| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.3 LAccepted-AOC | L1 | Accepted-AOC being L1 | |
| 2 | L2₹42.2 L+₹1.9 L (4.65%)Rejected-Finance MB 58 JUNGLIGHAT KATHIR MARKETING SERVICE MB 58 JUNGLIGHAT NEAR TCI OFFICE SOUTH ANDAMAN ANDAMAN NICOBAR 744103 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹42.6 L+₹2.3 L (5.71%)Rejected-Finance ROOM NO 01 1ST FLOOR SIMA TRADING BUILDING SURVEY NO 268 GARACHARMA VILL SRI VIJAY PURAM 744105 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹49.8 L+₹9.4 L (23.4%)Rejected-Finance 1 PROP A R ELECTRICALS SCHOOL LINE MINNIE BAY JUNCTION PORT BLAIR SOUTH ANDAMAN ANDAMAN NICOBAR 744103 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹52.4 L+₹12.0 L (29.8%)Rejected-Finance 30 M A ROAD M A ROAD PHOENIX BAY SOUTH ANDAMAN ANDAMAN NICOBAR 744102 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744102 | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹38,000
EMD Value
₹76,000
Closing Date
17 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE minniebay
Junglighat PO Port Blair Andaman
REPAIR / MAINT OF LT DISTRIBUTION SYSTEM, OVERHEAD LINES, CABLE CHANGE OVER PANEL CONTROL SWITCHES AND CONNECTED ITEMS AT INS UTKROSH UNDER AGE E/M II AT GE MINNIEBAY, PORT BLAIR
2022_MES_570337_1
8205/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE Minniebay
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE Minniebay
₹76,000
Yes
9 Feb 2023
21 Dec 2022
20 Jan 2023
21 Dec 2022
17 Jan 2023
3 Jan 2023
Amount
Supply and fix in replacement of on load change over switch 415V, 4 pole, 125A complete all as specified and as directed by Engr-in-Charge
Supply and fix in replacement of on load change over switch 415V, 4 pole, 160A complete all as specified and as directed by Engr-in-Charge
Supply and fix in replacement of on load change over switch 415V, 4 pole, 200A complete all as specified and as directed by Engr-in-Charge
Supply and fix in replacement of on load change over switch 415V, 4 pole, 250A complete all as specified and as directed by Engr-in-Charge
Supply and fix in replacement of on load change over switch 415V, 4 pole, 320A complete all as specified and as directed by Engr-in-Charge
Supply and fix in replacement of on load change over switch 415V, 4 pole, 400A complete all as specified and as directed by Engr-in-Charge
Supply and fix in replacement MCCB, 415 volts, 4 pole adjustable thermal setting type 25 KA, 63A complete all as specified and as directed by Engr-in-Charge
Supply and fix in replacement MCCB, 415 volts, 4 pole adjustable thermal setting type 25 KA, 100A complete all as specified and as directed by Engr-in-Charge
Supply and fix in replacement MCCB, 415 volts, 4 pole adjustable thermal setting type 25 KA, 125A complete all as specified and as directed by Engr-in-Charge
Supply and fix in replacement MCCB, 415 volts, 4 pole adjustable thermal setting type 25 KA, 160A complete all as specified and as directed by Engr-in-Charge
Supply and fix in replacement MCCB, 415 volts, 4 pole adjustable thermal stting type 25 KA, 200A complete all as specified and as directed by Engr-in-Charge
Supply and fix in replacement MCCB, 415 volts, 4 pole adjustable thermal setting type 25 KA, 250A complete all as specified and as directed by Engr-in-Charge
Supply and fix in replacement MCCB, 415 volts, 4 pole adjustable thermal setting type 25 KA, 320A complete all as specified and as directed by Engr-in-Charge
Supply and fix in replacement MCCB, 415 volts, 4 pole adjustable thermal setting type 25 KA, 400A complete all as specified and as directed by Engr-in-Charge
Supply and fix in replacement MCB, 415 volts, 4 pole adjustable thermal setting type 10 KA, 100A complete all as specified and as directed by Engr-in-Charge
Supply and fix in replacement MCB, 415 volts, 4 pole adjustable thermal setting type 10 KA, 63A complete all as specified and as directed by Engr-in-Charge
Supply and fix in replacement MCB, 415 volts, 4 pole adjustable thermal setting type 10 KA, 40A complete all as specified and as directed by Engr-in-Charge
Supply and fix in replacement MCB, 220 volts, double pole adjustable thermal setting type 10 KA, 63A complete all as specified and as directed by Engr-in-Charge
Supply and fix in replacement MCB, 220 volts, double pole adjustable thermal setting type 10 KA, 32A complete all as specified and as directed by Engr-in-Charge
Supply and fix in replacement MCB, 220 volts, SP adjustable thermal setting type 10 KA, 40 to 63A complete all as specified and as directed by Engr-in-Charge
Supply and fix in replacement MCB, 220 volts, SP adjustable thermal setting type 10 KA, 6 to 32A complete all as specified and as directed by Engr-in-Charge
S&F in replacement straight through jointing kits heat shrinkable type LT UG XLPE cable heavy duty armoured sheathed and making the disturbed surface after relaying the cable for the following sizes :- Note : if the cable is laid in trenches, excavation, returning filling and removal of surplus soil shall be measured and paid separately under relevent item of this Schedule.
16 to 25 Sqmm 3.5 core
35 to 70 Sqmm 3.5 core
95 to 150 Sqmm 3.5 core
185 to 240 Sqmm 3.5 core
300 to 40 Sqmm 3.5 core
Supplying and laying in replacement of GI tubing medium grade for cable protection in trenches/duct/fixing to pole/wall or in such similar position of following size all as specified and directed:- Note : if the cable is laid in trenches, excavation, returning filling and removal of surplus soil shall be measured and paid separately under relevent item of this Schedule.
100 mm dia
80 mm dia
50 mm dia
40 mm dia
Supply and laying in replacement LT UG cable XLPE insulated armoured and PVC sheathed 1100 volts grade with aluminium conductor stranded of following sizes all as specified and directed :- Note : if the cable is laid in trenches, excavation, returning filling and removal of surplus soil shall be measured and paid separately under relevent item of this Schedule.
10 Sqmm 2 core
10 Sqmm 4 core
16 Sqmm 4 core
25 Sqmm 3.5 core
35 Sqmm 3.5 core
50 Sqmm 3.5 core
95 Sqmm 3.5 core
120 Sqmm 3.5 core
185 Sqmm 3.5 core
240 Sqmm 3.5 core
300 Sqmm 3.5 core
Supply & laying in replacement DWC (Double Wall Corrugated) HDPE pipe ISI marked of outer dia of 50 mm and inner dia 38 mm polyethylene including couplers, bends, cap etc., with smooth internal and profiled external surface for non pressure for under ground cable complete all as specified and directed by Engr-in-Charge Note : if the cable is laid in trenches, excavation, returning filling and removal of surplus soil shall be measured and paid separately under relevent item of this Schedule.
All as per item No 25.00 above but outer dia of 63 mm and inner dia 50 mm complete all as specified and directed by Engr-in-Charge
All as per item No 25.00 above but outer dia of 77 mm and inner dia 63 mm complete all as specified and directed by Engr-in-Charge
All as per item No 25.00 above but outer dia of 90 mm and inner dia 76 mm complete all as specified and directed by Engr-in-Charge
All as per item No 25.00 above but outer dia of 110 mm and inner dia 95 mm complete all as specified and directed by Engr-in-Charge
All as per item No 25.00 above here in before but outer dia of 120 mm and inner dia 103.5 mm complete all as specified and directed by Engr-in-Charge
All as per item No 25.00 above but outer dia of 160mm and inner dia 126 mm complete all as specified and directed by Engr-in-Charge
Excavation in soft / loose soil not exceeding 1.5 mtr wide and n exc 1.5 mtr depth and getting out incl forming of bottom for laying cable all as specified and directed
Excavation in hard / dense soil Including road cutting etc not exceeding 1.5 mtr wide and n exc 1.5 mtr depth and getting out incl forming of bottom for laying cable all as specified and directed
Returning filling using excavated soil including spreading leveling, watering and well ramming in layers n exc 25 cms all as specified and directed
Removal of surplus excavated material n.exc 50 mtrs and depositing where directed at a level n.exc 1.5 mtrs above the starting point all as specified and directed
M&L for disconnecting LT supply and taking out defective LT draw out EDO type ACB 440 V 800Amp / 630Amp and servicing by OEM .i.e Auth dealer cleaning the fixed and moving all parts, removing dust particles by using high speed blower applying grease/jelly to moving mechanism and moving parts, tightening nut bolts of all the components of ACB and complete testing and putting on full load complete all as specified and directed by Engr-in-Charge
S&F in replacement of isolating JAW contacts suitable for 800Amp / 630Amp LT draw out EDO type ACB complete all as specified and directed by Engr-in-Charge
S&F in replacement of polyester resin cast CT 800 / 5A suitable for 800Amp /630Amp LT draw out EDO type ACB complete all as specified and directed by Engr-in-Charge
S&F in replacement of ARC Chutes for Air circuit breakers EDO type suitable for 800Amp/630Amp complete all as specified and directed by Engr-in-Charge
S&F in replacement of Pole Unit for Air circuit breakers EDO type suitable for 800Amp/630Amp complete all as specified and directed by Engr-in-Charge
S&F in replacement of Draw out terminals for Air circuit breakers EDO type suitable for 800/630 Amp complete all as specified and directed by Engr-in-Charge
S&F in replacement of Lower terminals for Air circuit breakers EDO type suitable for 800Amp/630Amp complete all as specified and directed by Engr-in-Charge
S&F in replacement of Upper terminals for Air circuit breakers EDO type suitable for 800Amp/630Amp complete all as specified and directed by Engr-in-Charge
S&F in replacement of Charging motor for Air circuit breakers EDO type suitable for 800Amp/630Amp complete all as specified and directed by Engr-in-Charge
S&F in replacement of shunt trip and closing coil for Air circuit breakers EDO type suitable for 800Amp/630Amp complete all as specified and directed by Engr-in-Charge
S&F in replacement of manual Charging handle for Air circuit breakers EDO type suitable for 800Amp/630Amp complete all as specified and directed by Engr-in-Charge
S&F in replacement of under voltage trip device compact with UVT coil for Air circuit breakers EDO type suitable for 800Amp/ 630Amp complete all as specified and directed by Engr-in-Charge
S&F in replacement of Safety shutter assembly for Air circuit breakers EDO type suitable for 800Amp/630Amp complete all as specified and directed by Engr-in-Charge
S&F in replacement of Earth fault relay with NCT for Air circuit breakers EDO type suitable for 800/630 Amp complete all as specified and directed by Engr-in-Charge
M&L for earthing complete with Galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below GL) with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanized earth strip 32x6 mm size connected by means of bolts, nuts, check nuts and washer of galvanized iron or steel, provision of 15 mm dia GI pipe medium grade for protection of G1 earth wire and 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) , type CI chamber. MS funnel, wire gauge. 50 mm thick RCC 1:2:4, type B1 earth pit cover with 6 Nos. 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No 3 of schedule Part-I. Note: (i) Cost of GI earth wire and GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item.(ii) The unit rate shall also includes for Wire mesh, funnel, excavation, returninng & filling, PCC chamber pit, RCC cover & test point. (iii) PCC pit shall be provided at least 500mm away from the earth pit and not just on the earth pit. (iv) All accessories required for galvanised steel plate electrode required, as specified and as directed.
S & F in replacement of digital soft starter suitable for 15 HP submersible pump including testing complete all as specified and directed by Engr-in-Charge
S & F in replacement of star delta starter suitable for 10 to 12.5 HP submersible pump including testing complete all as specified and directed by Engr-in-Charge
M & L for repair of LT Panel board outdoor type repair/replace damaged door hinges set of three nos front and back side and legs 40x40x6mm MS angle and necessary cutting, welding drilling hole etc.works required at site complete all as specified and directed
M&L for providing cement concrete Type B1 1:2:4 (using 20mm graded stone aggregate ) as in hard standing after laying cable under road etc all as specified and directed.
M&L for finding out cable fault location for LT UG cable, XLPE insulated 1100 Volts, of any size with fault detector machine complete all as specified and as directed.
S&F in replacement of heavy duty resin filled capacitor 440 volt, 3 Ph of capacity up to 30 KVAR including connections and testing for proper functioning complete all as specified and directed by Engr-in-Charge
S&F in replacement of APFC Controller up to 5 Step including connections and testing for proper functioning complete all as specified and directed.
S&F in replacement of digital Volt meter (0-500) including connections and testing for proper functioning complete all as specified and directed.
S&F in replacement of digital ammeter including connections and testing for proper functioning complete all as specified and directed.
S&F in replacement of Indicating Lamp R. Y. B (LED) Type including connections and testing for proper functioning complete all as specified and directed.
S&F in replacement of CTs of capacity 50/5 including connections and testing for proper functioning complete all as specified and directed.
M&L for preparation of old surface and applying two coats of synthetic enamel paint by using spraying gun to feeder pillar box / LT panel & duct cover etc complete all as specified and as directed by Engr-in-Charge
M&L in replacement of notice board 6x4 feet , half mm thick foam sheet including writing of DG set/transformer/AC plant/Pumps details as per given format and shall be print in blue color only and letters are white color minimum 76 letters and maximum 90 letters and fixing with revit or screw complete all as specified and as directed by Engr-in-Charge Note : Before making order, sample copy shall be collected from JE E/M with details all as specified
M&L for in replacement of notice board 4x3 feet using half mm thick foam sheet including writing of particular details of E/M installations and shall be print in blue color only and letters are white color minimum 50 letters and maximum 70 letters and fixing with revit or screw complete all as specified and as directed by Engr-in-Charge Note : Before making order, sample copy shall be collected from JE E/M with details all as specified
Supply and fix PCC cable route indicator of size 0.75MX0.20MX60mm including marking of cable size and location complete all as directed. (Note:- Necessary excavation and PCC work for fixing of cable route indicator is included in the quoted rate.)
Supply and fix in replacement danger notice plate of 1.6mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of size 20x15cm complete all as specified and as directed by Engr-in-Charge
Supply and lay stone aggregate of 40mm size in 75 mm thickness underneath of 4 pole/ 2 pole structure/ transformer yard complete all as specified and as directed by Engr-in-Charge
Supply & Installation of 4 inch thick ACP Box of size 6 x 4 feet with MS pipe structure fix inside with 3mm Acrylic sheet with digitally printed 3M backlit vinyl on HP Latex Printer, Display both side, LED Modules complete up to 100 letters as specified size directed by Engr-in-Charge with Andaman and Nicobar command and MES logo fixed with four nos of MS pipe Heavy duty(C) 50mm bore up to 3Mtr height by nuts/bolts and welding as required at site, spray painting with two coat synthetic enamel paint complete MS pipe including necessary excavation and PCC work for foundation of MS poles as directed at site, complete all as directed by Engr-in-Charge
Supply & Installation of 4 inch thick ACP Box of size 12x4 feet with MS pipe structure fix inside with 3mm Acrylic sheet with digitally printed 3M backlit vinyl on HP Latex Printer, Display both side, LED Modules complete upto 100 letters as specified size directed by Engr-in-Charge with Andaman and Nicobar command and MES logo fixed with four nos of MS pipe Heavy duty(C) 50mm bore up to 6Mtr height height by nuts/bolts and welding as required at site, spray painting with two coat synthetic enamel paint complete MS pipe including necessary excavation and PCC work for foundation of MS poles as directed at site, complete all as directed by Engr-in-Charge
Supply and fix in replacement earth pit chamber board of 3.15mm thick mild steel sheet of size 45cmX30cm fixed with12mm thick MS rod two nos up to 90 cm height by nuts/bolts including spray painting with two coats of synthetic enamel black paint complete MS sheet both side including writing letters 6cm height i.e Eart pit No, Location, Earthing test Value and date complete all as directed by Engr-in-Charge.
Supply and fix in replacement aluminium cable lugs for cables of size up to 10 Sqmm including necessary crimping with crimping tool complete all as specified and directed by Engr-in-Charge Note : Necessary excavation, returning filing and removal shall be measured and paid separately under relevent item of this schedule
All as per item No 72.00 above but size up to 16 Sqmm complete all as specified and directed by Engr-in-Charge
All as per item No 72.00 above but size up to 25 Sqmm complete all as specified and directed by Engr-in-Charge
All as per item No 72.00 above but size up to 35 Sqmm complete all as specified and directed by Engr-in-Charge
All as per item No 72.00 above but size up to 50 Sqmm complete all as specified and directed by Engr-in-Charge
All as per item No 72.00 above but size up to 70 Sqmm complete all as specified and directed by Engr-in-Charge
All as per item No 72.00 above but size up to 95 Sqmm complete all as specified and directed by Engr-in-Charge
All as per item No 72.00 above but size up to 125 Sqmm complete all as specified and directed by Engr-in-Charge
All as per item No 72.00 above but size upto 185 Sqmm complete all as specified and directed by Engr-in-Charge
All as per item No 72.00 above but size upto 240 Sqmm complete all as specified and directed by Engr-in-Charge
All as per item No 72.00 above but size upto 300 Sqmmcomplete all as specified and directed by Engr-in-Charge
All as per item No 72.00 above but copper lugs of size upto 25 Sqmm complete all as specified and directed by Engr-in-Charge
All as per item No 72.00 above but copper lugs of size upto 35 Sqmm complete all as specified and directed by Engr-in-Charge
All as per item No 72.00 above but copper lugs of size upto 50 Sqmm complete all as specified and directed by Engr-in-Charge
All as per item No 72 above but copper lugs of size upto 70 Sqmmcomplete all as specified and directed by Engr-in-Charge
Supply and fix in replacement of single dome PVC LED aviation obstruction light 20W 215Volt 50Hz complete all as specified and directed by Engr-in-Charge
S&F in repairs PVC coated GI chain link fencing 3.5mm dia with 50mmX50mm mesh including fixing of MS line wire /rod flat iron & machine made hexagonal or squre head bolts to fencing post complete all as specified and directed by Engr-in-Charge
S&F Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc for supporting of tanks/chainlink fencing etc as directed by Engr-in-Charge .
Kathir Marketing Services
M/s Gurunath Construction
A. R. ELECTRICALS
ISLAND SALES ENTERPRISES
Tropical Refrigeration
PTech Engineers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .