Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.7 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹29.3 L+₹1.4 L (4.98%)Rejected-Finance | L2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | L3₹30.0 L+₹2.1 L (7.54%)Rejected-Finance | L3 | Rejected-Finance BEING NOT LOWEST | |
| 4 | Rejected-Technical NO 1073 K R SQUARE 15TH CROSS 30TH MAIN BANASHANKARI 2ND STAGE BANGALORE KARNATAKA 560070 | BENGALURU URBAN | KARNATAKA | 560070 | - | Rejected-Technical REJECT DUE TO NON SUBMISSION OF DOCUMENT AS PER NIT CONDITION |
| Sl No | Description | Qty | Unit | YOU SEE CONSTRUCTION L3 | Hindustan Power Corporation L1 | ALLAHABAD ENTERPRISES L2 |
|---|---|---|---|---|---|---|
| 1.00 | Supply, Installation, Testing & Commissioning Earth electrode Cu Bonded rod 17.2 mm dia X 3000 mm - 250 micron UL Listed 467 and IEC - 62561-2: 17.2/OD SS Clamp Both side; Eco safe Based environment friendly backfill and suitable clamp, Back-fill earthing enhancing compound should strictly be a Eco Safe Carbon based conductive concrete type which has a resistivity of less than 0.12 Ohm Mtr as per Clause 14.5D of IEEE:80 standard. Back-fill compound should be electronically conductive (Like in metals) and should not depend on moisture for conduction. Back-fill compound should be environment friendly, should solidify when mixed with water and set like concrete and should not leach / diffuse into the ground. Back-fill compound shall not be mixed with any soil while pouring in the bore hole. Type) - 25 kg as per IS/IEC - 62561-7, IEEE -80 and IS 3043 : Eco friendly rust proof heavy duty weather proof polyethylene Earth pit chamber with following dimension : 254 mm dia (top). 330 mm dia (Bottom) & 260 mm (height) as per, resistance value below 1 ohm as per IS:3043:2018, Type test report for earth electrode as per IEC 62561-2 ( coating test,Adhesion test, Bend test, Environment test, Electrical resistivity, Tensile test etc ) Type test report for backfill compound as per IEC 62561-7(Corrosion test, Leach test, Sulphur test,Resistivity test etc
Note:-
(i) Earthing work is to be carried out by OEM i.e. JEF TECHNO SOLUTIONS PVT LTD/ OBE Betterman/ ERICO/ FURSE/ INGESCO/ JMVLPS/True Power/ Roksna India Pvt Ltd.
(ii) The contractor shall be required to submit a MOU with OEM for the same and it will be an essential requirement in Technical Evaluation stage. The tenderer shall required to upload MOU with OEM otherwise bids shall not be qualify for opening of finance bid, MOU from autorised dealers of OEM shall not be accepted.
(iii) In case less than 1.0 Ohm result has not achieved at site, the contractor is responsible to done grid system to achieve the desired result and each earthing shall be measured seperately.
(iv) Cost of additional earth continuty conductor which were required for grid connection as per site requirment shall be measured and paid seperately. | 20 | Each Job | 19,000 ₹3,80,000 | 21,500 ₹4,30,000 | 18,500 ₹3,70,000 Lowest |
| 2.00 | Testing & Survey of Earth Soil Resistivity(P) as per Cl. 10.3 of IS 3043:2018, BS 7430,JEEE 80,IEEE 81 using CDEGS software for earthing, CURRENT DENSITY AT THE SURFACE OF EARTH ELECTRODE/STRIP, Fault Current dissipation by grid conductor, Calculation for earth grid resistance as per BS 7430-1985- CI: 8.5, Overall resistance of earthing electrodes [R1], Overall Resistance of Earth strip [R2] below grid, Overall resistance of Earth Grid[R]=(R1xR2)/(R1+R2) complete all as specified and directed. | 4 | Each Job | 26,000 ₹1,04,000 | 48,000 ₹1,92,000 | 25,500 ₹1,02,000 Lowest |
| 3.00 | Supply, Installation, Testing & Commissioning 10 mm dia steel conductor with 100-micron CU bonding tested as per IEC 62561-2 conducted in the Govt. aggregated third party laboratories to meet the requirement of IS/IEC 62305 complete all as specified and directed. | 400 | RM | 1,300 ₹5,20,000 | 980 ₹3,92,000 Lowest | 1,250 ₹5,00,000 |
| 4.00 | Supply, Installation, Testing & Commissioning Exothermic Joint for straight connection of 10 mm dia conductor as per IEEE 837 Standard complete all as specified and directed. | 50 | Each | 2,040 ₹1,02,000 | 3,250 ₹1,62,500 | 1,980 ₹99,000 Lowest |
| 5.00 | Supply, Installation, Testing & Commissioning Exothermic Joint for Cross connection of 10 mm dia conductor as per IEEE 837 Standard complete all as specified and directed. | 50 | Each | 2,270 ₹1,13,500 | 4,500 ₹2,25,000 | 2,250 ₹1,12,500 Lowest |
| 6.00 | Supply, Installation, Testing & Commissioning Exothermic Joint for T connection of 10 mm dia conductor as per IEEE 837 Standard complete all as specified and directed. | 50 | Each | 2,055 ₹1,02,750 Lowest | 4,950 ₹2,47,500 | 2,075 ₹1,03,750 |
| 7.00 | Spply, Installation, Testing & Commissioning Equipotential SS bus Bar as per IS/EC 62305 complete all as specified and directed. | 50 | Each | 4,980 ₹2,49,000 | 6,200 ₹3,10,000 | 4,800 ₹2,40,000 Lowest |
| 8.00 | Supply, Installation, Testing & Commissioning flat strip round connectors as per IS/IEC 62305 complete all as specified and directed. | 50 | Each | 1,275 ₹63,750 | 1,300 ₹65,000 | 1,250 ₹62,500 Lowest |
| 9.00 | M&L for construction of earth pit chamber of internal dimensions of 300x300x250mm in brick masonry built in PCC 1:3:6 type C-1 using 20mm graded stone aggregate for earth pit with pre cast RCC cover slab (1:2:4) type B-1 using 20mm graded stone aggregate 40mm thick reinforced with 8mm dia TMT bars 3 Nos both way with 12mm dia MS round bar handle complete all as specified and directed. | 20 | Each Job | 2,200 ₹44,000 | 3,500 ₹70,000 | 2,160 ₹43,200 Lowest |
| 10.00 | S&F of earth continuity conductor or main earthing lead 32mmx6mm copper strip/earth lead, laid in trench, fixed on walls or any other position including jointing by tinned copper/brass nuts, bolts and washers in addition to brazing at every joint, complete all as specified and directed. | 230 | RM | 5,300 ₹12,19,000 | 2,650 ₹6,09,500 Lowest | 5,225 ₹12,01,750 |
Tender Value
₹29.4 L
EMD Value
₹58,800
Closing Date
1 Jan 2026, 6:00 pmClosed
GE AF Gorakhpur
Gorakhpur
PROVN OF EARTHING INFRASTRUCTURE FOR MPR AT AF STN UNDER GE AF GORAKHPUR.
2025_MES_743415_1
9396/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE AF Gorakhpur
Class D cat b (i)
8 documents required · 8 mandatory
₹500
Yes
GE AF Gorakhpur
₹58,800
Yes
4 Feb 2026
12 Dec 2025
7 Jan 2026
12 Dec 2025
1 Jan 2026
26 Dec 2025
12 Dec 2025 - 25 Dec 2025
Select, Excess (+), Less (-) Less (-)
Tender Inviting Authority: Garrison Engineer (AF) Gorakhpur
Name of Work: Provn of earthing infrastructure for MPR at AF Stn Gkp under GE AF GORAKHPUR.
Contract No.: GE(AF)/GKP/E-84 OF 2025-26 File No. 9395/E8 Serial Page No.15
Name of the Bidder/ Bidding Firm / Company :
Sl. No. gegkp Item Code / Make Quantity Units Estimated Rate in Rs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e. DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit, if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes in Rs. P TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words
1 Supply, Installation, Testing & Commissioning Earth electrode Cu Bonded rod 17.2 mm dia X 3000 mm - 250 micron UL Listed 467 and IEC - 62561-2: 17.2/OD SS Clamp Both side; Eco safe Based environment friendly backfill and suitable clamp, Back-fill earthing enhancing compound should strictly be a Eco Safe Carbon based conductive concrete type which has a resistivity of less than 0.12 Ohm Mtr as per Clause 14.5D of IEEE:80 standard. Back-fill compound should be electronically conductive (Like in metals) and should not depend on moisture for conduction. Back-fill compound should be environment friendly, should solidify when mixed with water and set like concrete and should not leach / diffuse into the ground. Back-fill compound shall not be mixed with any soil while pouring in the bore hole. Type) - 25 kg as per IS/IEC - 62561-7, IEEE -80 and IS 3043 : Eco friendly rust proof heavy duty weather proof polyethylene Earth pit chamber with following dimension : 254 mm dia (top). 330 mm dia (Bottom) & 260 mm (height) as per, resistance value below 1 ohm as per IS:3043:2018, Type test report for earth electrode as per IEC 62561-2 ( coating test,Adhesion test, Bend test, Environment test, Electrical resistivity, Tensile test etc ) Type test report for backfill compound as per IEC 62561-7(Corrosion test, Leach test, Sulphur test,Resistivity test etc Note:- (i) Earthing work is to be carried out by OEM i.e. JEF TECHNO SOLUTIONS PVT LTD/ OBE Betterman/ ERICO/ FURSE/ INGESCO/ JMVLPS/True Power/ Roksna India Pvt Ltd. (ii) The contractor shall be required to submit a MOU with OEM for the same and it will be an essential requirement in Technical Evaluation stage. The tenderer shall required to upload MOU with OEM otherwise bids shall not be qualify for opening of finance bid, MOU from autorised dealers of OEM shall not be accepted. (iii) In case less than 1.0 Ohm result has not achieved at site, the contractor is responsible to done grid system to achieve the desired result and each earthing shall be measured seperately. (iv) Cost of additional earth continuty conductor which were required for grid connection as per site requirment shall be measured and paid seperately. 20 Each Job 13 Excess(+) Full Conversion INR 2 Construction of chamber for 100mm sluices valve item3 10 Nos
2 Testing & Survey of Earth Soil Resistivity(P) as per Cl. 10.3 of IS 3043:2018, BS 7430,JEEE 80,IEEE 81 using CDEGS software for earthing, CURRENT DENSITY AT THE SURFACE OF EARTH ELECTRODE/STRIP, Fault Current dissipation by grid conductor, Calculation for earth grid resistance as per BS 7430-1985- CI: 8.5, Overall resistance of earthing electrodes [R1], Overall Resistance of Earth strip [R2] below grid, Overall resistance of Earth Grid[R]=(R1xR2)/(R1+R2) complete all as specified and directed. 4 Each Job 10 Excess(+) Full Conversion INR 1.02 Construction of chamber for 100mm sluice plates item2 213 Nos
3 Supply, Installation, Testing & Commissioning 10 mm dia steel conductor with 100-micron CU bonding tested as per IEC 62561-2 conducted in the Govt. aggregated third party laboratories to meet the requirement of IS/IEC 62305 complete all as specified and directed. 400 RM 10 Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
4 Supply, Installation, Testing & Commissioning Exothermic Joint for straight connection of 10 mm dia conductor as per IEEE 837 Standard complete all as specified and directed. 50 Each 10 Excess(+) Full Conversion INR 1.02 Construction of chamber for 100mm sluice plates item2 213 Nos
5 Supply, Installation, Testing & Commissioning Exothermic Joint for Cross connection of 10 mm dia conductor as per IEEE 837 Standard complete all as specified and directed. 50 Each 10 Excess(+) Full Conversion INR 2 Construction of chamber for 100mm sluices valve item3 10 Nos
6 Supply, Installation, Testing & Commissioning Exothermic Joint for T connection of 10 mm dia conductor as per IEEE 837 Standard complete all as specified and directed. 50 Each 10 Excess(+) Full Conversion INR 3 Supplying, Conveying and fixing spls. Including ea item4 10 Nos
7 Spply, Installation, Testing & Commissioning Equipotential SS bus Bar as per IS/EC 62305 complete all as specified and directed. 50 Each 10 Excess(+) Full Conversion INR 1.02 Construction of chamber for 100mm sluice plates item2 213 Nos
8 Supply, Installation, Testing & Commissioning flat strip round connectors as per IS/IEC 62305 complete all as specified and directed. 50 Each 10 Excess(+) Full Conversion INR 1.01 Supplying, Conveying and fixing spls. Including eart item1 123.223 Nos
9 M&L for construction of earth pit chamber of internal dimensions of 300x300x250mm in brick masonry built in PCC 1:3:6 type C-1 using 20mm graded stone aggregate for earth pit with pre cast RCC cover slab (1:2:4) type B-1 using 20mm graded stone aggregate 40mm thick reinforced with 8mm dia TMT bars 3 Nos both way with 12mm dia MS round bar handle complete all as specified and directed. Each Job 44 Excess(+) Full Conversion INR 1.02 Construction of chamber for 100mm sluice plates item2 213 Nos
10 S&F of earth continuity conductor or main earthing lead 32mmx6mm copper strip/earth lead, laid in trench, fixed on walls or any other position including jointing by tinned copper/brass nuts, bolts and washers in addition to brazing at every joint, complete all as specified and directed. 230 RM 45 Excess(+) Full Conversion INR 1.02 Construction of chamber for 100mm sluice plates item2 213 Nos
11 S&F HRFR single core copper conductor of size 35 Sqmm from equipment to copper strip as specified and directed. RM 51 Excess(+) Full Conversion INR 1.02 Construction of chamber for 100mm sluice plates item2 213 Nos
12 M&L for Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed. Each 52 Excess(+) Full Conversion INR 1.02 Construction of chamber for 100mm sluice plates item2 213 Nos
13 S&F of High density polyethylene pipes (HDPE) of size 40mm dia laid in trenches as well as fixed to wall with provisioning of suitable sizes of MS clamps (1 mtr apart), screws etc for passing of lightning arrester strips complete all as specified and directed. 160 RM 70 Excess(+) Full Conversion INR 1.02 Construction of chamber for 100mm sluice plates item2 213 Nos
14 S&F of porcelain insulators for fixing roof/down conductor including fixing of screws etc as specifed and directed. 54 Each 79 Excess(+) Full Conversion INR 1.02 Construction of chamber for 100mm sluice plates item2 213 Nos
15 M&L for making MS Sheet as per existing shape/size not exceeding 200mmx300mm width and writing following details in Capital letters form of 25mm height and 10mm width on single side of the board in black colour with red or yellow colour back ground as required at site complete shall be embedded in PCC foundation with 50x50x6mm angle post properly complete all as specified and directed with following:- (a)Type of earthing-GI or Copper or Chemical (b)Earthing for which equipment is being connected (e.g. lightning arrester) (c)Number of earth pit and the total number of particular type of earthing for that Bldg/Equipment (e.g. Number-01 Lightning Arrester pit out of 04 Nos pit of same- "LA-01/04") Each Job 80 Excess(+) Full Conversion INR 1.02 Construction of chamber for 100mm sluice plates item2 213 Nos
Total in Figures 4 Construction of chamber for 100mm sluice plates item5 10 Nos
Quoted Rate in Figures Select
Quoted Rate in Words
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.65 MB
BOQ_832426.xls
BOQ • 0.48 MB
tenderca84.pdf
Tender Documents • 1.93 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .