| 1 | L1₹24.5 LAccepted-AOC | ₹24.5 L Quoted ₹25.3 L | L1 | Accepted-AOC Lowest bid value |
| 2 | L2₹26.2 L+₹85,000 (3.36%)Rejected-Finance VILL KADUA PO HARIATARA DISTT PASCHIM MEDINIPUR WB PIN 721304 | HARIATARA | PASCHIM MEDINIPUR | WEST BENGAL | 721304 | ₹26.2 L+₹85,000 (3.36%) | L2 | Rejected-Finance Higher bid value |
Tender Value
₹29 L
EMD Value
₹58,000
Closing Date
4 Jan 2020, 6:00 pmClosed
CWE AF KALAIKUNDA
CWE AF KALAIKUNDA, KALAIKUNDA AIR FIELD POST, DIST WEST MEDINIPORE,721303
REPAIR/MAINT OF HT POWER DISTRIBUTION TRANSFORMER, REMOTE CONTROL PANEL, DEHYDERATION OF TRANSFORMER OIL, REPAIR TO VCB, HT CABLE AND OTHER ALLIED WORKS
2019_MES_301341_1
8341/KKD/04/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AT AF STN KALAIKUNDA AND DDK RANGE
Class D, Category b(ii)
2 documents required · 2 mandatory
₹500
Yes
GE AF KALAIKUNDA
₹58,000
Yes
11 Jan 2020
26 Nov 2019
9 Jan 2020
27 Nov 2019
4 Jan 2020
11 Dec 2019
27 Nov 2019 - 4 Dec 2019
Amount
Supply , replacement and topping up transformer oil EHV grade as per IS 335 of 1993 Part II having die electric strength of not less than 40 KV in the transformer of capacity 1 MVA at complete all as specified and directed by Eng-in-charge.
M&L for taking shut down, disconnecting incoming, out going cables, control cables from 11 KV & 36KV VCB of capacity 630A & 250A respectively Amps out door type ,servicing/overhauling , replacement of unserviceable parts, greasing of revolving assembly in VCB chamber, caliberation of relays including decorbonising the VCB panel and serviceability check from remote operation complete all as specified and directed by Engr in charge. Note: - (i) : Spare parts/components required for replacement of above shall be measured and paid separately. (ii) Unit rate quoted against this item shall also include labour required for fixing of replaced items. (iii) For item No. 3 to 16 fixing charge of items are considered under this item.
Supply only 11 KGV Post insulator epoxy cast EM-10 complete all as specified and directed by Eng-in-charge.
Supply only separartor cradle 3M complete all as specified and directed by Eng-in-charge.
Supply only Shutter-A 3M complete all as specified and directed by Eng-in-charge.
Supply only Shutter-B 3M complete all as specified and directed by Eng-in-charge.
Supply only Auxiliary switch 8-Way complete all as specified and directed by Eng-in-charge.
Supply only Plug in (block) contact assembly complete all as specified and directed by Eng-in-charge.
Supply only VTC coil comp w brkt 30V DC complete all as specified and directed by Eng-in-charge.
Supply only SW breaker control RBC/401 P 129/RI complete all as specified and directed by Eng-in-charge.
Supply only Isolating contact assembly 1250A 12kV complete all as specified and directed by Eng-in-charge.
Supply only Indicating lamp LED 22.5mm universal type E 24V-240V AC/DC of colour Red/green/amber/White/blue complete all as specified and directed by Eng-in-charge.
Supply only Mechanism operating Assembly for 36kV with bearing & spring B/O complete all as specified and directed by Eng-in-charge.
Supply only Shunt trip coil assembly 30V DC complete all as specified and directed by Eng-in-charge.
Supply only Voltmeter 0-15 kV SF96MM PTR 11kV/110V complete all as specified and directed by Eng-in-charge.
Supply only Charging Motor for 36KV PCVCB of 100Watt ,230V AC/DC complete all as specified and directed by Eng-in-charge.
M&L for servicing/overhauling , Calibration and decorbonising of 11 KV PIX panel with breaker + Relay ) and setting of Relay parameters VCB of capacity 800 Amps, indoor/out door type , taking shut down from 33 KV MRS and disconnecting incoming & out going cables , control cables from VCB and replacement of un-serviceable spares, greasing of revolving assembly in VCB chamber, spring charging mechanism including decorbonising the VCB panel and serviceability check from remote operation all as specified and directed by Engr -in - charge. Note: - (i) : Spare parts/components required for replacement of above shall be measured and paid separately. (ii) Unit rate quoted against this item shall also include labour required for fixing of replaced items. (iii) For item No. 18 to 43 fixing charge of items are considered under this item.
Supply only micom P 127 Relay complete al as specified and as diretced. Make :- Scneider
Supply only Isolating contact 800A Cat No - MVIG0013-01 set of 12 Complete all as specified and as directed. Make - Schneider
Supply only Vacuum Interrupter VG2 Cat No - MST10SG200300NA Complete all as specified and as directed. Make - Schneider
Supply only Closing coil 110VDC-CN1179 Complete all as specified and as directed. Make - Schneider
Supply only Triping Coil 110DC -OG838 Cat No -EC027SOG83800 Complete all as specified and as directed. Make - Schneider
Supply only Breaker auxillary swtich 6 No +6NC Cat No -MVIG00242-01 Complete all as specified and as directed. Make - Schneider
Supply only Motor cut off switch Cat No - MVIE00016-01 Complete all as specified and as directed. Make - Schneider
Supply only Main Drive Shaft Assembly Cat No - MVIE00062-01 Complete all as specified and as directed. Make - Schneider
Supply only Trip Fork Linkage assembly Cat No -MVIE00072-01 Complete all as specified and as directed. Make - Schneider
Supply only Handle block complete assembly MVIEoo79-01 Complete all as specified and as directed. Make - Schneider
Supply only Closing coil box assembly -MVIE00082-01 Complete all as specified and as directed. Make - Schneider
Supply only Trip coil box Assembly MVIE00231-01 Complete all as specified and as directed. Make - Schneider
Supply only Motor cut off lever assy Cat No - MVIE00173-01 Complete all as specified and as directed. Make - Schneider
Supply only Trip prop support Assembly Cat no- MVIE00023-01 Complete all as specified and as directed. Make - Schneider
Supply only Release Lever MVIE00123-02 Complete all as specified and as directed. Make - Schneider
Supply only Pin for release lever MVIE00136-01 Complete all as specified and as directed. Make - Schneider
Supply only Auxillary switch Drive Assembly MVIE00034-01 Complete all as specified and as directed. Make - Schneider
Supply only Charging paw MVIE00106-01 Complete all as specified and as directed. Make - Schneider
Supply only Buffer for spring MVIE00060-01 Complete all as specified and as directed. Make - Schneider
Supply only Over ride stop MVIE00013 Complete all as specified and as directed. Make - Schneider
Supply only Over ride stop pin MVIE00232-01 Complete all as specified and as directed. Make - Schneider
Supply only limit switch 4 terminal 10 Amps complete all as specified and directed by Eng-in-charge.
Supply only Fix R Phase Bus Bar Spout MVIF00072-02 Complete all as specified and as directed. Make - Schneider
Supply only Y Phase Bus Bar Spout MVIF00070-02 Complete all as specified and as directed. Make - Schneider
Supply only Fix B Phase Bus Bar Spout MVIF00066-02 Complete all as specified and as directed. Make - Schneider
Supply only Fix Circuit Spout MVIF00073-02 Complete all as specified and as directed. Make - Schneider
Supply and spray Moisture absorbing spray WD-40 on electric terminals of VCB Breaker and panel and allied equipment all as specified and directed.
Repair of transformer of capacity 1 MVA ,33kV/11kV outdoor type step down transformer following works :- (a) Draining out of existing traformer oil (b) Lifting of core and and winding assembly complete from in side the transformer after un screwing all nuts bolts washers and cleaning old / used insulating oil (c) Dismantling damaged laminated sheet replace dameged with new,wraping insulating paper over primary and secondary coil (d) Necessary rewinding of primary coil and secondery coil with existing/new copper wire and reinsulate with 3 layer paper insulation with machine wrapping over the winding strips suitable for HV & LV coils complete (e) Repair / replacement of all other minior parts if found un servicable worn out during repair entire satisfication of Engr in charge in Note :The replaced items shall be measured and paid seperately as supply only in schedule (ii) Unit rate quated againist this item shall also include labour charge required for fixing or replace items
Supply only Insulating paper for wrapping over primary and secondary coil complete all as directed by Engineer-in-Charge.
Supply only new Copper winding strips/wire for transformer complete all as directed by Engineer-in-Charge.
M & L for Changing all gaskets ,heating and Reassebling the the Transformer after re-winding/tightening of transformer core, tightening/replaceing of bushing/studs, oil seal etc. both primary and secoundary, fixing top cover conservator tank, breather,top cover gasket etc complete, transformer transporting to its location installing testing and commissioning up to the entire satisfication of Engr in charge in
M&L for disconnecting control cables from 110V/15A float cum boost battery charger in door type ,servicing/overhauling , replacement of unserviceable parts,complete all as specified and directed by Engr in charge. Note: - (i) : Spare parts/components required for replacement of above luminaries shall be measured and paid separately. (ii) Unit rate quoted against this item shall also be deemed to include for labour required for fixing of spares/power component parts. (iii) For item No. 50 to 53 fixing charge of items are considered in item no.49.
Supply only control card (AVR card) for single phase charger
Supply only control transformer
Supply only SCR
Supply only control PCB board
M& L for Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50sqmm-95 sqmm all as specified and directed incl taking down unsv one.
M& L for Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm all as specified and directed incl taking down unsv one.
M&L for detecting of fault in 11KV (E) HT cable of any size(within 1-3 km legth) , 3 core laid in trenches/ducts with the help of electronic fault locating machine comprising of surge generator pulse, echo fault locator with high frequency distance calculator etc and exposing the cable fault, removal of deteriorated portion of cable, treating the cable including making it ready for jointing work complete all as directed by Engineer-in-Charge. Note: - (i) The quoted rate shall deemed to include for the cost of earthwork excavation as required. (ii) Cable if replaced & Jointing kit shall be measured & paid separately.
S & F gang operated air brake switch mechanically operated on insulator and steel frame, with operating mechanism worked from ground level, with 9 nos insulator tilting type for current rating 200 Amps,11000Volt including taking down old unserviceable one complete all as specified.
S&F Expulsion type drop out fuse with all accessories fixed on HT pole rating 200Amps Amps suitable for 11kV, 3 pole with two Nos insulator per pole including dismantling old unserviceable one complete all as specified and directed.
Supply and fix lightning arrester, expulsion type complete with all fitting transmission class ,discharge capacity 65 Kilo Amp 11000 Volts rating including dismantling old unserviceable lightning arrester complete all as specified and directed by Engr-in-Charge.
Supply and fix lightning arrester, expulsion type complete with all fitting transmission class ,discharge capacity 65 Kilo Amp 33000 Volts rating including dismantling old unserviceable lightning arrester complete all as specified and directed by Engr-in-Charge.
Supply, Install, testing and commissioning of 33 KV single phase outdoor type oil cooled ,dead tank type CT of ratio 160-80/5-5-1 Amp accuracy class 0.5 for metering equipment of burden 15 VA as per IS:2705 including connection CT terminal to control panel through conntrol cable and taking down unsv one complete all as specified and directed . Note: Control cable if required will be paid under relevant item
Supply, install, testing and commissioning 33 KV single phase outdoor type oil cooled,dead tank type PT of ratio 33 KV /√3 : /110V/√3-110V/√3 ,accuracy class 0.5, Burden 150 VA conforming to IS:3156 including connection PT terminal to control panel through conntrol cable and taking down unsv one complete all as specified and directed. Note: Control cable if required will be paid under relevant item
M & L for fixing flexible control cable PVC insulated 4 core of size 2.5sqmm FR PVC sheathed multistraded cable with bright annealed electrolytic bare copper conductor for voltage grade upto 1100 Volt for connecting control panel to VCB including taking down unsv one complete all as specified and directed by Eng-in-charge.
M & L for fixing flexible control cable PVC insulated 8 core of size 2.5sqmm FR PVC sheathed multistraded cable with bright annealed electrolytic bare copper conductor for voltage grade upto 1100 Volt for connecting control panel to VCB including taking down unsv one complete all as specified and directed by Eng-in-charge.
M & L for fixing flexible control cable PVC insulated 19 core of size 2.5sqmm FR PVC sheathed multistraded cable with bright annealed electrolytic bare copper conductor for voltage grade upto 1100 Volt for connecting control panel to VCB including taking down unsv one complete all as specified and directed by Eng-in-charge.
Neha Enterprise
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .