Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹35.7 LAccepted-AOC RZ H 5 NANDA BLOCK MAHAVIR ENCLAVE PART 1 PAL AM SOUTH WEST DELHI DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | 1 | Accepted-AOC LOWEST RATE | |
| 2 | 2₹50.4 L+₹14.7 L (41.1%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NEW DELHI | DELHI | DELHI | 110006 | 2 | Rejected-Finance NOT LOWEST |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
10 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) PALAM DELHI CANTT
GE (AF) PALAM DELHI CANTT - 110010
REPAIR/MAINTENANCE OF LT UG CABLES , LT OVERHEAD LINES, LT SWITCH GEARS AND CONNECTED ITEMS AT AF STN PALAM UNDER GE (AF) PALAM, DELHI CANTT-10
2023_MES_580327_1
GENP-72/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (AF) PALAM DELHI CANTT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (AF) PALAM
₹1 L
Yes
15 Jun 2023
10 Feb 2023
11 Mar 2023
10 Feb 2023
10 Mar 2023
25 Feb 2023
Amount
Excavation in trenches in soft/loose soil not exceeding 1.50 Mtrs wide and not exc. 1.5 Mtr deep or not exc 10 Sqm on plan and getting out for taking out/laying cable etc complete.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exc 25 cm thick after the cable have been laid and tested.
Removal of excavated surplus soil to a distance not exc. 50 Mtrs and depositing where directed at a level not exc 1.5 Mtr above the starting point.
M&L for sand cushioning to under ground cable provided with layer of sand (8cm deep before laying the cable and 15 cm deep after laying the cable ie total 23 cm and to be achieved 18cm thickness after punning complete.
M&L for brick laid in trenches for cable protection of burnt clay sub class ‘B’ complete laid dry flat complete.
Laying only old serviceable bricks complete all as specified and directed by Engr-in-Charge.
Taking out old unserviceable LT under ground cable any type from trenches, pipes & poles complete all as specified and directed by Engr-in-Charge.
Relaying of old serviceable LT cables in trenches, pipes and on poles as obtained from item No. 7 above complete all as specified and directed by Engr-in-Charge
Supply, laying and testing for XLPE insulated LT armoured under ground cable 1100 Volt grade with stranded aluminium conductor of size 10 Sqmm 2 Core as in trenches /passing through pipes/ on poles etc complete all as specified and directed by Engr-in-Charge
All as per item No 9 above but 16 Sqmm 2 core.
All as per item No 9 above but 16 Sqmm 4 core.
All as per item No 9 above but 25 Sqmm 4 core.
All as per item No 9 above but 35 Sqmm 3.5 core.
All as per item No 9 above but 50 Sqmm 3.5 core.
All as per item No 9 above but 70 Sqmm 3.5 core.
All as per item No 9 above but 95 Sqmm 3.5 core.
All as per item No 9 above but 120 Sqmm 3.5 core.
All as per item No 9 above but 150 Sqmm 3.5 core.
All as per item No 9 above but 185 Sqmm 3.5 core.
All as per item No 9 above but 240 Sqmm 3.5 core.
Supply & jointing in repair heat shrinkable straight through joint suitable for LT 1100 Volt grade XLPE cable of size 400/500 Sqmm 3.5 core complete with treating of cable to make ready for jointing etc complete.
All as per item No. 21 here in before but suitable for cable size 240 to 300 Sqmm.
All as per item No. 21 here in before but suitable for cable size 150 to 185 Sqmm.
All as per item No. 21 here in before but suitable for cable size 70 to 120 Sqmm.
All as per item No. 21 here in before but suitable for cable size 25 to 50 Sqmm.
M&L for galvanised steel tubing, light grade with all fittings laid in trenches/on floors of 80 mm bore all as specified.
All as per item No 26 above but 100 mm bore
All as per item No 26 above but 150 mm bore
All as per item No 26 above but 50 mm bore
All as per item No 26 above but 40 mm bore
Demolition of cement concrete in PCC poles/steel tubular poles, struts etc of any size all as specified and directed by Engineer-in-Charge.
S&F in repalcement of steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31, 9.00 meter long complete
S&F in replacement of lugs/thimbles at termination of LT cable by cutting the end portion and removing insulation and fixing new aluminium lugs /thimble properly with crimbing tool of size 185 to 400 Sqmm complete
All as per item No. 33 here in before but for cable size 50 to150 Sqmm
All as per item No. 33 here in before but for cable size upto 35 Sqmm
Cutting and trimming of tree branches on any type of surface and height to clear OH lines in the area of LT OH lines feeders (including repairing and jointing of ACSR conductor if damaged during cutting of tree) and removal of the trimmed branches of trees and depositing the same where directed including providing the necessary ropes/cutting tools, safety equipment like helmet etc as per safety norms (IE Rules) all as specified and directed by Engr-in-Charge.
Material and labour for preparation of old painted / rusted surfaces of steel tubular LT pole 9 mtr long inculding cross arms and clamps of any size and applying one coat of aluminum paint (1st quality) including white /blue 30 cm wide strip upto the height of 1.5 mtr above ground level and marking the pole No in 4” dia yellow paint complete all as specified and directed by Engr-in-Charge
M&L for painting to PCC poles of any type and any size with a coat of synthetic enamel paint with white /blue30 cm wide strip upto the height of 1.5 mtr above ground level and marking the pole No in 4” dia yellow paint circle complete all as specified and directed by Engr-in-Charge.
M&L for augering of holes in true horizontal position under road /pavement by means of mechanical rig after doing ultrasound technique to prevent any damage to existing cables/pipe lines coming in route 1.5 Mtr deep and not exceeding 50 Mtrs long including laying HDPE pipe of 150mm dia complete all as specified and as directed by Engr-in-Charge
S&F for MCCB 400 Amps 4 pole 36 KA 415 Volts 50 Hz with thermal and magnetic adjustable settings including taking out old existing unserviceable MCCB from panels etc complete.
All as per item No. 40 here in before but 320/350 Amps 36 KA .
All as per item No. 40 here in before but 250 Amps 36KA.
All as per item No. 40 here in before but 200 Amps 36 KA.
All as per item No. 40 here in before but 160 Amps 36 KA .
All as per item No. 40 here in before but 125 Amps 16 KA .
All as per item No. 40 here in before but 100 Amps 16 KA.
All as per item No. 40 here in before but 63 Amps 16 KA .
M&L for defect rectification LT cable laid in trenches by locating fault with the help of electronic fault locating machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc.including and additional excavation in normal alluvial strata required for exposing the cable fault removal of deteriorated portion of cable treating of cable and keeping the same ready for jointing work for cable of size up to 400 Sq mm 3.5 core. The fault locating equipments will be brought by the contractor to site within the hours of instruction from Engr-in-Charge
S&F in replacement of Vertical type load line distribution board, double door, 8 ways, AC 3 Phase, 415 volts, TPN, bus bar 200 Amps rating and earth bus & din rail suitable for MCCB as incomer complete including cutting chasing the existing wall for fixing the DB and making good the disturbed surface of wall and matching with existing surface of wall and making cable connection with suitable size lugs, making electrical connections of existing submain/circuit wiring, earth wire all as specified and directed by Engr-in-Charge.
Supply and fixing in replacment of MCCB 125 Amp, 3 pole,10KA complete.
Supply and fixing in replacement of MCB SPN, 32 Amp,240V, 10KA 'B' series complete.
Supply and fixing in replacement of MCB, SP,5-32 Amp, 240V, 10 KA 'C' series complete.
Supply and fixing in replacement of MCB, TP, 25 to 63A, 10KA, 415V 'B' series complete.
Supply, installation, testing and commissioning in replacement of out door type cubical panel board suitable for 3 phase, 4 wire, 415V, 50 Hz and tested at CPRI for 35 MVA rapturing capacity at 415 volts factory fabricated in an approved factory with CRCA sheet not less than 3 mm thick having modern fabrication process powder coating in approved shade having thickness not less than 100 microns provided with suitable gasket to make it dust and vermin proof and general construction conforming to IS : 8623/93 and the panel duly supported with suitable size of MS angle iron. The LT panel shall be front and back openable and having inner and outer shells. The inner shells duly compartmentalized for each control gears.The panel should have suitable size of aluminium Bus -bar three phase 4 wire system having current carrying capacity not less than 1.5 times the rated current carrying capacity of the incomer ACB/MCCB. The panel should have the following incoming and out going controlls duly fixed with the panel by means of suitable link plates complete all as specified and as directed by Engineer -in-charge. (The cost of provn of PCC foundation for fixing the panel is deemed to be included in the quoted rate).Location-PINTO PARK MES COLONY LT-1. INCOMING (i) ACB 800A 4 pole ,LT 415V ,65KA breaking capacity with electrical draw out microprocessor release (IPR2 04 Pole) with auxillary switch 6NO+6NC,Main CTs ,safety shutters,36 way auxillary isolating contacts and horizontal terminal type complete - 1 No (ii) Digital Multi functional meter VAFPP (voltage , current , frequency,power factor) - 1 No. (iii) Phase indicator lamp (LED type) - 1 Set.(set of three) OUT GOING:- (i) MCCB 400A, 4 pole ,35 KA with adjustable thermal & fixed magnetic setting – 01 No (ii) MCCB 250A ,4 pole ,35 KA with adjustable thermal & fixed magnetic setting -01 No (iii) MCCB 125 A ,4 pole ,35 KA with adjustable thermal & fixed magnetic setting -01 No (iV) MCCB 100 A ,4 pole ,35 KA with adjustable thermal & fixed magnetic setting -01 No Make of MCCB : Havells/ Legrand/ C&S (iv) Digital type time switch 16 Amps 3P module, DIN 24 hours programmable every 1 minutes with 28 memory -01 No.
Supply, installation, testing and commissioning in replacement of out door type cubical panel board suitable for 3 phase, 4 wire, 415V, 50 Hz and tested at CPRI for 35 MVA rapturing capacity at 415 volts factory fabricated in an approved factory with CRCA sheet not less than 3 mm thick having modern fabrication process powder coating in approved shade having thickness not less than 100 microns provided with suitable gaskit to make it dust and varmin proof and general constructions conforming to IS : 8623/93. The LT panel shall be front and back openable and having inner and outer shells. The inner shells duly compartmentalized for each control gears.The panel should have suitable size of aluminium Bus -bar three phase 4 wire system having current carrying capacity not less than 1.5 times the rated current carrying capacity of the incomer ACB/MCCB. The panel should have the following incoming and out going controlls duly fixed with the panel by means of suitable link plates complete all as specified and as directed by Engineer -in-charge. (PCC platform of suitable size for mounting the LT panel is deemed to be included in the quoted rate ) RV AREA LT-1 INCOMING (i) MCCB 400A, 4 pole ,50KA with adjustable thermal & adjustable magnetic setting - 1 No (ii) Digital Multi functional meter VAFPP (voltage , current , frequency,power factor) - 1 No. (iii) Phase indicator lamp (LED type) - 1 Set.(set of three) OUT GOING:- (i) MCCB 250A 4 pole ,35 KA with adjustable thermal & fixed magnetic setting – 01 No (ii) MCCB 160A ,4 pole ,35 KA with adjustable thermal & fixed magnetic setting -01 No (iii) MCCB 125 A ,4 pole ,35 KA with adjustable thermal & fixed magnetic setting -02 No (iV) MCCB 63 A ,4 pole ,25 KA with adjustable thermal & fixed magnetic setting -01 No Make of MCCB : Havells/ Legrand/ C&S (iv) Digital type time switch 16 Amps 3P module, DIN 24 hours programmable every 1 minutes with 28 memory -01 No
Supply and fixing in replacement of outdoor type cubical Feeder pillar box 1200x1000x600mm size suitable for 3 phase, 4 wire, 415V, factory fabricated with CRCA sheet not less than 3 mm thick having modern fabrication process powder coating in approved shade provided with suitable gasket to make it dust and vermin proof and the panel should have 1000 Amps aluminium Bus bar three phase & neutral mounted on insulators mounted on angle iron frame 40mmx40mmx5mm including PCC foundation in 1:2:4 type B-1 complete all as directed by Engineer -in-charge.
Supply and fixing in replacement of outdoor type cubical Feeder pillar box 750x500x450mm size suitable for 3 phase, 4 wire, 415V, factory fabricated with CRCA sheet not less than 3 mm thick having modern fabrication process powder coating in approved shade provided with suitable gasket to make it dust and vermin proof and the panel should have 1000 Amps aluminium Bus bar three phase & neutral mounted on insulators mounted on angle iron frame 40mmx40mmx5mm including PCC foundation in 1:2:4 type B-1 complete all as directed by Engineer -in-charge.
Supply and fixing in replacement of outdoor type cubical Feeder pillar box 600x500x450mm size suitable for 3 phase, 4 wire, 415V, factory fabricated with CRCA sheet not less than 3 mm thick having modern fabrication process powder coating in approved shade provided with suitable gasket to make it dust and vermin proof and the panel should have 1000 Amps aluminium Bus bar three phase & neutral mounted on insulators mounted on angle iron frame 40mmx40mmx5mm including PCC foundation in 1:2:4 type B-1 complete all as directed by Engineer -in-charge.
M&L in replacement of earthing with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mtr below ground level) with top edge of earth plate not less than 1.5 Mtrs below ground level connected to GI strip 32x6mm as earth lead by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel including concrete chamber with PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish internal surface of concrete chamberwith 15mm thick plaster in CM 1:4, funnel with wire gauge mesh, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified including provision of GI strip protected by 40 mm dia medium grade pipe and watering pipe shall be 20mm bore medium grade, and including all excavation and earth work & connecting the earthing to an earthing test point complete.
M&L in replacement of earthing with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mtr below ground level) with top edge of earth plate not less than 1.5 Mtrs below ground level connected to GI strip 25x6mm as earth lead by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel including concrete chamber with PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish internal surface of concrete chamberwith 15mm thick plaster in CM 1:4, funnel with wire gauge mesh, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) and specified including provision of GI strip protected by 40 mm dia medium grade pipe and watering pipe shall be 20mm bore medium grade, and including all excavation and earth work & connecting the earthing to an earthing test point complete.
M&L in replacement of earthing with galvanized steel earth plate electrode 60cm x 60cmx 6.3 mm thick buried directly in ground ( earth pit not less than 2.25 meter deep below ground level) with the top edge of the earth plate not less than 1.5 meter below normal ground level connected to galvanized earth lead wire 4mm dia by means of bolts, nuts, check nuts and washer of galvanized iron or of steel all as shown in electrical plate No.3 of MES SSR parts-I of 2009 and including excavation & earth work in any type of soil , disposal of soil , providing alternate layers of charcoal and common salt, construction of PCC earth chamber in mix 1:3:6 type c-1 with 40 mm thick RCC 1:2:4 type B-I cover reinforced with 8mm dia TMT bars both ways with lift hook made out of 8 mm dia bar, watering arrangement with funnel and wire mesh and watering pipe of 20mm dia GI light grade and 15mm dia light grade pipe for earth lead protection and testing on completion complete all as specified and directed by Engr-in-Charge.
M&L for cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation poles/struts with necessary form work complete.
M&L for cement concrete 1:3:6,type C-2 using 40 mm graded stone aggregate for foundation of pole/ stay assembly including frame work with necessary form work complete.
M&L for cement concrete 1:2:4, type B-1 using 20 mm graded stone aggregate as in padestal/coping of poles finished even and fair with necessary form work complete.
M&L for welding hinges to existing panel board with existing shutters and fixing to panel board complete.
M&L for replacement of shutter of panel with 3 mm thick CRCA sheet as per exisitng size to match with the existing panel and welding hinges and fixing complete.
M&L for painting of existing LT panel board with spray gun with synthetic enamel paint to match with the existing colour/surface complete.
S&F in replacement of glands for cable upto 240 Sqmm size double compression type complete including removing and refixing cables from LT panel for fixing the glands all as specified and as directed by Engineer-in -charge.
S&F in replacement of analog type time switch 3P module, DIN 24 hours programmable every 30 minutes of current capacity 16 Amps with one change over including connecting to existing power contactor complete.
S&F in replacement of degital type time switch 3P module, DIN 24 hours programmable every 1 minutes with 28 memory location of current capacity 16 Amps with one change over including connecting to existing power contactor complete all as specified and as directed by Engineer-in -charge.
S&F in replacement of RYB indicator LED type capacity complete .
M&L in replacement of PVC insulated service cable flat or round sheathed, aluminium, multistranded conductor 1100V grade size 16 Sqmm 2 Core.
All as per item No. 73 above but 10 Sqmm 2 core.
M&L in replacement of Junction box outdoor type, 3 phase 415 Volts of size 350x250x150 mm made out of hot press moulded SMC front openable hinged type including 4 Nos. Al bus bars mounted on insulators heavy duty of rating 32 Amps with necessary fixing arrangements to pole with MS calmps, nuts, bolts etc of size 25 x 4 mm duly painted with two coats of synthetic enamel paint over a coat of primer complete all as specified and as directed by Engineer-in -charge.
M&L in replacement Junction box outdoor type, single phase 230 Volts of size 300x200x105 mm made out of hot press moulded SMC front openable hinged type including 2 Nos. Al bus bar mounted on insulators heavy duty of rating 32 Amps with necessary fixing arrangements to pole with MS calmp, nuts, bolts etc of size 25 x 4 mm duly painted with two coat of synthetic enamel paint over a coat of primer complete all as specified and as directed.
Supply and fixing in replacement of ACB 1000 A, 4 Pole, LT 415 V, 65 KA breaking capacity with Electrical draw out, Micro processor release (IPR2 04 Pole) with auxiliary switch 6NO+6NC, Main CTs, safety shutters, 36 way auxiliary isolating contacts and horizontal terminal type complete including disconnecting and taking down the existing unserviceable ACB any type and making necessary electrical connections including making necessary fixing arrangements in the existing panel complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of ACB 800 A, 4 Pole, LT 415 V, 65 KA breaking capacity with Electrical draw out, Micro processor release (IPR2 04 Pole) with auxiliary switch 6NO+6NC, Main CTs, safety shutters, 36 way auxiliary isolating contacts and horizontal terminal type complete including disconnecting and taking down the existing unserviceable ACB any type and making necessary electrical connections including making necessary fixing arrangements in the existing panel complete all as specified and directed by Engr-in-Charge.
M&L for preparation of old painted chain link/barbed wire fencing/gate/angle iron/post of sub station (outer exposed surface) and GI bracket/clamps with bolts, nuts and applying two coats of aluminium paint including writing substation details with black colur of existing size letters all as specified and as directed.
M&L for cutting existing road / foot path of bituminous macadam /PCC on foot path for laying protection pipe for cable and making good the disturbed surfaces in cement concrete 1:2:4 type B-1 all as required and directed by Enge-in-charge. Note: PCC wil be measured and paid seperately
M&L for spreading stone agregate 40mm size for transformer yard/ HT 2 poe/4 pole stucture after preparing the surrounding by brick work and removing the vegetation and making brick work in CM 1:4 and necessary surface excevation and spreading of layer of sand all as specified and as directed. (Note:- Earth work; brick work, sand etc shall be measured and paid seperately)
Repairs to the existing earthing complete by replacing the unserviceable GI strip, bolt, nut, check nut and washer, earthing test point all as specified including testing on completion including making PCC chambers, RCC cover, GI funnel for watering, GI funnel, earth strip protection pipe including 10 kgs of salt and watering, testing of earth result by megger and submitting the report etc all as specified and as directed including writting and painting of earthing details (Note: The rate for excevation and all materials is inclussive in the quoted rate of item except Earth strip and protection pipe will be measured and paid seperately )
S&F in repair GI strip 32 x 6 mm as in earth continuity conductor or main earthing lead buried in ground or drawn through pipes or fixed to wall or poles or any other situation for loop earthing etc as required and all as directed.
S&F in repair GI strip 25 x 4 mm as in earth continuity conductor or main earthing lead buried in ground or drawn through pipes or fixed to wall or poles or any other situation for loop earthing etc as required and all as directed.
S&F in repair GI strip 25 x 3 mm as in earth continuity conductor or main earthing lead buried in ground or drawn through pipes or fixed to wall or poles or any other situation for loop earthing etc as required and all as directed.
M&L in repair earth marking plate made out of mild steel plate 3 mm thick of size 200mm x100 mm fixed on angle iron 25x25x 6 mm 400mm long grounded in PCC 1:3:6 type C-1 near earth pit and steel surfaces duly painted with two coats of synthetic enamel paint over a coat of red oxide primer including necessary marking earth No. equipment connected,tested on date results in ohms etc all as directed by Engr - in - charge.
S&F in repair danger notice plate made of 1.6mm thick mild steel sheet vitreous enamelled white with letters figures and conventional skull and in bones in signal red colour fixed with MS clamps bolts and nuts of approved size for LT/HT of 25 cm x 20cm size
Supply, installation, testing and commissioning in replacement of out door type cubical panel board suitable for 3 phase, 4 wire, 415V, 50 Hz and tested at CPRI for 35 MVA rapturing capacity at 415 volts factory fabricated in an approved factory with CRCA sheet not less than 3 mm thick having modern fabrication process powder coating in approved shade having thickness not less than 100 microns provided with suitable gaskit to make it dust and varmin proof and general constructions conforming to IS : 8623/93. The LT panel shall be front and back openable and having inner and outer shells. The inner shells duly compartmentalized for each control gears.The panel should have suitable size of aluminium Bus -bar three phase 4 wire system having current carrying capacity not less than 1.5 times the rated current carrying capacity of the incomer ACB/MCCB. The panel should have the following incoming and out going controlls duly fixed with the panel by means of suitable link plates complete all as specified and as directed by Engineer -in-charge. (PCC platform of suitable size for mounting the LT panel is deemed to be included in the quoted rate ) INCOMING (i) MCCB 400A 4 pole ,50KA with adjustable thermal & adjustable magnetic setting - 1 No (ii) Digital Multi functional meter VAFPP (voltage , current , frequency,power factor) - 1 No. (iii) Phase indicator lamp (LED type) - 1 Set.(set of three) OUT GOING:- (i) MCCB 125A 4 pole ,35 KA with adjustable thermal & fixed magnetic setting – 02 Nos (ii) MCCB 100A ,4 pole ,35 KA with adjustable thermal & fixed magnetic setting -04 Nos Make of MCCB : Havells/ Legrand/ C&S (iv) Digital type time switch 16 Amps 3P module, DIN 24 hours programmable every 1 minutes with 28 memory with suitable MCB control-01 No.
Supply, installation, testing and commissioning in replacement of out door type cubical panel board suitable for 3 phase, 4 wire, 415V, 50 Hz and tested at CPRI for 35 MVA rapturing capacity at 415 volts factory fabricated in an approved factory with CRCA sheet not less than 3 mm thick having modern fabrication process powder coating in approved shade having thickness not less than 100 microns provided with suitable gaskit to make it dust and varmin proof and general constructions conforming to IS : 8623/93. The LT panel shall be front and back openable and having inner and outer shells. The inner shells duly compartmentalized for each control gears.The panel should have suitable size of aluminium Bus -bar three phase 4 wire system having current carrying capacity not less than 1.5 times the rated current carrying capacity of the incomer ACB/MCCB. The panel should have the following incoming and out going controlls duly fixed with the panel by means of suitable link plates complete all as specified and as directed by Engineer -in-charge. (PCC platform of suitable size for mounting the LT panel is deemed to be included in the quoted rate ) INCOMING (i) MCCB 250A 4 pole ,50KA with adjustable thermal & adjustable magnetic setting - 1 No (ii) Digital Multi functional meter VAFPP (voltage , current , frequency,power factor) - 1 No. (iii) Phase indicator lamp (LED type) - 1 Set.(set of three) OUT GOING:- (i) MCCB 100A 4 pole ,35 KA with adjustable thermal & fixed magnetic setting – 04 Nos (ii) MCCB 63A ,4 pole ,35 KA with adjustable thermal & fixed magnetic setting -01 Nos Make of MCCB : Havells/ Legrand/ C&S (iv) Digital type time switch 16 Amps 3P module, DIN 24 hours programmable every 1 minutes with 28 memory with suitable MCB control-01 No.
Supply and fixing in replacement of Ruby clear post top 25W LED, 5700K new generation energy saving & environmental friendly, long life versatile aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs light source IP 65 complete.
S&F in repalacement of street light bracket made out of 40 mm dia light grade GI pipe bend to shape 1.2 m long with 02 Nos clamp made out of 25 x 6mm GI strip including drilling holes bending welding and made to clampes on building/concrete/rail/tubular pole.
S&F in repalacement of MCB, TPN, 32 Amp to 40 Amp, 415V complete.
Supply only power contactor 3 phase, MNX 650 series of Make L&T or equivalent in Seimens/Havells complete.
Supply and fixing in replacement of LED street light fitting of 90 Watt, 5700K complete including all fixing accessories complete made up of pressure die cast aluminium housing with high power LED as lighting source and lens with heat resistant toughened glass & IP 66 protection with 10 KV built-in surge protection device complete with driver and all accessories fixed on and including GI bracket of sufficient length and size with all nuts, bolts, washers etc duly connection with & including three core flexible copper cable complete all as specified and as directed by Engr-in-Charge
Supply only power contactor 3 phase, 32A/40A MNX A2 series of Make L&T or equivalent in Seimens/Havells.
Dismantling posts or struts (wood steel or RCC) any section including taking out embeded portion of concrete and making good disturbed in ground
Dismantling of old chain link/barbed fencing of any size or mesh.
Dismanlting of wrought iron or mild steel work of any description not otherwise provided for.
M&L for cement concrete 1:2:4 type B,2 using 40mm graded stone aggregate as in posts and pillars etc complete.
S&F for hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165
M&L for synthetic enamel paint over a coat of red oxide primer including preparation of newely steel and iron surfaces of any description over 10cm in width or grith.not otherwise described.
S&F for chain link fencing 4mm dia galvanised steel wire 150x100mm mesh including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire.
Commercial Traders
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .