| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹2.0 CrAccepted-AOC WARD NO 3 RAM NAGAR PO PS DHEMAJI DIST DHEMAJI ASSAM PIN 787057 | DHEMAJI | ASSAM | 787057 | ₹2.0 Cr | 1 | Accepted-AOC ACCEPTED |
| 2 | 2₹2.0 CrRejected-AOC ASSAM AS | KOKRAJHAR | ASSAM | 783331 | ₹2.0 Cr | 2 | Rejected-AOC REJECTED |
| Sl No | Description | Qty | Unit | KUSHAL KONCH L1 | DHRUBA JYOTI SAIKIA L2 |
|---|---|---|---|---|---|
| 1.01 | Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not| exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within al lead of 50 m. 2.9.1 Ordinary rock | 370.42 | Cum | 537 ₹2.0 L | 537 ₹2.0 L |
| 1.02 | Supplying and fling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete | 831.95 | Cum | 2,217 ₹18.4 L | 2,217 ₹18.4 L |
| 1.03 | Brick on edge flooring with bricks of class designation 7.5 on a bed of
12 mm cement mortar, including filling the joints with same mortar, with common burnt clay non modular bricks: 11.1.1 1:4 (1 cement: 4 coarse sand) | 1,009.11 | SQM | 961 ₹9.7 L | 961 ₹9.7 L |
| 1.04 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering Allwork up to plinth level: 4.1.2 1:1/2:3 (1 Cement: 1 1/2 coarse sand (zone III) derived from natural sources :3 graded stone aggregate 20 mm nominal size derived from natural sources) | 9.95 | Cum | 7,986 ₹79,460.70 | 7,986 ₹79,460.70 |
| 1.05 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded
stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.
11.3.1 40 mm thick with 20 mm nominal size stone aggregate | 831.95 | SQM | 559 ₹4.7 L | 559 ₹4.7 L |
| 1.06 | Providing and laying damp-proof course 40mm thick with cement
concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) | 41.52 | SQM | 380 ₹15,777.60 | 380 ₹15,777.60 |
| 1.07 | Providing and laying in position specified grade of reinforced cement
concrete, excluding the cost of centering, shuttering, finishing and
reinforcement - All work up to plinth level :
5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de
rived from natural sources) | 162.53 | CUM | 8,582 ₹13.9 L | 8,582 ₹13.9 L |
| 1.08 | Reinforced cement concrete work in walls (any thickness), including
attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :
5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size
derived from natural sources) | 81.82 | CUM | 10,450 ₹8.6 L | 10,450 ₹8.6 L |
| 1.09 | Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass
concrete | 426.34 | SQM | 316 ₹1.3 L | 316 ₹1.3 L |
| 1.10 | Centering and shuttering including strutting, propping etc. and removal of form for : 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers | 986.09 | SQM | 624 ₹6.2 L | 624 ₹6.2 L |
Tender Value
₹1.9 Cr
EMD Value
₹3.9 L
Closing Date
11 Dec 2025, 3:00 pmClosed
SUPERINTENDING ENGINEER
LAKHIMPUR BUILDING CIRCLE, NORTH LAKHIMPUR
Construction of shed for Audience at Matmora under Dhakuakhana Sub-Division, North Lakhimpur
2025_PWBNH_48772_1
LBCNL/2025-26/Lakhimpur/CAD
Open Tender
Civil Works - Building
365 days
LAKHIMPUR BUILDING CIRCLE, NORTH LAKHIMPUR
Please refer Tender documents.
4 documents required · 4 mandatory
₹3,880
₹3.9 L
Yes
LAKHIMPUR BUILDING CIRCLE, NORTH LAKHIMPUR
27 Mar 2026
20 Nov 2025
11 Dec 2025
20 Nov 2025
11 Dec 2025
20 Nov 2025
2 Dec 2025
Excavation work by mechanical means (Hydraulic excavator)/ manual means in foundation trenches or drains (not| exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within al lead of 50 m. 2.9.1 Ordinary rock
Supplying and fling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete
Brick on edge flooring with bricks of class designation 7.5 on a bed of 12 mm cement mortar, including filling the joints with same mortar, with common burnt clay non modular bricks: 11.1.1 1:4 (1 cement: 4 coarse sand)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering Allwork up to plinth level: 4.1.2 1:1/2:3 (1 Cement: 1 1/2 coarse sand (zone III) derived from natural sources :3 graded stone aggregate 20 mm nominal size derived from natural sources)
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 11.3.1 40 mm thick with 20 mm nominal size stone aggregate
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for : 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for : 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand)
15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix : 13.8.1 1:3 (1 cement: 3 fine sand)
20 mm cement plaster of mix : 13.6.1 1:4 (1 cement: 4 coarse sand)
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 12.1.3 0.63 mm thick with zinc coating not less than 275 gm/ m²
Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete. 12.4.2 0.63 mm thick with zinc coating not less than 275 gm/m²
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Plastic chair with Iron Frame including fitting, fixing, labour charges etc
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. GROUP C
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.4 X 10 sq. mm + 2 X 6 sq. mm earth wire
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 1.20.1 : 20 mm
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 A switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 A socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 A socket outlet
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way , Double door
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 2.5.1 4 way (4 + 12), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 A
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq. mm
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
Supplying with fitting and fixing of LED tubelight complete with all accessories such as ballast, starter, etc. directly on wall/ceiling including connection cable as approved by the deptt with 1.5 sqmm PVC insulated SC Copper conductor as required and as directed by the department.
Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV Grade Solid Aluminium conductor armoured UG Cable.UG Cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench upto depth of 75 cm,refilling,protective brick covering sand cushioning etc complete handling of surplus spoil,debris etc. to proper place as specified and directed by the deptt. 16.00 sqmm 4 core armoured UG cable
Supplying, installation, testing and commissioning of the following LED luminaries cornplete with all accessories such as ballast, starter etc in the ceiling including supplying ball and socket arrangement suspension down rod of 20 mm dia steel conduit of required length including making necessary connection cable, as approved by the Deptt. with 1.5 sq mm PVC nsulated single core copper conductor as regd. and as directed by the Deptt.DESTG250LP/S12WLED857SWH565, 240 V Havells make Surface mounted mirror optics luminaries including lamps._ or eguivalent
Supplying including fitting and fixing of following A.C Wall fan in the wall of following sweeps with making necessary connection as approved by the Deptt. as required complete and as directed by the Department.(CROMPTON /ORIENT/Havells/USHAor equivalent make) Swing platina with plastic blade. 400 mm sweep
Conctruction of 63 KVA pole mounted 11/0.4 KV Sub-Station com plete with 11 KV HT line including 12.00m and 9.00m GI steel Tubular Pole. 11/0.4 KV 63 KVA Transformer, Supension clamp, GI Channel Pole Clamp, 11 KV Pin/Disc Insulator. 11kV GOAB Switch. Lighting Arrestor. DTR Fencing as per RCC Standard and Labour Charge etc. (Rates as per APDCL SOR for the year 2021-22)
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.200 A,36KA,FPMCCB
100 A,30KA,FPMCCB
Erection of RCC/ PCC pole J following length in brick ballast and ramming the foundation, finishing with 150mm thick cement concrete (1:3:6layer on top with including excavation and reflling etc as required. Above 8.00 metre and upto 11.00 metre
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
Supplying of 3.5 Core x 95 sq.mm armoured LT Cable
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade 1 following size direct C ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 35 sq.mm and upto 95 sq.mm
Rate for APDCL Load Security as per APDCL Present Rate
Supplying including installation.commissioning of vermin and dust proot totally enclosed.phosphatised powder painted cubical outdoor type floor mounting coompartmentalize panal board of' size 1200Wx1250Hx400B mm made of 16 SWG 1.66m thick CR sheet and 35mms35mmx5mm size angle having 4 nes, of'leg at the bottom and C'R sheet rooling on the top. the panel bourd is to be erected in 1:3:6 PCC toundation including eseavation of one no. 2504 4 pole MCCB or switch fuse as incomer and provision of'2 nos DP or IPN outgoing as specitied by the deptt
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.67 MB
SBD_MATMORA.pdf
Tender Documents • 3.00 MB
BOQ_77458.xls
BOQ • 0.33 MB
FOB.pdf
Additional Documents • 0.24 MB
Download all tender documents and submit your bid