| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.5 LAccepted-AOC | L1 | Accepted-AOC DUE TO L1 | |
| 2 | L2₹26.2 L+₹69,385 (2.72%)Rejected-Finance | L2 | Rejected-Finance HIGHER RATE | |
| 3 | L3₹26.3 L+₹80,323 (3.15%)Rejected-Finance | L3 | Rejected-Finance HIGHER RATE | |
| 4 | L4₹26.6 L+₹1.2 L (4.57%)Rejected-Finance PLOT NO 17 GF PRATAP NAGAR NEW DELHI 110064 | WEST | DELHI | 110064 | L4 | Rejected-Finance HIGHER RATE | |
| 5 | L5₹27.4 L+₹1.9 L (7.51%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L5 | Rejected-Finance HIGHER RATE |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
20 Apr 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NEW DELHI
GE NEW DELHI, SP MARG NAR ABHM GATE NO 5
REPAIR/ MAINT OF CERTAIN E/M FITTINGS/ FIXTURES AND INTERNAL WIRINGS AT CERTAIN BUILDINGS OF AHQ CAMP LODHI ROAD, NEW ECHS POLYCLINIC LODHI ROAD, NDC, ABHM, TPT UNIT ASC, SANGLI APARTMENTS AND SP MARG UNDER GE NEW DELHI
2024_MES_644139_2
NIT No GE/ND-83/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
GE NEW DELHI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE NEW DELHI
₹90,000
Yes
4 Jun 2024
5 Apr 2024
22 Apr 2024
5 Apr 2024
20 Apr 2024
6 Apr 2024
Amount
Taking down carefully old point wiring (Light / Fan/ Socket/ Bell Point ) with aluminium/ copper conductor cable complete including fittings such as ceiling rose, holders, regulators, bell, switch and socket from existing concealed conduits and making good the disturbed surface of wall/ floor complete to match with the existing surface/finishes complete all as specified and directed.
M&L for point wiring with PVC FRLS insulated unsheathed multi stranded copper conductor of size 1.5 Sqmm 1100 V grade including one run of PVC insulated unsheathed multi stranded copper conductor of size 1.5 sqmm as earth continuity conductor connected to common earth dolly, in existing conduits and its accessories, including replacement of factory made steel boxes suitable for modular switch,sockets or piano type switch socket, including modular plates or hylum sheet of suitable size as per site requirement complete all as specified and directed for the following Note: Cutting & chasing, if required, shall be measured/paid under relevant items.
One light/fan/bell point controlled by one No, one way switch complete all as specified and directed.
One 6 Amp socket outlet point controlled by one No, one way switch on same board complete all as specified and directed.
One 6 Amp socket outlet point controlled by one No, one way switch on independent board complete all as specified and directed.
All as per item No 2.00 above but One 16 Amp socket outlet point controlled by one No, one way switch on independent board with cable of size 2.5 sqmm 1100 Volts including one run of size 2.5 sqmm as earth continuity conductor complete all as specified and directed.
S&F in repair modular switch 1 way 6 Amp, SP, one module 230 volts AC complete all as specified and directed.
S&F in repair modular switch 1 way 16 Amp, SP, one module 230 volts AC complete all as specified and directed.
S&F in repair modular socket out let 2/3 pin combined 6 Amp, 230 volts two module AC complete all as specified and directed.
S&F in repair modular socket out let 2/3 pin combined 6/16 Amp, 230 volts two moduleAC complete all as specified and directed.
S&F in repair modular type electronic fan step regulator 120W, modular type 2 module complete all as specified and directed.
S&F in repair modular bell push switch 6 Amps, one module 230 Volts AC complete all as specified and directed.
S&F in replacement LED Batten light fitting 1x 20 watts, 220 volts AC, 1200mm, with electronic driver complete with driverwith polycarbonate diffuser & thd, 10 % including connecting up with three core twisted flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S&F in replacement sleek LED mirror light with high output diffuser 2 feet, 10 watts, 220 volts AC decorative type complete with driver, holders & including suitable LED lamp including connecting up with three core twisted flexible copper conductor cable of suitable size complete all as specified and directed.
S&F in replacement LED luminaire 595 x 595 x2 mm, (2'x2') 36 watts, 220 volts AC recessed type with high efficiency PMMA diffuser, soft glare free light complete with suitable driver, including suitable LED lamp suitable for POP/Gypsum/roof ceiling including connecting up with three core twisted flexible copper conductor cable of suitable size from ceiling rose including cutting of false ceiling in suitable size & making good the disturbed surface & matching with the existing surface complete all as specified and directed.
S&F in replacement warm/cool white LED light wall/surface mounted with pressure die cast alluminium heat sink & PC diffuser round shape 15 watts, 220 volts AC complete all as specified and directed.
S&F in replacement post top lantern ENDURA SPRING 40 W energy saving, environmental friendly , long life aesthetically designed with good indirect symmetrical light distribution , die cast aluminum landscape IP65 luminaire with IP 65 rating with high power COB LED as light source along with its mounting accessories complete all as specified and directed.
S&F in replacement warm white LED light fitting suitable for mounting on photo frame consisting of 9 watt LED strip warm white 230 volts complete all as specified and directed.
Supply & Fixing in replacement light freedom Bldg security light with house service bracket compressing pressure, die cast housing for better aesthetics , thermal management. Comprises of extruded aluminium housing with pre-wired gear tray with LED’s & drive, heat resistant flat glass suitable gasketed for IP65 protection, fitted with toughened glass with high power LED’s of 40 watt complete all as specified and directed.
M&L of submain wiring with PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLSH type, 1100 volts grade 2 x 10 sqmm complete drawn along with 1x 10 sqmm PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLSH type in existing pvc conduit/casing capping for continuous earth wire and connected to common earth dolly complete including taking out old u/s sub main wiring complete all as specified and directed. Note :- Two run of 10 sqmm copper conductor cable,one run of 10.0 sqmm copper cable shall be measured as one unit length .
M&L of submain wiring with PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLSH type, 1100 volts grade size of cable 2 x 6 sqmm complete along with cable 1x 6 sqmm FRLSH type for continuous earth wire and connected to common earth dolly complete including taking out old u/s sub main wiring complete all as specified and directed. Note :- Two run of 6 sqmm copper conductor cable,one run of 6 sqmm copper cable shall be measured as one unit length.
S&F in repairs of switch piano flush type 6 Amp, SP, one way 230 volts with ISI Marked AC complete all as specified and directed.
S&F in repairs of switch piano flush type 16 Amp, SP, one way 230 volts with ISI Marked AC complete all as specified and directed.
S&F in repairs of piano flush type socket out let 5 pin 6 Amp, 230 volts AC complete all as specified and directed.
S&F in repairs of piano flush type socket out let 6 pin 16 Amp, 230 volts AC complete all as specified and directed.
Supply &fix in repairs of piano type electronic fan regulator suitable for 1200 mm ceiling fan complete all as specified and directed.
Supplying and fixing in repair 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections one twin core standard conductor cable flat or circular size 6.0 Sqmm complete all as specified and directed.
Supply only modular switch 6 amps 250 V ACone way with ISI mark complete all as specified and directed.
Supply only modular switch 16 A SP one way 240 volts complete all as specified and directed.
Supply only modular socket 6 A Multi socket for 2/ 3 pin 240 volts complete all as specified and directed.
Supply only modular socket 15 A Multi socket for 2/ 3 pin 240 volts complete all as specified and directed.
Supply only stranded copper Cable(thimble) lugs of size 10.0 sqmm complete all as specified and directed.
Supply only stranded copper Cable(thimble) lugs of size 6.0 sqmm complete all as specified and directed.
Supply and fixing in repair Modular double USB charger 2 module 2400 ma confirming to IS 13252(Part-1) complete all as specified and directed
S&F in replacement of call bell ding dong type suitable for 230 volts AC complete all as specified and directed.
S&F in repairs of Plug Top 15 Amps, 230volts AC, 3-pin complete all as specified and directed.
S&F in repairs flexible copper conductor twisted twin core PVC insulated cable of size 23/0.0076 complete all as specified and directed.
S&F in replacement of MCCB TPN 100 Amp, 25kA thermal type complete all as specified and directed.
S&F in replacement of MCCB TPN 125 Amp, 25kA thermal type complete all as specified and directed.
S&F in replacement of MCCB TPN 160 Amp, 25kA thermal type complete all as specified and directed.
S&F in replacement of MCCB TPN 200 Amp, 25kA thermal type complete all as specified and directed.
S&F in replacement of MCCB TPN 250 Amp, 25kA thermal type complete all as specified and directed.
S&Fin replacement of MCB SP 5-32 Amp, 10kA complete all as specified and directed.
S&F in replacement of MCB SPN 40-63 Amp, 10kA complete all as specified and directed.
S&F in replacement of MCB TPN 40-100 Amp, 10kA complete all as specified and directed.
S&F in replacement of metal clad AC box complete with MCB 20 Amp, 230 volts AC complete all as specified and directed.
S&F in repair sheet metal enclosure for DBs, SPN double door (IP43), 8 ways with 200 amps rated bus bar suitable for 240 volts, AC, 50 Hz, including connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning complete all as specified and directed.
S&F in repair sheet metal enclosure for DBs, SPN double door (IP43), 12 ways with 200 amps rated bus bar suitable for 240 volts, AC, 50 Hz, including connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning complete all as specified and directed.
Supply and fix Wall Mounted indoor type factory made load line DB s double door made out of CRCA mild steel sheet with insulating material like polyester powder coated surface mounted 8 way VTPN 415 volts IP 43 protection with suitable bus bar neutral link and earth link suitable for 4 pole MCCB of 160 A as incoming and SP/TP mcb of rating 5 to 100 amo as outgoing ncluding taking out old u/s DBs complete all as specified and directed.
Supply and fix Wall Mounted indoor type factory made load line DB s double door made out of CRCA mild steel sheet with insulating material like polyester powder coated surface mounted 12 way VTPN 415 volts IP 43 protection with suitable bus bar neutral link and earth link suitable for 4 pole MCCB of 250 A as incoming and SP mcb of rating 5 to 100 amo as outgoing ncluding taking out old u/s DBs complete all as specified and directed.
S&F ceiling fans complete with blades, down rods, accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) ceiling fan of color white or ( as per site requirment ) complete with all accessories internally pre wired and including connecting up with three core flexible copper conductor cable with suitable size and making arrangement to hanging of fan to ceiling with proper hook nut bolt acomplete all as specified and directed. Note : The old u/s ceiling fan 1200/1400 mm sweep to be depositedin MES store yard in safe custody
M&L for taking down ceiling fan and exhaust fan any sweep complete all as specified and as directed by Engr-in-Charge.
S&F exhaust fan, steel bodyAC single Phase. 230V of size230 mm weep with, blades, and frame and louvers complete all as specified and direced. Note : The old u/s exhaust fan 230 mm sweep to be deposited in MES store yard in safe custody
S&F in repairs of fan capacitor 1.5 Mfd complete all as specified and directed.
S&F in repairs of fan capacitor 2.5 Mfd complete all as specified and directed.
S&F in repairs of Mild steel 'U' clamps with rubber reel, bolts, nuts, washers and safety pin complete all as specified and directed.
M&L for taking down ceiling fan by replacing old unserviceable nut bolts, washers (GI) with new one and Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc.e at its position complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of PVC 3 Modular gang box with Cover plate of suitable module as approved by Engg-in-Charge complete all as specified and directed.
S&F in replacement of PVC 6 Modular gang box with Cover plate of suitable module as approved by Engg-in-Charge complete all as specified and directed.
S&F in replacement FRLSH PVC insulated unsheathed single core stranded copper conductor Cable of size 1.5 sqmm LT 1100 volt grade complete all as specified and directed.
S&F in replacement FRLSH PVC insulated unsheathed single core stranded copper conductor Cable of size 2.5 sqmm LT 1100 volt grade complete all as specified and directed.
S&F in repair FRLSH PVC insulated unsheathed single core stranded copper Cable of size 4.00 sqmm LT 1100 volt grade complete all as specified and directed.
Supply and fixing in replacement ventilation fans AC single phase 230/240 V of size 160 mm sweep (as per sample metal/pvc ) complete all as specified and directed.
Supply and fixing in replacement ventilation fans AC single phase 230/240 V of size 230 mm sweep (as per sample metal/pvc ) complete all as specified and directed.
M & L in repair Earthling complete with galvanised steel earth plate electrode, 600x600x6mm thick, buried directly in ground vertically to depth not less than 1.5 meters below normal ground level, connected to galvanised iron earthing strip 25x4mm by means of bolts, nuts, check nuts including necessary excavation and earth work (in any type of strata ) and washers of galvanised iron or steel, CGI watering pipe 20mm bore light grade with funnel and wire mesh, PCC chamber in cement concrete 1:3:6 type c1, 80mm thick pre-cast RCC 1:2:4, type B-1 cover reinforced earth plate surrounded by alternate layers of packed charcoal, salt oacked which shall not be less than 15cm in all side of earth plate complete all as shown in electrical plate No 3 of MES schedule Part-I. complete all as specified and directed by Engr-in-charge.
M&L in replacement LED inverter based 18 watt light batten fitting complete with accessories made of aluminum housing having minimum system efficiency 100 lm/watt operating at full load at AC supply & minimum 10 watt during battery back up , power fractor is equal to or greater 0.95, CCT 6500K, CRI -80, IP-20, inbuilt Li-ion battery for backup, back up to 4 Hrs for complete tube light (partial back up not allowed), LM-79 & 80 complete all as specified and directed.
S & F in replacement side bed lamp (study lamp) adjustable type consist of 3watt led complete all as specified and directed
S&F in replacement pvc cacing caping of any size complete all as specified and directed.
M & L in replacement heating element of 2.0 KW (Circular) as required at site including rubber washers (ISI marked) etc complete all as specified and directed (As per sample).
M & L in replacement heating element of 2.0 KW (Rectangle) as required at site including rubber washers (ISI marked) etc complete all as specified and directed.
S&F in replacement of storage tank made out of steelr sheet of appropriate thickness and confirming to IS 208 (1974) for 50 litre capacity geysers with collar complete duly tested at required pressure as per IT I of 1986 of steel storage tank complete all as specified and directed.
S&F in replacement of storage tank made out of steelsheet of appropriate thickness and confirming to IS 208 (1974) for 25 litre capacity geysers with collar complete duly tested at required pressure as per IT I of 1986 of steel storage tank complete all as specified and directed.
M&L for replacement of insulating material (Glass wool) for 25/ 50 litre capacity Geysers complete all as specified and directed by Engineer -in - charge.
S&F in replacement base plate assembly 20 SWG heavy duty suitable for 25 litre capacity copper tank geyser with inlet, outlet and thermostat pipe with drain plug and screw for fixing the element including clamps for holding the element with nuts, bolts and safety valves suitable for all type of geysers installed at site complete all as specified and directed (As per sample).
S&F in repair chromium plated copper connection pipe 600mm long with two brass adopters washers and connecting up complete all as specified and directed.
M&L in replacement safety nut for high pressure release complete all as specified and directed (As per sample).
S&F in replacement non return valves 15mm dia and connecting up complete all as specified and directed (ISI marked).as per sample
M&L in replacement top cover for geysers of 25/50 ltrs capacity any make as required at site duly painted with two coats of Synthetic enamel spray paint (first quality) complete all as specified and directed.
S&F in replacement thermostat (ISI Marked) for 25/50 Liters capacity Geyser complete all as specified and directed. Make : Daspass/Theeta/TTE
S&F in replacement indicator lamp (Red & Green) 230 volts suitable for Geyser complete all as specified and directed (as per sample)
Supply and fix in replacement mild steel hole fastner (for fixing of Geyser) 10mm dia, 100mm long including nut and washer complete all as specified and directed.
Supply and fix in repair Rigid non-metallic PVC conduit 20 mm dia including of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc for lan/ telephone circuits complete all as specified and directed. Note : Work includes cutting of chases on wall and making good disturbed surfaces.
J B Electricals
H.B. Traders
M/s Durga Traders
SANJEEV ENTERPRISES
GLIBS CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .