Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.5 LAccepted-AOC RZ 40 PALAM VIHAR DWARKA SECTOR 6 NEW DELHI 75 | NEW DELHI | DELHI | 75 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹54.7 L+₹18.9 L (52.6%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | Rejected-Technical | - | Rejected-Technical No, not enlisted in category of work | |
| 4 | Rejected-Technical RZ 18 260 WEST SAGARPUR NEAR MCD SCHOOL NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | - | Rejected-Technical No, not enlisted in category of work |
Tender Value
₹49.9 L
EMD Value
₹99,860
Closing Date
31 Dec 2022, 6:00 pmClosed
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
GE UTILITY PLANT AND MACHINERY KIRBY PLACE DELHI CANTT-10
COMPREHENSIVE MAINTENANCE AND CERTAIN/REPAIR/REPLACEMENT FOR WI-FI AND DIGITAL INTERCOM SYSTEM AT BAIRD PLACE, PIRU VIHAR, DGIS, ARJAN VIHAR, MANEKSHAW MARG, CARRIAPPA VIHAR, TODAPUR, KABUL LINE AND SP MARG UNDER GE(U) PM DELHI CANTT-10
2022_MES_567127_1
GE(U)/PM/D-61/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
334 days
DELHI CANTT-10
MES contractor enlisted under class D category d(iv) having deposited standing security of Rs 100000 with department. Contractor not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category.
6 documents required · 6 mandatory
₹500
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
₹99,860
Yes
27 Feb 2023
3 Dec 2022
2 Jan 2023
3 Dec 2022
31 Dec 2022
17 Dec 2022
Amount
Section-I (BOQ Item 1 to 6) Comprehensive maintenance of installed server based IP PBX wi-fi intercom system, including repair/replacement of defective parts if any and make system fully functional installed at Piru Vihar complete all as directed by Engr-in-charge the following details :- Pocket- I ( Piru Vihar) (a) SIP based IP PBX -03Nos (b) OMNI Wi-Fi Sever-01No with antenna-31Nos (c) UPS offline and batteries-32 Nos (d) FXS gateway -35 Nos (e) WI-Fi receiver -31Nos (f) Hands free Car Set -60 Nos (g) Telephone wire from Hand set to machine room/antenna.
All as per item No 1. above but for DGIS complete comprising of following all as specified & directed by Engr-in-Charge :- Pocket -II (DGIS) (a) SIP based IP- PBX -02Nos (b) Wi-Fi Sever -01No,with antenna- 06 Nos (c) UPS offline and batteries -07 Nos (d) FXS gateway -09 Nos (e) WI-Fi receiver -06 Nos (f) Hands free Car Set -05 Nos (g) Telephone wire from Hand set to machine room/antenna.
All as per item No 1. above but for Baird Place complete comprising of following all as specified & directed by Engr-in-Charge ::- Pocket -III (Baird Place) (a) SIP based IP PBX -01 No (b)OMNI wifi server -01No with antena -13 Nos (c) UPS offline -14 Nos (d) FXS gateway - 17 Nos (e) Wi-fi receiver - 13 Nos (f) Hands free Car set - 24Nos (g) Telephone wire from Hand set to machine room /antena.
Comprehensive maintenance of installed digital EPABX Exchange system of 4x4x40 lines including all defective parts Voltage Transformer of CAP 500 VA with output 220V +_1 %, steel casing enclosure for hands free operated with high gain amplifier telephone set, battery 12 volts 7 AH, MDF 20 Pairs, Caller ID (CLI) card for exchange, Analog Line extention(ALC) card exchange complete and system fully functional at carriappa vihar complete comprising of following all as specified & directed by Engr-in-Charge :- - Pocket -VI (Carriappa Vihar) :- (i) Push button phone – 30 Nos (ii) KTS – 01 Nos (iii) Battery 7AH 12 volts – 02 Nos (iv) UPS system ( 500 VA 200 Volts) – 01 Nos (v) Telephone wire from handset to machine room at all lift buildings. (vi) MDF box120 Pairs - 01 Nos (vii) MDF 10 Pairs - 15 Nos (viii) EPABX Exchange - 01 Nos
All as per item No 4. above but for at SP Marg complete comprising of following all as specified & directed by Engr-in-Charge :- Pocket -VII (SP Marg):- (i) Push button phone – 30 Nos (ii) EPABX Exchange - 02 Nos (iii) Battery 7AH 12 volts – 04 Nos (iv) UPS system ( 500 VA 200 Volts) – 02 Nos (v) Telephone wire from handset to machine room at all lift buildings. (vi) MDF box120 Pairs - 02 Nos (vii) MDF 10 Pairs - 30 Nos (viii) KTS – 02 Nos
All as per item No 4. above but for at Todapur complete comprising of following all as specified & directed by Engr-in-Charge :- Pocket -VIII (Todapur):- (i) Push button phone – 07 Nos (ii) EPABX Exchange - 01 Nos (iii) Battery 7AH 12 volts – 02 Nos (iv) UPS system ( 500 VA 200 Volts) – 01 Nos (v) Telephone wire from handset to machine room at all lift buildings. (vi) MDF box10 Pairs - 04 Nos (vii) KTS – 01 Nos
Notes for section I:- (i) The Comprehensive maintenance (Section-I) under this contract shall be done through OEM i.e. any one of M/s Matrix Telecom Solutions/ M/s NEC/ M/s Creative Telecom (P) Ltd/ M/s Core-IP/ M/s SAN Software. The contractor is liable to submit MoU on stamp paper of Rs 100/- duly notarized, as per specified Performa (On srl page No. 108 to 110) and copy of Maintenance Contract from the OEM within tewnty one days from date of Acceptance of tender. If the delay from OEM side to submit the MoU, the contractor to be submit evidence to the Accepting Officer and permission to be obtained from Accepting Officer for delay in submission of MoU. (ii) Contractor will conclude AMC with OEM and copy of the agreement along with Invoice will be submitted to Engineer-in-Charge and GE. No payment will be made to contractor without submission of valid AMC agreement and Invoice. (iii) The above maintenance include complete maintenance of existing intercom system by regularly and systematically examining as required for smooth and efficient functioning of the equipment. Cost of all major and minor spares items including cables are deemed to be included in the above rate.
.(iv) Contractor should send Telephone Mechanic to attend/ rectify the complaints for all the locations during 0800 Hrs to 1800 Hrs as and when complaint is lodged for breakdown on call basis for any No of times during the month. (v) Contractor should rectify the minor defect within 8 hrs and major defect within 24 hrs after receiving the complaint from user/ MES Rep on site including Sundays and Holidays, failing which a penalty of Rs 1000/ per complaint per day shall be levied upon contractor. (vi) All minor/ major spare for instrument (i.e. phone hand set, car set type hands free intercom set, steel casing enclosure for telephone set, MDF crown, CLI card, ALC card/ UPS with battery as required and battery 12 volts, 7 AH make:- Exide/ Amaron/ Standard Furkkawa) are deemed to be included with quoted rates. (vii) The contractor deemed to have visited the site and seen the scope of work before quoting the rates. (viii) Monthly Service report duly signed by OEM, contractor & Engr-in-Charge to be submitted to deptt, failing which a penalty of Rs 5000/- per individual IP PBX wi-fi /EPABX system shall be levied & deducted from running payments of contractor.
Section-II (BOQ Item 8 to 24) Supply, Fixing, testing and Commissioning in replacement of old unsv one with latest Wi-Fi Radio transmitters PTMP mode having following Specifications.Make-Creative / Cambium / Ruckus (a) Integrated 18 dBi dual polarized 90 degree sector antenna (b) Smart polling data transmission protocol (iPoll-3) (c) Meets IP-66 specification (d) High output power 29dBm radio (e) Upto 170 Mbps Capacity.
Supply fixing, Testing and Commissioning in replacement of old unsv one with latest SIP IP Phones for operators at control room, having following features complete all as specified and directed.Make-Alcatel / Polycom / Grandstream (a) 6 Lines (b) 4.3" (480X272) TFT Colour LCD Display (c) 5 Programmable soft Keys (d) 5-way Conference (e) 24 Programmable Multi-Purpose Keys
Supply, fixing, Testing and Commissioning in replacement of old unsv one with latest 5 Ports network switch at lift machine room to connect radio transmitters and receivers.complete all as specified & directed. (Make-D-Link / Cisco / Alcatel)
Supply, Fixing, Testing and Commissioning in replacement of old unsv one with latest Wi-Fi Radio receiver PTP mode having specifications are Make-Asian / MTS / Perfect (a) Integrated directional 15 dBi panel antenna (b) Smart polling data transmission protocol (iPoll-3) (c) Meets IP-66 specification (d) High output power 29dBm radio (e) Upto 170 Mbps Capacity
Supply, Fixing, Testing and Commissioning in replacement of old unsv one with latest handfree lift WI-FI phone for each lift with high performance amplifier enclosed in SS box with lock facility complete all as specified & directed. (Make- Creative / Beetel / Panasonic)
Supply, Laying and Testing in replacement of old unsv one with latest standard CAT-6 cable that should confirm specifications TIA/EIA-568-A standard for connecting and providing power to Wi-Fi complete all as specified & directed. (Make- Digilink / D-Link / AMP)
Supply and Fixing in replacement of old unsv one with latest 1" PVC pipe heavy duty pipe from control room to Wi-Fi transmitter and machine room to Wi-Fi receivers to protect CAT-6 cables running through it including all conncetd bends,tees, reducer , albow, sochet, junction box etc complete all as specified & directed. (Make-Polycab /Kalinga)
Supply and Fixing in replacement of old unsv one with 2" GI pipe at roof-top providing support to Wi-Fi antennas at roof-top of all buildings including all type civil work if required. complete all as specified & directed. Make : Tata/Jindal/Prakash Surya
Supply and Fixing in replacement of old unsv one with latest PDU (3+1) to provide AC power to FXS gateway, Wi-Fi adaptor, UPS etc.complete all as specified & directed by Engr-in-Charge. Make-Asian / MTS / Perfect
Supply and fixing in repairs of lift car set hand free operated with high gain amplifier intercom set (Telephone) complete all as specified & directed by Engr-in-charge. (Make:- Tata/ Panasonic/ Beetal).
Supply & fixing in repairs of stainless steel casing enclouser for (Telephone) lift car set hand free operated with high gain amplifier intercom set with locking arrangment as per site requirement complete all as specified & directed by Engr-in-charge. (Make:- Tata/ Panasonic/ Beetal).
Supply and fixing in repairs of KTS tele phone card having features : 50 station phonebook corded, phone alphanumeric keypad 20 redial memory complete all as specified & directed by Engr-in-charge.
Supplying, laying and testing of Armoured insulated copper cable and sheathed with GI strip/wire heavy duty telephone cable of size 0.60 mm x 10 pairs fixed on wall/ pole including taking down old unserviceable one complete all as specified & directed by Engr-in-Charge. (Make : Delton/Plaza/Finolex/ R R Kabel/ Havells.)
Supplying, laying and testing of Armoured insulated copper cable and sheathed with GI strip/wire heavy duty telephone cable of size 0.60 mm x 5 pairs fixed on wall/ pole including taking down old unserviceable one complete all as specified & directed by Engr-in-Charge. (Make : Delton/Plaza/Finolex/ R R Kavel/ Havells.)
Taking down and Material & labour for replacement of defective travelling cable PVC insulated flexible flat copper conductor of size 0.75sqmm 4 core and other connected accessories suitable for intercome complete all as per site requirement and as directed by the Engineer-in-charge. ( Make- Macrotharm/ Finolex/ Havells)
Supply & fixing maintenance free sealed LED acid battery of cap-12V,18AH for ARD for any make and model of lifts including taking down complete all as specified and directed. (Make:- EXIDE/AMARON/ STANDARD FURKKAVA)
Supply & fixing maintenance free sealed LED acid battery of cap-12V,09 AH for lifts of any make including taking down complete all as specified and directed. (Make:- EXIDE/AMARON/ STANDARD FURKKAVA)
Note- (I) The Repair/maintenance of (Section-II) (Except item No 22, 23 & 24 ) under this contract shall be done through OEM i.e. M/s Creative Telecom (P) Ltd)
Section-III (BOQ Item 25 to 49) M&L in replacement of earthing with galvanised steel earth plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts check nuts and washers of galvanised iron wire of 4mm dia as earth lead as shown in electrical plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1:3:6 type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe, 40mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover 50mm thick made of RCC (1:1.5:3) type A1 duly reinforced with 8mm dia TMT bar @100mm c/c both ways, one lifting handle made out of 10mm dia TMT bar 250mm long embedded in cover slab and cover, wire, copper lugs etc mesh, chorcoal and common salt in alternate layer of 15cm thick complete all as specified and directed. Note:- (i) Each protection pipe and earthing lead upto and including 7.5 meter lenght is deemed to be included in the qouted rate of this item.
Supply & fix in replacement of GI strip 25 x 6 mm and necessary clamps,shaddels,screws complete from machine room equipment to earth pit including taking down of old one or connecting in pieces with old one complete all as specified & directed by Engr-in-Charge. .Note:- (i) Rate for fixing of earthing strip from earth pit to lift machine room from shaft will be included in the quoted rate.
Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete (fitting such as switches, ceiling roses, pendent, regulator socket etc to be measured separately) and making good disturbed surfaces of wall floor etc complete all as specified and directed.
Taking down old and unserviceable sub main wiring and removing from the site and making good the disturbed surface complete all as specified and directed.
M&L point wiring for normal switches with 1.5 sqmm , single core , multi stranded copper conductor PVC insulated and unsheathed (FRLS) cable 1100 Volts grade, drawn through existing concealed Conduit as requirement of site including cadmium plated screws as per ISI, including replacement of 3 mm thick phenolic laminated sheet top covers on and including sunk type CI/steel terminal boxes concealed in wall including 1.5 Sqmm size pvc insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly for One light point controlled by one switch 5 Amps one way single polecomplete all as specified and directed.Make-Havells/Finolex/Standard/Polycab. Note : Rate for point wiring in lifts shaft will be included in the quoted rate.
All as per item No. 29 above but one three pin 5 Amps socket out let on independent board. Note : Rate for point wiring in lifts shaft will be included in the quoted rate.
All as per item No. 29 above but one three pin 5 Amps socket out let on same board. Note : Rate for point wiring in lifts shaft will be included in the quoted rate.
All as per item No. 29 above but point wiring of copper cable multi stranded 2.5 Sqmm size for 15 Amps socket outlet on independent board with 2.5 Sqmm size of earth conductor complete all as specified and directed. Make-Havells/Standard /Finolex/Polycab Note : Rate for point wiring in lifts shaft will be included in the quoted rate.
M&L in replacement of old unsv one with new submain wiring with two single core 4 Sqmm PVC insulated FRLS multistrand copper conductor cable drawing into and including rigid non metallic PVC casing caping ISI marked with all fittings & fixing accessories and one single core 4 Sqmm FRLS multistrand copper conductor cable as continuous earth wire complete all as specified & directed. Make-Polycab/Finolex/Havells Note : Rate for point wiring in lifts shaft will be included in the quoted rate.
M&L in replacement of old unsv one with new submain wiring with two single core 6 Sqmm PVC insulated FRLS multistrand copper conductor cable drawing into and including rigid non metallic PVC casing caping ISI marked with all fittings & fixing accessories and one single core 6 Sqmm FRLS multistrand copper conductor cable as continuous earth wire complete all as specified & directed. Make-Polycab/Finolex/Havells Note : Rate for point wiring in lifts shaft will be included in the quoted rate.
Supply and fix in repair Switch Piano type, white polycarbonate body, single pole, one way 6 amp, 230 V, including connecting complete all as specified and directed by Engr-in-Charge. Make :- Anchor, Cona, Legrand
Supply and fix in repair socket white polycarbonate body, 6A-230 V, Multipurpose, including connecting complete all as specified and directed by Engr-in-Charge. Make :- Anchor, Cona, Legrand
Supply and fix in repair switch white polycarbonate body, 16A- 230 V, 2/3 pin combined, including connecting complete all as specified and directed by Engr-in-Charge. Make :- Anchor, Cona, Legrand
Supply and fix in repair socket white polycarbonate body, 6A/16A- 230 V, 2/3 pin combined, including connecting complete all as specified and directed by Engr-in-Charge. Make :- Anchor, Cona, Legrand
S&F Switch socket combination box piano type 2in 1, 3 pin, 6/16 Amp flush type universal complete all as specified and directed all as specified and directed by Engr-in-Charge. Make : Anchor/Havells/SSK.
Supply and Fixing in replacement of old unsv one with Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCBs with plug top complete all as specified & directed. Make: Legrand/Havells/schnider/C&S
S & F in repair distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN 8 way with 200 Amps rated copper busbar, neutral bar, earth bar, IP 43 protection, single pole and neutral 250 Volts, flush to wall complete all as specified and directed. Make : Legrand / Havells/Siemens / Schnieder
S & F in repair MCB SP 240 Volts, 6-32 Amps complete all as specified and directed. Make- Make-Legrend/Crabtree/Havells
S & F in repair MCB SPN, 240 Volts, 40 Amps complete all as specified and directed. Make-Havells/Legrend/Crabtree
S&F in replacement of energy efficient Surface/Wall Mounted 20W integrated LED batten 4 feet Fitting with polycarbonate housing. Total system Lumen of 20W to 22W LED should be 2200 or above in Cool day Light(5700K to 6500K), Power factor>0.95, CRI (Ra) >80, System Lumen Efficacy>110 Lm/w, THD(%) < 20, LED Lamp LED Lamp Efficacy>130 Lm/W with Average life of 50000 Burning hours. Complete with all accessories as required with connections. complete all as specified and directed by Engg –in-charge. Make - Havells/Wipro/Philips.
S&F in replacement energy efficient LED batten tube light, Surface/Wall Mounted 9W to 10W integrated LED 2 feet Fitting with polycarbonate housing. Total system Lumen of 9W Led should be 990 or above in Cool day Light(5700K to 6500K), Power factor>0.95, CRI (Ra) >80, System Lumen Efficacy>110 Lm/w, THD(%) < 20, LED Lamp, LED Lamp Efficacy>130 Lm/W with Average life of 50000 Burning hours. Complete with all accessories as required with connections. Make Havells Cat Part No. - Make - Havells/Wipro/Philips.
Supply and fix in repair LED bulkhead 10 watt cap complete all as specified and directed Make :- Wipro/Havells/ Philips
Supply and fixing in repair of 300mm sweep lift car cabin fan, single phase, 1350 RPM in lift with necessary accessories such as fins/ grills, nuts, bolts and suitable size of wires, etc suitable for any type of lifts including taking down old unserviceable fan complete all as specified and directed by Engr-in-Charge. (Make:- BAJAJ/ CROMPTON GREAVES/GEC/ HAVELLS/ KHAITAN/ORIENT)
Supply & fixing in repair of exhaust fan heavy duty of size 300mm sweep,Motor Speed: 1400 RPM,with louver of metal body including cutting of hole in wall of suitable size and including all accessories such as suitable size of fasteners, flexible wires for connections, testing, assembling and making good disturbed surfaces of wall including taking down old unserviceable one complete all as specified and directed by enge Engr-in-Charge. (Make:- Havells/ Crompton Greaves/ Bajaj/ Usha/ Khaitan).
Supply & fixing in repair of exhaust fan heavy duty of size 380mm sweep,Motor Speed: 900 RPM, Power Consumption: 410 W with louver of metal body including cutting of hole in wall of suitable size and including all accessories such as suitable size of fasteners, flexible wires for connections, testing, assembling and making good disturbed surfaces of wall including taking down old unserviceable one complete all as specified and directed by enge Engr-in-Charge. (Make:- Havells/ Crompton Greaves/ Bajaj/ Usha/ Khaitan).
D P ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .