| 1 | L1₹35.0 LAccepted-AOC RATNA RAJ BUILDING 1ST FLOOR 262 BIDHAN ROAD OPP TERA HOTEL PO SILIGURI 734001 DIST DARJEELING WB | JALPAIGURI | WEST BENGAL | 734001 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹40.4 L+₹4.2 L (11.7%)Rejected-Finance | L2 | Rejected-Finance Unsuccessful bidder | |
| 3 | L3₹40.9 L+₹4.8 L (13.3%)Rejected-Finance C O KALIPADA MITRA SOUTH BHARAT NAGAR NEAR JAGDISH CHANDRA HIGH SCHOOL SILIGURI DISTT DARJEELING WB 734004 | JALPAIGURI | WEST BENGAL | 734004 | L3 | Rejected-Finance Unsuccessful bidder | |
| 4 | L4₹41.8 L+₹5.7 L (15.8%)Rejected-Finance 16 APC SARANI WARD NO 30 DESHBANDHUPARA PO SILIGURI TOWN DIST DARJEELING PIN 734004 WB | SILIGURI | DARJEELING | WEST BENGAL | 734004 | L4 | Rejected-Finance Unsuccessful bidder | |
| 5 | L5₹41.8 L+₹5.7 L (15.9%)Rejected-Finance MAKARDHA PO MAKARDHA PS DOMJUR BANERJEEPARA WEST BENGAL 711409 | HOWRAH | WEST BENGAL | 711409 | L5 | Rejected-Finance Unsuccessful bidder |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
13 Dec 2021, 6:00 pmClosed
GE AF Bagdogra
GE AF Bagdogra Bagdogra Airport PO, Dist Darjeeling, WB - 734421
REPAIR AND MAINTENANCE OF ELECTRIC PANEL, LT PANEL AND CONNECTED WORKS AT 20 WING, 273 SU AND 46 WEU AF STATION UNDER GE (AF) BAGDOGRA
2021_MES_489885_1
8413/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF Bagdogra
As per NIT
8 documents required · 8 mandatory
₹500
GE AF Bagdogra
₹70,000
Yes
7 Jan 2022
23 Nov 2021
15 Dec 2021
23 Nov 2021
13 Dec 2021
7 Dec 2021
Amount
M&L for repairs to LT panel boards complete with necessary welding works to doors, replacement of unserviceable hinges and all drop bolt, dismantling all cables, replacing insulation sleeves of busbar as per colour code, replacing cable lugs connecting using new bolts, nut, bolts & washers and replacing damaged cable glands complete including painting of all indoor and outdoor panels with two coat of synthetic enamel paint of approved colour internally and externally all as specified and as directed.
Trimming of tree branches touching to the LT/HT over head line or near to the LT/HT over head line or 2 Pole /4 Pole structure as per the direction of AGE E/M complete incl removing the tree branches from site complete all as specified and directed. Note :- (a) Necessary written shut down to be obtained from AGE (E/M). (b) Span from one pole to next pole (30 to 50 RM) will be considered as a one Job. (c) Any damage caused due to contractor men will be rectified without any extra payment. (d) T&P such as ladder, rope, cutter, Axes and other related material for safety of Manpower will be provided by the contractor within the quoted rate.
M&L for painting all type/size of panel boards all indoor and outdoor with two coat of synthetic enamel paint of approved colour and make internally and externally all as specified and directed and specified.
M&L for preparation of surfaces for LT pole painting by scrapping damaged paint and painting with two coats of silver aluminium paint and writing pole No with black paint on yellow circuit all as directed and specified.
S & F in replacement of Offload Changeover Switch in sheet enclosure, 415 Volt, 50 Hz , 200 Amps, 4 pole with side handle with all accessories. Make: Indoasian Cat No. OFFPO200 or equivalent make of Havells/Legrand/ HPL as approved
S & F in replacement of Offload Changeover Switch in sheet enclosure, 415 Volt, 50 Hz , 315 Amps, 4 pole with side handle with all accessories. Make: Indoasian Cat No. OFFPO315 or equivalent make of Havells/Legrand/ HPL as approved.
Supply, fixing, connecting and testing in replacement Automatic Transfer switch (ATS) Four Pole, Automatic / manual operation type, 315 Amps, Four Pole, 50 Hz, 415V with controller inbuilt time delay and complete protection for open execution type. Make : Havells Cat Part No. IHYFCDO315 or equivalent of L&T/ Legrand.
Supply, fixing, connecting and testing in replacement Automatic Transfer switch (ATS) Four Pole, Automatic / manual operation type, 200 Amps, Four Pole, 50 Hz, 415V with controller inbuilt time delay and complete protection for open execution type. Make : Havells Cat No :IHYFNAO200 or equivalent in L&T/Siemens.
Supply, fixing, connecting and testing in replacement Automatic Transfer switch (ATS) Four Pole, Automatic / manual operation type, 100 Amps, Four Pole, 50 Hz, 415V with controller inbuilt time delay and complete protection for open execution type. Make : Havells Cat No :IHYFNAO100 or equivalent in L&T/Siemens.
Dismantling steel poles/struts, any type and size including opening of ACSR conductors, security/street light fittings, brackets, clamps, stay clamps etc and refixing to new pole etc and including necessary excavation and earth work and transportation etc complete as per site requirement and as specified and directed.
Supply, install and erect in true vertical steel tubular swaged pole complete with MS Box plate 6 mm thick of size 300 x 300 mm finial taper plug, cap, bolt, nuts washers & screws as specified type 410-SP-31 (9 mtr long) Made out of ERW MS tubing confirming to IS-2713 Part II including drilling holes of required size for fixing cables etc painting with two coat of aluminium paint over a coat of red oxide primer for exposed surface and two coat of black bituminous paint for the portion embedded in concrete complete all as specified and as directed.
Demolition of PCC of any description above/below ground level exceeding 15cm complete all as specified and directed
M&L for PCC 1:4:8 type D2 using 40mm graded aggregate for pole / struts foundation etc all as specified and directed.
M&L for PCC 1:3:6 type C1 using 20mm graded aggregate for coping of pole including necessary form work and fair finishing of exposed surface of concrete all as specified and directed.
Dismantling of cross arms, MS Channel or angle Chain link fencing section etc complete including dismantling of nut, bolts and washers all as specified and directed.
Supply and fix cross arms. Bracings, support channel, backpate hooks etc fabricated from structural steel, sections (MS Channel) of required size and shape including nuts, bolts,washers, welding, bending , cutting cold or hot, drilling holes for inserting bolts as indicated and directed including painting with one coat of red oxide primer and two coats of silver aluminium paint complete all as specified and directed.
Dismantling fencing of wire mesh any type fixed to RCC/angle iron posts complete all as specified and directed.
Supply only Chain link MS galvanised fencing of any size and type of weight not more than 4.0 Kgs/Sqm etc all as per site requirement and as directed and specified.
Fixing only chain link fencing including line wires, any mesh, size and type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and as directed.
Supply only Steel round bar upto 10 mm dia and over for tying chain link fencing etc all as specified and directed.
S&F screw bolts (machine made) with hexagonal or square head at one end and rounded the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 5 cm but n.exc 10 cm and dia of shank 11 to 15mm and fixed in position complete all as specified and directed.
M&L for angle iron posts upto size of 50 x 50 x 6mm for chain link fencing, with holes drilled and grouting in the foundation concrete all as directed (Fe 410W) Quality A complete all as specified and directed. Note :- Concrete for foundation measured and paid separately under relevant item.
Supply and fixing Aluminium bus bar of adequate capacity and size as per requirement at site complete including colour coding sleeves all as per specified and directed.
Supply and fixing in replacement 4 pole power contactors 40 Amp, conforms to IS/IEC 60947-4-1 and IEC 69947-4-1, Aux contact 2 NO + 2 NC in existing Panel/Feeder Pillar box complete all as specified and directed. Make: - L&T, Model : MCX-04, Cat No. CS97012 or equivalent in C&S/ Havells/Siemens as approved.
All as per item No 24 here-in-after but 4 pole power contactors 50 Amps. Make: - L&T, Model : MCX-11, Cat No. CS97013 or equivalent in C&S/ Havells/Siemens as approved.
All as per item No 24 here-in-after but 4 pole power contactors 63 Amps. Make: - L&T, Model : MCX-12, Cat No. CS97014 or equivalent in C&S/ Havells/Siemens as approved.
All as per item No 24 here-in-after but 4 pole power contactors 130 Amps. Make: - L&T, Model : MCX-23, Cat No. CS97018 or equivalent in C&S/ Havells/Siemens as approved.
All as per item No 24 here-in-after but 4 pole power contactors 160 Amps. Make: - L&T, Model : MCX-32, Cat No. CS97020 or equivalent in C&S/ Havells/Siemens as approved.
All as per item No 24 here-in-after but 4 pole power contactors 200 Amps. Make: - L&T, Model : MCX-33, Cat No. CS97021 or equivalent in C&S/ Havells/Siemens as approved.
All as per item No 24 here-in-after but 4 pole power contactors 360 Amps. Make: - L&T, Model : MCX-42, Cat No. CS97024 or equivalent in C&S/ Havells/Siemens as approved.
S&F in repairs Three Phase Digital type Voltmeter 0-500 volt, of size 96 x 96mm complete with necessary fixing all as specified and as directed. Make - L&T/ AE/ Siemens / HPL
S&F in repairs Ammeter 3 Phase, 0-250 amps, Digital type, with CT operated of size 96 x 96mmcomplete with necessary fixing all as specified and as directed Make - L&T/Siemens / HPL
Supply and fixing in repairs indicator lamp (Red, Yellow, Blue) complete with necessary fixing all as specified and as directed by Engineer-in-Charge. Make - L&T/Siemens / HPL /Legrand.
Supply and fixing of On load change over switch I-O-II, 415 Volts, 4 pole phase barriers and handle with door interlocking kit of capacity 125 Amps. Make : Havells/Siemens /Havells / HPL
Supply and fixing of On load change over switch I-O-II, 415 Volts, 4 pole phase barriers and handle with door interlocking kit of capacity 200 Amps. Make : Havells/Siemens /Havells / HPL
S & F in replacement of PVC weather proof, hinged door, junction box with, 240V, Neutral link, three phase connector, with IP 66/67 protection suitable for outdoor installation on pole/wall surface and including with 1No MCB SP of 6 Amps, necessary fixing arrangement such as clamps, nut, bolts, etc including dismantling old unserviceable junction box all as directed and specified. Make : Sintex Cat Part No. GSMB 2520, Hensel Cat Part No KF 2500H or equivalent of ISI Mark as approved
M&L for taking out old unserviceable MCCB TP/TPN /FP from existing LT panel board and supply and fix MCCB TPN/4P, adjustable thermal and fixed magnetic type, 400 amps of rup cap capacity 50 KA at 415 volts, 50 Hz AC supply including necessary modification in panel board for fixing the MCCB with replacement of incoming and out going cable connection with providing thimbles/ lugs, aluminium conductor cable of suitable size, nuts bolts and wire/cable pieces etc all as required at site and directed.
All as per Item No 40 above here-in-after but MCCB TP/TPN /FP 200 amps of rup capacity 35 / 36 KA, 415 Volts.
All as per Item No 40 above here-in-after but MCCB TP/TPN /FP 160 amps of rup cap 25 to 27 KA at 415 volts.
All as per Item No 40 above here-in-after but MCCB TP/TPN /FP 100 amps of rup capacity 25 to 27 KA, 415 Volts.
All as per Item No 40 above here-in-after but MCCB TP/TPN /FP 63 amps of rup capacity 25 to 27 KA, 415 Volts.
M&L for repair to street light timers panel by replacing unserviceable parts and testing complete after repairing all as specified and directed. Note :- Replacement of small pieces of wires and lugs/thimbles to done by the contractor under quoted rate and other spares as required will be measured and paid separately.
Supply only for Digital type timer switch,110 - 240 VAC 1 changeover (1 C/O) Base/ DIN 25 mounting suitable for manual and auto on /off both type operation, with (1 CO), Total 28 programs. Make:- L&T, Model : Crono, Cat No. 67DDT0 or equivalent in Siemens/Indoasian.
Supply only for Power contractor 3 pole/4 pole, 22 / 32 amps, suitable for 2NO/2NC power contacts and of coil voltage 24V/48V, VDC/VAC and suitable for street light timer panel as per site requirement and as directed. Make:- L&T, MNX 22, Model No CS94980/CS94981 or equivalent in Siemens/Indoasian.
Supply only for Power contractor 3 pole/4 pole, 40 / 55 amps, suitable for 2NO/2NC power contacts and of coil voltage 24V/48V, VDC/VAC any type and suitable for street light timer panel as per site requirement all as specified and directed. Make:- L&T, MNX 32, Model No CS94190 or equivalent in Siemens/Indoasian.
Supply only for Aux. Contact Block, 2NO/2NC front mounting suitable for power contactor of street light timer panel as per site requirement all as specified and directed. Make:- L&T, Model No. Model No. CS94114/CS94596 or equivalent in Siemens/Indoasian.
M&L for Cutting end and reconnecting of PVC/XLPE LT cable with providing new aluminium terminals (thimbles / lugs) including tapes etc for cable size 25 sqmm 3.5 core complete all as specified and directed. Note :- Replacement of terminals for all three phase and neutral cable ends to be measured a one job.
All as per item No. 50 above here-in-after but for cable size 35 sqmm 3.5 core.
All as per item No. 50 above here-in-after but for cable size 50 sqmm 3.5 core.
All as per item No. 50 above here-in-after but for cable size 70 sqmm 3.5 core.
All as per item No. 50 above here-in-after but for cable size 95 sqmm 3.5 core.
All as per item No. 50 above here-in-after but for cable size 120 sqmm 3.5 core.
All as per item No. 50 above here-in-after but for cable size 150 sqmm 3.5 core.
Material & Labour for LT straight through, heat shrink type Cable jointing kit suitable for 3.5/ 4 core XLPE armoured aluminium conductor cable of size upto 16 sqmm 4 Core complete all as per site requirement all specified and as directed.
All as per item No. 57 above here-in-after but for cable size 25 to 50 sqmm complete .
All as per item No. 57 above here-in-after but for cable size 70 to 120 sqmm complete .
All as per item No. 57 above here-in-after but for cable size 150 to 185 sqmm complete .
Supply and fixing in repairs for distribution board/Panel, 40A, 3 /4 Pole/230V-Digital Time Switch type and including digital timer switch (DIN Type Daily / Programmable every 1 min., with backup of Weekly with 1 CO , current capacity 16A, weekly program, with (1 CO), for street light control panel by replacing old unserviceable street panel and testing complete all as specified and directed. Make : Indoasian/L&T/Siemens or equivalent as approved. Note :- Removal of existing cable, connections safely before removing u/s panel & reconnection all at site as directed to be done by the contractor within the quoted rate.
M&L for repair to Automatic Power Factor Correction (APFC) Panel of capacity from 35KVAr to 200KVAr by replacing unserviceable parts and testing complete after repairing all as specified and directed. Note :- Small pieces of multistranded copper wires upto 10 Sqmm, Single Core and lugs/thimbles as per site requirement to be replaced in repairs by the contractor under quoted rate and other spares as required will be measured and paid separately.
Supply only Standard Duty Capacitors Cylindrical type suitable for APFC Panel of 5 KVA rating, 440V for AFPC Panel as per site requirement and as directed. Make L&T/Havells/ Siemens as approved
All as per item No. 63 above here-in-after but of 10 KVA rating, 440V for AFPC Panel .
All as per item No. 63 above here-in-after but of 20 KVA rating, 440V for AFPC Panel .
All as per item No. 63 above here-in-after but of 25 KVA rating, 440V for AFPC Panel .
Supply only APFC Controller - 1 CT input, upto 6 steps of size 96 x 96mm, Single CT input 1/5 Amps and Voltage Input 415V for AFPC Panel as per site requirement and as directed. Make : L&T/Havells/ Siemens as approved.
Supply only 3 Pole Power Contactors, MNX type, Aux. Contacts 1 NO and 1 NC of rating 32 Amps, for AFPC Panel as per site requirement all as specified and directed. Make : L&T, Model : MNX 22 or equivalent in Havells/ Siemens/Indoasian.
Supply only MCB TPN 'C' Series upto capacity of 32 Amps as per site requirement all as specified and directed. Make : L&T or equivalent in Havells/ Siemens/Indoasian.
M&L for taking out old unserviceable ACB (Air Circuit Breaker) 4 Pole, 415 V, with Thermal Magnetic Release (Manual Draw out type) of capacity 630Amps AC supply including necessary modification in panel board if required to fix the ACB complete with replacement of incoming and out going cable connection with lugs, aluminium conductor cable of proper size, nuts bolts all as directed and specified. Note : Replacement of brunt lugs and wire/cable pieces etc as required at site.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for taking out pipe line etc for repairs / laying cables etc and getting out in soft / loose soil complete all as specified and as directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed.
Removal of excavated material [soil] to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Material and labour for clean dry sand in trenches/ducts for cushioning to cable complete all as specified. Note : Punned thickness shall be measured.
Supplying and laying Bricks; common burnt clay building bricks, sub-class ‘B’ designation 75 complete all as specified and directed.
Supply, fixing and laying in trenches after removing old cable and fixing or passing through pipe, 1100 Volts grade heavy duty LT UG cable, 120 Sqmm, 3.5 Core with XLPE insulated stranded Aluminium conductor served with an inner sheathing of PVC tape, Armoured with galvanised steel wire and overall sheathed including cable gland, lugs, jointing material etc, jointing, connecting, testing and commissioning all as specified and directed.
All as per Ser item No 76 above here-in-before but 95 Sqmm, 3.5 Core
All as per Ser item No 76 above here-in-before but 70 Sqmm, 3.5 Core
All as per Ser item No 76 above here-in-before but 50 Sqmm, 3.5 Core
All as per Ser item No 76 above here-in-before but 35 Sqmm, 3.5 Core
All as per Ser item No 76 above here-in-before but 16 Sqmm, 4 Core
Supply and laying in replacement of Tubes, 'light grade', galvanised iron, 50 mm dia laid in trenches for cable protection at road crossing etc including necessary making good or fixing on wall / poles of any type, secured with clamps and required boring under road or hard surfaces complete with all fittings laid in trenches all as specified and as directed.
Supply, installation, testing and commissioning in renewal of outdoor type cubical Busbar panel board/ feeder pillar suitable for 3 phase 4 wire 415 Volt, 50 Hz and type tested at CPRI at 415 Volt factory fabricated in an approved factory having modern fabrication process powder coated in approved shard having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS 8623793 comprising of the following :- (a) OUTER SHELL. The outer shell shall be made out of 3.15mm thick CRCA Sheet and MS angle section 50x50x6mm frame, factory fabricated with front and back openable double door system lockable / openable by keys from both side having chromium plated 19 mm dia fancy lock, louvers and air vent gasket for natural flow of air. The bottom of the outer shell contains a detachable plate having provn for entry of armoured cable of adequate size with glands. The dimension of the shell should be adequate to accommodate inner shell described below giving minimum 75 mm space all round. Provision o threaded earthing stud at bottom & lifting lugs of suitable size at top to lift the panel safely shall be made. The degree of protection of outer shell shall be IP-54. (b) INNER SHELL. Inner shell shall be made out of 2 mm thick CRCA sheet duly compartmentalized for each control gears, front & back openable single door system by keys. To accommodate TPN Aluminium busbar of rating not less than 200Amps. The busbars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size 'F' class insulators. The degree of protection for inner shell shall be IP-42 & carry the following items :-(i) Incoming/Out going :- TPN Bus bar of capacity not less then 200 Amps complete. (ii) Indication lamp 22.5 mm dia LED type, 240 Volts AC at the incomer of the unit to show 3 phase availability. MAKE : ABB/BCH/L&T/SIEMENS/GE/HAVELLS/C&S/MINILEC or CPRI approved). Note (For Item Nos. 84 to 86) :- (i) Safely Removal of existing cable, connections before removing unsv panel and reconnection of all at site as directed to be done by the contractor within the quoted rate. (ii) Approval of Drawing for the panels to be ascertained from GE/Engr-in-Charge before ordering to manufacturer by the contractor.
M & L in replacement Earthing complete with galvanized steel earth plate electrode 60cm X 60cm X 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level connecting to the GI strip 25 x 4mm, by means nut bolt, nuts, check nuts and washer of the GI Earth wire protected by provision of GI light grade pipe 40 mm incl provision of concrete pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregated with 40 mm thick cover with RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg / Sqm) and frame of angle iron 25mm X 25 mm X 3mm with lugs 2 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, taste point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr, all as per electric plate No 3 of SSR Part I 2020 and connection to earth test point all as specified incl testing on completion”.
All as per item No. 86 above here-in-after but using 32 x 6 mm thick GI strip
S&F in repairs galvanized iron strip of size 25 x 4 mm as earth continuity conductor buried in ground or fixed to wall/floor/ground provided with porcelain insulators space no less than 0.5 mtrs complete all as specified and directed.
All as item No 88 above here-in-after but galvanized iron strip of size 32 mm x 6 mm
Cleaning/clearing of vegitation around the E&M installations and disposing off from site as directed and specified.
NOTES :- 1. The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum. 2. Unless otherwise specified the rates for PCC shall deemed to include the cost of formwork shuttering etc., required for complete and proper execution of the work. Refer Schedule A notes for details.
UNISON CONSTRUCTION
M/S MANAS MITRA
SUNIL DAS AND CO
M/S Banerjee construction co
SHRI P P SHARMA
M/S SUNNY ENTERPRISE
M/S P K ROY AND CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .