| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | FIRST₹9.3 LAccepted-AOC NO S 7 2ND CROSS 2ND MAIN KEB LAYOUT SANJAYANAGAR BANGALORE 560094 | BENGALURU URBAN | KARNATAKA | 560094 | FIRST | Accepted-AOC BEING LOWEST | |
| 2 | SECOND₹9.9 LRejected-Finance | SECOND | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹12.9 L
EMD Value
₹25,800
Closing Date
13 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) MARATHAHALLI
GE AF MARATHAHALLI WIND TUNNEL ROAD, KEMPAPURA, YEMALUR POST, BANGALORE. PIN- 560037
REPAIRS AND MAINTENANCE OF SUMMER COOLING APPLIANCES UNDER GE AF MARATHAHALLI BANGALORE
2021_MES_481270_2
8909/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) MARATHAHALLI
AS PER ENIT
7 documents required · 7 mandatory
₹500
GE (AF) MARATHAHALLI
₹25,800
Yes
11 Mar 2022
22 Nov 2021
18 Dec 2021
22 Nov 2021
13 Dec 2021
30 Nov 2021
60 days
Amount
Material and Labour for servicing of Window type AC and taking out the AC from its existing position/location, shifting the same, servicing the condenser and cooling coil with blower, cleaning the coils with caustic soda, replacement of sheet metal screws wherever necessary applying oil in fan motor bushes checking and rectifying the wiring defects, proper setting of thermostat & other electrical/ Refrigerant controls, cleaning the air filter, re-installing in its original position, connecting up all connections and testing complete all as specified and as directed for Window type Air Conditioner of 1.0 Ton. Note : Gas Charging shall be measured and paid separately under relevant item of this schedule
All as per item No.1 here in before but for Window type Air Conditioner 1.5 Ton complete all as specified and as directed
All as per item No.1 here in before but for Window type Air Conditioner 2.0 Ton complete all as specified and as directed
Taking out burnt/ unserviceable sealed compressor Unit from Window type air conditioner, Supply & replacement factory sealed compressor unit, connecting refrigeration system after thorough flushing out the system with dry nitrogen, leak testing with nitrogen, vaccumising including neccessery brazing and welding arresting leakages and gas charging with refrigerant gas, testing, re-installing in its original position/location connecting up all electrical connections, testing the complete unit complete all as specified and as directed for Window type Air Conditioner 1.5 Ton. Notes :– (i) Factory sealed compressor unit shall be of existing capacity and make. (ii) Gas Charging shall be measured and paid separately under relevant item of this schedule.
All as per item No.4 above, but , for Window type Air Conditioner 2.0 Ton complete all as specified and as directed
Material and Labour for removing the Window type Air conditioner from installed position leak testing and arresting the leakages in condensor/evaporator coil by brazing etc and refixing complete for window type AC of 1.0 ton / 1.5 ton / 2.0 ton capacity complete all as specified and as directed
Material and Labour for charging of refrigerant gas F-22 / R-22 /R-32 / R-134A to the Window type Air conditioner, water coolers, Refrigerator and Split type air conditioner after vaccumising the complete system & pressure test with nitrogen to ensure complete system leak proof, testing of air conditioners, water coolers for proper functioning & cooling effect complete all as specified and as directed
Taking out the defective spare parts of window type AC of any capacity at its existing location by drawing out the AC from outer cover, supply and fixing new spare parts after thorough checking and rectification of defects in wiring circuits, pushing back the unit in its outer cover, testing and commissioning complete all as specified and as directed NOTE:- Supply of spare parts will be measured separately under relevant items of this schedule.
Servicing the Voltage Stabilizer 4 KVA single phase of make - Soft line or equivalent after strip opening covers, taking out the burnt out winding from the transformer rewind with super enamelled copper winding wire, insulate properly, setting/testing of buck/boost relay, replacement of U/S electronic parts, assemble back & fixing in its original position including testing for proper functioning complete all as specified and as directed.
Servicing the Voltage Stabilizer 5 KVA single phase of make - Soft line or equivalent after strip opening covers, taking out the burnt out winding from the transformer rewind with super enamelled copper winding wire, insulate properly, setting/testing of buck/boost relay, replacement of U/S electronic parts, assemble back & fixing in its original position including testing for proper functioning complete all as specified and as directed.
Material and Labour for complete servicing after pumping down Indoor/outdoor units of split AC complete by cleaning condenser/ Evaporator coil with air blower, wet servicing of condenser coil unit with caustic soda etc, replacement of sheet metal screws wherever necessary applying oil in fan motor bushes checking and rectifying the wiring defects, proper setting of thermostat & other electrical/ Refrigerent controls, cleaning the air filter, duly painted with one coat of red oxide to the inner side and two coat of spray painting to the outer side of the outdoor unit after remove the out door unit, connecting up all connections and testing after gas charging if required for Split type Air Conditioner up to 1.0 Ton complete all as specified and as directed Notes :- (i) The rate deemed includes for minor spares (ii) Gas shall be measured and paid separately under relevant item.
All as per item No.11 above, but, for Split type Air Conditioner up to 1.5 Ton complete all as specified and as directed
All as per item No.11 above, but , for Split type Air Conditioner 2.0 Ton complete all as specified and as directed
All as per item No.11 above, but , for Split type Air Conditioner 2.5 Ton complete all as specified and as directed
All as per item No.11 above, but, for Split type Air Conditioner 3.0 Ton ( 2 x 1.5 Ton) complete all as specified and as directed
Taking out burnt/ unserviceable sealed compressor Unit from split type air conditioner, Supply & replacement factory sealed compressor unit, connecting refrigeration system after thorough flushing out the system with dry nitrogen, leak testing with nitrogen, vaccumising and gas charging with refrigerant gas, testing, re-installing in its original position/location connecting up all electrical connections, testing the complete unit all as directed for Split type Air Conditioner 1.5 Ton complete all as specified and as directed Notes:- (i) Factory sealed compressor unit shall be of existing capacity/Make. (ii) Gas Charging shall be mesasured and paid separately under relavent item
All as per item No.16 above, but , split type Air Conditioner 2.0 Ton complete all as specified and as directed
All as per item No.16 above, but, split type Air Conditioner 2.5 Ton complete all as specified and as directed
Material and Labour for removing the Split type Air conditioner outdoor unit/indoor unit from installed position leak testing & arresting the leakages in condenser coil by brazing etc complete for Split type AC 1.5 ton / 2.0 ton / 2.5 ton complete all as specified and as directed. Note :- Gas Charging shall be mesasured and paid separately under relavent item
Taking down the Unserviceable IDU blower motor and Supplying and Fixing IDU blower motor capacity as per existing make for 1.5 Tr split AC complete all as specified and as directed
Taking down the Unserviceable IDU blower motor and Supplying and Fixing IDU blower motor capacity as per existing make for 2.0 Tr split AC complete all as specified and as directed
Taking down the Unserviceable Condenser fan blade and Supplying and Fixing as per existing make for Condenser fan blade 1.5 TR complete all as specified and as directed
Taking down the Unserviceable Condenser fan blade and Supplying and Fixing as per existing make all as directed for Condenser fan blade 2.0 TR complete all as specified and as directed
Taking down the Unserviceable Condenser fan motor and Supplying and Fixing as per existing make all as directed for 1.5 TR split AC complete all as specified and as directed
Taking down the Unserviceable Condenser fan motor and Supplying and Fixing as per existing make all as directed for 2.0 TR split AC complete all as specified and as directed
Supply only Starting Capacitor of 80 / 100 mfd complete all as specified and as directed
Supply only Running Capacitor 36 / 45 mfd complete all as specified and as directed
Supply only Potential Relay complete all as specified and as directed
Supply only Thermostat complete all as specified and as directed
Supply only Control Knob complete all as specified and as directed
Supply only capacitor 1.5 mfd to 4 mfd complete all as specified and as directed
Supply only swing blade opertated motor for indoor split unit up to 2 ton complete all as specified and as directed
Supply only Blower bush for indoor split unit up to 2 ton capacity complete all as specified and as directed
Supply and fixing AC timer suitable for controlling 2 Nos split AC complete all as specified and as directed
Supplying and Fixing in repairs Copper refrigerant pipe Copper tube 1/2 " x 1/4" complete all as specified and as directed
Supplying and Fixing in repairs Copper refrigerant pipe Copper tube 5/8 " x 1/4" complete all as specified and as directed
Taking down perished Unserviceable insulation cover of refrigerent piping and Supplying & Fixing brutile rubber insulation for refrigerent pipings of suitable size complete all as specified and as directed
Taking out existing Unserviceable Remote Control and Supplying & Fixing Remote Control with cord wire for Split type AC 1.5 ton / 2.0 ton / 2.5 ton complete all as specified and as directed
Taking out existing Unserviceable Air Filter and Supplying & Fixing Air filter for Split type 1.5 ton / 2 ton /2.5 ton complete all as specified and as directed
Removing existing Unserviceable fan motor of Condenser of Split type AC & rewinding of fan motor with suitable size of super enamelled copper winding wire etc complete for Split type AC 1.5 ton / 2.0 ton / 2.5 ton complete all as specified and as directed
Supply Only Controller Card for Split type AC 1.5 ton / 2.0 ton / 2.5 ton complete all as specified and as directed
Supply Only Micro Controller with Embedded software for Split type AC 1.5 ton / 2.0 ton / 2.5 ton complete all as specified and as directed
Supply Only Relays for Split type AC 1.5 ton / 2.0 ton / 2.5 ton complete all as specified and as directed
Supply Only Sensors with 5 mtr cable for Split type AC 1.5 ton / 2.0 ton / 2.5 ton complete all as specified and as directed
Supply Only Fuses for Split type AC 1.5 ton / 2.0 ton / 2.5 ton complete all as specified and as directed
Supplying and Fixing PVC flexible Conduit pipe 20mm dia medium grade including all accessories for drain out pipe complete all as specified and as directed
Supplying and Fixing inlet / outlet gas valves suitable for split AC 1.5 ton / 2.0 ton / 2.5 ton complete all as specified and as directed.
Material and Labour for servicing water coolers of 40 / 80 ltrs Capacity Complete with cleaning condenser coil with air blower, wet servicing of condensor coil unit with caustic soda etc, replacement of sheet metal screws wherever necessary applying oil in fan motor bushes checking and rectifying the wiring defects, proper setting of thermostat & other electrical/ Refrigerent controls, connecting up all connections and testing complete all as specified and as directed.
Material and Labour for servicing water coolers of 60 / 120 ltrs Capacity Complete with cleaning condenser coil with air blower, wet servicing of condensor coil unit with caustic soda etc, replacement of sheet metal screws wherever necessary applying oil in fan motor bushes checking and rectifying the wiring defects, proper setting of thermostat & other electrical/ Refrigerent controls, connecting up all connections and testing complete all as specified and as directed
Taking out burnt / unserviceable Sealed Compressor Unit from Water coolers 40 / 80 Ltrs per Hr Cooling capacity, Supply & replacement factory Sealed compressor unit, connecting refrigeration system after thoroughly flushing out the system and leak testing with CO2, vaccumising and gas charging with refrigerant gas, testing, re-installing in its original position/location connecting up all electrical connections, testing the complete unit complete all as specified and as directed. Notes:- (i) Sealed compressor unit shall be replaced with existing capacity/Make. (ii) Gas Charging shall be mesasured and paid separately under relavent item
Taking out burnt / unserviceable Sealed Compressor Unit from Water coolers 60 / 120 Ltrs per Hr Cooling capacity, Supply & replacement factory Sealed compressor unit, connecting refrigeration system after thoroughly flushing out the system and leak testing with CO2, vacuumising and gas charging with refrigerant gas, testing, re-installing in its original position/location connecting up all electrical connections, testing the complete unit complete all as specified and as directed. Notes:- (i) Sealed compressor unit shall be replaced with existing capacity/Make. (ii) Gas Charging shall be mesasured and paid separately under relavent item
Material and Labour for removing the Water cooler from position and arresting the Leakages in condenser coil by brazing etc complete for Water cooler 40 / 60 Ltrs per Hr cooling capacity complete all as specified and as directed
Taking out Unserviceable starting capacitor, Supplying & Fixing Starting capacitor suitable for Water cooler 40 Litres/Hr or 60 litres/Hr cooling capacitor complete all as specified and as directed
Taking out Unserviceable running capacitor, Supplying & Fixing running capacitor suitable for Water cooler 40 Litres/Hr or 60 litres/Hr cooling capacitor complete all as specified and as directed
Taking out existing unserviceable thermostat, Supplying & Fixing thermostat for Water cooler 40 Litres / Hr or 60 litres/ Hr cooling capacity complete all as specified and as directed
Taking out existing Unserviceable potential relay, Supplying & Fixing Potential relay of for Water cooler of 40Ltr/Hr or 60 Ltrs/Hr cooling capacity complete all as specified and as directed
Taking out Unserviceable OLP from Water cooler, Supplying & Fixing OLP suitable for Compressor complete all as specified and as directed
Taking out Unserviceble fan motor, Supplying & Fixing Fan motor (for Water Cooler Capacity 40 Ltrs/Hr or 60 Ltrs/Hr cooling capacity) complete all as specified and as directed
Material and Labour for taking out defective fan blade of Water Cooler of any make & size Supplying and Fixing new Fan blade of same size and design as existing complete all as specified and as directed
Taking Out defective PVC flexible connector, Supplying & Fixing heavy duty PVC flexible connection braided type 15mm dia and 450mm long with nuts/ washers on either end complete all as specified and as directed
Material and Labour for Servicing Refrigerators up to 185 Lts capacity complete with cleaning condenser coil with air blower, wet servicing of condenser coil unit with caustic soda etc, replacement of sheet metal screws wherever necessary, checking and rectifying the wiring defects, proper setting of thermostat & other electrical/ Refrigerent controls, connecting up all connections and testing complete all as specified and as directed
Material and labour for Servicing Refrigerators up to 185 - 400 Lts capacity complete with cleaning condenser coil with air blower, wet servicing of condenser coil unit with caustic soda etc, replacement of sheet metal screws wherever necessary, checking and rectifying the wiring defects, proper setting of thermostat & other electrical/ Refrigerent controls, connecting up all connections and testing complete all as specified and as directed
Taking Out Unserviceable / burntout Sealed Compressor Unit from Refrigerator, Supply & replacement Factory Sealed Compressor unit, connecting with copper piping by braziing & Copper tubing etc Complete Up to 185 Lts capacity complete all as specified and as directed. Notes:- (i) Sealed compressor unit shall be replaced with existing capacity/Make. (ii) Gas Charging shall be mesasured and paid separtely under relavent item
Taking Out Unserviceable / burntout Sealed Compressor Unit from Refrigerator, Supply & replacement Factory Sealed Compressor unit, connecting with copper piping by braziing & Copper tubing etc Complete Up to 185 - 400 Lts capacity complete all as specified and as directed. Notes:- (i) Sealed compressor unit shall be replaced with existing capacity/Make. (ii) Gas Charging shall be mesasured and paid separtely under relavent item
Removing the Refrigerator from position and arresting the Leakages in Condenser Coil by brazing etc. complete for refrigerator Up to 285 Ltrs complete all as specified and as directed
Taking Out existing Unserviceable Thermostat and Supplying and Fixing Thermostat for Refrigerator 165 Ltrs / 285 ltrs complete all as specified and as directed
Taking Out existing Unserviceable Box Type Relay, Supplying and Fixing Box type Relay for Refrigerators 165 Ltrs / 285 Ltrs complete all as specified and as directed
Taking Out existing Unserviceable OLP, Supplying and Fixing OLP for Refrigerator 165 Ltrs / 285 ltrs complete all as specified and as directed
Supply and Fixing in repairs Metal clad switch socket double pole and neutral enclosure with a two pin and earth plug and socket complete with One Single pole MCB SP 20 to 32 Amps and fixed concealed in walls complete all as specified and as directed.
Pumping down the Compressor before dismantling inner and outer units disconnecting electric connections also without any damage to existing system, reinstalling of inner and outer units in new locations Complete with brackets and civil works (making holes in wall) complete finishing as required, assembling of inner & outer units including connection of suction and discharge pipes, testing connection etc with topping up refrigerant gas as required to maintaining pressure complete all as specified and as directed
Material and labour for servicing Deep freezer upto 400 Lts capacity complete with cleaning condenser coil with air blower, wet servicing of condenser coil unit with caustic soda etc, replacement of sheet metal screws wherever necessary, checking and rectifying the wiring defects, proper setting of thermostat & other electrical/ Refrigerent controls, connecting up all connections and testing complete all as specified and as directed
Taking down of old u/s AC manager and Supply & fix AC load manager with built in programme for on/off of 2 Nos of 1.5 TR/2 TR capacity split type Acs suitable for operating on single phase 230 volts complete all as specified and as directed
Supply and fix push cock brass chromium plated complete all as specified and as directed
S & F Stainless steel tray for water cooler complete all as specified and as directed
JM Engineering
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .