Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.3 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹36.3 L+₹2.3 L (6.73%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹36.6 L+₹2.6 L (7.74%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹37.6 L+₹3.7 L (10.7%)Rejected-Finance LOONPURIA GAON AT ROAD PANITOLA PO PANITOLA 786183 DIST TINSUKIA ASSAM | TINSUKIA | ASSAM | 786183 | L4 | Rejected-Finance L4 |
Tender Value
₹37.5 L
EMD Value
₹75,000
Closing Date
26 Nov 2020, 6:00 pmClosed
GE DINJAN
GE DINJAN, PANITOLA (PO), DIBRUGARH (DIST), ASSAM
SPL REPAIRS TO BLDG NO 4 BC AND SPL REPAIRS/REPLACEMENT OF CEILING FANS AGAINST BER INCLUDING CERTAIN B/R AND E/M REV/MINOR WORKS AT ALL OUTPOCKETS UNDER GE DINJAN
2020_MES_391081_1
C/8240/E8
Open Tender
Civil Works
Item Rate
180 days
DINJAN MIL STN
AS PER TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
GE DINJAN
₹75,000
Yes
12 Dec 2020
29 Oct 2020
28 Nov 2020
29 Oct 2020
26 Nov 2020
13 Nov 2020
Amount
Surface dressing not exceeding 15 cm deep in soft/loose soil complete all as specified and as directed.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and as directed.
Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m depth for foundation, etc., and getting out in soft loose soil complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 m wide and exceeding 1.5 m depth and not exceeding 3.0 m depth for foundation, etc., and getting out in soft loose soil complete all as specified and as directed.
Returning filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25cm in soft / loose soil complete all as specified and as directed.
Removing excavated material not exceeding 50m and depositing where directed at a alevel not exceeding 1.50 m above startig point complete all as specified and as directed.
Excavating in post holes (or similar holes) each not exceeding 0.5 Cum getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm watering and removing surplus soil to a distance not exceeding 50m and making good surface in soft/loose soil complete all as specified and as directed.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, in roof covering including ridges and keeping serviceable sheets in safe custody for reuse in the work complete all as specified and as directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) any thickness including cover fillets complete all as specified and as directed.
Dismantling of timber fillets, rails, posts, rafters, purlins etc. under 40 sqcm in section complete all as specified and as directed.
Dismantling timber scantlings 40 Sqcm and over in section, in any position complete all as specified and as directed.
Demolition of Plain cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thickness. (below or above ground level) complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and as directed.
Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water complete all as specified and as directed
Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc complete all as specified and as directed.
M&L for brick work with sub class 'B' bricks, straight or curved on plan exc 6m mean radius, built in cement mortar (1:6) complete all as specified and as directed.
M&L for brick work with sub class 'B' bricks, straight or curved on plan to any radius, built in cement mortar (1:4) as in half brick thick walls complete all as specified and as directed.
S&F for rolled mild steel work as in joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) conforming to Fe-290 (Gde E-165) complete all as specified and as directed.
S&F for steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S. 1161-1979 grade St-240 complete all as speicfied and as directed.
S&F for mild steel screw bolts of 11 to 15mm dia of shank (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exceeding 10cm and not exceeding 15cm long complete all as specified and as directed.
S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of profile as approved, any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F for pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges/valley gutter, fixed with self tapping screws complete all as specified and as directed. Note : Colour of ridge shall be same colour as that of sheet used for roof.
M&L for second class hardwood, scantlings, clean sawn, in unframed work complete all as specified and as directed.
S&F for 2nd class hard wood plain fillets, bull nosed, splayed, chamfered or rounded on one edge wrought, fixed with screws, cross sectional area exceeding 3 and not exceeding 6 Sqcm complete all as specified and as directed.
S&F for aluminium Anodised snap grid frame work of size 600mm x 600mm frame work for ceiling with aluminium tee section of size 23.5mm x 26.4mm x 1.4mm thick and aluminium angle section of size 36.5mm x 25mm x 1.4mm thick, for false ceiling including Hangers 4 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long including 4 mm thick non asbestos E-board (plain), HSPC fixed to frame including providing two coats of white wash complete all as specified and as directed. Make of E-Board : Eternit Everest/Lafarge Holcim/Armstrong or equivalent as approved by GE
Taking down chowkats or frame not exceeding 1.5 Sqm each with shutters (without taking off shutter from the frame) complete all as specified and as directed.
Taking down chowkats or frames, exceeding 1.5 but not exceeding 4 Sqm in each with shutter (without taking off shutter from the frame) complete all as specified and as directed.
S&F for well seasoned 2nd class hard wood plain, solid, straight chowkat and frames, wrought, framed, rebated on the solid rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed.
M&L for 35mm thick 2nd class hard wood Plain, framed, panelled shutters (any number of panels), with panels of 12mm thick veneered particle board medium density with commercial face veneers: supplied and fitted to chowkats complete all as specified and as directed, Sizes/section of members of shutters shall be as specified in SSR Part I, Section -8, clause 8.24 (a).
S&F for solid PVC door frames of sizes 50mm x 47mm made out of 5mm but single side prelam PVC sheet used instead of Plain colour PVC sheet & edges will be painted to match with prelam sheet reinforced with MS Square tube complete all as specified and as directed.
S&F for factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top and bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC "C" channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail , lock rail and bottom rail on either side and as gap insert for top rail and bottom rail , panelling of plain colour PVC sheet to be fitted in the MS framewelded/ sealed to the stiles and rails with suitable PVC sheet beading , and jointed together with solvent cement in the frame at site as per specification complete all as specified and as directed.
M&L for bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and as directed.
M&L for plain cement concrete (1:3:6) type C-1 (using 20mm graded stone aggregate) for embedding holdfast, bed block, cills, etc including necessary form work complete all as specified and as directed.
S&F for 100mm long butt hings medium weight cold rolled mild steel & fixed to chowkats all as specified and as directed.
S&F for aluminium alloy anodised sliding door bolt with hasp & staple (bolt type) and fixing clipes of sheet, cast or extruded sections and fixing bolts of extruded sections or cast aluminium alloy, length of bolt of 250 mm complete all as specified and as directed.
S&F for 150 mm long aluminium handle cast type anodised complete all as specified and as directed.
S&F for 100 mm long aluminium handles, cast type, anodised complete all as specified and as directed.
S&F for 150 mm long aluminium anodised, barrel tower bolts of extruded section complete all as specified and as directed.
S&F for 150mm floor door stopper of aluminium alloy body and tongue ,anodised ,with hard drawn steel spring fixed an floor as specified and as directed
S&F 150 mm long, Mild Steel, barrel tower bolts, stove enamelled black, with bright bolt complete all as specified and as directed.
S&F for galvanized mild steel wire cloth 0.56mm nominal dia of wire and average width of aperature 1.18mm and fixed with tinned tacks or galvanized wire staples complete all as specified and as directed.
S&F for steel ventilator with top hung shutter including projecting type hinges with steel handle and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and as directed.
S&F for 3 mm thick sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
M&L for preparation of new or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
M&L for preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide, zine chrome primer complete all as specified and as directed.
M&L for hardcore of gauge not exceeding 63 mm of broken stone or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
M&L for 100 mm thick plain cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in sub-base of flooring, etc complete all as specified and as directed.
M&L for 75 mm thick plain cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) as in plinth protection etc. finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand (1:2) complete all as specified and as directed.
M&L for 40 mm thick plain cement concrete (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in floors and finishing surfaces even and smooth with using extra cement complete all as specified and as directed.
M&L for non skid ceramic coloured tiles 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18sqm (400X400X7mm) in floor, over 15mm thick screed bed or bedding in cement mortar (1:6) on floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade as specified and as directed.
M&L for glazed ceramic coloured tiles of size 350X450X7 mm thick set and jointed in neat cement slurry and pointed in coloured cement as in vertical surfaces such as dado/skirting and facea of side bldg over and including 10mm thick backing coat in cement mortar (1:4) complete all as specified and as directed.
M&L for granite stone slab (of any type) 18 to 20 mm thick, machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including 15 mm thick screed bed or bedding in cement mortor (1:6) and cutting, polishing complete all as specified and as directed.
M&L for Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and as directed.
M&L for Chequered cement concrete tiles of size 25cm x 25cm x 22mm thick, as in floors etc, including 15 mm thick screed bed in cement mortar 1:4 and set & jointed in neat cement slurry and pointed in grey cement and pigments to match with the shade of tiles complete all as specified and as directed.
M&L for Plain cement concrete 1:2:4, type B-1, (using 20 mm graded stone aggregate) as in benching, coping, lintel upto 1.5m span cast in situ including necessary form work complete all as specified and as directed.
M&L for rendering 5 mm thick in cement mortor (1:3) on concrete surfaces as in ceilings (sunshed, chajja etc) and finishing surfaces even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:6) and finished surfaces even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:4) and finished the surfaces even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 15 mm thick in two layer (10mm and 5mm thick) on fair faces of brick work or concrete surfaces in cement mortar (1:4) mixed with integral water proofing compound at top 5mm thick layer weight of cement as per manufacturer's instructions and finished the surface even and smooth without using extra cement complete all as specified and as directed. Note : WPC shall be measured and paid separately against relevent item.
Supply only integral water proofing compound (ISI marked) complete all as specified and as directed.
M&L for preparing new surfaces of AC sheet/ceiling and applying three coats of white wash complete all as specified and as directed.
M&L for preparing newly plastered surfaces of walls etc. and applying three coats of white wash complete all as specified and as directed.
M&L for preparing old plastered surfaces of walls, etc and applying one coat of cement base paint complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and as directed.
Dismantling of rotational moulded polyethylene water tank of capacity exceeding 500 litres but not exceeding 1000 litres complete all as specified and as directed.
S&F for 500 litres capacity rotational moulded polyethylene water storage tanks bearing ISI marked (Cylindrical vertical with closed top), (bearing ISI marked) hoisted and fixed in position all as specified in SSR Part I and as directed.
S&F for 1000 litres capacity rotational moulded polyethylene water storage tanks bearing ISI marked (Cylindrical vertical with closed top), (bearing ISI marked) hoisted and fixed in position all as specified in SSR Part I and as directed.
S&F for 20 mm bore, Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe and fixed. (Minimum weight 15mm-142 gms/ 20mm-210 gms/25mm-455gms/40mm-690 gms) complete all as specified and as directed.
Taking up or down 15 mm bore steel tubing & connections and keeping serviceable pipes in safe custody for reuse in the work complete all as specified and as directed.
S&F for 15 mm bore, steel tubes, galvanised, medium grade with all fittings & fixed complete to wall and ceiling or laid in floors etc complete all as specified and as directed.
Taking up or down 20 mm bore steel tubing & connections and keeping serviceable pipes in safe custody for reuse in the work complete all as specified and as directed.
S&F for 20 mm bore, steel tubes, galvanised, medium grade with all fittings & fixed complete to wall and ceiling or laid in floors etc complete all as specified and as directed.
S&F for 20 mm dia gate valve cast copper alloy screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union complete all as specified and as directed.
S&F for 25 mm dia gate valve cast copper alloy screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union including taking down old one complete all as specified and as directed.
S&F for vitreous China wash basin, size 550x400mm, white, flat back, with PVC waste pipe, CP waste coupling, chain, plug and porcelean stopper & backets including cutting for and pinning in ends of brackets but excluding tap complete all as specified and as directed. Make : Cat No C0450 of Parryware/Hindware/Cera.
S&F for vitreous china urinal, half stall type, white (minimum) with grating and union for discharge pipe (excluding flushing cistern, flush pipe & waste pipe) including providing and fixing plugs, bedding urinal against wall in cement mortar (1:2) securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement complete complete as specified and as directed. Make : Cat No. C0575 of Parryware/Hindware/Cera.
S&F for vitreous china wash down water closet pan (pedestal pattern), white, including connection to outgoing drain and flushing pipe, anti syphonic pipe with seat and cover complete but excluding flushing cistern and flush pipe including making good damaged/disturbed surfaces complete all as specified and as directed.
S&F in repairs vitreous china squatting pan, 'Orissa' pattern, size 580x440 mm white with integral foot rest and 'P' or 'S' trap, including provision of lime concrete bedding, connection to trap and flushing pipe etc complete including making good to disturbed surfaces of floor to match with existing specifications complete all as specified and as directed.
S&F in repairs 10 litre capacity, PVC valve less syphonic action type, flushing cistern, low level, white, with inlet, ball valve, flush pipe, float and handle including brackets complete all as specified and as directed.
S&F in repairs, plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and as directed.
S&F in repairs, health faucet cast copper alloy with hook and hose not less than 1.2 metre long all as specified and as directed. Make : Parryware/Hindware/Cera
S&F in repairs 15mm bore PVC connection pipe 600mm long with PTMT nuts at both ends complete all as specified and as directed.
S&F in repairs 40 mm dia waste coupling of PTMT (Half or full threaded) (Minimum Weight 60 grams) complete all as specified and as directed.
S&F for 110 mm bore, UPVC (SWR), Type 'B', Soil waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors, etc complete all as specified and as directed.
S&F for 75 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floor/walls all as specified and as directed.
S&F for 110 mm bore, PVC (SWR) bends of any radius complete all as specified and as directed.
S&F for 110mm bore, PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and as directed.
S&F for 110 mm bore, PVC (SWR) reducers of any radius complete all as specified and as directed.
S&F for 110 mm bore, PVC (SWR) vent cowl complete all as specified and as directed.
S&F for 75 mm bore, PVC (SWR) floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and as directed.
S&F for 125 mm long, shower rose, brass chromium plated, swival type, complete all as specified and as directed.
S&F in repairs, 15 mm bore, Pillar taps, fancy type, cast copper alloy, chromium plated with capstan heads, screwed down high pressure with or without lettered 'Hot or Cold' with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed.
S&F in repairs, 15 mm bore, stop valves, cast copper alloy, chromium plated with long shank and cup, concealed type, screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and as directed.
S&F in reapirs, 15 mm bore, bib taps, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed.
S&F for towel Rail, 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden / plastic cleats (Minimum weight 190gms) complete all as specified and as directed.
S&F for 15 mm bore, bib taps, cast copper alloy, fancy type, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed.
S&F for 15 mm bore stop valves, cast copper alloy, fancy type, chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and as directed.
S&F for 15 mm bore, Pillar taps, fancy type, cast copper alloy, chromium plated with capstan heads, screwed down high pressure with or without lettered 'Hot or Cold' with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed.
S&F 15mm bore, PVC connection pipe 600mm long with PTMT nuts at both ends complete all as specified and as directed.
S&F 10 litre capacity, PVC valve less syphonic action type, flushing cistern, low level, white, with inlet, ball valve, flush pipe, float and handle including brackets complete all as specified and as directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for including cutting reinforcement to facilitate demolition of concrete, complete all as specified and as directed.
S&F for TMT steel bars 10 mm dia. and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and as directed.
S&F for TMT steel bars 6mm dia., and over cut to length, bend to shape required, including cranking, bending spirally as in nibs, stirrups, spacers and binders binding with and including providing mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for use and waste form work to sides of foundation, footings, bases of columns, plinth beams flat rough finished surfaces of concrete complete all as specified and as directed.
M&L for use and waste form work to sides of pillar, columns, etc. flat rough finished surfaces of concrete complete all as specified and as directed.
M&L for use and waste Form work to soffits and sides of lintel beam, roof beam, cantilevers, shelvers, for flat rough finished surfaces of concrete complete all as specified and as directed.
M&L for use and waste Form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizonal or sloping) for flat rough finished surfaces of concrete complete all as specified and as directed.
M&L for use and waste Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exceeding 10cm but not exceeding 20cm wide complete all as specified and as directed.
M&L for reinforced cement concrete (1:2:4) type B-1 (Using 20 mm graded stone aggregate) as in foundation including footing, plinth beams, bases of column etc complete all as specified and as directed.
M&L for reinforced cement concrete (1:2:4) type B-1 (Using 20 mm graded stone aggregate) as in columns, pillars, post and struts etc complete all as specified and as directed.
M&L for reinforced cement concrete (1:2:4) type B-1 (Using 20 mm graded stone aggregate) as in beam, lintel, cantilevers etc complete all as specified and as directed.
M&L for reinforced cement concrete (1:2:4) type B-1 (Using 20 mm graded stone aggregate) as in slabs supported on wall, roof beams etc complete all as specified and as directed.
M&L for precast reinforced cement concrete 1:2:4 type B1 (Using 20mm graded stone aggregate) as in cover slab of manholes, septic tank and the like, set in cement mortar (1:4) complete all as specified and as directed. Note : Reinforcement steel shall be measured and paid separately.
M&L for reinforced cement concrete (1:2:4) type B-1 (Using 20 mm graded stone aggregate) as in precast posts, fencing posts, straining or terminal posts, struts, etc for fencing, average sectional area exceeding 100 Sqcm and not exceeding 250 Sqcm with or without chamfered angles and flat, splayed, rounded or mitred tops and fixed in position complete all as specified and as directed.
M&L for loose filling of broken brick with aggregates of gauge 80 to 150 mm in soakage pits, soakage wells complete all as specified and as directed.
Opening the cover and cleaning of septic tanks properly by dewatering foul water and taking out night soil, excreta, sludge, etc from septic tank of any capacity and removing and carrying the same to a distance exc 100 m and n. exc 200 m, burried underground (minimum 30 cm below ground level) including necessary excavation and earthwork in soft/loose soil for pits, returning, filling in including sprinkling bleaching powder @ not less than 0.75 Kg/Sqm and dressing of surplus soil around to slope as required including refixing the cover in position complete all as specified and as directed. Note : (i) Volume of septic tank cleaned shall be measured for payment purpose. (ii) Depth of foul water and effluences including night soil, excreta, sludge, etc shall be measured before commencement of dewatering/cleaning of Septic tank in presence of Engr-in-Charge.
Demolition and breaking up to 150m bore drain pipes (SGSW/AC/RCC) set in cement mortar including cement concrete bedding and removal of debris/rubbles etc to a distance n.exc 50m complete all as specified and as cdirected. Note : Necessary axcavation and earth work shall be measured and paid seperately.
M&L for plain cement concrete (1:3:6) type C-2 (Using 40 mm graded stone aggragate) as in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 150 mm bore SGSW/RCC drain pipes complete all as specified and as directed.
M&L for Salt glazed stone ware drain pipes 150 mm bore, grade 'A' laid in trenches, jointed and tested complete all as specified and as directed.
Cutting into existing manholes for connecting new drain , making good to pipe rendering, cutting out existing bencing for and forming branch channel (1/2 round are 3/4 section) in cement concrete (1:2:4) type B1 smooth finished and reforming bencing as required for 200mm dia complete all as specified to as directed.
M&L for plain cement concrete (1:4:8) type D-2 (Using 40 mm graded stone aggregate) as in foundation, filling, and mass concrete, etc complete all as specified and as directed.
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
M&L for firebrick work as in linings to fire places, flues, incinerators, etc. (other than in chimney shafts), set, jointed and pointed in fireclay complete all as specified and as directed.
M&L for mild steel framed work such as grills, gratings, gates etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bar, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe-290 (Gde E-165) complete all as specified and as directed.
M&L for 1.5 mm thick mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and as directed.
Taking down carefully copper/ aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceilling roses, pendants, regulators, sockets light fitting etc for taking credit removing from site and making good disturbed surface of walls, floors etc complete all as specified and as directed.
M&L for concealed point wiring with 1.5 Sqmm (nominal area), FR PVC insulated, multistranded, single core unsheathed, copper conductor cables passing through and including PVC conduit with all fittings and accessories of PVC conduit (like Tee, bend etc.) complete with and including 1.5 Sqmm (nominal area) FR PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point terminated in metal flush box of suitable size for mounting switches, sockets, regulators etc including cutting chases and making good for one light/fan/bell/buzzer point controlled by one ,one way switches complete all as specified and as directed.
All as per item No. 129 above but wiring with cables of size 2.5 sqmm & cables of size 2.5 sqmm as continuous earth wire for one 5/15 Amps switch socket combination on Independent board complete all as specified and as directed.
S&F for switch piano, 5 Amp, single pole, flush type one way 230 volts bearing ISI marked complete all as specified and as directed.
S&F for switch socket combination 2 in 1, 5 pin, 5/16 Amps, flush type, 240 volts complete all as specified and as directed.
S&F for ceiling rose, 3 phase/PVC/polycarbonate, isolated body bearing ISI marked complete all as specified and as directed.
S&F for lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.
S&F for LED lamp 7 Watt complete all as specified and as directed. Make : Havells /Philips/Bajaj /Surya.
S&F for factory made board distribution (DB) Double Door in sheet steel enclosure with common bus bar at incomming end, SPN, 4 way, 240 Volts, 200 AMPS suitable for housing MCBs complete all as specified and as directed. Make : Cat part No: DHDPSHODRW16 of Havells/L&T/HPL.
S&F for factory made board distribution (DB) in sheet steel enclosure without bus bar, SPN, 2 way, 240 Volts suitable for housing MCBs complete all as specified and as directed.
M&L for PVC rectangular block for mounting DB, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 350x300x50mm deep complete all as specified and as directed.
S&F in repairs of MCB, 'C' series, SP, 240 Volts, 5 to 32 Amps, 'C' Series, 10KA capacity complete all as specified and as directed. Make : Cat No. 408587 to 408595 of Legrand/L&T/Havells.
S&F in repairs of MCB, SPN, 240 Volts, 5 to 32 Amps, 'C' series, 10KA capacity complete all as specified and as directed. Make : Cat No. 408609 to 408617 of Legrand/L&T/Havells.
S&F for 18 W surface and wall mounted LED Battern with polycarbonate housing and intigrated electronic driver complete all as specified and as directed. Make : Cat No: LUMILINEBS18WLED865SPCWH of Havells/HPL/Phillips/Bajaj.
S&F for 10 W LED, 240 volt, Energy saving new generation bulk head luminaire with opal diffuser including lamp and connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed. Make : Cat part No. LHEOAOP7UZ6W010 of Havells/HPL/Phillips/Bajaj.
S&Fin repairs of 25 W LED building security new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminum housing with hight power LED as lighting source and lens imbedded PC Cover having TOP OPENING seperate driver cmpartment with IP 65 protection and inpact resistance of IK07 complete all as specified and as directed. Make : Cat No. ENDURAPEARLSL25WSASYTOPC of Havells/HPL/Phillips/Bajaj.
S&F in repairs of street light bracket arm of length not less than 1.5 m made out of GI tubing, 25/32 mm bore, light grade fixed to pole, etc with suitable size flat iron clamp, nuts, bolts including painting with two coats of aluminium paint over a coat of red oxide, zinc chrome primer complete all as specified and as directed.
M&L for sub main wiring with two runs of 4 sqmm (Nominal area) single core cable FR PVC insulated, multistranded, unsheathed, copper conductor cables 1100 Volts grade drawn through PVC conduits/casing-caping of suitable size, fixed to wall/ceiling etc including 4 sqmm (nominal area) single core, FR PVC insulated, multistranded, unsheathed, copper conductor as earth wire and duly connected to common earth point including PVC conduits/casing-caping of suitable size complete all as specified and as directed. Note : PVC Conduits/Casing-caping, two run cables and one run of earth wire will be measured as one length.
M&L for sand cushioning and covering with clean dry sand in trenches for protection of under ground cables (below, above and around the cable laid in trenches) complete all as specified and as directed. Note : Thickness after punning down shall be measured for payment.
Supply and laying well burnt bricks, sub class 'B' bricks laid breath wise across the length of cable in trenches for protection of UG cables complete all as specified and as directed.
M&L for 40 mm bore, steel tubes, galvanised, light grade with all fittings, laid in floor/road crossing/drain etc as in UG cable protection complete to walls and ceilings or laid in floors complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated, armoured, 2 core, nominal cross sectional area of main conductor 6 Sqmm, stranded aluminium conductor, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI pipe including taking out old one complete all as specified and as directed. Note : Excvation and earth work shall be measured and paid seperately.
Supply, Installation, commissioning and testing of water cooler fully stainless steel body (Top lid, front top/ bottom, rear top, dip tray, side panel, etc.) and chiller tank (SS 304 food grade minimum 0.80mm thickness of stainless steel sheet), chiller tank with PUF insulation (Thickness not less than 0.6mm) including float ball valve of make Prayag/ Essco of suitable size as per manufactureres design & specification with non CFC Refrigerant (R-134A), energy efficient reciprocating compressor of make Emerson/ Tecumseh suitable for operation on single phase 230 volts, 50 Hz, AC supply, having storage capacity of 80 litres and nominal cooling capacity 40 litres per hour insulated top cover and fitted with hinges, gasket on all four sides, lock and key arrangement, full width single sheet moulded drain tray, Brass (Cr plated) push type double faucet, motor and condenser standing base made by stainless steel of minimum thickness 1.5mm with copper tube condenser not less than 0.50mm and minimum one year replacement warranty (Machine & Compressor) complete all as specified and as directed. Make : Model No. SS 4080 of USHA/Blue Star/ Voltas/LG.
S&F for voltage stabilizer for automatic operation with digital voltmeter to monitor in/out voltage with time delay and bypass switch, single phase, thermal overload protection, low & high voltage cut-off protection, LED indication, IC controlled, naturally air cooled indoor type and design for input variation between 170 volts to 250 volts with output output voltage stabilized at 230V with accuracy of +/- 2.5% and of capacity 1 KVA complete all as specified and directed Make : V-Guard/Servo/Godrej.
Supply, installation, commissioning & testing of BEE 5 star rated direct cool Refrigerator, single door type, with anti drip chiller tray, toughened glass shelves & base stand drawer, electric driven (single phase, 230V, 50 Hz, AC supply) of capacity not less than 190 Ltrs capacity with non CFC refrigerant inverter based compressor complete all as specified and as directed. Make : Model No. RD 1905 PTDI 53 GW BL of Godrej /Voltas/ Whirlpool/LG/Blue Star.
Supply, installing, testing and commissioning of Ceilling Fan, BEE stars rated suitable for Single Phase AC supply, earthing etc., 230 V, 50Hz, 1200 mm sweep, colour Opal white, power input 50 Watt, speed 370 RPM, 3 nos. blades, 100% copper winding, Power factor not less 0.9, Air delivery minimum 215 CMM, including all fixing accessories and insulation resistance more than 2 mega Ohm, including taking down carefully old unserviceable one and depositing to MES store complete all as specified and as directed. Make : Model No: Entrust-50 of Crompton/Havells/Bajaj/Khaitan.
Supply, installing, commissioning, testing of Deep Freezer, 310 ltrs capacity, 230 volt, 50 Hz, aesthetic design, D-cool technology based, energy efficient & Eco-friendly refrigerant with R600a, having hard top single door, with anti bacteria gasket & rotary compressor incl stucco Aluminium inner liner for improved hygiene, spring loaded hibges, with freezer temparature range <-18ºC complete all as specified and directed Make : Model No: GCHW310R6SXB Htop of Godrej /Blue Star/Samsung/LG/Voltas.
M&L for earthing complete with Galvanised steel earth plate electrode 600 mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers protected by 15mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, pre-cast RCC 1:2:4 type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia TMT steel bars @15cm centre to centre in both direction and 10mm dia MS handle of suitable size, charcoal or coke and salt in alternative layers,necessary earth work in soft/loose soil all as shown in Electrical Plate No 3 of MES Schedule Part I and testing complete all as specified and as directed.
M H KHAN
M/s CHAFIANG ARAN
M/S A K BROTHERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .