Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.8 LAccepted-AOC | ₹18.8 L Quoted ₹19.3 L | L1 | Accepted-AOC being lowest bidder |
| 2 | L2₹20.0 L+₹63,326 (3.27%)Rejected-Finance H NO 1395 SECTOR 21 PANCHKULA 134112 HARYANA | PANCHKULA | HARYANA | 134112 | ₹20.0 L+₹63,326 (3.27%) | L2 | Rejected-Finance Other than lowest tender |
| 3 | L3₹20.7 L+₹1.4 L (7.00%)Rejected-Finance HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | ₹20.7 L+₹1.4 L (7.00%) | L3 | Rejected-Finance Other than lowest tender |
| 4 | L4₹21.0 L+₹1.7 L (8.57%)Rejected-Finance H NO 1346 SECTOR 13 P HISAR 125005 HARYANA | HISAR | HISAR | HARYANA | 125005 | ₹21.0 L+₹1.7 L (8.57%) | L4 | Rejected-Finance Other than lowest tender |
| 5 | L5₹21.2 L+₹1.9 L (9.69%)Rejected-Finance 252 22 NEAR SOCITY BUS STAND INDRA COLONY PATHANKOT 145001 | PATHANKOT | PUNJAB | 145001 | ₹21.2 L+₹1.9 L (9.69%) | L5 | Rejected-Finance Other than lowest tender |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
26 Jul 2022, 6:00 pmClosed
GE 865 EWS
GE 865 EWS, PIN-913 865 C/o 56 APO
REPAIR MAINT OF INTERNAL ELECTRIFICATION AND PETTY REPAIRS AT SECTOR C HQ CELZ AND ADJACENT AREA UNDER AOR OF AGE EM I OF GE 865 EWS
2022_MES_532036_1
865/EWS(NIT-56)/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
GE 865 EWS
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
GE 865 EWS
₹80,000
Yes
26 Aug 2022
18 Jun 2022
28 Jul 2022
18 Jun 2022
26 Jul 2022
4 Jul 2022
Amount
Taking down carefully copper/Aluminium point wiring (Light, Fan, Socket or power) complete fitting such as switches, ceiling, regulator, sockets etc removing materials to be store for keeping in safe custody for re-use at site and making good disturbed surfaces of walls, floors etc complete all as specified and directed by Engr-in-Charge.
M&L for point wiring with copper conductor cable, multistranded, single core 1.5 Sqmm size for one light/exhaust point controlled by one switch with PVC insulated multistranded copper conductor cable of size 1.5 sq mm for earth continuity in and including PVC casing and capping of approved size and quality fixed on walls/ceiling/wooden panelling including fixing 3 mm thick bakelite sheet on wooden board of any size complete all as specified and directed by Engr-in-Charge. Make of cable: As per PS Make of casing caping As per PS
All as per Item No 2.00 but for one bell/buzzer point controlled by one push button on the same board with other switches or independent with cables 1.5sqmm size complete all as specified and directed by Engr-in-Charge.
All as per Item No 2.00 but for one 3 pin socket outlet, 6 Amps, 230 volts on the same board with other switches, with cables 1.5 Sqmm size complete all as specified and directed by Engr-in-Charge.
All as per Item No 2.00 but for one 3 pin socket outlet, 6 Amps, 230 volts Independent board, with the cable 1.5 sqmm size complete all as specified and directed by Engr-in-Charge.
All as item No. 2 above but using cables 4 Sqmm complete all as specified and directed by Engr-in-Charge.
S&F in replacement for lamp holder PVC/Poly corbonate type insulated body with back plate suitable for batten fittings complete all as specified and directed by Engr-in-Charge. Make : As per PS
S&F in replacement for switch piano flush type one way single pole 6 Amps 230 volts complete all as specified and directed by Engr-in-Charge. Make : As per PS
S&F in replacement for switch socket outlet 5 pin 6 Amps flush type 230 volt complete all as specified and directed by Engr-in-Charge. Make : As per PS
S&F in replacement for switch socket outlet 5 pin 6 Amps and 16 Amps, 230 volts flush type complete all as specified and directed by Engr-in-Charge. Make : As per PS
S&F in replacement for ceiling rose surface bakelite 65x50 mm two to three terminals all as specified and directed by Engr-in-charge. Make : As per PS
S&F in replacement bell push single pole 230 volt complete all as specified and directed by Engr-in-Charge. Make : As per PS
S&F in replacement for Bells Ding- dong single pole 230Volts complete all as specified and directed by Engr-in-Charge. Make : As per PS
S&F in replacement for Modular switch one way 6 Amp 1 module 230 volts complete all as specified and directed by Engr-in-Charge. Make : As per PS
S&F in replacement for Modular switch socket combination outlet 5 pin 6 Amps flush type 230 volts complete all as specified and directed by Engr-in-Charge. Make : As per PS
S&F in replacement for Modular switch socket combination outlet multi purpose 5 pin 6 Amps and 16 Amps 230 volts complete all as specified and directed by Engr-in-Charge. Make : As per PS
S&F in replacement for modular white cover plate with frame of 3 module suitable for 3 pin 6 Amps and 16 Amps 230 volts complete all as specified and directed by Engr-in-Charge. Make : As per PS
S&F in replacement for modular white cover plate with frame of 6 module suitable for 5 pin 6 Amps and 16 Amps 230 volts complete all as specified and directed by Engr-in-Charge. Make : As per PS
S&F in replacement of modular metal flush box of 03 module suitable for 5 pin 6 Amps and 16 Amps 230 volts complete all as specified and directed by Engr-in-Charge.
S&F in replacement of modular metal flush box of 06 module suitable for 5 pin 6 Amps and 16 Amps 230 voltscomplete all as specified and directed by Engr-in-Charge.
S&F in replacement of sheet metal enclosure for DBs double door when MCBs to be used single pole & neutral 240 volts 4 way concealed to wall and making flush with wall surfaces and making good to disturbed surfaces of walls to match with the exisiting surface etc incl taking down old DBs complete all as specified and directed by Engr-in-Charge. Make: Cat part No 5076 10 of Legrand (Ekinoxe) or equivalent as per PS
S&F in replacement of sheet metal enclosure for DBs double door when MCBs to be used single pole & neutral 240 volts 8 way concealed to wall and making flush with wall surfaces and making good to disturbed surfaces of walls to match with the exisiting surface etc incl taking down old DBs complete all as specified and directed by Engr-in-Charge. Make: Cat part No 5076 10 of Legrand (Ekinoxe) or equivalent as per PS
S&F in replacement of sheet metal enclosure for DBs double door when MCBs to be used single pole & neutral 240 volts 12 ways concealed to wall and making flush with wall surfaces and making good to disturbed surfaces of walls to match with the exisiting surface etc incl taking down old DBs complete all as specified and directed by Engr-in-Charge. Make: Cat part No 5076 10 of Legrand (Ekinoxe) or equivalent as per PS
S&F in replacement of sheet metal enclosure for DBs double door when MCBs to be used three pole & neutral 415 volts 4 Ways concealed to wall and making flush with wall surfaces and making good to disturbed surfaces of walls to match with the exisiting surface etc incl taking down old DBs complete all as specified and directed by Engr-in-Charge. Make: Cat part No 5076 10 of Legrand (Ekinoxe) or equivalent as per PS
Supply and fixing MCB SPN 63 Amps, 240 Volts AC ISI marked complete incl taking down old MCBs complete all as specified and directed by Engr-in-Charge. Make: Cat part No 4086 20 of Legrand (DX³) or equivalent as per PS
Supply and fixing MCB SPN 40 Amps, 240 Volts AC ISI marked complete incl taking down old MCBs complete all as specified and directed by Engr-in-Charge. Make: Cat part No 4086 20 of Legrand (DX³) or equivalent as per PS
Supply and fixing MCB SP 40-100 Amps, 240 Volts, 50HZ complete incl taking down old MCBs complete all as specified and directed by Engr-in-Charge. Make: Cat part No 4085 87 to 4085 95 of Legrand (DX³) or equivalent as per PS
Supply and fixing MCB SP 6 to 32 Amps, 240 Volts, AC complete incl taking down old MCBs complete all as specified and directed by Engr-in-Charge. Make: Cat part No 4085 87 to 4085 95 of Legrand (DX³) or equivalent as per PS
S&F in replacement of LED, 36watt, recessed 600x600 mm 220 volts AC, luminaire to enhance the delight of occupants with comfortable experience through its design & glare free soft illumination and connection of 3 core copper wire with all accessories(Warm White) suitable for roof ceiling including connecting up with driver complete all as specified and directed by Engr-in-Charge. Make : Cat part No -BZRSQL 36 W GZi W (Natural White) of Bajaj or equivalent as per PS
S&F in replacement of round shape, 12 watt, 220 volts AC, recessed type with high efficiency PMMA diffuser, soft glare free light complete with driver, holder and LED lamp suitable for roof ceiling incliuding connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr-in-Charge. Make : As per PS
S&F in replacement of round shape, 6 watt, 220 volts AC, recessed type with high efficiency PMMA diffuser, soft glare free light complete with driver, holder and LED lamp suitable for roof ceiling incliuding connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr-in-Charge. Make : As per PS
S&F in replacement of LED light fittings 1x10 watt Bulk head Luminares incl LED lights driver holder connecting up with 3core copper flexible conductor cable of sutable size complete all as specified and directed by Engr-in-Charge. Make : As per PS
S&F in replacement of LED light fittings 1x20 watt, 220 volts AC, decorative box type with driver, holder including LED tube lights suitable for roof ceiling incl connecting up with 3core copper flexible conductor cable of sutable size complete all as specified and directed by Engr-in-Charge. Make : As per PS
S&F in replacement of Air circulator made of study Engineering plastic complete wit louvers, shutters, voltage 230 volt, 50 Hz RPM 1200, copper winding of sweep 300 mm complete all as specified and directed by Engr-in-Charge. Make : As per PS
S&F in replacement of Air circulator made of study Engineering plastic complete wit louvers, shutters, voltage 230 volt, 50 Hz RPM 1200, copper winding of sweep 250 mm complete all as specified and directed by Engr-in-Charge. Make : As per PS
S&F in replacement of heating element suitable for water storage heater vertical type, 220/240 V AC, 1500 watts and making connections and testing complete all as specified and directed by Engr-in-Charge.
S&F in replacement of heavy duty PVC connection armoured type wit hbrass check nuts, heat resistance type rubber washer for hot water complete all as specified and directed by Engr-in-Charge. Make : As per PS
S&F in replacement of thermostate switch for water storage heater suitable for Racold type 220/240 V, 50 HZ, AC temperature range 32-88 degree centigrade ISI marked complete all as specified and directed.
Material and labour for earthing complete with galvanised steel earth plate 600 x 600 x 6 mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below ground level connected to and including GI wire of size 4 mm dia by means of nuts, bolts, washers etc made of and connected to test point and earth dolly as all shown in electrical plate No.3 of SSR Part-I 2009 and specified or indicated including excavation and earth work in any type of soil PCC (1:3:6) type C1 in chamber, pre cast RCC slab 50mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM jali (weight not less than 4.0 kg/Sqm) with cast iron frame, funnel, with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 15mm bore light grade GI protection pipe, test point etc incluidng taking down of old u/s earthing set complete all as specified and directed by Engr-in-Charge. Note: (i) Item includes the cost of 7.5 m GI pipe for protection of earth lead. Any additional length shall be adjusted through deviation order. (ii) Item includes the cost of 7.5 m GI earth lead. Any additional in length shall be adjusted through deviation order ( For Main DBs ) (iii) Item includes the cost of Charcoal and commercial salt ( For Main DBs )
Sub main wiring with earth wire with the size (2x4 sqmm) 240 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor confirming to IS-694 drawn through and including non-metalic PVC casing caping ISI marked with all accessories etc with one run of 4 Sqmm (1x4 sqmm) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire, sinking of MS boxes and making good to match with existing surfaces complete all as specified and directed by Engr-in-Charge. Note:- 2 runs of 4Sqmm (2x4sqmm), 1 run of 4Sqmm (1x4 sqmm) cable and one metre of casing caping will be measured as one unit.
Sub main wiring with earth wire with the size (2x6 Sqmm) 240 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor confirming to IS-694 drawn through and including non-metalic PVC casing caping ISI marked with all accessories etc with one run of 6 Sqmm (1x6 Sqmm) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire, sinking of MS boxes and making good to match with existing surfaces complete all as specified and directed by Engineer-in-Charge. Note:- 2 runs of 6Sqmm (2x6 Sqmm), 1 run of 6 Sqmm (1x6 Sqmm) cable and one metre of casing caping will be measured as one unit.
Sub main wiring with earth wire with the size (2x10 Sqmm) 240 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor confirming to IS-694 drawn through and including non-metalic PVC casing caping ISI marked with all accessories etc with one run of 6 Sqmm (1x10 Sqmm) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire, sinking of MS boxes and making good to match with existing surfaces complete all as specified and directed by Engineer-in-Charge. Note:- 2 runs of 6Sqmm (2x10 Sqmm), 1 run of 10 Sqmm (1x10 Sqmm) cable and one metre of casing caping will be measured as one unit.
Supply and fixing in replacement of sheet metal enclosure with 20 Amps 240 volt socket plug top and MCBs single polet and neutral enclosure with two pin and earth plug and socket wit hone single pole 20 Amps MCB complete all as specified and directed by Engr-in-Charge. Make: Cat part No 5076 10 of Legrand (Ekinoxe) or as per PS
Supply and Laying jointing and testing in replacement PVC insulated armored heavy duty electric cable with aluminum conductor, 1100 volt grade, cross sectional area 10 Sqmm 2 Core complete all as specified and directed by Engr-in-Charge. Make- As per PS
Supply and Laying jointing and testing in replacement PVC insulated armored heavy duty electric cable with aluminum conductor, 1100 volt grade, cross sectional area 16 Sqmm 2 Core complete all as specified and directed by Engr-in-Charge. Make- As per PS
S&F in repalcement of 4M LED foot light complete all as specified and directed by Engr-in-Charge. Make : As per PS
R B TRADERS
SUMEET TRADING CORPORATION
Horizon Construction Company
VIMAL TRADERS AND SUPPLIERS
M.S Sharma Enterprises
Mehar Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .