Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹21.0 LAccepted-AOC E 30 RAJIV NAGAR BEGUMPUR NEW DELHI 110086 | NEW DELHI | NEW DELHI | DELHI | 110086 | 1 | Accepted-AOC Acceptance Of Tender | |
| 2 | 2₹27.4 L+₹5.5 L (25.3%)Rejected-Finance | 2 | Rejected-Finance Not L1 | |
| 3 | 3₹28.5 L+₹6.6 L (30.2%)Rejected-Finance | 3 | Rejected-Finance Not L1 | |
| 4 | 4₹32.5 L+₹10.6 L (48.7%)Rejected-Finance NH 17 MAIN ROAD BINAGA BAZAR KARWAR 581307 | KARWAR | UTTARA KANNADA | KARNATAKA | 581307 | 4 | Rejected-Finance Not L1 | |
| 5 | 5₹33.8 L+₹11.9 L (54.7%)Rejected-Finance | 5 | Rejected-Finance Not L1 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
7 Jun 2024, 6:00 pmClosed
CWE LUCKNOW
HQ CWE Lucknow, 229 MG Road, LucknowCantt, Lucknow-226002
REPAIR AND MAINT OF STP PLANTS AT SANJOG CHEETRI VIHAR, NIRBHAY VIHAR, GAUR ENCLAVE, HAVELOCK AND RAJIV SANDHU VIHAR IN THE AREA OF AGE E/M EXT (WS) UNDER GE E/M LUCKNOW
2024_MES_653211_1
CWE/LKO/EM/T-06 OF 2024-2025
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
LUCKNOW
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE E/M LUCKNOW
₹90,000
Yes
2 Sept 2024
10 May 2024
14 Jun 2024
10 May 2024
7 Jun 2024
24 May 2024
10 May 2024 - 24 May 2024
Amount
Attend the day to day sewage complaint related leakage , choke , replacement of any part Gate valve NRV for any size ,type ,capacity and any location rectified the same all as directed by EIC. ( Note : - ( i ) Spare Parts will be measured and paid separately under appropriate items ) (ii) Complaint Should be attend immediately within two hrs & Rectified the same day at the earliest without effecting of service .)
Supply only 15 mm dia bronze gate valve screwed type all as specified and directed by EIC Make :-Zoloto/Kartar/Bir
Supply only 20 mm dia bronze gate valve screwed type all as specified and directed by EIC Make :-Zoloto/Kartar/Bir
Supply only 25 mm dia bronze gate valve screwed type all as specified and directed by EIC Make :-Zoloto/Kartar/Bir
Supply only of Non return valve casr iron 100 mm dia (flanged end) swing type with natural Rubber flap flanges as IS 4038 all as per directed by EIC .
Supplying, laying or fixing, jointing and testing LT underground electric power cable, crossed linked polyethylene (XLPE cable) 10 Sqmm 2 Core, galvanised steel strip or wire armoured, ISI-7098 Marked with aluminium conductor multistranded, heavy duty 1100 volts grade including taking out of old exisiting UG cable of following sizes complete all as specified and laid in trenches/laid under floor or fixed naked with walls/on poles/in ducts/ in GI pipes etc. (Excavation, earth work, sand cushioning, protection bricks/ tiles/block, clamps, nuts, bolts, washers and pipe shall be measured and paid separately under appropriate items) :-
All as per Item No 06 here in before but size 70 Sqmm 3.5 Core
All as per Item No 06 here in before but size 10 Sqmm 4.0 Core
Supply, laying, jointing, testing and commissioning in replacement of Mild Steel pipes of 20 mm dia Medium grade in any length, conforming to IS:1239(I) with flanged ends including fittings (Bend, Elbow, Tee,Rubber gasket, joints etc) fixing on wall/floors including and make header for main collection well, riser for MBBR chamber and painting with two coats of synthetic enamel paint of existing tint/colour complete all as specified and directed by the Engineer-in-Charge, as for the following sizes.Including taking out of u/s pipe
All as per Item No 09 here in before but size 80 mm dia
All as per Item No 09here in before but size 100 mm dia
All as per Item No 09 here in before but size 150 mm dia
All as per Item No 09 here in before but size 200 mm dia
Attend the day to day complaint of non functing part to Air Blower , Air Blower Motor ,non clog submersible Pump, motor and all connected parts and including single phase preventor ,MCCB,Relays,contactors, MCB DB ,Panel Board , DG set ,submersible cable ,Switch socket & other Electrir connected of any size ,type ,capacity and any location rectified the same all as directed by EIC.. ( Note : - ( i ) Spare Parts will be measured and paid separately under appropriate items ) (ii) Complaint Should be attend immediately within two hrs & Rectified the same day at the earliest without effecting of service .)
Supply only Flat type submersible cable PVC insulated and PVC sheathed conductor 10 Sqmm 3 core 1100 Volts grade, flat cable conforming to IS-694:1977 complete with necessary electric connection all as and directed. Make :- Havells/Polycab/Finolex
Supply only Flat type submersible cable PVC insulated and PVC sheathed conductor 6 Sqmm 3 core 1100 Volts grade, flat cable conforming to IS-694:1977 complete with necessary electric connection all as and directed. Make :- Havells/Polycab/Finolex
Supply only thermal overload relay with single phasing protection of range 4.5 to 7.5 Amps all as specified and directed by EIC Make - Siemens /Havell,s/L&T
Supply only thermal overload relay with single phasing protection of range 6 to 10 Amps all as specified and directed by EIC Make - Siemens /Havell,s/L&T
Supply only thermal overload relay with single phasing protection of range 9 to 14 Amps all as specified and directed by EIC Make - Siemens /Havell,s/L&T
Supply only thermal overload relay with single phasing protection of range 14 to 23 Amps all as specified and directed by EIC Make - Siemens /Havell,s/L&T
Supply only power contactor MNX-9 type 3 Phase, 415 Volts with NO & NC Aux contacts, current carrying capacity 9 Amps, coil voltage 220 volts, 50 Hz all as specified and directed by EIC Make - Siemens /Havell,s/L&T.
Supply only power contactor MNX-12 type 3 Phase, 415 Volts with NO & NC Aux contacts, current carrying capacity 12 Amps, coil voltage 220 volts, 50 Hz all as specified and directed by EIC Make - Siemens /Havell,s/L&T.
Supply only power contactor MNX-18 type 3 Phase, 415 Volts with NO & NC Aux contacts, current carrying capacity 18 Amps, coil voltage 220 volts, 50 Hz all as specified and directed by EIC Make - Siemens /Havell,s/L&T.
Supply only power contactor MNX-25 type 3 Phase, 415 Volts with NO & NC Aux contacts, current carrying capacity 25 Amps, coil voltage 220 volts, 50 Hz all as specified and directed by EIC Make - Siemens /Havell,s/L&T.
Supply only MCB TPN 32 Amps, 440V AC 'C' series ISI Marked. Make : Make - Siemens /Havell,s/L&T
Supply only Single Phase preventor testing complete all as specified and directed .Make Minilec
Supply only MCCB 4 Pole, current rating 32-40 Amps, thermal & magnetic setting adjustable 70%-100% breaking capacity 35 kA at 415V,50Hz. Make - Havells/Schneider/L&T
Supply only MCCB 4 Pole, current rating 100 Amps, thermal & magnetic setting adjustable 70%-100% breaking capacity 35kA at 415V,50Hz. Make - Havells/Schneider/L&T
Supply only MCCB 4 Pole, current rating 160 Amps, thermal & magnetic setting adjustable 70%-100% breaking capacity 35 kA at 415V,50Hz. Make - Havells/Schneider/L&T
Supplying and laying in replacement of CPVC pipe of 100 mm dia of sehedule 80 pipes & plain CPVC sehdule 80 fitting and including bend, Elbow, Tee laid in trenches, wall etc complete as directed by CIC.including taking of old/us pipe.
All as per Item No 26 herein before but size of 150 mm dia
Excavation in trenches not exceeding 1.5m deep and not exceeding 1.5m wide and getting out in Soft/Loose soil for laying of pipes/LT cables complete all as specified and directed.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in Soft/Loose soil complete all as specified and directed.
Removing surplus excavated material in soils not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Supply and spread sand for cushioning to UG cable including spreading leveling and hand punning etc complete all as specified in clause 19.75 of SSR Part-I.
M & L Sub class ‘B’ brick laid old size dry flat all as specified directed by Engineer-in-charge.
Cutting the existing road/hard standing not exceeding 300mm width and 300mm deep including removing exavated material to a distance not exceeding 50 Mtrs from starting point all as directed by Engineer - in - Charge
M&L for 1:4:8 D2 Cement concrete in surface channels and drains all as specified and directed by EIC
Supply and fixing in repairs cast iron butterfly valve of 50 mm dai (wafer type) lever operated class PN-1.6, S.S-304 Disc, Nitrile/EPDM rubber lining including making new flanged joint with 3mm thick rubber gasket (Packing ring) with necessary bolt, nuts and washer of suitable size complete all as specified and directed of following size :- Make : Zoloto/Kirloskar/kartar
All as per Item No 39 here in before but size 65 mm dia
All as per Item No 39 here in before but size 80 mm dia
All as per Item No 39 here in before but size 100 mm dia
All as per Item No 39 here in before but size 150 mm dia
Supply & filling in replacement of new Gear Oil Grade G-90 for Air Blower as specified and directed .
General servicing of Kirloskar Make DG set including tappet adjuistment of 82.5 KVA sets including supply and replacement of tappet cover gasket all as specified and directed by the Engr-in-Charge. Note :-Spare parts shall be paid and measured seprately under respective items
Supply and replacement of diesel filter Primery and secondary .
Supply only and replacement of Lub Oil filter
Supply only and replacement of fan belt
General servicing of Kirloskar Make DG set including tappet adjuistment of 30/50 KVA sets including supply and replacement of tappet cover gasket all as specified and directed by the Engr-in-Charge. Note :-Spare parts shall be paid and measured seprately
Supply and replacement of diesel filter ( 34.32 -1200) Primery and secondary .
Supply and replacement of Lub Oil filter
Supply and replacement of Fan belt
Disconnecting of oil chamber and decaning of old lub oil from all sets . Supply and filling the new oil 20W/40W all as per manufacturer's recommendation up to required level all as specified and as directed by the Engr-in-Charge.
Dismantling the coil from alternator of DG set of capacity 82.5 KVA installed at STPs and transporting to civil workshop for repair. strip opening of alternator, taking out burnt copper winding, cleaning the slouts of stator and cleaning the rotor, rewinding the stator field coil with supper enameled copper winding wire of existing size and gauge including provision of new insulating material of class 'E', insullation varnishing, heating etc reassembling the same, bringing back to its original location, connecting and testing complete all as specified and directed.
Dismantling of Dynamo from DG set of capacity 30/50 KVA installed at STPs and transporting to workshop , strip opening taking out burnt winding wire form the stator cleaning the slot and re-winding the same with suitable size of copper winding wire , replacement of worn out diod, bearing and cutout , overhauling & servicing of the Dynamo and tranporting bakc to site and connecting the same with DG set and testing complete all as specified and as directed by the Engr-in-Charge.
Supply of liquid clorine sodium hypochlorite ( Grade - I ) drinking water with 9 % clorine contents by volume confirming to IS-11673 in seald non chemicale re-actined / oxidation LDPE Container of 60 Kg PVC tank with manufacture clorine test certificate and manufacture date mark not more than 02 week ago as required on monthly basis complete all as specified and directed . Make :- M/S Grasim Industris Ltd ( chemical division ) New delhi or other equilent as approved by GE .Note : - The Contractor shall arrange for independent testing for clorine contents from any Govt analysist / CHCC lab / Lan Nigam at own cost and shall be produced along with their claim for Payment .
Supply of Aerobic Bio Culture ,mixing of MBBR chamber for clearity of sewge water all as specified and directed by EIC. (NEC BIO 011)
M&l for supply filling of Filter Media Pebbles & Gravels and carbon filter for filter vessel (2069) in pressure sand filter (PSF) (PSF) Activated carbon filter (ACF) Note;-(i) Spare items such as Gravels,Activted carbon will be measured and paid separately under appropriate items (ii) Rates are including taking down of old material from Pressure sand filter vessels and Activted carbon filter.
Supply only Gravel of size 20-50 mm all as specified and directed by EIC
Supply only Gravel of size 10-20 mm all as specified and directed by EIC
Supply only Gravel of size 2-10 mm all as specified and directed by EIC
Supply only Gravel of size 8-16 mm all as specified and directed by EIC
Supply only Gravel of size 16-32 mm all as specified and directed by EIC
Supply only Activated Carbon 900 IV all as specified and directed by EIC
Supply only Anthracite charcoal all as specified and directed by EIC
Material and Labour for taking out /dismantling of Air blower pump set of rating 3 phase 440 Volts supply of capacity upto 20 HP from STP plant at any location and shifting the same to contractor's workshop for repair and re-installation/refixing the same after repair at its original site and testing complete all as specified and directed by EIC .(Note:-Defective parts,rewinding etc shall be measured and paid separetly under respective supply only items)
Cutting out the existing winding of the motor,strip opening of winding, re-winding of motor with same size and gauge of super enamelled copper winding including tapping, varnishing, with the insulating sleeve and making connection complete all as specified and directed.
Repairing of pump by re-threading of worn out studs holes and supply and fixing over size studs with nut and washer complete all as specified and dierected.
Repairing of pump shaft by metal on it by breazing, grinding and polishing to appropriate size of the shaft complete all as specified and directed.
Supply only oil seal
Supply only driven end bearing No 6809 SKF/NBC of blower shaft complete all as specified and directed.
Supply only end bearing No 6809 SKF/NBC of blower shaft complete all as specified and directed.
Supply only gasket
Supply only coupling with studs between motor & air blower complete all as speicifed and directed.
Supply only suction of air filter of flow rate 1000 meter cubic per hrs complete all as specified and directed.
Supply only of suction silencer complete all as specified and directed.
Supply only bearing No 6809 SKF/NBC of motor shaft complete all as specified and directed.
Supply only V belt of model No B-64 for blower motor as existing size all as specification and directed by EIC Make Fenner
Material and Labour for taking out /dismantling of Air blower pump set of rating 3 phase 440 Volts supply of capacity upto 12.5 HP from STP plant at any location and shifting the same to contractor's workshop for repair and re-installation/refixing the same after repair at its original site and testing complete all as specified and directed by EIC .(Note:-Defective parts,rewinding etc shall be measured and paid separetly under respective supply only items)
Cutting out the existing winding of the motor,strip opening of winding, re-winding of motor with same size and gauge of super enamelled copper winding including tapping, varnishing, with the insulating sleeve and making connection complete all as specified and directed.
Repairing of pump by re-threading of worn out studs holes and supply and fixing over size studs with nut and washer complete all as specified and dierected.
Repairing of pump shaft by metal on it by breazing, grinding and polishing to appropriate size of the shaft complete all as specified and directed.
Supply only oil seal
Supply only driven end bearing No 6309 of blower shaft complete all as specified and directed.
Supply only end bearing No 6309 of blower shaft complete all as specified and directed.
Supply only gasket
Supply only coupling with studs between motor & air blower complete all as speicifed and directed.
Supply only suction of air filter flow rate 1000 meter cubic per hrs complete all as specified and directed.
Supply only of suction silencer complete all as specified and directed.
Supply only bearing No 6309 of motor shaft complete all as specified and directed.
Supply only V belt Model No B-50 for blower motor as existing size all as specification and directed by EIC Make Fenner
Material and Labour for taking out /dismantling of Air blower pump set of rating 3 phase 440 Volts supply of capacity upto 7.5 HP from STP plant at any location and shifting the same to contractor's workshop for repair and re-installation/refixing the same after repair at its original site and testing complete all as specified and directed by EIC .(Note:-Defective parts,rewinding etc shall be measured and paid separetly under respective supply only items)
Cutting out the existing winding of the motor,strip opening of winding, re-winding of motor with same size and gauge of super enamelled copper winding including tapping, varnishing, with the insulating sleeve and making connection complete all as specified and directed.
Repairing of pump by re-threading of worn out studs holes and supply and fixing over size studs with nut and washer complete all as specified and dierected.
Repairing of pump shaft by metal on it by breazing, grinding and polishing to appropriate size of the shaft complete all as specified and directed.
Supply only oil seal
Supply only driven end bearing No 6307 SKF/NBC of blower shaft complete all as specified and directed.
Supply only end bearing 6307 SKF/NBC of blower shaft complete all as specified and directed.
Supply only gasket
Supply only coupling with studs between motor & air blower complete all as speicifed and directed.
Supply only suction of air filter flow rate 1000 meter cubic per hrs complete all as specified and directed.
Supply only of suction silencer complete all as specified and directed.
Supply only bearing of motor shaft complete all as specified and directed.
Supply only V of model No B-52 belt for blower motor as existing size all as specification and directed by EIC Make Fenner
Material and Labour for taking out /dismantling of Air blower pump set of rating 3 phase 440 Volts supply of capacity upto 5.0 HP from STP plant at any location and shifting the same to contractor's workshop for repair and re-installation/refixing the same after repair at its original site and testing complete all as specified and directed by EIC .(Note:-Defective parts,rewinding etc shall be measured and paid separetly under respective supply only items)
Cutting out the existing winding of the motor,strip opening of winding, re-winding of motor with same size and gauge of super enamelled copper winding including tapping, varnishing, with the insulating sleeve and making connection complete all as specified and directed.
Repairing of pump by re-threading of worn out studs holes and supply and fixing over size studs with nut and washer complete all as specified and dierected.
Repairing of pump shaft by metal on it by breazing, grinding and polishing to appropriate size of the shaft complete all as specified and directed.
Supply only oil seal
Supply only driven end bearing No 6206 SKF/NBC of blower shaft complete all as specified and directed.
Supply only end bearing No 6206 SKF/NBC of blower shaft complete all as specified and directed.
Supply only gasket
Supply only coupling with studs between motor & air blower complete all as speicifed and directed.
Supply only suction of air filter complete all as specified and directed.
Supply only of suction silencer complete all as specified and directed.
Supply only bearing of motor shaft complete all as specified and directed.
Supply only V of model No A-42 belt for blower motor as existing size all as specification and directed by EIC
Material and labour for taking out the silt & foreign object , Cleaning & Removing sludge from course bar screen including all chamber of equilasation tank upto depth of 15 Mtr any capacity STP as per direction by EIC .
Material and labour for taking out the silt & foreign object ,Cleaning & Removing sludge from Fine bar screen ,Oil & Grease Chamber with water pressure, bleaching powder etc complete with all as specified & direction by EIC .
Material and labour for taking out the silt & foreign object ,Cleaning & Removing sludge from MBBR I & II Chamber with water pressure, bleaching powder etc complete with all as specified & direction by EIC .
Material and labour for taking out the silt & foreign object ,Cleaning & Removing sludge from Tube Setteler Chamber with water pressure, bleaching powder etc complete with all as specified & direction by EIC .
Taking out outlived MBBR media of sewage treatment plant and supply and fill fresh MBBR media - small cylindrical shaped polyethylene carrier having specific gravity between 0.94 and 0.96 and refilling after cleaning complete material as per existing complete all as directed by Engineer -in - Charge .
Supply and fix in replacement Pac media in tube settler tank as per existing specified size
Supply and fix in replacement of course bubble diffuser as per existing specified size .
Supply and fix in replacement of fine bubble diffuser as per existing specified size .
Replacement of sand filter media of sludge drying bed as per specification laid specification of IS , as per direction by EIC .
M & L for painting of old M S pipe of size 200 mm,150mm,100mm and angles grame of size 200mmx100mmx20mm for complete one STP and applying two coats of epoxy paint with one coat of primer all as specified and directed by EIC Make Asian/Burzer
M & L for painting of old M S pipe of size 80mm ,65mm,50mm,40mm,25mm,20mm for complete one STP and applying two coats of epoxy paint with one coat of primer all as specified and directed by EIC
Supply and fixing in repairs pressure guage analog type suitable for pressure range 0 to 10 Kg/Cm2 complete all as specified and directed by EIC.
Material and Labour for taking out unserviceable/burnt raw sewage pump set lifting from 45 fit depth of capacity upto 10 HP of rating 3 phase 440 Volts supply from raw sewage collection sump of STP plant at any location and shifting the same to authorised workshop for repair and re-installation/Re-fixing/lowering in the sewage sump complete all as specified and directed. Note :-(i) Spare Parts will be measured and paid separately under appropriate items) listed here belwo :-
Cutting out the existing winding of stator of Raw sewage motor of any make and rewinding with water proof copper winding wire of appropriate guage as existing all as specified and directed.
Straightening of the slots of stator of submersible motor of any make.
Supply only thrust bearing block complete of submersible pump of any make.
Supply only gun metal bushes for submersible motor as per manufacturer's design and specification.
Supply only sand guard of submersible motor.
Supply only stainless steel metal impellars
Supply only shaft sleeve
Supply only gasket and O-ring
Supply only Mechanical seal motor end.
Supply only Mechanical seal pump end
Supply only deep groove ball bearing No 6307-08 SKF/NBC of motor side
Supply only groove ball bearing No 6307-08 SKF/NBC of pump side
Supply only shaft protection sleeve
Supply only bowl, cast iron
Supply only bearing sleeve complete
Material and Labour for taking out unserviceable/burnt raw sewage pump set lifting from 35 fit depth of capacity upto 7.5 HP of rating 3 phase 440 Volts supply from raw sewage collection sump of STP plant at any location and shifting the same to authorised workshop for repair and re-installation/Re-fixing/lowering in the sewage sump complete all as specified and directed. Note :-(i) Spare Parts will be measured and paid separately under appropriate items) listed here belwo :-
Cutting out the existing winding of stator of Raw sewage motor of any make and rewinding with water proof copper winding wire of appropriate guage as existing all as specified and directed.
Straightening of the slots of stator of submersible motor of any make.
Supply only thrust bearing block complete of submersible pump of any make.
Supply only gun metal bushes for submersible motor as per manufacturer's design and specification.
Supply only sand guard of submersible motor.
Supply only stainless steel metal impellars
Supply only shaft sleeve
Supply only gasket and O-ring
Supply only Mechanical seal motor end.
Supply only Mechanical seal pump end
Supply only deep groove ball bearing No 6307-08 SKF/NBC motor side
Supply only groove ball bearing 6307-08 SKF/NBC pump side
Supply only shaft protection sleeve
Supply only bowl, cast iron
Supply only bearing sleeve complete
Material and Labour for taking out unserviceable/burnt raw sewage pump set lifting from 45 fit depth of capacity upto 5.5 HP of rating 3 phase 440 Volts supply from raw sewage collection sump of STP plant at any location and shifting the same to authorised workshop for repair and re-installation/Re-fixing/lowering in the sewage sump complete all as specified and directed. Note :-(i) Spare Parts will be measured and paid separately under appropriate items) listed here belwo :-
Cutting out the existing winding of stator of Raw sewage motor of any make and rewinding with water proof copper winding wire of appropriate guage as existing all as specified and directed.
Straightening of the slots of stator of submersible motor of any make.
Supply only thrust bearing block complete of submersible pump of any make.
Supply only gun metal bushes for submersible motor as per manufacturer's design and specification.
Supply only sand guard of submersible motor.
Supply only stainless steel metal impellars
Supply only shaft sleeve
Supply only gasket and O-ring
Supply only Mechanical seal motor end.
Supply only Mechanical seal pump end
Supply only deep groove ball bearing 6206-07 SKF/NBC of motor side
Supply only groove ball bearing 6306-07 SKF/NBC of pump side
Supply only shaft protection sleeve
Supply only bowl, cast iron
Supply only bearing sleeve complete
Material and Labour for taking out unserviceable/burnt raw sewage pump set lifting from 35 fit depth of capacity upto 2.0 HP of rating 3 phase 440 Volts supply from raw sewage collection sump of STP plant at any location and shifting the same to authorised workshop for repair and re-installation/Re-fixing/lowering in the sewage sump complete all as specified and directed. Note :-(i) Spare Parts will be measured and paid separately under appropriate items) listed here belwo :-
Cutting out the existing winding of stator of Raw sewage motor of any make and rewinding with water proof copper winding wire of appropriate guage as existing all as specified and directed.
Straightening of the slots of stator of submersible motor of any make.
Supply only thrust bearing block complete of submersible pump of any make.
Supply only gun metal bushes for submersible motor as per manufacturer's design and specification.
Supply only sand guard of submersible motor.
Supply only stainless steel metal impellars
Supply only shaft sleeve
Supply only gasket and O-ring
Supply only Mechanical seal motor end.
Supply only Mechanical seal pump end
Supply only deep groove ball bearing 6205-06 SKF/NBC of motor side
Supply only groove ball bearing 6305-06 SKF/NBC of pump side
Supply only shaft protection sleeve
Supply only bowl, cast iron
Supply only bearing sleeve complete
Material and Labour for taking out unserviceable/burnt submersible pump set of capacity 10 HP of rating 3 phase 440 Volts supply from Sanjog chetri vihar treated water sump and shifting the same to authorised workshop for repair and re-installation/Re-fixing/lowering in the sewage sump complete all as specified and directed. Note :-(i) Spare Parts will be measured and paid separately under appropriate items) listed here belwo :-
Cutting out the existing winding of stator of Raw sewage motor of any make and rewinding with water proof copper winding wire of appropriate guage as existing all as specified and directed.
Straightening of the slots of stator of submersible motor of any make.
Supply only thrust bearing block complete of submersible pump of any make.
Renewal of wornout gun metal bushes for submersible motor as per manufacturer's design and specification.
Supply only sand guard of submersible motor
Supply only sleeeve of end plates of submersible motor
Supply only cable grommet (guard)
Supply only water seal
Supply only studs with nuts of required length & dia
R-metaling of pump shaft, turning to bring it to original size and complete and ploshing of shaft of submersible motor complete
Supply only coupling of submersible & pump with key motor complete
Jointing of 3 core cable of any size by using puncture/rubber compound roll & tape/sealing compound complete
Complete removal of old painted surface of motor and pump set and applying two coat of syntyhetic enamel paint(1st quality) over a coat of metal primer (hammer tone finish) all as specified. Note:- Painting shall be done by sapry machine
Provision for Bactroligical test and sample collection from Four STP plant in sterlized bottle by Govt Recognize Lab ,monthly periodically as per the enviroment ( Protection ) Rull Sch II ( Rule 3 ) 1986 , in permission standard in Sewage Treated Water for inland surface water i.e , complete all as specified and directed by Engineer-in -Charge. Contractor has to maintain the quality of water as below mentioned parameters: (a) Total suspended solid Max < 10 mg / Ltrs . (b)Total dissolved Solids- As per IS3025(Part16)-2023 (c) PH value (6.5 to 8.5 PH ) (d) Biochemical oxygen Demand ( 3 days at 20 ^ degree cetigrate ) Max < 10 (e) Phosphorus as P <5 MG/L (f) Nitrate as N <10 MG/L (g) Focal Coliform in MPN 230/100 ML NOTE:- Testing report for 01 no of STP for Raw sewage and after treatment water monthly wise on last week of each month will be included in quotaed rate .
Provision for Bactroligical test and sample collection from Four STP plant in sterlized bottle by Govt Recognize Lab ,monthly periodically as per the enviroment ( Protection ) Rull Sch II ( Rule 3 ) 1986 , in permission standard in Sewage Treated Water for inland surface water i.e , complete all as specified and directed by Engineer-in -Charge. Contractor has to maintain the quality of water as below mentioned parameters: (a) Total suspended solid Max < 30 mg / Ltrs . (b)Total dissolved Solids- As per IS3025(Part16)-2023 (c) PH value (5.5 to 9.0 PH ) (d) Biochemical oxygen Demand ( 3 days at 27 ^ degree cetigrate ) Max < 30 (e) COD ( Chemical Oxygen Demand ) <250.As (f) Total coliform in MPN as per IS -1622:1981 (g) Focal Coliform in MPN as per IS -1622:1981. NOTE:- Testing report for 04 no of STP for Raw sewage and after treatment water monthly wise on last week of each month will be included in quotaed rate .
Dismantling of old any type bldg security light fittng and S&F Building security light fittings 20W LED 6500k, pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP65 protection and impact resistance of IK0 with IP 65 protection including suitable size of GI Pipe made to shape and fixing to the wall, with the use of nut and bolts, making connections from ceiling rose. CMake:Havells or equiv in wipro/Philips.
Supply and fixing in replacement of LED street light fitting 50 Watt 6500 K 230 V AC outdoor type with high pressure diecast aluminum hosing and heat resistant complete with driver, lamp bracket with impactand corrosion resistant including thermalmanagement in multiple optics complete withIP 65/66 protection complete. incuding taking down of old light fitting, complete all as specified and directed. Make- Philips/Crompton/Havells/Bajaj/Wipro
Material and labour for spray painting of DG Set of capacity 82.5 KVA and electrical LT panel after prepartion of surfaces apply two coat of synthetic enamelled paint with and including marking of SM/MES No. of existing size complete all as specified and directed.
Material and labour for spray painting of DG Set of capacity 30/50 KVA and electrical LT panel after prepartion of surfaces apply two coat of synthetic enamelled paint with and including marking of SM/MES No. of existing size complete all as specified and directed.
M&L for Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level, including provision of GI earth strip 32x6 mm as earthing lead connected by means of bolts, nuts, check nuts and washers of galvanized iron or steel, provision of 40 mm dia GI pipe light grade for GI strip protection connected from earth plate electrode to main switch board, provision of 20mm dia GI pipe medium grade for watering arrangement and PCC 1:3:6 type C2 chamber, MS funnel, wire gauge, 50mm thick RCC 1:2:4 type B1 for earth pit cover with 6 Nos x 8 mm dia high strength deformed steel TMT bars on both ways, including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to a distance n.exc. 50m, provision of charcoal and salt complete all as shown in electrical plate No.3 of Schedule Part-I 2009 all as specified and as directed and testing on completion.
M & L for painting of street light pole of 9 mtr long and applying two coats of enamel paint with one coat of primer all as specified and directed by EIC
Surface dressing & cleaning away all grass vegetation saplings, shrubs, brushwwod, under rrowth root and trees not exc. 30 cm girth(measures 1 mtr above from GL) and removing rubbish upto a distance 50 mtr outside from the premiss area under clearance except in case of surface dressing which includes for all the foregoing except clearing away of tree complete all as specified and directed.
Disconnecting mechanical and electrical connection and taking down Filter feed monoblock pumps (coupled with 3 phase 7.5 HP motor 2900 Rpm) flow - 91 cum/hr, 28m head, type - KDS830+, S&D 80x65 mm from the existing foundation. Repair the unserviceable pump by insertion of graphite packing, rubber gasket and stud etc/ and replacement of unserviceable spares. Reassembling and fixing to its original position, making mechanical and electrical connections and testing pumping set complete all as specified and directed by Engineer-in-Charge. Note for repair of Plant and Machinery : (a) The cost of "To and from" transportation of pump, motor and other plant etc from installation to workshop for repair shall deemed to be included in quoted rate. (b) Cost of grease shall deemed to be included in quoted rate. (c) Spares will be measured and paid for separately under respective items
Supply only bronze shaft sleeve DE/NDE suitable for pumps Model No. KDS1331+, S&D 80x65 mm all as specified and directed by Engineer-in-Charge. Make : Kirloskar
Supply only cast iron impeller suitable for pumps Model No. KDS830+, S&D S&D 80x65 mm all as specified and directed by Engineer-in-Charge. Make : Kirloskar
Supply only ball bearing DE/NDE suitable for pumps Model NO. -KDS830+, S&DS&D 80x65 mm all as specified and directed by Engineer-in-Charge. Make : Kirloskar
Cutting out the existing winding of stator of monoblock motor of any make and rewinding with water proof copper winding wire of appropriate guage as existing all as specified and directed.
OM NAMAH SHIVAY ENTERPRISES
m/s pal associates
ANKIT SHIP REPAIRERS AND SUPPLIERS
M/s Acme Engineers and Contractors
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .