be submitted by the Contractor at the time of fittings.
Prakash Trading Corporation
M/S SALARIA ASSOCIATES
M/s. Aggarwal Engineers
M/s Sahib Construction and engineers
Bidder Name
Prakash Trading Corporation
Sarbat Construction Co
M/s. Aggarwal Engineers
M/s Sahib Construction and engineers
M/S SALARIA ASSOCIATES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .