Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.8 LAccepted-AOC | ₹33.8 L | L1 | Accepted-AOC Awarded |
| 2 | L2₹34.8 L+₹1.0 L (3.00%)Rejected-Finance AURANGABAD | MAHARASHTRA | 423701 | ₹34.8 L+₹1.0 L (3.00%) | L2 | Rejected-Finance REJECTED |
| 3 | L3₹35.5 L+₹1.7 L (5.00%)Rejected-Finance | ₹35.5 L+₹1.7 L (5.00%) | L3 | Rejected-Finance REJECTED |
Tender Value
₹33.8 L
EMD Value
₹67,609
Closing Date
18 Aug 2026, 5:00 pmClosed
Chief Officer,Municipal Council Vaijapur
Municipal Council Vaijapur
Providing External And Internal Electrification Work In Hutatma Jagannath Vegetable Marker, Vaijapur For Municipal Council Vaijapur
2026_DMA_1327146_1
E Tender / Vaijapur M.C / NIT 01 / 2026-27
Open Tender
Civil Works
Percentage
180 days
Vaijapur
Please refer Tender documents.
3 documents required · 3 mandatory
₹3,500
₹67,609
18 Sept 2026
11 Aug 2026
20 Aug 2026
11 Aug 2026
18 Aug 2026
11 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Providing External & Internal Electrification Work In Hutatma Jagannath Vegetable Marker, Vaijapur For Municipal Council Vaijapur | - | - | - | - |
| 2 | Supplying, installing, testing & commissioning of 3 phase, 11/0.433 kV, 50 Hz.,200 kVA, Mineral oil immersed and naturally cooled outdoor type, aluminium wound Non-sealed transformer, delta/star connected with additional neutral brought out on load side, temperature rise should not exceed 40℃ by thermometer in oil and 45℃ by the resistance method in winding at full load rating, using type A winding insulation (Kraft paper) , with standard accessories complete with test certificate with losses below 475 Watts at 50%load, 1650 Watts at 100% load as per IS:1180 (part 1) : 2014, with necessary permissions of Electrical Inspector, as per specification no SS- TR-NSL. | 1 | Each | 0.87 | ₹0.87 |
| 3 | Supplying & erecting inline D. P. Structure for 11/0.415 kV, 200 kVA Transformer with R.S.J. Pole 2 Nos. of size 100 x 116 mm x 11 Mtr. Long with suitable Distribution Box of C.R.C.A. Sheet 16 SWG with 4 Pole MCCB 200Amps as incomer & 6 Nos. 100 Amps KitKat / MCCB for out going circuits. Transformer D.P. Structure includes the A. B. Switch 200 Amps, D.O. fuse Set &L.A. Set. 2 Nos. of Top channel of size 100 mmx 50 mm for erection of A.B.Switch & 2 Nos. Base channel of size 100 mm x 50 mm for erecting Transformer Channel of size 75 x40 mm for erecting D.O. Fuse Set, L.A., A.B. Switch handle etc. Angle of size 50 x 50 x6 mm for erecting Distribution Box , Transformer Beltetc.as per drawing (min. 124 Kg. iron work ) with necessary clamps, Nut-bolts. Vcross arm, top clip, insulators etc. complete with caution board & barbed wire,D.P. Structure shall be erected in c.c. foundation complete | 1 | Each | 1,64,785.95 | ₹1,64,785.95 |
| 4 | CAPTIVE POWER Making transformer plinth (1.5 x 1.5 x 1.5) m in size with necessary excavation in ground with 150 mm. thick M- 10 PCC at the bottom and top and 250 mm. thick, burnt brick wall constructed at periphery and remaining hollow portion shall be filled with 40mm hard broken aggregate. External surface duly plastered by 12 mm thick including watering etc complete. | 1 | Each | 15,017.1 | ₹15,017.1 |
| 5 | LT PANELS Supplying and erecting GI sheet 1.6 mm (16 SWG) having zinc coating of 350microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. | 3 | Sqm | 2,688 | ₹8,064 |
| 6 | Supplying, erecting, testing & commisioning bus bar chamber triple pole with neutral with four aluminium bars, 500V 200A having 25mm ( width) X 5 mm (thickness), with 99.9 % aluminium purity as per E91E grade & currentdensity 0.8 A per sq mm compliance to IS 5082 and enclosure fabricated with 16SWG CRCA sheet and epoxy paint, with suitable number of ways and with SMC/DMC Insulators and accessories of suitable rating and two nos of separateearthing terminals complete as per specification no. CP-BB1.20 Mtr busbar for main building + 1.00 Mtr busbar for SHopping ComplexTotal = 1.2 +1.0 = 2.20 mtr | 3 | Mtr | 6,420.75 | ₹19,262.25 |
| 7 | Supplying and erecting Intelligent flush mounted panel meter three phase four wire (IPM) input voltage measurement range 50-550 V AC (P-P) 415V, aux.supply 90-300 V AC/DC, flush mounted (96 x 96 mm) meter constant Whviewing in LCD multifunction meters in auto scroll mode with voltage, current, frequency, power factor kW, kVA, kVAR, kWh, kVAh, kVARh, phase angle, interrupts, THD, complete with RS 485 communication protocol, class 1 accuracy and wiring connections and mounting hardware on provided panels complete with calibration certificate from manufacturer. | 1 | Each | 9,303 | ₹9,303 |
| 8 | Supplying & erecting LED type indicating pilot lamp with LED colours red /yellow / green, 230 / 250V on provided box / panel with necessary material, wiring & connections etc. | 4 | Each | 260.4 | ₹1,041.6 |
| 9 | Supplying & erecting LED type indicating pilot lamp with LED colour blue,230 / 250 V on provided box / panel with necessary material, wiring &connections etc. | 2 | Each | 371.7 | ₹743.4 |
| 10 | Supplying and erecting triple pole mini feeder pillar with 500V, 300A FP MCCB as incomer and 3 outgoing circuits with HRC fuse base and cartridge of 100A with aluminium bus bar erected in 14 SWG CRCA sheet boxwith supporting angles, self locks, gasket having IP54,IK10 protection and slantingtop to be erected on provided foundation as per specification no. SW-SWR/MFP | 1 | Each | 58,113.3 | ₹58,113.3 |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.41 MB
BOQ_2272745.xls
BOQ • 0.48 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .