Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.8 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹46.6 L+₹75,065 (1.64%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹47.0 L+₹1.2 L (2.60%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹49.9 L+₹4.1 L (8.85%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L4₹49.9 L+₹4.1 L (8.85%)Rejected-AOC | L4 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
22 Feb 2021, 6:00 pmClosed
Bangalore
GARRISON ENGINEER NORTH BANGALORE T 64 MEANEE LINES MEG AND CENTRE BANGALORE 560042
REPAIRS TO ROOF CHAJJA LEAKAGE SEEPAGE REPAIRS REPLACEMENT OF INTERNAL WIRING ELECTRICAL FITTINGS FIXTURES RENEWAL OF BLDG EARTHING AND OTHER CONNECTED ITEMS IN PRTC 106 INF BN OTHER ARMY AREAS IN THE AOR OF AGE B R NORTH UNDER
2021_MES_411429_1
8201
Open Tender
Civil Works
Item Rate
60 days
Bangalore
Class D Category a(i) b(i)
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER NORTH BANGALORE
₹90,000
Yes
27 Feb 2021
6 Feb 2021
23 Feb 2021
6 Feb 2021
22 Feb 2021
15 Feb 2021
6 Feb 2021 - 13 Feb 2021
Amount
NOTE FOR SL ITEM NO. 1.01 TO 1.52 and 2.01 to 2.045 :- It may be noted that work is of urgent nature, shall be completed with in two months and no extension of time will be granted for any reason what so ever.
B/R WORKS
Demolition of cement concrete of any description and in any position not otherwise specifically provided for and disposal of rubbish outside MD land, complete all as specified and as directed.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
Dismantling of Asbestos cement / GI (corrugated,semi corrugated, etc.) sheets in roof coverings complete all as specified and directed.
Dismantling of wooden timber fillets, rails, posts, rafters, purlins etc not exceeding 40 sq.cm in section all as specified and as directed.
Dismantling of timber scantlings in any position unframed work 40sq.cm and over in section all specified and as directed.
Plain Cement Concrete as in foundation filling and mass concrete, type D-2, (1:4:8), using 40 mm graded stone aggregate complete all as specified and as directed.
Plain Cement Concrete (1:11/2:3), type A-1 using 20mm graded stone aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
Steel formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter for rough finished flat surfaces of concrete complete all as specified and as directed.
Rolled Mild steel work as in flats, wind ties of grade Fe-410-0 or Fe-310-0 for roof including drilling holes, securing bolts etc and similar works complete all as specified and as directed.
Rolled mild steel work as in tubular poles/columns etc., including special shaped washers etc., complete using ERW or induction butt weld tubes conforming to IS 1161-1979 Gde St-240 complete all as specified and as directed.
Rolled mild steel work as in plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachmen with riveted, bolted or welded attachment conforming to Fe 410-0 or Fe 310-0 complete all as specified and as directed.
Rolled mild steel work as in tubular trusses, purlins etc., including special shaped washers etc., complete using ERW or induction butt weld tubes conforming to IS 1161-1979 Gde St-240 complete all as pecified and as directed.
Rolled mild steel framed work such as in grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed.
Second class hard wood as in clean sawn timber scantlings in unframed work 40sq.cm and over in section all specified and as directed.
Rolled mild steel joist, channel, angle or tee sections grade Fe 410-W Gde E-250 quality-A, fixed independently, with out connecting plates etc., (cut to ordinary lengths) complete all as specified and as directed.
Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall fixed with self tapping screws as specifed and as directed.
All as per Sl Item No 1.16 above but plain sheet for ridge.
E grid suspended false ceiling grid system of size 600mm x 600mm with main runner 32x24x0.6mm cross Tee 25x24 x 0.6mm and wall angle 22.2x22.2x0.5mm, ceiling suspended with 3mm dia GI wire hangers fixed with steel dash fastener, butterfly clips, hold down clips etc (main runner, cross Tee & wall angle of MS galvanised with PPPCGS) including 4mm thick HPSC self textured design pre primered non asbestos fibre cement building board fixed to false ceiling including one coat of oil bound emulsin distember over a coat of primer and dismantling of existing false ceiling with fillets of any type complete all as specified and as directed.
Plain Cement Concrete, (1:2;4), type B-1, 40mm thick using 20mm graded stone aggregate including finishing cement concrete surface even and rough to receive finishing coats complete all as specified and as directed.
Rendering 15mm thick over PCC roof padding concrete in CM (1:4) mixed with approved water proofing compound all as specified and as directed. NOTE:- Liquid water proofing compound shall be measured and paid separately.
Complete removal of existing roof treatment (tarfelt), removing rubbish to a distance n.exc 50m, complete all as specified and as directed.
Providing roof treatment by applying bitumen primer @ 0.27kg/sqm, providing 3mm thick APP modified water proofing membrane weighing not less than 3.8 kg/sqm reinforced with non woven polyester matt weighing not less than 180gm/sqm, having softening point not less than 140 centigrade, having tensile strength of 650 N/sq.cm in longitudinal and transverse directions, the reinforced tearing strength of 180N by torch application with minimum 10cm side overlap and 15cm end lap applying a coat of blown grade hot bitumen VG-10 over the membrane @ 1.2kg/sqm, top of membrane shall than be finished with solar reflective bituminous aluminium paint @0.10kg/sqm all as specified and as directed.
Taking down chowkat or frames with shutters (without taking of shutter from the frame) not exc. 1.5 sqm each all as specified and as directed
Steel windows of box type, with frame of 80 x 60mm and 1.25mm profile sheet with box type shutters consisting of inside glazed shutter and out side gauged shutter with steel handle, telephonic peg stay complete with guard bars of 08 Nos with 10 x 10mm mild steel square guard bars in equal spacing, devotailed or welded all as per TD Drg No. 539 sheet 1/3 to 3/3 including filling the frame with PCC (1:3:6) type C0 using 12.5mm graded stone aggregate and one coat of red oxide primer all as specified and directed. NOTE :- (i) PCC in frame, 4 mm thick sheet glass pane and galvanised wire cloth 0.56mm dia 1.18 aperture will be included in the quoted rate. (ii) Any brick work or concrete surface damaged during the process of work shall be repaired by contractor. (iii) The unit rate quoted shall deemed to be include the cost of scaffolding/staging etc as required at site.
Steel ventilators top hung shutter including peg stay, glass and steel wire cloth, guard bars etc. all as per TD drawing-539 sheet 1/3 to 3/3 complete with glazing bars all as specified and as directed.
Demolition of brick work /stone masonry/pcc block masonry built in cement mortar of any description all as specified and directed.
Precast cement concrete block masonry with solid blocks PCC 1:3:6, type C1 exc 10cm in width and setting in CM 1:6 complete all as specified and directed
Taking down cement plaster on brick / stone / concrete surface including wall tiling or terrazo finish and hacking out joints hacking for key scrubbing down with water etc and removing debris to outside MD land complete all as specified and directed.
15mm thick rendering on brick or concrete surface in cement mortar 1:6 and finishing the surface with even and smooth without using extra cement complete all as specified and directed.
15mm thick rendering on fairfaces of brick work or concrete surfaces in cement mortar (1:4) mixed with WPC, finishing plastered surface even and smooth without using extra cement complete all as specified and directed. NOTE :- WPC will be measured and paid separately.
Rendering 5 mm thick on ceiling /RCC surfaces in cement mortar (1:3), finished plastered surface even and smooth without using extra cement complete all as specified and directed.
Preparation of newly plastered ceiling surfaces of any description and applying three coats of white wash complete all as specified and directed.
Preparation of new plaster surfaces of any description over 10 cm in width or girth not otherwise described and applying two coats of oil bound emulsion distemper over a coat of alkali reistant primer and over a coat of putty finshed to smooth surfaces on wall complete all as specified and directed.
Preparation of newly plastered surfaces of walls and applying two coats of cement based paint over a coat of primer all as specified and as directed.
Supply only integral liquid water proofing compound all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbishh off the the premises all as specified and as directed.
Non skid ceramic coloured tiles 7-8mm thick (square / rectangular) area of each tile exceeding 0.11 Sqm but n.exc 0.18 Sqm as in floors set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15mm thick screed bed in CM (1:4) complete all as specified and as directed.
Matt finish ceramic coloured tiles 7-8mm thick (square / rectangular) area of each tile exceeding 0.18 Sqm but n.exc 0.36 Sqm as in floors set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15mm thick screed bed in CM (1:4) complete all as specified and as directed.
Glazed coloured ceramic tiles as in vertical surfaces 350 x 250x 7 mm/ 450 x 350 x 7 mm/ 300x450x7 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over rendering 10mm thick in CM (1:4) backing coat on fair faces of brick work or concrete surfaces complete all as specified and as directed.
Vitrified light coloured tiles of approved shade and pattern, of size 600mmx600mmx9-10mm thick joint less as in floor/skirting set and jointed in cement slurry, over and including 15mm thick screed in cement mortar (1:4) pointed. in white cement with pigment to match the colour of tiles complete all as specified and as directed.
15mm dia Bib taps, cast copper chromium plated alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule fixed in repairs complete all as specified and as directed.
Bib taps standard of PTMT any colour screwed for iron pipe suitable for 15mm dia fixed in repairs all as directed.
32mm dia, 800mm long corrugated waste pipe fixed in repairs complete all as specified and as directed.
Taking down existing bib taps, pillar taps, stop cock or angle valve of any size and re fixing in old or new position including replacing one nylon washer complete all as specified and as directed.
All as per Sl Item No : 1.43 here-in-before but replacing brass spindle.
Rotational moulded polythene water storage tank (cylindrical vertical with closed top) with ISI mark embosed on it, hoisted and fixed in position complete all as specified in SSR part I capacity of tank 500 ltrs capacity complete complete all as specified and as directed.
20mm dia Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed(Min weight 20mm-210 gms) all as specified and as directed.
PVC valveless, syphonic action type, flushing cistern, 10ltr capacity,low level, white, with inlet, ball valve, float and handle including brackets, connections to pipes and fixing of chain and pull, or lever, fixed in repairs complete all as specified and directed.
PVC connections 15mm dia size with PTMT nuts of length 450mm fixed in repairs all as specified and as directed.
Vitreous china wash basin, white, flat back size 630 x 450 mm excluding taps, chain, plug and porcelain stopper but including CI bracket. etc complete fixed in repairs complete all as specified and as directed.
Vitreous china white wash down water closet (pedestal pattern) including PVC sheet cover, brass chromium plated health faucet and connection to drain or outgoing pipe and to flushing pipe anti-syphonage pipe etc, fixed as in repairs complete all as specified and as directed.
Preparation of new or previously untreated steel and iron surfaces of any description not other wise described over 10cm width or girth and applying two coats of synthetic enamel over a coat of red oxide primer, complete all as specified and directed.
E/M WORKS
Taking down carefully aluminium/ copper wiring/power point wiring (light, fan,call bell socket or power circuits) complete and making good the disturbed surface of walls, ceiling etc including painting with same colour of the back ground complete all as specified and as directed.
Point wiring complete with 1.5 sq.mm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and including PVC casing and caping ISI marked including accessories surface type wiring including MS terminal boxes fabricated with 1.6 mm thick MS sheet concealed mounted/ on walls with laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., including provision of 1.5 sq.mm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed. (a) One light point controlled by one switch.
(b) One fan point controlled by one switch/regulator.
(c) One light point controlled by 2 way switch.
(d) One 3 pin socket out let 5 Amps on independent board.
(e) one bell/buzzer point controlled by bell push.
(f) one 3 pin socket out let 5 A on same board.
Point wiring complete with 2.5 sq.mm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and including PVC casing and caping ISI marked including accessories surface type run on walls/ ceiling including MS terminal boxes fabricated with 1.6 mm thick MS sheet surface mounted/ concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., including provision of 2.5 sq.mm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed. NOTE FOR SL ITEM No. 2.02 to 2.08 :- (i) The earth wire for the points in the same circuit can be looped from point to point. (ii) Earth wire shall be taken inside the conduit. (iii) Cost of terminal box is deemed to be included in the item rate quoted for point wiring. (iv) Cost of a circuit of any length of cable from DB to any switch/ socket board to be included in point wiring.
LED batten fittings, 18 watts, 6000K, (4 feet long), suitable for indoor applications wall mounted with extruded aluminium heat shink provision, efficient heat dissipation and integrated electronic driver, industrial batten type, powder coated top cover, connector block , lamp etc., complete all accessories internally pre wired all as per Bajaj, Cat No.BCLAB 18 WH LED P / Halonix Cat No. HLB-03-18-CW-AL or techno commercially equivalent makes specified in PS including including taking out old fittings and connecting up twin core twisted flexible copper conductor cable all as specified and directed.
LED batten fittings, 20 watts, 6000K, (4 feet long), suitable for indoor applications wall mounted with extruded aluminium heat shink provision, efficient heat dissipation and integrated electronic driver, industrial batten type, powder coated top cover, connector block , lamp etc., complete all accessories internally pre wired all as per Bajaj, Cat No.BCLAB 20 WH LED P / Halonix Cat No. HLB-03-20-CW-AL or techno commercially equivalent makes specified in PS including including taking out old fittings and connecting up twin core twisted flexible copper conductor cable all as specified and directed.
LED tube light fittings, 10 watts, 6000K, (2 feet long), wall mounted with extruded aluminium heat sink provision, efficient heat dissipation and integrated electronic driver, industrial batten type, powder coated top cover, with bipin holders,connector block, lamp etc., complete all accessories internally pre wired all as per Havells Cat No. LHEWEBP7IN1W010 / Bajaj Cat No. BCLSB 10 WH or techno commercially equivalent makes specified in PS including connecting up with twin core twisted flexible copper conductor cable all as specified and directed.
LED batten suitable for indoor applications 5 Watts, with polycarbonate housing and integrated LED channel with white arcylic cover complete with all accessories internally pre wired all as per Bajaj, Cat No.BCLSB 05 WH or techno commercially equivalent makes specified in PS including connecting up with twin core twisted flexible copper conductor cable including taking down the existing fitting all as specified and directed.
2' x 2' Recess mounted LED Luminaire 36 Watts white powder coated CRCA housing with LEDs seamless front frame with flate white high transmission arcylic cover complete with all accessories all including taking out old fittings complete all as per Bajaj Cat No : BZRSQL 36W GZi WH or techno commercially equivalent makes specified in PS all as specified and as directed.
2' x 2' surface mounted LED Luminaire 36 Watts white powder coated CRCA housing with LEDs seamless front frame with flate white high transmission arcylic cover complete with all accessories including taking out old fittings complete all as per Bajaj Cat No : BZSSQL 36W LED WHi or techno commercially equivalent makes specified in PS all as specified and as directed.
Surface mounting LED 4' x1' luminaire 36 Watts white, deep drawn CRCA aluminium housing with high power LEDs, seamless front frame with flat white high transmission arcylic cover complete with accessories including taking out old fittings all as per Bajaj Cat No. BZSSLL 36W LED WH or techno commercially equivalent makes specified in PS complete all as as specified and as directed.
1' x 1' surface mounted LED Luminaire 24 Watts white powder coated CRCA housing with LEDs seamless front frame with flate white high transmission arcylic cover complete with all accessories including taking out old fittings all as per Bajaj Cat No. BBZSSQL 24W LED WHi or techno commercially equivalent makes specified in PS complete all as as specified and as directed.
Bulkhead LED luminaries 10 watt energy efficient solution for upgrading convertional with IP 65 including taking out old fittings all as per Bajaj Cat No. BIBWP10WLED or techno commercially equivalent makes specified in PS complete all as as specified and as directed.
Modular switch 1 way, 6 Amps, one module including taking down the existing complete all as specified and as directed.
Modular switch 1 way 16 Amps, one module including taking down the existing complete all as specified and as directed.
Modular socket, 6 Amps, 2/3 pin combined, two module including taking down the existing complete all as specified and as directed.
Modular socket, 6 Amps / 16 Amps, 2/3 pin combined, two module including taking down the existing complete all as specified and as directed.
Modular fan regulator, five stepped, 120 Watt, 2 Module including taking down the existing complete all as specified and as directed.
Modular bell push flush type 5 Amps, one module including taking down the existing complete all as specified and as directed.
Switch Piano, flush type, 5 Amps, 240 Volts two pole with ISI marked including taking down the existing complete all as specified and as directed.
Angle holder PVC/polycarbonate type including taking down the existing complete all as specified and as directed.
Switch Piano, flush type, 5 Amps, 240 Volts single pole with ISI marked including taking down the existing complete all as specified and as directed.
Switch socket combination 3 & 2 pin, 5 Amps, 240 Volts, flush type multipurpose controlled by one switch including taking down the existing complete all as specified and as directed.
Switch socket combination 2 in 1, 3 pin and 2 pin, 5 and 15 Amps flush type, universal including taking down the existing complete all as specified and as directed.
Bell push Piano, flush type, 5 Amps, 240 Volts single pole with ISI marked iCeiling rose, surface bakelite type, 65 x 50 mm, 2 to 3 terminals all as specified and as directed.
MCB single pole and neutral 240 Volts, 5 to 40 Amps including taking down the existing un serviceable MCB complete all as specified and as directed.
MCB single pole 240 Volts, 5 to 40 Amps including taking down the existing un serviceable MCB complete all as specified and as directed.
MCB TPN 415 volts 63 Amps including taking down the existing complete as specified and as directed.
MCB DB, SPN 8 ways, 240 Volts with 200 Amps rated busbar, double door for housing MCBs including taking down the existing un serviceable MCB DB complete all as specified and as directed.
MCB DB, TPN 4 ways, 240 Volts with 200 Amps rated busbar, double door for housing MCBs including taking down the existing un serviceable MCB DB complete all as specified and as directed.
Ceiling rose, surface bakelite type, 65 x 50 mm, 2 to 3 terminals including taking down the existing complete all as specified and as directed.
Stepped type electronic fan regulator flush type including taking down the existing complete all as specified and as directed.
Ding Dong bell, AC 230 volts, single pole including taking down the existing complete all as specified and as directed.
Sub main wiring with two runs of single core 4 sq.mm, 1100 volts grade multi stranded copper conductor cable along with one run of 4 sq.mm PVC insulated single core multistranded copper conductor cable as earth continuity conductor drawn through and including non rigid PVC conduit medium grade of suitable size including taking down the existing complete all as specified and as directed. NOTE: Two runs of 4 sq.mm cable, one run of 4 sq.mm earth continuity conductor and one run of PVC conduit shall be measured as one unit for payment purpose.
Sub main wiring with two runs of single core 6 sq.mm, 1100 volts grade multi stranded copper conductor cable along with one run of 6 sq.mm PVC insulated single core multistranded copper conductor cable as earth continuity conductor drawn through and including non rigid PVC conduit medium grade of suitable size cincluding taking down the existing complete all as specified and as directed. NOTE: Two runs of 6 sq.mm cable, one run of 6 sq.mm earth continuity conductor and one run of PVC conduit shall be measured as one unit for payment purpose.
Earthing complete with galvanised steel plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge not less than 1.5 m below ground level connected to earth lead by GI wire 4 mm dia by means of bolts nuts, check nuts, washers made out of galvanised iron connected to main switch all as shown in elect plate No 3 of MES SSR Part -I includingn excavation and earth work in any type of soil,funnel, 20 mm dia light grade GI watering pipe with chamber of PCC 1:3:6 type C1 40mm thick of size 450mm x450mm (1:2:4) type B1 for cover slab reinforced with 8mm dia TMT bars 10cm c/c both ways and with 6mm MS hook etc complete all as specified including testing on completion all as specified and directed.
30 Watt LED building security light fitting with pressure die cast housing along with prismatic polycarbonate difuser with IP 66 protection including taking out old fittings all as per Bajaj Cat No.:- ENXT P 30L WH SY PC SD or techno commercially equivalent makes specifed in PS complete all as specified and as directed.
Brackets made out of GI tubing medium grade 40 mm bore , approx length 1.5 m long including MS clamps made out of MS flat iron 25 x 6 mm , nuts, bolts, washers etc and including applying two coats of aluminum paint over a coat of red oxide primer before fixing including removing the old existing GI bracket from building complete all as specified and directed.
Sheet metal enclosure single pole and neutral with a two pin earth plug and socket with one single pole MCB 20 Amps, 230 Volts AC complete all as specifeid and directed.
MCCB, 4 pole, 100 Amps,16 KA with adjustable thermal setting 415 Volts 50Hz including complete connections with incoming cable and out going cable with suitable thimbles and crimping the thimbles with crimping tools insulating the naked portion with insulation tape including taking down the existing unserviceable MCCBs complete all as specified and as directed.
MCCB, 4 pole, 250 Amps, 25 KA with adjustable thermal setting 415 Volts 50Hz including complete connections with incoming cable and out going cable with suitable thimbles and crimping the thimbles with crimping tools insulating the naked portion with insulation tape including taking down the existing unserviceable MCCBs complete all as specified and as directed.
M.S.Trading Company
SREE VARU ELECTRICALS
Auromirra Enterprises
Atom Engineers and Builders
K. VENKATESH NAIDU
Suneetha Engineers and Contractors
UNIVERSAL ENGINEERING
H S S ENGINEERS AND CONTRACTORS
Sathya Sri Construction
S S BUILDERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .