| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.7 LAccepted-AOC 0 | ₹46.7 L Quoted ₹48.0 L | L1 | Accepted-AOC AOC |
| 2 | L2₹49.3 LRejected-Finance MEGHDOOT HOTTEL MALL ROAD RANIKHET UTTARAKHAND | ₹49.3 L | L2 | Rejected-Finance HIGHER THAN L1 BIDDER |
| 3 | L3₹52.1 LRejected-Finance | ₹52.1 L | L3 | Rejected-Finance HIGHER THAN L1 BIDDER |
| 4 | L4₹53.7 LRejected-Finance | ₹53.7 L | L4 | Rejected-Finance HIGHER THAN L1 BIDDER |
| 5 | L5₹55.5 LRejected-Finance 212 B 8 PARDEWANPUR LAL BANGLA KANPUR 208007 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208007 | ₹55.5 L | L5 | Rejected-Finance HIGHER THAN L1 BIDDER |
| Sl No | Description | Qty | Unit | A S ENTERPRISES L1 | SHREE BHAGWATI ENTERPRISES L3 | R N KHARWAR & SONS L2 | santosh electronics L5 | SAKSHAM SUPPLIERS BUILDERS L4 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Attending complaints to checking & replacing the existing defective electrical items for continuous electric supply incl carrying out minor repair as reqd to make the item fuctional & replacing fuse, small pieces of copper wire, copper cable as suitable size at site, insulation tape roll, etc. Attending minor repairs such as testing, connectings fittings, nuts, bolts, screws, etc to emergent complaints i.e. no light, earth leakage, short circuit, neutral break in mains/sub mains/internal circuits of existings electrical systems of main buildings/blocks and making continuous electric supply incl carrying out minor repairs to make system in order/functional with insulation tape roll, copper thimbles, glands, earthing, wire as required at site complete all as specicifed and directed.
NOTE :1. This item is applicable only where no store is required.
2. The site for attending complaints are COD Estate, ASC Depot, ME line, VRG line, Offr Qtr Napier road, Harding road contractor should provide minimum on trademen (electrician) for such site to attend the complaint in all working days between 0830 hrs to 1700 hrs incl holiday and sunday.
3. Contractor shall insure the security passes for his staff, to be obtained from concern auth for attending complaints
4 The contractor will ensure that the electricians with necessary toolm bag shall always remain present at complaint cell to attend the complaints.
5. A recovery of Rs 500/- for not attending the complaints upto 04 hrs and 04 hrs Rs 1000/- shall be recovered from the contractor.
6. The complaint slip, register & other connected documents will be provided by the contractor without any extra cost.
7. Proper date wise record of complaints received & rectified by the contractor and the same may be asked for verifiaction at the time of payment of each RAR/Bill. | 800 | Each Job | 30 ₹24,000 | 50 ₹40,000 | 30 ₹24,000 | 200 ₹1.6 L | 110 ₹88,000 |
| 2.00 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting, bell, bell push etc and making good disturbed surfaces of walls, floor to match with existing specification complete all as specified and directed. | 790 | Per Point | 2 ₹1,580 | 5 ₹3,950 | 4 ₹3,160 | 20 ₹15,800 | 8 ₹6,320 |
| 3.00 | M&L for point wiring for one light point/fan/bell point controlled by one switch with 1.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable FRLS with proper colour coding and 1.5 sqmm PVC insulated unsheathed copper conductor single core multistranded cable (green colour) as earth lead in and including concealed non metalic rigid PVC conduit medium grade size 25mm dia with all fittings (ISI Marked) controlled by one switch including CI/MS sunk box of required size & as directed & 3 mm thick plastic laminated sheet, including cutting chases to wall making good the disturbed surfaces to match with the existing specification complete all as specified and directed. | 180 | Per Point | 300 ₹54,000 | 320 ₹57,600 | 305 ₹54,900 | 485 ₹87,300 | 320 ₹57,600 |
| 4.00 | All as per item No 3 above but upto ceiling height and on surface at ceiling complete all as specified and directed. | 40 | Per Point | 300 ₹12,000 | 320 ₹12,800 | 305 ₹12,200 | 535 ₹21,400 | 340 ₹13,600 |
| 5.00 | All as per item No 3 above but in existing conduit complete all as specified and directed. | 125 | Per Point | 300 ₹37,500 | 320 ₹40,000 | 305 ₹38,125 | 500 ₹62,500 | 310 ₹38,750 |
| 6.00 | All as per item No 3 above but for one 3 pin 15 Amps socket outlet independent with 2.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable and 2.5 sqmm PVC insulated unsheathed copper conductor single core cable (green colour) as earth lead in and incl conduit complete all as specified and directed. | 50 | Per Point | 320 ₹16,000 | 350 ₹17,500 | 345 ₹17,250 | 625 ₹31,250 | 380 ₹19,000 |
| 7.00 | All as per item No 3 above but for one 3 pin 15 Amps socket outlet independent with 2.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable and 2.5 sqmm PVC insulated unsheathed copper conductor single core cable (green colour) as earth lead in existing conduit complete all as specified and directed. | 50 | Per Point | 380 ₹19,000 | 400 ₹20,000 | 395 ₹19,750 | 610 ₹30,500 | 370 ₹18,500 |
| 8.00 | All as per item No 3 above but for one 3 pin 5A socket outlet independent controlled by one switch complete all as specified and directed. | 50 | Per Point | 380 ₹19,000 | 400 ₹20,000 | 395 ₹19,750 | 550 ₹27,500 | 310 ₹15,500 |
| 9.00 | All as per item No 3 above but for one 3 pin 5A socket outlet independent controlled by one switch in existing conduit complete all as specified and directed. | 50 | Per Point | 300 ₹15,000 | 350 ₹17,500 | 305 ₹15,250 | 530 ₹26,500 | 310 ₹15,500 |
| 10.00 | All as per item No 3 above but for one 5A socket outlet on the same board controlled by one switch complete all as specified and directed. | 30 | Per Point | 60 ₹1,800 | 90 ₹2,700 | 60 ₹1,800 | 200 ₹6,000 | 120 ₹3,600 |
Updated dates
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
27 Nov 2025, 6:00 pmClosed
LT COL VISHAL BHURIA
GE I Kanpur Cariappa Road Cantt Kanpur 208004
COMPREHENSIVE MAINT AND PETTY REPAIR AND INTERNAL ELECTRIFICATION FITTING AND FIXTURE AND ALL CONNECTED ITEMS AT COD INSIDE AND OUTSIDE UNDER GE (I) KANPUR
2025_MES_727930_2
GE(I)/KAN/T-48 OF 2025-26
Open Tender
Electrical and Maintenance Works
180 days
KANPUR
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE(I) KANPUR
₹90,000
Yes
18 Feb 2026
6 Nov 2025
4 Dec 2025
6 Nov 2025
27 Nov 2025
13 Nov 2025
Amount
Attending complaints to checking & replacing the existing defective electrical items for continuous electric supply incl carrying out minor repair as reqd to make the item fuctional & replacing fuse, small pieces of copper wire, copper cable as suitable size at site, insulation tape roll, etc. Attending minor repairs such as testing, connectings fittings, nuts, bolts, screws, etc to emergent complaints i.e. no light, earth leakage, short circuit, neutral break in mains/sub mains/internal circuits of existings electrical systems of main buildings/blocks and making continuous electric supply incl carrying out minor repairs to make system in order/functional with insulation tape roll, copper thimbles, glands, earthing, wire as required at site complete all as specicifed and directed. NOTE :1. This item is applicable only where no store is required. 2. The site for attending complaints are COD Estate, ASC Depot, ME line, VRG line, Offr Qtr Napier road, Harding road contractor should provide minimum on trademen (electrician) for such site to attend the complaint in all working days between 0830 hrs to 1700 hrs incl holiday and sunday. 3. Contractor shall insure the security passes for his staff, to be obtained from concern auth for attending complaints 4 The contractor will ensure that the electricians with necessary toolm bag shall always remain present at complaint cell to attend the complaints. 5. A recovery of Rs 500/- for not attending the complaints upto 04 hrs and 04 hrs Rs 1000/- shall be recovered from the contractor. 6. The complaint slip, register & other connected documents will be provided by the contractor without any extra cost. 7. Proper date wise record of complaints received & rectified by the contractor and the same may be asked for verifiaction at the time of payment of each RAR/Bill.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting, bell, bell push etc and making good disturbed surfaces of walls, floor to match with existing specification complete all as specified and directed.
M&L for point wiring for one light point/fan/bell point controlled by one switch with 1.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable FRLS with proper colour coding and 1.5 sqmm PVC insulated unsheathed copper conductor single core multistranded cable (green colour) as earth lead in and including concealed non metalic rigid PVC conduit medium grade size 25mm dia with all fittings (ISI Marked) controlled by one switch including CI/MS sunk box of required size & as directed & 3 mm thick plastic laminated sheet, including cutting chases to wall making good the disturbed surfaces to match with the existing specification complete all as specified and directed.
All as per item No 3 above but upto ceiling height and on surface at ceiling complete all as specified and directed.
All as per item No 3 above but in existing conduit complete all as specified and directed.
All as per item No 3 above but for one 3 pin 15 Amps socket outlet independent with 2.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable and 2.5 sqmm PVC insulated unsheathed copper conductor single core cable (green colour) as earth lead in and incl conduit complete all as specified and directed.
All as per item No 3 above but for one 3 pin 15 Amps socket outlet independent with 2.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable and 2.5 sqmm PVC insulated unsheathed copper conductor single core cable (green colour) as earth lead in existing conduit complete all as specified and directed.
All as per item No 3 above but for one 3 pin 5A socket outlet independent controlled by one switch complete all as specified and directed.
All as per item No 3 above but for one 3 pin 5A socket outlet independent controlled by one switch in existing conduit complete all as specified and directed.
All as per item No 3 above but for one 5A socket outlet on the same board controlled by one switch complete all as specified and directed.
All as per item No 3 above but for one 5A socket outlet on the same board controlled by one switch in existing conduit complete all as specified and directed.
All as per item No 3 above but for one light point controlled by 2 nos two way switches complete all as specified and directed.
All as per item No 3 above but for one light point controlled by 2 nos two way switches in existing conduit complete all as specified and directed.
All as per item No 3 above but for one light/fan/bell point including pressed steel terminal modular boxes of appropriate size and top cover with suitable size of modular plate with all accessories complete all as specified and directed.
All as per item No 3 above but for one socket outlet 5 amps on independent board including pressed steel terminal modular boxes of appropriate size and top cover with suitable size of modular plate with all accessories complete all as specified and directed.
All as per item No 3 above but for one socket outlet 5 amps on same board including pressed steel terminal modular boxes of appropriate size and top cover with suitable size of modular plate with all accessories complete all as specified and directed.
All as per item No 3 above but for one light point controlled by two, two way switches including pressed steel terminal modular boxes of appropriate size and top cover with suitable size of modular plate with all accessories complete all as specified and directed.
All as per item No 3 above but for one 3 pin 15 Amps socket outlet independent with 2.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable and 2.5 sqmm PVC insulated unsheathed copper conductor single core cable (green colour) as earth lead in and including pressed steel terminal modular boxes of appropriate size and top cover with suitable size of modular plate with all accessories complete all as specified and directed.
M&L in replacement for submain wiring with four single core PVC insulated flexible copper conductor multistranded cable (FRLS) of size 4 Sqmm with proper colour coding and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 4 Sqmm as earth lead in & including concealed PVC conduit medium grade 32mm dia cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification all as required at site complete all as specified and directed.
All as per item No 19 above but in existing concealed conduit complete all as specified and directed.
M&L in replacement for submain wiring with four single core PVC insulated flexible copper conductor multistranded cable (FRLS) of size 10 Sqmm with proper colour coding and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 10 Sqmm as earth lead in & including concealed PVC conduit medium grade 32mm dia cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification all as required at site complete all as specified and directed.
All as per item No 21 above but for cable of size 1.5 sqmm and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 1.5 Sqmm as earth lead in but in existing recess existing recess PVC conduit complete all as specified and directed.
All as per item No 21 above but for cable of size 2.5 sqmm and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 2.5 Sqmm as earth lead in but in existing recess PVC conduit complete all as specified and directed.
All as per item No 21 above but for cable of size 6 sqmm and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 6 Sqmm as earth lead in & including concealed PVC conduit complete all as specified and directed.
All as per item No 21 above but for cable of size 6 sqmm and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 6 Sqmm in existing concealed conduit with earth wire 4 sqmm complete all as specified and directed.
M&L for switch piano flush button single pole one way 5/6 amps 240 volts complete all as specified and directed.
S&F switch piano flush button single pole one way 15/16 amps 230 Volts complete all as specified and directed.
M&L for switch piano flush button single pole two way 5 amps 240 volts complete all as specified and directed.
M&L for bell push flush button single pole one way 5 amps 240 volts complete all as specified and directed.
M&L for socket 5 amps 5 pin flush type, 230 volts complete all as specified and directed.
M&L for socket out let, 6 pin 5 and 15 amps multi purpose 2 in 1 flush type, 230 volts complete all as specified and directed.
M&L for ceiling rose surface bakelite 3 terminals complete all as specified and directed.
M&L for bell electric heahy duty Ding Dong type 230 volts single pole complete and all as specified complete all as specified and directed.
S&F Lamp holder insulated body with back plate for dome batten fittings complete all as specified and directed.
Supply and fixing in replacement step type hum free electronic fan regulator suitable to control speed of fan from 0 to 100% and connecting electrically all as required complete all as specified and directed.
M&L for switch modular type single pole one way 1 module 6 amps 240 volts complete all as specified and directed.
S&F switch modular type one way 1 module 16 amps 230 Volts complete all as specified and directed.
M&L for switch modular type two way 1 module 6 amps 240 volts complete all as specified and directed.
M&L for bell push modular type 1 module one way 6 amps 240 volts complete all as specified and directed.
M&L for socket 6 amps modular type 2/3 pin combined 2 module, 230 volts complete all as specified and directed.
M&L for socket modular type , 2/3 pin, 6 and 16 amps combined 2 module, 230 volts complete all as specified and directed.
S&F electronic fan regulator modular type one way 1 module 230 Volts complete all as specified and directed.
Supply & fix in concealed or fixed on wall of rigid non-metallic PVC conduit of size 25 mm dia, exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc make of conduit complete all as specified and directed.
S&F in replacement of wall mounted LED light fittings 20/22 watt, 6500K/4000K/3000K, extruded aluminium heat sink provided for efficient heat dissipation and integrated electronic driver complete connecting electrically complete all as specified and directed.
Supply and fix LED alumimium batten luminaire surface mounted, 2 feet system wattage of 10 Watts with lifetime of not less than 50000 burning hours with 70% of its initial lumen maintained and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixe complete all as specified and directed.
S&F in repair LED Alumimium housing with inbuilt smart motion sensor based auto dimmable batten luminaire surface mounted, 2 feet system wattage of 10 Watts and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixe complete all as specified and directed.
S&F Emergency LED Batten gets automatically switched on during a power cut and runs effectively upto 4 hours having rated wattage 20 Watt Lumen (AC) 2000 Lumen (DC) 500 PF> .9 Colour temperature 6500 K CRI>80 protection class IP 20 complete all as specified & directed.
S&F Emergency LED lamp gets automatically switched on during a power cut and runs effectively upto 3 hours having rated wattage 12 Watt Lumen (AC) 1200 Lumen (DC) 450 PF> .9 Colour temperature 6500 K CRI>80 protection class IP 20 complete all as specified and directed.
S&F in replacement of LED Bulb 9 W complete all as specified and directed.
S&F in replacement of LED T- Bulb 10/12 W cool day white complete all as specified and directed.
S&F in replacement of LED light fitting recess mounted min 36 Watt, 2' x 2' with all accessories suitable for amstrong/grid/POP ceiling with integrated electronic driver and making electrical connection properly complete all as specified and directed.
S&F in replacement of LED light fitting Surface mounted min 36 Watt, 2' x 2' with all accessories suitable for amstrong/grid/POP ceiling with integrated electronic driver and making electrical connection properly complete all as specified and directed.
Supply and fixing in replacement of 10W surface mounted IP65 Bulkhead with system efficiency of 100LM/Watt LED bulk head shall be made up of Die cast Aluminium housing for better heat decapitation. P.F>.95 with THD <10%,surge protection 4KV input voltage rane 150Vto 270V including connecting electricaly to ceiling rose using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm and complete all as specified and directed.
Supply and fix in replacement of High power LED street light 25 Watt IP 66 Energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP65 roadway luminaire with high power LEDs as light source and electronic driver incl suitable size service bracket fixed with clamps, nut, bolt and washer and electric connection with 1.5 Sqmm multistranded twin core alum cable PVC insulated complete all as specified and directed.
S&F in replacement Gate light fitting LED type 15 W with CCT not less than 6500K/3000K and IP 65 Protection ,230V recessed mounting mirror opticluminare with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size including wire and making connection with pole complete all as specified and directed.
Supply & fix in repair LED bollard light 8/9 w suitable for landscape lightening with high power LED as light source incl making PCC foundations fixing with reqd fasterners , making electrical connections complete all as specified and directed.
Supply and fix in repair energy saving surface mounting premium LED luminaries 11/12/14 watt suitable for corridor made out of CRCA metal housing and PPMA diffuser for elegant look, with surface mounting accessroes/module etc complete all as specified and directed. Note : Contractor will submit guarantee/warranty certificate from manufacturer.
S&F distribution board iron clad, double door with IP-43 1K-09 protection suitable for MCCB as incommer and MCB as outgoing 415 Volts 3 phase 50 C/s VTPN DB 4 way, complete with appropriate size copper bus bar and neutral link with one MCCB 3 pole 415 Volts 160 Amps rating with rupturing cap 16 kA of the same make as of distribution board & with MCBs of required size making connection with thimbles & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site complete all as specified and directed.
All as per item No 58 above but for VTPN DB 8 way with MCCB 160 Amps 4 pole 25 kA complete all as specified and directed.
Supply and fix sheet metal enclosure MCB distribution board, double door with IP-43 IK-09 protection with metal door single phase 240 volts 4 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed.
All as per item No 60 above but for 8 way complete all as specified and directed.
M&L for MCB single pole 240 volts 5 to 30 amps, with rupturing capacity 10 kA using thimbles of required size complete all as specified and directed.
M&L MCB single pole & neutral 240 volts 30 to 63 amps,with rupturing capacity 10 kA using thimbles of required size complete all as specified and directed.
S&F in replacement of MCCB 4 Pole 415 Volts 3 phase 100 Amps 16 kA, thermal magnetic release complete all as specified and directed.
S&F in replacement of MCCB 4 Pole 415 Volts 3 phase 125 Amps 16 kA, thermal magnetic release complete all as specified and directed.
S&F in replacement of service wire 10 Sqmm, 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor, twin core cable flat or circular complete all as specified and directed.
S&F in replacement of service wire 06 Sqmm, 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor, twin core cable flat or circular complete all as specified and directed.
S&F in replacement of service wire 04 Sqmm, 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor, twin core cable flat or circular complete all as specified and directed.
Supply & Fixing in replacement Exhaust fan iron body 200/250 mm sweep with fittings with suitable nut & bolts & connections to wall complete all as specified and directed.
Supply & Fixing in replacement Exhaust fan iron body 300 mm sweep with fittings with suitable nut & bolts & connections to wall complete all as specified and directed.
Supply & Fixing in replecement air ventilator/fresh air fan plastic body 200 mm sweep with fittings & connections to wall complete all as specified and directed.
M&L in replacement of earthing with galvanised iron earth plate electrode of size 600x600x6mm thick as earth electrode with top edge of the earth plate not less than 1.5mtr below ground level using GI wire 4mm dia as earth continuity conductor connected to earth plate by means of GI thimbles nuts bolts washers all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover in PCC 1:3:6 adequate quantity of charcoal dust and salt all around the erth plate, earth work in any type of soil remaing surplus excavated material all as required at site and specified in EP No 5 of SSR part I 1991 complete all as specified and directed.
Supply and fix in replacement cable PVC insulated unsheathed with flexible multistranded copper conductor of size 0.75 Sqmm complete all as specified and directed.
All as per item No 73 above but size 1.5 Sqmm and complete all as specified and directed.
All as per item No 73 above but size 2.5 Sqmm and complete all as specified and directed.
All as per item No 73 above but size 4 Sqmm and complete all as specified and directed.
All as per item No 73 above but size 6 Sqmm and complete all as specified and directed.
All as per item No 73 above but size 10 Sqmm and complete all as specified and directed.
Supply and fixing in replacement plug top 3 pin 16 amps AC 240 Volts and complete all as specified and directed.
Supply and fixing in replacement plug top 3 pin 6 amps AC 240 Volts and complete all as specified and directed.
Supply & fix in replacement hylem sheet cover 3 mm thick of size 7"x4" all as required at site including drilling holes for fixing screws and providing 4 Nos screws with washers for fixing the sheet to sunken box /wooden box and complete all as specified and directed .
All as per item No 81 above but of size 8"x10" and complete all as specified and directed .
All as per item No 81 above but of size 11"x9" and complete all as specified and directed .
All as per item No 81 above but of size 13"x11" and complete all as specified and directed .
S&F in repair sunken box size 7"x4" and making good disturbed surface to match with the existing surface of wall by applying putty and applying colour / white wash finish and complete all as specified and directed.
S&F in repair sunken box size 8"x10" and making good disturbed surface to match with the existing surface of wall by applying putty and applying colour / white wash finish complete all as specified and directed.
S&F in replacement of LED light fitting recess mounted 36 Watt, 1' x 4' with all accessories suitable for amstrong/grid/POP ceiling with integrated electronic driver and making electrical connection with making electrical connection with three core copper wire to ceiling rose properly and complete all as specified and directed.
S&F in repair switch socket combination 2 in 1, 3 pin, 5 Amp flush type universal with complete all as specified and directed.
S&F in Repair switch socket combination 2 in 1, 3 pin,15 Amp flush type universal with complete all as specified and directed.
S&F in repair Switch socket combination 2in 1, 5 A flush types complete all as specified and directed.
S&F in repair Switch socket combination 2in 1, 15 A flush types complete all as specified and directed.
S&F in repair Solar LED Pathway Lights bollard type Waterproof Outdoor Lighting Path Light IP65 ,For Garden (warm white/coolday white not less than 08W and hight not less tha 80 cm with high efficient LEDs including not less than 8W/5V MONOCRYSTALLINE SOLAR PANEL & HIGH BATTERY BACKUP suitable for 10 hrs working time And the light , automatically turns on the Light at night and turns off in the morning (dusk to dawn),need to make the switch on & off which makes this solar decorative with suitable pcc foundation and making all electric connection complete all as specified and directed.
S&F fullycast aluminium body finished with polyurethane paint bollard of length 730mm and circular base diameter of 245 mm and max diameter of leg of bollard 115 mm surmounted with fully cast aluminium body finished with PU Paint with acrylic window cover with B22 brass holder and 20 watt white/warm white Bulb all as required complete all as specified and directed. Note- Cost of foundation and fixing charges included in quoted unit rate.
S&F in replacement of of highway discreet LED ,PDC housing & internal LED driver, PC lens to provide better uniform distribution, IP-65 protection siutable for 60/80 watts with hanging suitable GI chain from truss to fiiting as required on site all assesories, Clamp ,nut bolts washer and connecting electrically with 3 core copper flexible wire of size 1.5 sqmm from ceiling rose to fitting complete all as specified and directed.
S&F in replacement of of highway discreet LED ,PDC housing & internal LED driver, PC lens to provide better uniform distribution, IP-65 protection siutable for 120/140 watts with hanging suitable GI chain from truss to fiiting as required on site all assesoriesi.e. Clamp ,nut bolts washer and connecting electrically with 3 core copper flexible wire of size 2.5 sqmm from ceiling rose to fitting complete all as specified and directed.
M&L in repair for sheet metal enclosure MCB distribution board single pole and neutral with a two pin and earth plug and socket 25 amps 240 volts, complete with one single pole MCB of 25 amps earthing and complete all as specified and directed .
M&L for opening the geyser and replacement of glass wool for insulation of geyser of 25 to 50 ltrs capacity of any make / type complete all as specified and directed.
S&F in repair of chromium plated flexible stainless steel connection with two brass adopter as per existing sample suitable for carrying hot / cold water, fixed one end at geyser inlet and other to outlet water supply point complete all as specified and directed.
S&F in repair of PVC flexible connection with two brass adopter as per existing sample suitable for carrying hot / cold water, fixed one end at geyser inlet and other to outlet water supply point complete all as specified and directed.
M&L for disconnecting, dismantling old u/s thermostat switch of geyser 25 to 50 ltrs capacity and replaced with new as per sample with temperature range adjustable from 25 to 90 degree centigrade, superior quality 20 Amps rating, 220 Volts AC supply as per sample complete all as specified and directed.
M&L for disconnecting, dismantling old u/s heating element of cap 2 kW and replaced with new and testing on completion complete all as specified and directed.
All as per item No 101 above but heating element of size 1.5 kW complete all as specified and directed.
M&L for dismantling old u/s syphon assembly of geyser 25 to 50 ltrs ltr capacity and replaced with new stainless steel syphon complete all as specified and directed.
S&F in repair of pressure release valve with inlet coupling of superior quality as approved complete all as specified and directed.
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated,ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.00, Air delivery minimum 210 CFM, 350 RPM (tolerance as per IS : 374( 2019), THD less than 10%, electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc complete all as specified and directed.
S&F for Metal exhaust AC, copper winded, Single Phase 450mm sweep 1400 RPM, with louvre complete all as specified and directed.
M&L for earth resistance test of all type of earthing of electrical & water supply installation or any spl eqpt or bldg earthing using digital earth resistance tester, the result of each earthing to be noted in a register duly signed by JE & AGE EM complete all as specified and directed. Note – Digital Earth resistance tester has to be provided by contractor
Supply & fix in replacement PVC insulated and PVC round sheathed 3 Core 1.5 sqmm multicore annealed copper conductor for voltage Grade 1100 volt conforming to IS 694:2010 complete all as specified and directed.
Supply & fix in replacement PVC insulated and PVC round sheathed 3 Core 2.5 sqmm multicore annealed copper conductor for voltage Grade 1100 volt conforming to IS 694:2010 complete all as specified and directed.
R N KHARWAR & SONS (BID ID -3476048)
SHREE BHAGWATI ENTERPRISES (BID ID -3484246)
SAKSHAM SUPPLIERS BUILDERS (BID ID -3484180)
santosh electronics (BID ID -3484261)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.24 MB
TenderdocumentsT48.pdf
Tender Documents • 0.99 MB
BOQ_824861.xls
BOQ • 0.69 MB
Download all tender documents and submit your bid