Tender Value
₹4.7 L
EMD Value
₹4,600
Closing Date
22 Sept 2022, 2:00 pmClosed
Chief Engineer/TTPS
O/o SE/MI/TTPS
ICHP Removal of carbon dust scale deposition on the electrical internal components and tightness checking of contactors in Control Desk at SSIII Station A conveyor system.
2022_EB_250373_1
CE/SE/MI/TTPS/135/2022-2023
Open Tender
Miscellaneous Works
Works
175 days
TTPS
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹4,600
30 Sept 2022
8 Sept 2022
23 Sept 2022
8 Sept 2022
22 Sept 2022
8 Sept 2022
Electrical mtce works in SS-III
Control Desk: Charges for cleaning of control desk by PLC panel. intermediate panel, operator console and UPS with battery bank using vacuum cleaner- cleaning with bush button ON/OFF element by using cleaning agent – tightness checking of terminal blocks and terminals complete in Coal Handling Control Room-III.
Pull chord switches: Charges for removal of carbon dust by using hand blower and cleaning the terminals with cleaning agent and tightness checking of pull chord switches for all running conveyors (27A-22Nos, 27B-22Nos, 26A-9Nos, 26B - 11Nos, 25A- 20Nos, 25B – 21Nos, 24A – 25Nos, 24B – 24Nos, 22 – 16Nos, 36A – 6Nos, 36B – 6Nos, 28A -10Nos – 28B – 16Nos) In one operation the above work should be carried out for 17 Nos Pull Chord switches.
Zero speed switch: Charges for removal of Carbon dust by using hand blowers and cleaning the terminals with cleaning agent and tightness checking of all Zero speed switches with probe for all conveyor 27A&B, 26A&B, 25A&B, 24A&B, 36A&B, 22, 28A & B. In one operation the above work should be carried out for 10Nos zero speed switches.
Local/ Remote switches: Charges for removal of Carbon dust by using hand blowers and cleaning the terminals with cleaning agent and tightness checking of all local/ Remote switches for 27A&B, 26A&B, 25A&B, 24A&B, 36A&B, 22, 28A&B. In one operation above work should be carried out for 10 Nos Local/Remote switches.
Intermediate panel and 10KVA UPS Charges for removal of carbon dust by using hand blowers and cleaning the intermediate panel and 10KVA UPS with battery terminal with cleaning agent and tightness checking of all terminal block.
PRINCE ELECTRICALS
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .