Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.9 LAccepted-AOC 31 TILAK NAGAR SRI GANGANAGAR 335001 RAJ | GANGANAGAR | RAJASTHAN | 335001 | ₹20.9 L | L1 | Accepted-AOC Accepted being lowest on 24 Dec 2020 |
| 2 | L2₹21.4 L+₹46,987.50 (2.25%)Rejected-Finance C O OPPOSITE BDO OFFICE MANDA AKHNOOR DISTT JAMMU PIN 181201 | JAMMU | JAMMU AND KASHMIR | 181201 | ₹21.4 L+₹46,987.50 (2.25%) | L2 | Rejected-Finance Rejected |
| 3 | L3₹22.9 L+₹2.0 L (9.38%)Rejected-Finance | ₹22.9 L+₹2.0 L (9.38%) | L3 | Rejected-Finance Rejected |
| 4 | L4₹23.6 L+₹2.7 L (13.0%)Rejected-Finance SUMEL BAMANWAS SWAI MADHOPUR | ₹23.6 L+₹2.7 L (13.0%) | L4 | Rejected-Finance Rejected |
| 5 | L5₹24.2 L+₹3.3 L (15.6%)Rejected-Finance H NO 273 VPO SURHERA WEST DELHI 110043 | WEST DELHI | DELHI | 110043 | ₹24.2 L+₹3.3 L (15.6%) | L5 | Rejected-Finance Rejected |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
19 Dec 2020, 6:00 pmClosed
GE Faridkot
Garrison Engineer, Faridkot-151203 Punjab 01639-264982
Provn of 165 x ceiling fan, Lt Panel, Flood lights, Geysers, bulk energy meter and Addn/Altn and improvement of RO water purifier (Cap 50 ltrs per hour) under AGE E/M at Faridkot Mil Stn
2020_MES_397061_1
GE FRD-65/2020-21
Open Tender
Miscellaneous Works
Item Rate
180 days
Faridkot Mil Stn
Class D Category b i
8 documents required · 8 mandatory
₹500
Yes
GE Faridkot
₹60,000
Yes
31 Dec 2020
21 Nov 2020
21 Dec 2020
21 Nov 2020
19 Dec 2020
5 Dec 2020
Amount
Point wiring complete with 1100 volts grade FRLS insulated unsheathed cable of copper conductor cable multi stranded of size 1.5 Sqmm single core drawn in including concealed PVC conduit 20mm dia with all accessories such as bend reducers /MS hooks, MS junction boxes 2mm thick galvanized steel pressed sunken terminal boxes of suitable sizes for mounting of switches sockets, fan regulators etc covered with 2.8mm thick plastic laminate (Hylem/Anchor) top cover including continuous earth wire of size 1.5 Sqmm PVC stranded copper conductor unsheathed, insulated stranded wire with different colour (red / blue/ yellow for line, black for neutral and green for earth point dolly for switch socket combination 5 Amp 5 Pin socket outlet one light point/fan point/call bell point, and indipendent board and making good surface after completion of work complete all as specified and directed by Engineer in Charge.
S&F Ceiling rose, three terminals with bakalite 20mm back plate complete all as specified and directed by Engineer in Charge.
Supply, fixing & hanging Ceiling fan (white colour) with complete accessories single phase, AC supply, 230 Volts, 1200mm sweep including canopies, three number blades, down rod, double ball bearing with capacitor of 2.5 mfd and making connection with three core copper flexible wire not less than 0.5 mtr for connecting from ceiling fan/connector to ceiling fan including writing MES Nos (Black, Roman, Italic or indian) n.exc 30cm height complete all as specified and directed by the engr-in-charge . Make : Khaitan, Orient, Crompton Greaves, Havells, Legrand
Supply, fixing & hanging Ceiling fan (white colour) with complete accessories single phase, AC supply, 230 Volts, 1400mm sweep including canopies, three number blades, down rod, double ball bearing with capacitor of 2.5 mfd and making connection with three core copper flexible wire not less than 0.5 mtr for connecting from ceiling fan/connector to ceiling fan including writing MES Nos (Black, Roman, Italic or indian) n.exc 30cm height complete all as specified and directed by the engr-in-charge . Make : Khaitan, Orient, Crompton Greaves, Havells, Legrand
S&F ceiling fan regulator step down electonic type, single phase, AC supply, 230 volts to be fixed on laminated sheet top cover and connecting up complete all as specified and directed by Engineer-in-Charge.
S&F switch piano flush type single pole one way 5 /6 Amp,230 VAC supply complete all as specified and directed by Engineer in Charge.
Supply and fixing of ceiling fan hooks 12mm to 15mm rod in S shape to the ceiling rod including chipping and cleaning with necessary work in RCC roof complete all as specified and directed by Engineer-in-Charge.
Taking down carefully copper/aluminium point wiring (light, fan, socket, bell or power) complete including fittings such as switches, ceiling roses, pendent holders, light fittings any type, sockets, regulators etc and making good disturbed surfaces of walls and floors etc to match with the existing surfaces complete all as specified and directed by Engineer-in-Charge
Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth; or n exc 10 Sqm on plan and n exc 1.5 m in depth for foundations of poles, struts, stays etc. or laying underground cable etc. in soft/loose soil, & getting out including taking out old brick or precast cable cover for reuse complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, excavated soil including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed by Engineer-in-Charge
Removal of excavated surplus soil to a distance n.exc 50m and depositing where directed at level not exceeding 1.5 m above the starting point complete all as specified & directed by Engineer-in-charge
M & L for sand cushioning with dry coarse sand to under ground cable 23 cm thick, 8 cm thick below the cable and 15 cm thick after laying the cable complete all as specified and directed by Engineer-in-Charge. Note : Thickness after punning shall be considered for payment.
M & L for brick protection with old size sub class 'B' bricks laid flat , length of bricks across the route of underground cable complete all as specified and directed by Engineer-in-Charge.
Boring/Drilling ( horizontally) manually under existing road ( maximum 10 M in width) suitable for passing GI tubing of 40 to 100 mm bore complete all as specified and directed by the engineer in charge.
Supply and fix Galvanised mild steel pipe/tubing of size 40 mm bore dia, light grade complete with all fittings, laid in trenches / under roads, drain, paths, fixed to poles / walls with mild steel clamps, bolts, nuts and washers complete all as specified of following bore and as directed by Engineer-in-Charge. Note : Excavation & earth work, Mild steel clamps, bolts, nuts and washers shall be measured and paid separately)
Supply and laying XLPE insulated stranded and PVC sheathed heavy duty armoured electric cable with stranded aluminium conductor 1100 Volts grade confirming to IS - 7098 cross sectional area 16 Sqmm 4 core including thimbles / lugs with and including passing through pipe along wall, under road crossing / Nallah / under floor etc complete all as specified and directed by Engineer in Charge. (Note : Earth work, sand cushioning, GI pipe protection and brick protection to be measured and paid seperately).
Supply and laying XLPE insulated stranded and PVC sheathed heavy duty armoured electric cable with stranded aluminium conductor 1100 Volts grade confirming to IS - 7098 cross sectional area 70 Sqmm 3.5 core including thimbles / lugs with and including passing through pipe along wall, under road crossing / Nallah / under floor etc complete all as specified and directed by Engineer in Charge. (Note : Earth work, sand cushioning, GI pipe protection and brick protection to be measured and paid seperately).
Supply and laying XLPE insulated stranded and PVC sheathed heavy duty armoured electric cable with stranded aluminium conductor 1100 Volts grade confirming to IS - 7098 cross sectional area 25 Sqmm 4 core including thimbles / lugs with and including passing through pipe along wall, under road crossing / Nallah / under floor etc complete all as specified and directed by Engineer in Charge. (Note : Earth work, sand cushioning, GI pipe protection and brick protection to be measured and paid seperately).
S & F Mild steel cross arms, bracings, stiffeners, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed complete all as specified and directed by Engr-in-Charge.
Supply, fixing and testing LED flood light fitting of 160 Watt fitted on 4 to 9 meter high octagonal pole including LED lamps complete with body robust, corrosion, resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die cast aluminium alloy. The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP-65 protection as per IS-10322-1982 (Part-I) with latest amendments and input voltage range 140-300V, AC, frequency 50-60 Hz, PF should be more than 0.9 with total harmonic distoration THD (I) less than 15%, cool white colour and lamp starting time should not be more than 10 second, Fittings should be provided with 10 KV surge protection. Driver should be constant current constant voltage driver. Driver should have high voltage withstanding capacity upto 300V, AC. Driver should also have double phase protection, no load, open circuit and short circuit protection. LED light fittings should be suitable for ambient temperature from - 10 degree centrigrade to 50 degree centigrade and humidity level 10% to 90% RH. Covers should be polycarbonate/ toughened glass to ensure minimum IP 65 degree protection cover should not degrade due to heating and ageing. The efficient of LED luminaries system shall be more than 85 lumens per watt and must be certified by LM-79 test report complete all as specified and directed by Engineer-in-Charge. Make: Philips, Wipro, Bentech, Jaquar & Co Pvt Ltd, Syska LED Lights Pvt Ltd (Syska), Halonix technologies Pvt Ltd (Halonix), C & S Electric Ltd, Havells Note :- (a) Bidder shall submit test report of LED street light fitting from accredited test laboratory for LM-79 (b) Bidder has to furnish a replacement warranty of 05 years for LED light fittings complete including lamps from the date of completion of CA. The product will be replaced free of cost in the following cases : - (i) Manufacturing defects, (ii) Failure due to mechanical and electrical impact, (iii) Drop in lumen (or lux at 1m) below 90% of claimed values of lumen (or lux at 1m) of the LED/ luminairies. (c) All LED light luminaire must meet the provision laid down in IS-16101, 16102 Part-I/II, 16103 Part-I, 16104, 16105, 16106, 16108/2012 and 15885 Part-II/ Section 13 (d) scope of work shall include supply and fixing street light fittings on poles which includes needful T & P and required accessories etc if any, complete including making connection, testing etc complete. No extra payment is admissible on these account. Note: Every light fitting will be warranty 5 years after completion of CA and replacement/defects as applicable should be complied/rectified within 7 days .
Supply & fixing in replacement of PVC insulated multi stranded aluminium conductor PVC cable sheathed 4 sqmm two core and making connection of street light fittings with overhead lines/ UG cable complete all as specified and directed by Engineer-in-Charge.
Point wiring complete with 1100 volts grade FRLS insulated unsheathed cable of copper conductor cable multi stranded of size 2.5 Sqmm single core drawing through concealed conduit terminated with steel pressed sunken terminal boxes and 2.5 sqmm PVC stranded copper conductor insulated unseathed stranded (Green colour) connected to common earth point dolly for earth plug & socket with MCB complete all as specified and directed by Engineer in Charge.
S&F Plug metal clad SP & N with a 2 pin earth plug and socket with MCB SP 20 Amps suitable for working on 230 volts AC complete all as specified & directed by Engineer-in-Charge.
Supply and laying mild steel water tubing medium grade galvanised of size 15mm bore with all fittings and laid in trenches under floor/ road or on wall complete all as specified and directed by Engineer-in-charge
Supply, installation, commissioning and testing water storage heater (geyser) vertical type of 25 ltr capacity, ultathick stainless steel superior 304 Gde PUF insulation thermostate, thermal cut off, 1PX4 multifunctional safety valve technology, feroglas dry powder coating finish, suitable for to operate / function on AC 220 V, single phase having heating element of 2 KW capacity and high thermal cut-out, energy saving BEE 3 star rating or above including fixed along walls including grouting fastening & fixing (04 Nos) 16mm dia 150mm long GI bolts & nuts, washers and connecting up inlet/ outlet with cold water PVC connection pipes and electric connections cable cord min 1.50m length with copper conductor cable 3 core and 3 pin plug 15/16 Amp, including making good the disturbed surfaces matching with existing complete all as specified and directed by the Engr-in-charge. Make :- Havells, Bajaj, Surya, V Gaurd, Crompton Greaves, Racold, Jaquar & Co Pvt Ltd Note : PVC connection will be measured & paid separately.
Supply & fixing PVC connections 15mm size with PTMT nuts of length 300mm suitable for (Hot & cold pipe) application complete all as specified & directed by Engineer-in-charge.
S&F sub-main wiring with two single core cables PVC insulated and un-sheathed 6 sqmm (Nominal Area) FRLS stranded copper conductor drawn into PVC concealed conduit, including one run 6 Sqmm (Nominal Area) copper cable as earth continuity conductor including necessary connections, PVC flexible pipes are used in panel board while connecting the cable complete all as specified and directed by Engineer-in-Charge. Note : Two runs of 6 Sqmm single core cable and one run of 6 sqmm copper wire earth continuty conductor and conduit with fittings shall be measured as one length.
Disconnecting and taking down unserviceable membrane and replacement with new brackish water membrane 04 Nos in each set of plant and connecting including jointing materials all as per site requirement complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable flow restriction high pressure booster pump - 02 Nos of 150 GPD each and supply and fixing to match with existing one including making all water and electric connection complete with other items required at site to make functionable in all complete all as specified and directed by Engineer-in-Charge.
Disconnecting and taking down unserviceable post activated carbon media filter and replace with new activated corbon filter media complete all as specified and directed by Engineer-in-Charge.
Disconnecting and taking down unserviceable sedimentation filter and replace with new sedimentation filter media as per size required at site complete all as specified and directed by Engineer-in-Charge.
Replacement of cartidge 10 micron jumbo cartridge assembly and pre activated carbon media filter assembly complete all as specified and directed by Engineer-in-Charge.
Repair and replacement if required at site or modification of housing / piping for membrane 04 Nos in each plant system complete all as per site requirement and complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of Antiscalant (3 to 5 PPM) complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of Sodium Hypochloride complete all as specified and directed by Engineer-in-Charge.
Replacement / repair of some misc items required such as coagulant mixing unit, agigator, solonoid valves, gauges, TDS meters connecting pipe and fittings etc complete all as per site requirement and complete all as specified and directed by Engineer-in-Charge.
Testing, commissioning of RO Plants for rated discharge, smooth functioning, water qution as per IS-10500-1991 amended 1993 complete all as specified and directed by Engineer-in-Charge.
S & F exhaust fan 300mm sweep, 1380 RPM (Trans air 4 blade) 70 watt, with louver shutter suitable for operation on 220/230 volts, single phase , AC and complete all as specified & directed by Engr-in-charge. Make : Crompton, Khaitan, Bajaj, Almonard, GEC, Havells, Surya Roshni Ltd
S & F and testing microprocessor based single phase electronic tamper proof energy meter of rating class-I LCD display of rating 10 to 60 amps with optical communication port conforming to IS-13779 duly sealed by lead and steel wire, necessary alteration for fixing new LCD energy meter including suitable size of FRP enclosure and locking arrangement and glass cover including removing old unserviceable energy meter any type any make and prepared list as old meter reading and new meter reading and Ser No. respectively and old meter deposit to MES store complete all as specified & directed by Engr-in-charge. Make : LT / HPL
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.3 mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick packed layer of charcoal dust and common salt, connected to galvanized iron strip 32mm x 6mm thick as earth lead by means of bolts, nuts and washers of galvanised iron or steel and thimbles and other end of the earth strip connected to earthing test point/equipment and protected by galvanised iron pipe light grade 50mm dia upto earthing test point/equipment fixed with 2 Nos of mild steel clamp made out 25mm x 3mm flat iron and perforated water pipe 20mm dia GI medium grade and top with socket & plug and bottom connected to earth plate by slit and two bolts/nuts/washers, PCC chamber in cement concrete (1:3:6) type C-1 and CI cover with frame all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009. Note:- (i) Outer edge of earth pit shall be 1 metre away from the outer edge of PCC chamber. (ii) GI strip upto earth test point/equipment is included in this item. (iii) Water pipe shall be provided in slantling position.
M&L for for jointing & testing of cable end termination (heat shrinkable) jointing kit for 11 volts UG cable including sleeves suitable for LT XLPE cable of size 25 Sqmm 4 Core complete all as specified and directed by Engineer-in-Charge.
Supply, install, test and commisioning out door type cubical panel board weather and vermin proof Kiosk type fabricated from 3.15mm thick CRCA sheet steel and MS angle section 40x40x6mm on PCC 1:2:4 type B-1 platform 40cm above the ground level and 45cm below the ground level, frame factory fabricated with front openable lockable / openable by keys having chromium plated 19mm dia fancy lock, louvers and air vent gasket for natural flow of air "U' type gasket shall be used to make the outer shell completely vermin proof suitable for 3 Phase, 4 wire 415 volts, 50Hz, tested at CPRI for 35MVA rupturing capacity at 415 volts factory fabricated having modern fabrication and testing process which includes seven tank pretreament process comprising of degreasing, rinsing, de-rusting, rinsing, phospatising, rinsing and passivation followed by powder coated painting inside & outside with approved paint over a coat of primer, provided with suitable gasket to make it dust / vermin proof and general construction conforming to IS:8623/93. Cubical panel should have two earth terminal including suitable holes for incoming and control cable. Panel should have sufficient space to accomodate one Number three phase electric energy meter and S&F one Number four pole MCCB 63 Amps 25 KA incuding necessary wiring & excavation, coping, foundation etc complete all as specified and directed by Engineer-in-Charge.
Supply, fixing, connecting and testing microprocessor based three phase four wire, 50 Hz + 5%, 400/415 volts (P-P) electronic tamper proof CT/PT operated trivecetor energy meter for LT & HT, premier series (ISI marked) in poly carbonate body with LCD display, of current range -/5 (10)A, -/1(2), Accuracy class 0.2s, 0.5s for HT and class 0.5s, degree of protection IP-51, optical port for local communication, CT ratio 300/5 Amps demand and load survey featurers conforming to IS-13770 including cable connection with suitable size ferrule lugs, fixing of CTs in existing incoming cable in existing panel and M & L control cable with flexible PVC pipe from CT to electric meter for connections complete all as specified and directed by Engineer-in-Charge. : Make : Secure/ Havells / Legrand / Indoasian Note :- A Sum of Rs. 105.00 will be deducted on account of credit for dismantling/demolished/taking down material. Please refer detail on srl page No 23 (Schedule of credit) of Tender Documents.
DEEPAK ENTERPRISES
NEW AMRITSAR CONSTRUCTION COMPANY
GS and Co
M/S RAJESH KUMAR and CO.
ARORA CONSTRUCTION CO.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .