Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1 CrAccepted-AOC | ₹1 Cr | L1 | Accepted-AOC Awarded |
| 2 | L2₹1.0 Cr+₹1 L (1.00%)Rejected-AOC | ₹1.0 Cr+₹1 L (1.00%) | L2 | Rejected-AOC Not Awarded |
| 3 | Rejected-Technical 4TH FLOOR MONAL TOWER NEAR SBI DISPUR DISPUR GUWAHATI 781006 ASSAM | KAMRUP METRO | ASSAM | 781006 | - | - | Rejected-Technical Technically disqualified |
| 4 | Rejected-Technical H 01 SENAPATI BOULEVARDS SREENAGAR R G B ROAD GUWAHATI 781005 | KAMRUP METRO | ASSAM | 781005 | - | - | Rejected-Technical Technically disqualified |
Tender Value
₹1 Cr
EMD Value
₹2 L
Closing Date
15 Dec 2022, 2:00 pmClosed
CEO,Kamrup Metro Zilla Parishad,Ghy-3
Chief Executive Officer Kamrup Metro Zilla Parishad, Chandmari, Guwahati- 3
Construction of Primary Processing Slaughter House for Pig at Chandrapur, in Kamrup District.
2022_PNRD_27879_1
KMZP(D)82/TRC/2020-21/194
Open Tender
Civil Works
Item Rate
120 days
Chandrapur, Guwahati
Please refer Tender documents.
4 documents required · 4 mandatory
₹2,000
₹2 L
Yes
OFFICE OF THE KAMRUP METRO ZILLA PARISHAD
17 Jan 2023
25 Nov 2022
16 Dec 2022
25 Nov 2022
15 Dec 2022
1 Dec 2022
28 Nov 2022
Amount
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual mean foundation or drains (not exceeding 1.5m in width or 10 Sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m. All kinds of soil
Providing and laying in position cement concrete of specified grade excluding cost of centering and shuttering all works upto plinth level. 1:2:4 (1 cement : 2 coarse sand (Zone - III) derived from natural source : 4 graded stone aggregate 20mm nominal size derived from natural source)
5.2.2 Reinforced cement concrete in walls (any thickness) including attached plasters, buttresses, plinth and string courses, filters, columns, pillars, piers, abutments, posts and struts etc. above plinth upto floor level excluding the cost of centering, shuttering, finishing and reinforcement. 1:1.5:3 (1 cement : 1.5 coarse sand (Zone-III) derive : 3 graded stone aggregate 20mm nominal size derived from natural sources)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 6.1.1 Cement mortar 1:4 (1 cement : 4 coarse sand)
Brick work with common burnt clay machine moulded perforated bricks of class designation 12.5 conforming to IS: 2222 in superstructure above plinth level up to floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) : 6.3.1 With F.P.S.(non modular) bricks
Brick on edge flooring with bricks of class designation 7.5 on a bed of 12 mm cement mortar, including filling the joints with same mortar, with common burnt clay non modular bricks: 1:6 (1cement : 6 coarse sand)
Providing and laying damp proof course 40mm thick with cement concrete 1:2:4 (1cement : 2 coarse sand (Zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources)
5.9 Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns etc. for mass concrete
5.9 Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers
5.9 Centering and shuttering including strutting, propping etc. and removal of form for : Columns, pillars, piers, abutments, posts and struts
5.9 Centering and shuttering including strutting, propping etc. and removal of form for : Weather shade, Chajjas, corbets etc., including edges
5.9 Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform with water proof ply 12mm thick
5.22 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more
15 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall.
62mm thick cement concrete flooring with concrete hardener topping, under layer 50mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 Kg. of cement or as per manufacture's sprcifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete.
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. 9.48.1 Fixed to steel windows by welding
Cement plaster skirting upto 30cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 18mm thick
Stractural Steel works riveted, bolted or welded in build
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.63 mm thick with zinc coating not less than 275 gm/ m²
Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete. 0.63 mm thick with zinc coating not less than 275 gm/m²
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 10.6.1 80x1.25 mm M.S. laths with 1.25 mm thick top cover
Providing 10 mm thick plaster of Paris (gypsum anhydrous) ceiling up to a height of 5 m above floor level, over first class kail wood strips 25x6 mm with 10 mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame (frame work to be paid separately): 12.31.1 Flat surfaces
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer
13.42 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/ litre, of approved manufacturer, of required shade and colour complete, as per manufacture's specification. Two or more coats on new work
Finishing with Deluxe Multi surface paint t system for interior and exterior usuing primer as per manufracture specification
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Wiring for light/Fan/call bell point with 1.5 sq. mm. FRLS PVC insulated copper conductor single core cable in surface/recessed steel conduit, with piano type switch phenolic laminated sheet, suitable size M/s box and earthing the point with 1.5 sq. mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group B
Wiring for light/Fan/call bell point with 1.5 sq. mm. FRLS PVC insulated copper conductor single core cable in surface/recessed steel conduit, with piano type switch phenolic laminated sheet, suitable size M/s box and earthing the point with 1.5 sq. mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Wiring for light/power plug with 4x4 sq. mm. FRLS PVC insulated copper conductor single core cable in surface recessed steel conduit alongwith 2 nos. 4 sq. mm. FRLS PVC insulated copper conductor single core cable for loop earthing
Wiring for circuit wiring alongwith earth wire with the following size of LRLS PVC insulated copper conductor single core cable in surface/ Recessed steel conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 A socket outlet
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 A, 16 KA,TPMCCB
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
Erection of RCC/ PCC pole of following length in brick ballast and ramming the foundation, finishing with 150mm thick cement concrete (1:3:6) layer on top with including excavation and refilling etc as required. Above 11.00 metre and upto 13.00 metre
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Up to 120 Sqm
Erection of G.I. Wire No. 8 SWG including binding etc. as required
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) pole top bracket/ cross arm for single 33 KV over head line conductor complete with 50 mm X 6mm flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts, washers etc and painting with primer and finish paint as required.
AMS ASEB 3 Ph Connection (RS. 60,000.00)
Stunning Case with doors
Stunning Device
Lifting Arm with Chain block
Bleeding Tank
Down Arm and chain Block
Self Support Bleeding Conveyor with 5No Hook
Scalding Tank with Heater and steam injector
De Hairing Machine with Gambler table
Burning Equipments
Eviscration Trolly
Eviscration table and Hooks
Weighing Scale electronic
SS304 Self support Bleeding Conveyor with 6Nos Gambler
SS 304 Hanging Carry trolley
SS 304 Cutting Table with Nylone Pad
Cleaning Hos pipe nozzle & valve
Electric Pannel Board
Geyser
Installation & Commissioning
External Electrification including installatiuon of 321 KVA Transformer etc(Rs, 9,00,000.00)
Supplying, Erection, testing and commissioning of Effluent Treatment Plant of average capacity 5Cum on turnkey basis includiong civil works ( RS. 15,00,000.00)
M/ S R S Associates
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .