Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.8 LAccepted-AOC | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹14.8 L+₹50,425 (3.52%)Rejected-Finance 74 103 DHANKUTTI KANPUR 208001 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208001 | L2 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 3 | L3₹15.3 L+₹93,580 (6.54%)Rejected-Finance | L3 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 4 | L4₹15.4 L+₹1.1 L (7.79%)Rejected-Finance | L4 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 5 | L5₹15.8 L+₹1.4 L (10.1%)Rejected-Finance | L5 | Rejected-Finance HIGHER THAN L1 BIDDER |
Tender Value
₹30.0 L
EMD Value
₹60,090
Closing Date
21 Feb 2022, 6:00 pmClosed
GE I KANPUR
GE I Kanpur Cariappa Road Cantt Kanpur 208004
COMPREHENSIVE MAINT/ PETTY REPAIR OF INTERNAL ELECTRICAL COMPLAINTS AND INTERNAL WIRING AND CONNECTED ITEMS IN DGQA AREA UNDER GE(I) KANPUR
2022_MES_506004_1
GE(I)/KAN/T-69 OF 2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE I KANPUR
Class D Cat b i
8 documents required · 8 mandatory
₹500
GE I KANPUR
₹60,090
Yes
9 Apr 2022
5 Feb 2022
28 Feb 2022
5 Feb 2022
21 Feb 2022
15 Feb 2022
Amount
Attending complaints fo checking and replaceing the existing defective electrical items for continuous electric supply including carrying out minor repair as required to make the item functional and replacing fuse, small pieces of copper wire, copper cable as of suitable size at site, insulation tape roll etc. attending minor repair(s) such as testing, connectins, fittings, nut, bolts, screws etc to emergent complaints i.e no light, earth leakage, short circuit, neutral break in mains/sub mains/internal circuits of existing electical system of main building/block and making continuous electric supply including carrying out minor repairs etc.. required to make the system in order/*functional with insualtion tape roll, copper thimbles, glands, earthing wire as required at site complete all as specified and directed by Engineer-in-Charge. Notes :- This item is applicable only where no store is required. 1. The site for attending complaints at DGQA Area. Contractor shall provide minimum one tradesmen (electrician) for each site to attend the complaint in all working days between 0830 hrs to 1700 Hrs including holiday and Sunday. 2. Contractor shall ensure the security passess for his staff, to be obtained from concern authority for attending complaints. 3. The contractor will ensure that the electicians with necessary tools bag shall always remain present at complaint cell to attend the Complaints. 4. A recovery of Rs 500/- for not attending the complaint upto 04 hours and after 04 hours Rs 1000/- shall be recovered from the contractor due 5. All the complaint slip, register & other connected document will be provided by the contractor without any extra cost. 6. Proper record (date wise) of complaints received & rectified by the contractor and the same may be asked for verification at the time of payment of each RAR/Bill. 7. The above tradesmen shall not be utilize for the complaints where material is required and these complaint shall be measured and paid seperately as S&F here in after.
Supply and fix in replacement cable PVC insulated unsheathed with flexible multistranded copper conductor of size 0.75 Sqmm.
All as per item No 2 above but size 1.5 Sqmm and all as specified and directed.
All as per item No 2 above but size 2.5 Sqmm and all as specified and directed.
All as per item No 2 above but size 4 Sqmm and all as specified and directed.
All as per item No 2 above but size 6 Sqmm and all as specified and directed.
All as per item No 2 above but size 10 Sqmm and all as specified and directed.
M&L for switch piano flush button single pole one way 5 amps 240 volts and all as specified and directed.
Switch piano flush button single pole one way 15 amps 230 Volts and all as specified and directed.
M&L for socket 5 amps 5 pin flush type, 230 volts. and all as specified and directed.
M&L for socket out let, 6 pin 5 and 15 amps multi purpose 2 in 01 flush type, 230 volts and all as specified and directed.
M&L for bell push flush button single pole one way 5 amps 240 volts and all as specified and directed.
M&L forelectric bell heahy dutyding dong/buzzer type AC 230 volts single pole complete and all as specified.
M&L for switch modular type single pole one way 1 module 6 amps 240 volts and all as specified and directed.
Switch modular type one way 1 module 16 amps 230 Volts and all as specified and directed.
M&L for socket 6 amps modular type 2/3 pin combined 2 module , 230 volts as per sample and all as specified and directed.
M&L for socket modular type , 2/3 pin, 6 and 16 amps combined 2 module, 230 volts. as per sample and all as specified and directed.
S & F modular white cover plate with frame 2/3 module all as specified and directed. as per sample and all as specified and directed.
S & F modular white cover plate with frame 4 module all as specified and directedas per sample and all as specified and directed.
S & F modular white cover plate with frame 6 module all as specified and directed as per sample and all as specified and directed.
S & F imodular white cover plate with frame 8 module all as specified and directedas per sampleand all as specified and directed.
S & F modular white cover plate with frame 12 module all as specified and directed.as per sample and all as specified and directed.
M&L for ceiling rose surface bakelite 3 terminals and all as specified and directed.
S & F Lamp holder insulated body with back plate for dome batten fittings and all as specified and directed.
Supply and fixing in replacement fan regulator electronic, step type hum free suitable to control speed of fan from 0 to 100% and connecting electrically all as required or and all as specified and directed.
Supply and fixing in replacement modular regulator as per sample all as required and all as specified and directed.
Supply and fixing in replacement plug top 3 pin 16 amps AC 240 Volts and all as specified and directed.
Supply and fixing in replacement plug top 3 pin 6 amps AC 240 Volts and all as specified and directed.
Supply & fix in replacement hylem sheet cover 3 mm thick of size 7"x4" all as required at site including drilling holes for fixing screws and providing 4 Nos screws with washers for fixing the sheet to sunken box /wooden box and all as specified and directed.
All as per item No-29 above but of size 8"x10" and all as specified and directed.
All as per item No-29 above but of size 11"x9".and all as specified and directed.
All as per item No-29 above but of size 13"x11" and all as specified and directed.
S&F in repair sunken box size 8"x10" and making good disturbed surface to match with the existing surface of wall by applying putty and applying colour / white wash finish complete all as specified and directed.
S&F in repair sunken box size 7"x4" and making good disturbed surface to match with the existing surface of wall by applying putty and applying colour / white wash finish complete all as specified and directed.
Supply and fix LED Alumimium batten luminaire surface mounted, 4 feet system wattage of 20/22 Watts with lifetime of not less than 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 20%, , surge protection 3KV in CM, IP-20n Protected, meets LED IS specifications, Class-1, Short circuit and over circuit protection, voltage range-150 to 270 Vots AC, System effiency at luminaire lelvel > 100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixe complete all as pecified and directed by Engr-in-charge. Note:- All the above mentioned specifications will be verifed through LM 79 and LM 80 report of NABL accredited lab before supply of LED fixtures and all as specified and directed.
S & F in replacement of LED post top lantern 35/40 Watt warm white made in die cast aluminium housing with decorative clear opal acrylic diffuser and IP-65 protection fixing with proper arrangements and making electrical connection and all as specified and directed.
S & F in replacement of LED post top globestarmade up of unbreakable polycarcarbonate suitable for mounting on gate with led bulb 12 W with proper arrangements and making electrical connection complete and all as specified and directed.. Make :Surya Cat Part No SLE PT 12W-GS250 or equivalent in Wipro/Bajaj/havells
Supply and fix LED alumimium batten luminaire surface mounted, 2 feet system wattage of 10 Watts with lifetime of not less than 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 20%, , surge protection 3KV in CM, IP-20n Protected, meets LED IS specifications, Class-1, Short circuit and over circuit protection, voltage range-150 to 270 Vots AC, System effiency at luminaire lelvel > 100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixe complete all as pecified and directed by Engr-in-charge. Note:- All the above mentioned specifications will be verifed through LM 79 and LM 80 report of NABL accredited lab before supply of LED fixtures.
S&F in replacement of LED light fitting recess mounted 36 Watt, 1' x 4' with all accessories suitable for amstrong/grid/POP ceiling complete with integrated electronic driver and making electrical connection with making electrical connection with three core copper wire to ceiling rose properly and all as specified and directed..
S&F in replacement of LED light fitting recess mounted 31/32 Watt, 2' x 2' with all accessories suitable for amstrong/grid/POP ceiling complete with integrated electronic driver and making making electrical connection with making electrical connection with three core copper wire to ceiling rose properly and all as specified and directed.
Supply and fixing 10W surface mounted IP65 Bulkhead with system efficiency of 100LM/Watt LED bulk head shall be made up of Die cast Aluminium housing for better heat decapitation.P.F>.95with THD <10%,surge protection 4KV input voltage rane 150Vto 270V including connecting electricaly to ceiling rose using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm all as required.
M&L for sheet metal enclosure MCB distribution board single pole and neutral with a two pin and earth plug and socket 25 amps 240 volts, complete with one single pole MCB of 25 amps earthing and all as specified and directed.
M&L for RCCB Ac type Double pole 240 volts 16 to 63 amps, with rupturing capacity 10 KA using thimbles of required size and all as specified and directed.
Supply and fix sheet metal enclosure MCB distribution board, double door with IP-43 protection with acrylic cover single phase 240 volts 4 way, including suitable size copper bus bar and neutral link of make Legrand or equivalent of make Havells/L&T fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification and all as specified and directed.
All as per srl item No 44 above but for 8 way and all as specified and directed.
M&L for MCB single pole 240 volts 5 to 30 amps, with rupturing capacity 10 KA using thimbles of required size and all as specified and directed.
M&L MCB single pole & neutral 240 volts 32 amps,with rupturing capacity 10 KA using thimbles of required size.
All as per item No 47 above but of size 63 Amps and all as specified and directed.
Supply and fix in replacement of LED Wall Security light 25 Watt IP 66 Energy saving & environmental friendly long life pressure die-cast aluminium housing for better heat decapitation efficiency not less than of 100LM/Wat ,P.F>.95with THD <10%,surge protection 4KV input voltage rane 150Vto 270V incl suitable size service bracket fixed with clamps, nut, bolt and washer and electric connection with 1.5 Sqmm multistranded twin core alum cable PVC insulated and all as specified and directed.
S & F distribution board iron clad, double door with IP-43 1K-09 protection suitable for MCCB as incommer and MCB as outgoing 415 Volts 3 phase 50 C/s 4 way, complete with appropriate size copper bus bar and neutral link, confirming to cat pt No 607913 of Legrand or equivalent of make Havells complete with one MCCB 3 pole 415 Volts 100 Amps rating with rupturing cap 16 KA of the same make as of distribution board & with MCBs of required size making connection with thimbles & including cutting chases to wall for fixing DB and making good the disturbed wall surface all as required at site and all as specified and directed.
S & F switch socket combination 2 in 1, 3 pin, 5 Amp flush type universal with complete box all as specifid and directed
S & F switch socket combination 2 in 1, 3 pin,15 Amp flush type universal with complete box and all as specified and directed.
S & F Switch socket combination 2in 1, 5 A flush types all as specifid and directed
S & F Switch socket combination 2in 1, 15 A flush types all as specifid and directed
S & F of led Bulb of 09 Watt cool day light eco friendly energy efficient all as specified and directed.
S & F of LED polycarbonate T8 with in built driver with metal heat sink double sided connection 20 W with suitable and making all electric connection all as specified and directed.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting, bell, bell push etc and making good disturbed surfaces of walls, floor to match with existing specification complete and all as specified.
Point wiring for one light point/fan/bell point controlled by one switch with 1.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable FRLS with proper color coding and 1.5 sqmm PVC insulated unsheathed copper conductor single core multistranded cable (green color) as earth lead in and including concealed non metalic rigid PVC conduit medium grade size 25mm dia with all fittings (ISI Marked) controlled by one switch including CI/MS sunk box of required size & as directed & 3 mm thick plastic laminated sheet, including cutting chases to wall making good the disturbed surfaces to match with the existing specification complete all as specified.
All as per srl item No-58 here in above but upto ceiling height and on surface at ceiling and all as specified and directed.
All as per srl item No-58 here in above but in existing conduitand all as specified and directed.
All as per srl item No-58 here in above but for one 3 pin 15 Amps socket outlet independent with 2.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable and 2.5 sqmm PVC insulated unsheathed copper conductor single core cable (green color) as earth lead in and incl conduit and all as specified and directed.
All as per srl item No-58 here in above but for one 3 pin 15 Amps socket outlet independent with 2.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable and 2.5 sqmm PVC insulated unsheathed copper conductor single core cable (green color) as earth lead in existing conduit.
All as per srl item No-58 here in above but for one 3 pin 5A socket outlet independent controlled by one switch.
All as per srl item No-58 here in above but for one 3 pin 5A socket outlet independent controlled by one switch in existing conduit and all as specified and directed.
All as per srl item No-58 here in above but for one 5A socket outlet on the same board controlled by one switch and all as specified and directed.
All as per srl item No-58 here in above but for one 5A socket outlet on the same board controlled by one switch in existing conduit and all as specified and directed.
All as per srl item No-58 here in above but for one light point controlled by 2 nos two way switches and all as specified and directed.
All as per srl item No-58 here in above but for one light point controlled by 2 nos two way switches in existing conduit and all as specified and directed.
All as per srl item No-58 here in above but for one light/fan/bell point including pressed steel terminal modular boxes of appropriate size and top cover with suitable size of modular plate with all accessories and all as specified and directed.
All as per srl item No-58 here in above but for one socket outlet 5 amps on indipendent board including pressed steel terminal modular boxes of appropriate size and top cover with suitable size of modular plate with all accessories and all as specified and directed.
All as per srl item No-58 here in above but for one socket outlet 5 amps on same board including pressed steel terminal modular boxes of appropriate size and top cover with suitable size of modular plate with all accessories and all as specified and directed.
All as per srl item No-58 here in above but for one light point controlled by two, two way switches including pressed steel terminal modular boxes of appropriate size and top cover with suitable size of modular plate with all accessories and all as specified and directed.
All as per srl item No-58 here in above but for one 3 pin 15 Amps socket outlet independent with 2.5 sqmm PVC insulated unsheathed copper conductor single core multi strand flexible cable and 2.5 sqmm PVC insulated unsheathed copper conductor single core cable (green color) as earth lead in and including pressed steel terminal modular boxes of appropriate size and top cover with suitable size of modular plate with all accessories and all as specified and directed.
M&L in replacement for submain wiring with two single core PVC insulated flexible copper conductor multistranded cable (FRLS) of size 4 sqmm with proper color coding and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 4 Sqmm as earth lead in & including concealed PVC conduit medium grade 25mm dia cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification all as required at site or directed.
All as per srl item No-74 here in above but in existing concealed conduit and all as specified and directed.
All as per srl item No-74 here in above but for cable of size 6 sqmm and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 6 Sqmm as earth lead in & including concealed PVC conduit and all as specified and directed.
All as per srl item No-74 here in above but for cable of size 6 sqmm and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 6 Sqmm in existing concealed conduit with earth wire 4 sqmm and all as specified and directed.
All as per srl item No-74 here in above but for cable of size 10 sqmm and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 6 Sqmm in & including concealed PVC conduit.
M&L in replacement for submain wiring with four single core PVC insulated flexible copper conductor multistranded cable (FRLS) of size 10 Sqmm with proper color coding and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 6 Sqmm as earth lead in & including concealed PVC conduit medium grade 32mm dia cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification all as required at site or directed by Engr-in- charge. Make of Cable : L&T, Havells, Polycab and Make of Conduit : Havells/Kamplast/Polycab and all as specified and directed.
All as per srl item No-79 here in above but for cable of size 16 sqmm aand one single core PVC insulated flexible copper conductor multistranded cable green colour of size 10 Sqmm as earth lead in & including concealed PVC conduit and all as specified and directed.
All as per srl item No-79 here in above but for cable of size 25 sqmm and one single core PVC insulated flexible copper conductor multistranded cable green colour of size 16 Sqmm as earth lead in & including concealed PVC conduit 40mm dia and all as specified and directed.
Supply and laying to wall or poles or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium multistranded conductor 10 sq. mm nominal cross section twin core for service connections all as required and directed.
All as per srl item No 82 but cable of size 6 Sqmm 2 core and all as specified and directed.
All as per srl item No 82 but cable of size 16 Sqmm 2 core and all as specified and directed.
M&L in replacement of earthing complete with galvanised cast iron earth plate electrode of size 600x600x6mm thick as earth electrode with top edge of the earth plate not less than 1.5mtr below ground level using GI wire 4mm dia as earth continuity conductor connected to earth plate by means of GI thimbles nuts bolts washers all as directed including providing earth wire protection pipe GI light grade15mm dia from earth plate to main switch board/panel, watering pipe 20mm dia with wire mesh and funnel at top, earth pit and RCC pit cover in PCC 1:3:6 adequate quantity of charcoal dust and salt all around the erth plate, earth work in any type of soil remaing surplus excavated material all as required at site and specified in EP No 5 of SSR part I 1991 or directed by and all as specified and directed.
Himanshu Construction and Suppliers
M/s A S Electrical
M/S G S Gupta and Sons
YS CONSTRUCTION
DEO Traders
PAWAN COOL CORPORATION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .