Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.8 LAccepted-AOC 3RD FLOOR VVIP RESIDENCY MAHINDER VIHAR CHAKRATA RD NEAR RAMADA HOTEL DEHRADUN UTTARAKHAND 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L1 | Accepted-AOC being lowest | |
| 2 | L2₹17.4 L+₹1.1 L (6.85%)Rejected-Finance | L2 | Rejected-Finance Not Being Lowest | |
| 3 | L3₹20.1 L+₹3.8 L (23.6%)Rejected-Finance OFFICE NO 101 MALAN PLAZA NEXT TO ESSAR PETROL PUMP NEAR GODAMBLE CORNER RAHATNI PIMPRI DP ROAD RAHATANI PUNE 411 017 | PUNE | PUNE | MAHARASHTRA | 411017 | L3 | Rejected-Finance Not Being Lowest |
Tender Value
₹24 L
EMD Value
₹48,000
Closing Date
25 Sept 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (CME) Kirkee
Garrison Engineer (CME) Kirkee, Phugewadi, Dapodi, Pune - 411 012
COMPREHENSIVE MAINTENANCE INCLUDING REPAIR/ REPLACEMENT OF SUMMER COOLING APPLIANCES AT CME
2020_MES_373910_1
8110/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Garrison Engineer (CME) Kirkee
Class D c(i)
9 documents required · 9 mandatory
₹500
Yes
Garrison Engineer (CME) Kirkee
₹48,000
Yes
9 Apr 2021
1 Sept 2020
28 Sept 2020
1 Sept 2020
25 Sept 2020
12 Sept 2020
2 Sept 2020 - 11 Sept 2020
60 days
Amount
M & L for comprehensive maintenece and servicing of Split type Air conditioner/Window type unit of any capacity outer and inner unit both of any make including cleaning the dust from body with blower, cleaning of condenser and cooling coil, checking all connections including functioning of metal clad socket/DP switch, function of relay, capacitors, overload protector, thermostat, fan motor, fan/blower drum, main control board PCB, electronic contol box, etc, oiling/greasing of fan motor, checking serviceability, cleaning of the air filter woolen felt & refixing ensuring for air tighting complete, repair and replacement of warn out/unserviceable spares including taking down and refixing, transportation to and from workshop if required and refixing it in its original place after fully servicing including testing & commissioning all as specified and directed by Engineer-in-Charge. (Note: Spares parts replaced shall be measured & paid under saperate item)
do - all as per Item No 1 above but for Water cooler/Deep freezer/Refrigerator of any type and any capacity
Supply only starting capacitor 80-100mfd for AC, water cooler, Refrigerator, deep freezer etc all as specified and directed.
Supply only running capacitor 10MFD
Supply only running capacitor 36MFD
Supply Only running capacitor 50MFD
Supply Only running capacitor 60MFD
Supply only blower motor capacitor 4MFD to 6MFD
Supply only starting relay suitable for water cooler, AC, and refigerator, deep freezer for any make and model opreated on single phase 230 volts all as specified and directed.
Supply Only for over load relay compridsing of over load protection suitable for air contioner, water cooler, deep freezer and refrigerator opreated in shingle phase 230 volt all as specified and directed.
Supply Only themostat switch suitable for Air conditioner, water cooler, deep freezer and refigerator operated on single phase 230 volts supply all as specified and directed.
Supply only drier filter for AC ,water cooler and refrigerator.
Supply only magnetic contactor as in outer unit of Split type air conditioner as per existing type complete all as specified and directed.
Supply Only capillary tubes for the following :-
Air Conditioner 1.5 ton /2 ton and Water cooler 40to 150 ltr
Refrigerator & Deep freezer upto 400 ltr
Supply only indoor fan motor of split type AC of any capacity
Supply Only Condensor fan motor 1300rpm, 1/6Hp, 1/8Hp, 1/10Hp for Split type Air Conditioner outdoor unit of 1.0Ton/1.5Ton/2.0Ton as per existing make and capacity all as specified and direted by Engineer In Charge
Supply Only Condensor fan motor double shaft 1/6Hp, 1/8Hp, 1/10Hp for Window type AC of 1.0Ton/1.5Ton/2.0Ton as per existing make and capacity all as specified and direted by Engineer In Charge
Supply Only Condensor fan motor 1/36Hp for Water Cooler of 40-80Ltr and deep freezer upto 400Ltr as per existing make and capacity all as specified and direted by Engineer In Charge
Supply Only Condensor fan motor 1/6Hp, 1/8Hp, 1/10Hp for Water Cooler of 120-150Ltr as per existing make and capacity all as specified and direted by Engineer In Charge
Supply only blower/condensor fan blades as per existing make & type for Air conditioner/Water cooler/deep freezer all as specified
Supply, install, test & commissioning harmetically sealed New compressor for Split Type AC of capacity 1.5TR duly charged with fresh freon gas etc complete all as specified/directed by Engineer-in-Charge including taking down old u/s compressor. Make- Voltas/Shriram/LG/Godrej/Kirloskar or as per existing make at site.
-do - but for Split Type AC of capacity 2.0 TR
-do - but for Window Type AC of capacity 1.5TR
-do - but forWindow Type AC of capacity 2.0TR
-do - but for Water Cooler of capacity 40 to 80Ltr
-do - but for Water Cooler of capacity 120 to 150Ltr
-do - but for Refrigerator 165 to 210Ltr Capacity
-do - but for Refrigerator 286 to 310Ltr Capacity
-do - but for Deep freezer up 298 to 310 ltr capacity
M & L for Detecting the gas leakage, rectifying the defects including repair to condensor coil/evaporator coil by means of welding, soldring etc, vacumizing and charging, topping up fresh freon Gas and commissioning and testing for the 1.5Ton/2.0ton split type/window type AC all as specified and directed by Engineer In Charge
All as per item No 30 herein above but of water cooler, refrigerator & deep freezer of any type and any capacity
Supply and replace remote control unit of Split type AC 1.5 ton/2.Ton including making frequency arrangement of new remote with existing system all as specified and directed by Engineer In Charge
Supply only Electronic PCB unit for main control panel of Split type/Window Type AC of any capacity
M&L for dismantling of existing unserviceable voltage stabilizer for repairs including replacement of relays , electronic voltage sensor circuits and meter, micro switch , indication light RC fitters and other connected items for making funcional as per the entire satisfaction of Engr-in-charge and rewinding of unserviceable transformer with super enameled copper wire of appropriate size , varnishing assembling and testing complete for following capacities:-
Upto 1 KVA
Upto 2 KVA
Upto 4 KVA
Upto 5 KVA
M&L for dismantling of existing unserviceable power UPS for repairs and replacement of unserviceable parts like relays , electronic voltage sensor circuits, meters, micro switch , indication light RC fitters, rectifiers, transformers as per existing capacity and specifications and other connected items for making funcional as per the entire satisfaction of Engr-in-charge and testing complete for Capacity upto 5KVA
Disconnecting electrical / mechanically and lowering to the ground for repairng / over hauling the desert cooler including replacement of canvas grass / wood wool pads and spary painting to body with one coats of anti corrisive red oxide primer for any make of desert cooler to make it fully funcitonal including replacement of unservicable/defective spare parts, transportation to and from, re-installation and testing on completion to the entire satisfaction of Enineer -in - charge Note : Spares replaced will be measured and paid under saperate Item
Supply only water lifting pump 1/70 HP capacity , operated on single phase 230 volts with all accessories and testing complete to the entire satisfaction of Engr -in-charge.
Supply only fan motor of desert cooler of any capacity including supporting legs , nuts and bolts etc.
Supply only fan balde with bush for desert cooler motor
Supply only electronic control circuit board (PCB) as per existing type for desert cooler.
Supply only swing motor for air cooler
S & F Metal Plug Tops for 2Pin and earth socket AC Box of capacity 240V, 20A all as specified and directed
Supply Only PVC flexible pipe 25 mm dia as in drain pipe suitable for water cooler outlet
S&F incl connecting sheet metal enclosure with two pin and earth plug and socket complete, with one double pole MCB 20 Amp Make : Havells/ Standard/ HPL.
S&F in repairs Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule for 15mm bore dia.
S & F in repair Push tap Self closing taps of size 15mm of cast iron or malleable cast iron, galvanised, screwed for iron pipe or for water cooler
Supply and fix PVC connecting pipe with brass nuts and washers at both ends of length not exceeding 60 Cms for connection of water coolers with taking down old pipe
M&L for wiring for circuit /sub main wiring with earth wire of size 2x 4.0sqmm + 1 x 2.5sqmm of FR PVC insulated copper conductor, single core cable in surface drawing in and including PVC casing capping.
Taking down unserviceable/damaged Sub main wiring any type any size including continious earth wire, conduit/casing and making good disturbed surfaces of walls/ceiling matching with existing tint.
M & L for Framed work such as grills, gratings, etc. for water tanks, water cooler stand, AC Unit supports, UPS Battery Stand and similar work conforming to Fe.290.Gde-E-165 with two coat of synthetic enamaled paint over coat of red oxide primer including preparation of new steel surface incl taking down old unsrviceable one all as directed and specified by Engineer In Charge
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA.wall mounted.
M & L for repair/replacement to stainless steel waste water tray including welding, polishing, riveting, provision of fixing screws and refixing.
M& L for Gaskets for top cover for water cooler of any capacity and make as per site requirement.
M & L for replacement damage cooling coil for refrigerator of capacity 210/300 ltrs
M & L for replacement damage condensor coil for refrigerator of capacity 210/300 ltrs
Supply Only door switch for refrigerator of any type and any capacity
Supply only pigmy lamp (indoor lamp) as per existing type for refrigerator
Supply only fridger door as per existing make and typr for refrigerator
Supply only timer switch assembly for refrigerator as per existing for capacity 210 to 300Ltrs
M & L for carry out routine maintenece and servicing of Package type air conditioner of capacity 8.5TR & 11TR including removing the dust from body with blower, cleaning the condenser and cooling coil, checking all the electrical and refrigeration piping connections, checking function of relay, capacitors, overload protector, thermostat, fan motor, blade, fan/blower drum, LT Control panel, VFDs, electronic contol box, etc, oiling/greasing of fan motor, checking serviceability, cleaning of the air filter woolen felt & refixing ensuring for air tighting complete, repair and replacement of warn out/unserviceable spares including taking down and refixing, transportation to and from workshop if required and refixing it in its original place after fully servicing including testing & commissioning all as specified and directed by Engineer-in-Charge. Note: 1. Spares parts replaced shall be measured & paid under saperate item
Supply only V-Belt Type 13x813A 32A840EL for Blower fan of Package AC Unit of Capacity 8.5TR/11TR
Supply only relay HP & LP for package type AC plant of capacity 8.5TR
Supply only relay HP & LP for package type AC plant of capacity 11TR
Supply only condensor fan motor , 230V,50Hz 920rpm 1/3Hp for package type AC, Model: 14B606A1E/2L-FP7 Make: Micro Instrument Co. or equivalent
Supply & fixing in replacement including connection 3 pole AC power contactor, 32 Amps, 415 Volt with auxilary contact 1NO + 1NC, having coil voltage 380 to 400 Volts Make Simens cat ref C4NE22 or equivalent of L &T/Havells.
Supply, fixing and connecting in replacement Intigrated circuit board with all electronic components suitable for 8.5 TR capacity Carrier Pakage type Air conditioner.
Supply, fixing and connecting in replacement Intigrated circuit board with all electronic components suitable for 11 TR capacity Carrier Pakage type Air conditioner.
Supply, fixing and connecting in replacement SPPR Circuit board suitable for 8.5TR/11TR cap Package AC of Make Carrier.
Supply and fixing of 3Ph, 415V, 50Hz compressor of capacity 11TR suitable for package type AC
Supply and fixing of 3Ph, 415V, 50Hz compressor of capacity 4.25TR suitable for package type AC
..-do-.. all as per Item No 61 above but for carry out repair/maintenance of 3Phase, 415V, 50Hz Ductable type AC indoor and outdoor unit of capacity 8.5TR complete all as specified and as direted by Engineer In Charge.
Supply and fixing of condensate drain pump of ductable type AC of capacity 8.5TR
Supply and fixing of Condensor fan motor suitable for ductable type AC of capacity 8.5TR
Supply and fixing of fan blade suitable for outdoor unit of capacity 8.5TR ductable AC
Supply and fixing of Blower Motor suitable for Carrier Make Ductable type AC of capacity 8.5 TR
Supply and fixing of Direct driven forward curved type centrifugal Blower fan suitable for Carrier Make Ductable type AC of capacity 8.5 TR
Supply and fixing of Electronic PCB Kit for control panel suitable for Carrier Make Ductable type AC of capacity 8.5 TR
Supply and fixing ofcompressor 3Ph, 415V, 50Hz of capacity 8.5TR for carrier make ductable Air conditioner
do- all as per Item No 61 above but for carry out repair/maintenance of 3Phase, 415V, 50Hz Ceiling Mounted Cassette type AC indoor and outdoor unit of Capacity 4.0TR complete all as specified and as direted by Engineer In Charge.
M & L for replacement of condensate drain pump assembly of cassette type AC of capacity 4.0TR
Supply and fixing of Sensor unit for water pump of carrier make casset type AC indoor unit (as per existing).
Supply and fixing of Condensor fan motor suitable for cassette type AC of capacity 4.0TR
Supply and fixing of Fan blade made of HD PVC suitable for Carrier make assette type AC of capacity 4.0TR outdoor unit incl lock nut.
Supply and fixing of Blower Motor/Indoor fan motor suitable for Carrier Make Cassette type AC of capacity 4.0 TR
Supply and fixing of Electronic PCB Kit for control panel suitable for Carrier Make Cassette type AC of capacity 4.0 TR
Supply and fixing of compressor 3Ph, 415V, 50Hz of capacity 4.0TR for carrier make Cassette type Air conditioner
Supply and fixing of three phase 3Ph, 415V, 50Hz overload protection relay suitable for ductable/casstte AC.
Supply and fixing of Air brake power contactor 3 phase AC 50 Hz 415V, 15Amps (as per existing) suitable for 4.0 TR Cassete type Air Conditioner.Make: Siemens/C&S/L&T/BCH
Supply and fixing of single phase preventor relay suitable for ductable/casstte AC.
M & L for detecting the gas leakage,rectifyiong the defects including repair to condenser coil/evaporator coil by meanss of welding soldfring etc vacumizing and charging topping up fresh freon gas commissiong and testing for the 11 TR pakage type AC .
All As per Item No 91 but for 4.25TR Compressor of 8.5TR Package type AC plant.
All As per Item No 91 but for 8.5TR Compressor of ductable type AC.
All As per Item No 91 but for 4.0TR Compressor of ceiling mounted ductable type AC.
BRILLIANT AIRCONDITIONING AND REFRIGERATION WORKS
M/S. Niksun Electro-Infra Private Limited
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .