Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.4 LAccepted-AOC 602 TECHNOLOGY APARTMENTS 24 1 P EXTENSION DELHI 110092 | DELHI | DELHI | DELHI | 110092 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹28.3 L+₹2.4 L (9.10%)Rejected-Finance | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹29.2 L+₹3.3 L (12.6%)Rejected-Finance 202 NEW RAM VIHAR COLONY PINTO PARK MORAR GWALIOR 474005 | GWALIOR | GWALIOR | MP | 474005 | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹29.3 L+₹3.4 L (13.0%)Rejected-Finance 61 ABHAY GARH SCHEME AIR FORCE JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L4 | Rejected-Finance Not lowest bidder |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
22 Jun 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Jaisalmer
GE (AF) Jaisalmer
Repair/Maint of LT Distribution system and other allied works at AF Station Jaisalmer
2022_MES_526275_1
8823/GE/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (AF) Jaisalmer
As per tender documents
7 documents required · 7 mandatory
₹500
Yes
GE (AF) Jaisalmer
₹60,000
Yes
4 Jul 2022
25 May 2022
24 Jun 2022
25 May 2022
22 Jun 2022
8 Jun 2022
26 May 2022 - 1 Jun 2022
60 days
Amount
Aluminium conductor, steel reinforced (ACSR) of any size, any type, as per existing one and stringing properly on the insulators and binding with aluminium wire 14 SWG, connectors, Jumpers etc including taking down old unserviceable conductor complete all as specified and directed. (Note : Measurements and payments shall be made by measuring horizontal distance between centres of two adjacent pole and adding 3% for sag, jointing, jumpers etc).
Re-stretching only existing Aluminium conductor, steel reinforced (ACSR) of any size on HT/ LT Pole including binding the Aluminium conductor, steel reinforced (ACSR) with insulators, aluminium binding wire complete all as specified and as directed. Note : (i) The above work includes cleaning pruning of tree branches falling around the conductors (ii) One length shall be measured for complete span of any number conductors and GI wire.
Cross arms, bracings, supports, clamps and back plates fabricated from mild steel structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one coat primer, one under coat and one finishing coat of synthetic enamel paint including disconnecting & taking down old unserviceable complete all as specified and directed.
Pin type insulator porcelain vitreous, white, brown or green for working pressure 1100 volts, 100mm height and 65mm dia including galvanized mild steel spindle, two Nos GI washers, one No GI nut including taking down crecked/unserviceable insulator complete all as specified and directed.
Shackle type insulator porcelain vitreous, white, brown or green, working pressure 1100 Volts, 90mm dia and 75mm height including galvanized mild steel straps of section 31mm x 3mm with 12mm dia insulator bolts, washers and nuts including taking down crecked/unserviceable insulator complete all as specified and directed.
Stay assembly complete with accessories as shown on electrical plate No 1 of SSR Part-I with 20mm dia 1900mm long stay rod, stay wire 7/4mm stranded galvanised including mild steel stay plate 300mm x 300mm x 6mm thick and galvanised thimble, galvanised steel 14mm dia 400mm long, stay bow and GI nuts, washers including loop type insulator vitreous porcelain white, brown or green big size with overall dimensions 90mm x 140mm clearance of hole 25.5mm, including necessary excavation, return filling, removal of surplus soil, loop insulator, clamp, stay wire and PCC 1:2:4, including taking out old unserviceable stay assembly complete all as specified and directed.
Earthing complete with galvanished earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of plate not less than 1.5 deep below normal ground level and connected to galvanished iron earth lead strip 32mmx6mm upto 7.50 metre, by means of GI nuts, bolt, check nuts, washers, thimbles, etc as shown in electrical plate No. 5 SSR Part-I and connection to main switch board or panel and testing on completion including excavation and earth work in any type to soil, returning fitting in and removal of surface spoil to a distance not exceeding 50 metre, PCC chamber (1:2:4) type B-1, charcoal and salt mixed layer 15cm thick all around the earth plate electrode, MS funnel with wire mesh, 20mm bore, Galvanised Iron pipe light grade, 1.50 metre long for watering and 40mm bore Galvanised Iron pipe light grade for earth lead protection 5.00 metre long fixed with poles with two clamps, made from earth lead strip 32mm x 6mm, bolts, nuts and washers, 80mm thick pre cast RCC cover 1:2:4, type B-1, reinforced with hard drawn steel wire fabric wieghing not less than 4 Kg/Sqm in lieu of CI cover etc including dismantling & taking out old unserviceable earthing complete all as specified & as directed. Note : (i) Excavation and earth work for drilling hole for electrode in any type of soil shall be included in this item. (ii) The unit rate shall be deemed to included for Test Point, 32mmx6mm GI strip from top of the earth plate upto 7.50m above ground level. In case, GI protection pipe required is less than 7.50m, no price adjustment shall be made. (iii) PCC Pit shall be provided at least 500mm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fittings, junctions, elbow etc shall be deemed to be included in the unit rate quoted by the tenderer.
Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No. 3 of SSR Part-I and connection to main switch board/Test point/ panel/ equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exceeding 50 metre, charcoal and salt in alternate layer 15cm thick all around the earth plate electrode, Mild Steel Funnel with wire mesh, 20mm bore, GI pipe medium grade, 1.50 metre long for watering and 15mm bore, GI pipe light grade, 7.50 metre long for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:2:4) type B-1, using 20mm graded stone aggregate with angle iron 40x40x5mm frame 60mm thick RCC cover with 6mm steel bars 100mm centre to centre both ways etc including dismantling & taking out old existing unserviceable earthing complete all as specified & as directed. Note : (i) PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) If earth resistance of earthing is not found satisfactory it will be redone by the contractor on his risk and cost.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium stranded conductor 1100 Volt grade cross sectional area 70 sqmm 3.5 core laid in trenches/ducts, through pipe, under floors or roads/along poles including taking down old unserviceable cable complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium stranded conductor 1100 Volt grade cross sectional area 50 sqmm 3.5 core laid in trenches/ducts, through pipe, under floors or roads/along poles including taking down old unserviceable cable complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium stranded conductor 1100 Volt grade cross sectional area 35 sqmm 3.5 core laid in trenches/ducts, through pipe, under floors or roads/along poles including taking down old unserviceable cable complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium stranded conductor 1100 Volt grade cross sectional area 25 sqmm 4 core laid in trenches/ducts, through pipe, under floors or roads/along poles including taking down old unserviceable cable complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium stranded conductor 1100 Volt grade cross sectional area 16 sqmm 4 core laid in trenches/ducts, through pipe, under floors or roads/along poles including taking down old unserviceable cable complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable (ISI marked) with aluminium stranded conductor 1100 Volt grade cross sectional area 10 sqmm 2 core laid in trenches/ducts, through pipe, under floors or roads/along poles including taking down old unserviceable cable complete all as specified and directed.
Supply, laying, jointing and testing 1100 volts grade heavy duty cable PVC insulated aluminium solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4mm suspension wire twin core cables 10 Sqmm including taking down old unserviceable cable complete all as specified.
Cable jointing kit for 1100 Volts grade LT cable for straight through heat shrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 25 sqmm 3.5/4 core to 95 sqmm 3.5 core including dismantling & taking out old unserviceable jointing kit complete all as specified and directed
Cable jointing kit for 1100 Volts grade LT cable for straight through heat shrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 120 sqmm 3.5 core including dismantling & taking out old unserviceable jointing kit complete all as specified and directed
Galvanized steel water tubing light grade of 40mm bore with & including all fittings complete, fixed with clamp of 25x3mm flat iron to wall/pole/ceiling or laid in trenches under floor/road, including taking up or down old unserviceable steel water tubing and connections of 40mm bore, complete all as specified and directed.
Galvanized steel water tubing light grade of 50mm bore with & including all fittings complete, fixed with clamp of 25x3mm flat iron to wall/pole/ceiling or laid in trenches under floor/road, including taking up or down old unserviceable steel water tubing and connections of 50mm bore, complete all as specified and directed.
Galvanized steel water tubing light grade of 80mm bore with & including all fittings complete, fixed with clamp of 25x3mm flat iron to wall/pole/ceiling or laid in trenches under floor/road, including taking up or down old unserviceable steel water tubing and connections of 80mm bore, complete all as specified and directed.
Polypropylene random copolymer concealed (PPR) Pipes, 3 Layer, UV stabilised having thermal stability upto 93 degree centrigrade complete and fixed with the pole by providing Flat Iron clamps, nuts and bolts of size 25x25x3mm with nuts & bolts for protection of connecting wires, connection from Junction box to light fittings complete for outer dia 20mm (PN-16), including taking up or down old unserviceable pipe and connections of 20mm bore, complete all as specified and directed.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32 x 6mm GI strip including taking down old unserviceable complete all as specified and directed. Note : Nut, bolt and other items included in quoted rate by the tenderer.)
Pre Stressed concrete Pole 9.00 mtr long, 102mm x 152mm at top and 102mm x 289mm at bottom, class 10 complying with requirements of IS-1678-1978 including painting of poles with two coats of synthetic enamel paint over a coat of primer with black and white strips 30cm wide each upto 1.5mtr height from top of PCC foundation block and numbering of poles, including disconnecting & taking down old unserviceable broken RCC Pole complete all as specified and directed. Note: (i) Excavation in trenches in any types of soil, returning filling in and well ramming including watering and disposal of surplus soil to a distance not exceeding 50 mtr from the starting points. (ii) PCC (1:4:8) type D-2 using 40mm graded crushed stone aggregate as in foundation bedding complete all as specified and directed. (iii) PCC (1:3:6) type C-2 using 40mm graded crushed stone aggregate as upto ground level complete all as specified. (iv) PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregate as in coping including necessary form work complete all as specified and directed. (v) Painting of Pole upto 1.5mtr of height from coping level with alternative strip black and sky blue of width not less than 0.30 mtr and writing pole Number with yellow shade on black base using synthetic enamel paint having height of words exceeding 5cm complete all as specified and directed. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.
Trimming of trees branches clearing both side 4.0 metre all around by cutting trees branches at ground level of any numbers and any girth on any number of conductor/earth wire of LT/HT over head line during the treeming first taken proper shutdown by informing the concerned JE (E/M) and Engr-in-Charge. Note : (i) Pole to Pole distance shall be measured & paid as one unit.
PVC insulated and fire retardant PVC sheathed, copper conductor of round cable size 1.5 sqmm, 3 core conforming to IS-694-1990 for electric connection from feeder /looping box /street light over head line to street light fittings including taking out old unserviceable cable from pole all as specified and directed.
Boring Hole/Driling (Horizontally) under the road / pavement / hard standing with the help of trenchless and necessary machine for inserting Galvanised steel pipe of size 100/80mm not less than one metre below ground level complete all as specified and directed. Note : GI pipe shall be measured and paid for seperately in respective items.
Preparation of RCC surfaces LT/HT electric poles and apply one coat of synthetic enamel paint upto 1.50 mtr length and making of pole number and five strips each 30cm wide in navy blue & white colour using synthetic enamel paind upto 1.50mtr height from top of RCC foundation block complete all as specified and directed.
Preparation of steel surfaces for steel tubular electric poles, swan neck pole of HT/LT over head line and all mild steel clamps, cross arms work on poles with apply one coat of superior aluminium paint upto 1.50 mtr length and making of pole number and five alternate strips each 30cm wide with black and navy blue colour for LT Poles and black and red colour for HT Poles using painted upto 1.50mtr height from top of PCC foundation block complete all as specified and directed.
Disconnecting, dismantling of existing old unserviceable LT Panel/Feeder pillar box and Design, supply, erection, commissioning and testing of outdoor type LT Panel, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos stepped type main copper bus bars of 400 Amps, looping & branch connection system shall be made with suitable rating copper bus bar having sleeves of colour coded .The chamber shall be painted with powder coated paint (Shade : RAL-7032) after 9 tank pre-treatment of surfaces. The LT Panel shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The LT Panel shall be made out of 3.15mm thick CRCA mild steel sheet and 3.00mm thick gland plate , front door (02 layers) and rear Door (01 layer) opening facility and 4 side slanting canopy type roof on top and mild steel channel (75 MC) base frame at bottom. All incoming MCCBs shall be marked with location and rating of MCCBs. The Feeder Pillar shall be provided with ventilation facility in the form of louvers for better heat dissipation in and including dismantling of old unserviceable LT Panel complere and including the followings : CONTROL WIRING: All control wirings shall have to be carried out with 1100 volts rated FRLS grade PVC insulated multi-flexible type copper wire of cross sectional area 1.50 sqmm and shall be properly bunched, tied and dressed, ferrule marked for proper identification and crimped with suitable size and type of tinned copper lugs and shall be wrapped with PVC spring type tube near the door hinges. CABLE ALLEY: Cable alley shall be provided in both side of the panel of suitable space for all incoming and outgoing cables. Cable terminals shall be provided for conencting of all incoming and outgoing cables.
Fpr serial item No. 29.00 (Contd...) INCOMING : (a) MCCB, 4 Pole, 250 Amps rating, rupturing capacity 35/36 kA, 415 volt grade, AC supply, 50 Hz, Electronic release protection unit - 01 Nos OUTGOING:(a) MCCB, 4 Pole, 100 Amps, rupturing capacity 25 kA, 415 volt grade, AC supply, 50 Hz, thermal Magnetic protection unit - 04 Nos (b) MCCB, 4 Pole, 63 Amps rating, rupturing capacity 16 kA, 415 volt grade, AC supply, 50 Hz, Thermal Magnetic protection unit - 02 Nos (c) MCCB, 4 Pole, 40 Amps rating, rupturing capacity 16 kA, 415 volt grade, AC supply, 50 Hz, Thermal Magnetic protection unit - 02 Nos (d) Digital voltmeter 96x96mm suitable to read 0 to 500 volt accuracy class 1% - 01 Nos, (e) Digital ammeter 96x96mm suitable to read 0 to 630 volt accuracy class 1% - 01 Nos, (f) Current Tranformer (CT) of rating 630/5, tape wound, rated burden 5 VA - 03 Nos (g) LED indicator lamps complete with integral circuit and cluster LED, suitable to operate in 230-240 Volts AC supply - 1 set of 03 Nos ({RYB) (Red-01, Yellow-01, Blue-01)}.
For serial item No. 29.00 (Contd...) OUTGOING : (h) Control fuse holder, made of bakellite, 16 Amps rating, stud type, panel door mounting complete with 01 No 02 Amps HRC fuse of suitable type - 03 Nos, (j) Copper bus bar 20mm wide, 5mm thick suitable length duly mounted on FRP bus bar insulators and marked with standard colour coded sleeves / tapes for all outgoing MCCBs - 04 Nos (k) LED Pilot Lamp of following colours : (i) RED - 01 No, YELLOW - 01 No, BLUE - 01 No. (l) Danger Notice Plate - 02 Nos (m) Power contactor Four Pole with coil voltage 230 volt of capacity 25 Amps, 50 cycles - 01 Nos (n) Time switch microrex analog time switch Cat part No 412814 of Legrand -01 Nos (o) Panel box made up of CRCA mild steel 3.15mm thick, duly powder coated with bus bar and internal wiring all as per CPRI approved.
Disconnecting, dismantling of existing old unserviceable LT Panel/Feeder pillar box and Design, supply, erection, commissioning and testing of outdoor type LT Panel, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos stepped type main copper bus bars of 800 Amps, looping & branch connection system shall be made with suitable rating copper bus bar having sleeves of colour coded .The chamber shall be painted with powder coated paint (Shade : RAL-7032) after 9 tank pre-treatment of surfaces. The LT Panel shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The LT Panel shall be made out of 3.15mm thick CRCA mild steel sheet and 3.00mm thick gland plate , front door (02 layers) and rear Door (01 layer) opening facility and 4 side slanting canopy type roof on top and mild steel channel (75 MC) base frame at bottom. All incoming MCCBs shall be marked with location and rating of MCCBs. The Feeder Pillar shall be provided with ventilation facility in the form of louvers for better heat dissipation in and including dismantling of old unserviceable LT Panel complere and including the followings : CONTROL WIRING: All control wirings shall have to be carried out with 1100 volts rated FRLS grade PVC insulated multi-flexible type copper wire of cross sectional area 1.50 sqmm and shall be properly bunched, tied and dressed, ferrule marked for proper identification and crimped with suitable size and type of tinned copper lugs and shall be wrapped with PVC spring type tube near the door hinges. CABLE ALLEY: Cable alley shall be provided in both side of the panel of suitable space for all incoming and outgoing cables. Cable terminals shall be provided for conencting of all incoming and outgoing cables.
For serial item No. 30.00 (Contd...) INCOMING (a) MCCB, 4 Pole, 630 Amps rating, rupturing capacity 50 kA, 415 volt grade, AC supply, 50 Hz, Electronic release protection unit - 01 Nos OUTGOING (a) MCCB, 4 Pole, 250 Amps, rupturing capacity 36 kA, 415 volt grade, AC supply, 50 Hz, thermal Magnetic protection unit - 02 Nos (b) MCCB, 4 Pole, 200 Amps rating, rupturing capacity 25 kA, 415 volt grade, AC supply, 50 Hz, Thermal Magnetic protection unit - 02 Nos (c) MCCB, 4 Pole, 160 Amps rating, rupturing capacity 25 kA, 415 volt grade, AC supply, 50 Hz, Thermal Magnetic protection unit - 01 Nos (d) Digital voltmeter 96x96mm suitable to read 0 to 500 volt accuracy class 1% - 01 Nos, (e) Digital ammeter 96x96mm suitable to read 0 to 630 volt accuracy class 1% - 01 Nos, (f) Current Tranformer (CT) of rating 630/5, tape wound, rated burden 5 VA - 03 Nos (g) LED indicator lamps complete with integral circuit and cluster LED, suitable to operate in 230-240 Volts AC supply - 1 set of 03 Nos ({RYB) (Red-01, Yellow-01, Blue-01)}.
For serial item No. 30.00 (Contd...) OUTGOING (h) Control fuse holder, made of bakellite, 16 Amps rating, stud type, panel door mounting complete with 01 No 02 Amps HRC fuse of suitable type - 03 Nos, (j) Copper bus bar 20mm wide, 5mm thick suitable length duly mounted on FRP bus bar insulators and marked with standard colour coded sleeves / tapes for all outgoing MCCBs - 04 Nos (k) LED Pilot Lamp of following colours : (i) RED - 01 No, YELLOW - 01 No, BLUE - 01 No. (l) Danger Notice Plate - 02 Nos (m) Power contactor Four Pole with coil voltage 230 volt of capacity 25 Amps, 50 cycles - 01 Nos (n) Time switch microrex analog time switch Cat part No 412814 of Legrand -01 Nos (o) Panel box made up of CRCA mild steel 3.15mm thick, duly powder coated with bus bar and internal wiring all as per CPRI approved.
Dismantling of old unservicable bus bar chamber and Design, supply, erection, testing and commissioning of outdoor type LT Bus Bar Chamber box, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos stepped type Aluminium bus bars (32mm x 5mm) for looping & branch connection system .The chamber shall be painted with powder coated paint (Shade : RAL-7032) after 7 tank pre-treatment of surfaces. The bus bar chamber shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The bus bar chamber shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate , front door (01 layer) and rear Door (01 layer) opening facility and 4 side slanting canopy type roof on top and mild steel channel (75 MC) base frame at bottom. The bus bar chamber shall be provided with ventilation facility in the form of louvers for better heat dissipation. Note : The bus bar chamber Box shall be designed in such a way that adequate workable space is made available inside the compartments and the size of the chamber shall not be less than 500mm height (without base frame & canopy), 500mm width and 450mm depth).
Dismantling/taking down of old existing street light switching system and supply, fixing, connecting and testing of Automatic street light switch using infrared sensor based nature switch for automatic switching of street lights, nature switch operation should be based on natural light lux level. Required illumination level for switching on is <30 lux and for switching off >10 lux. The sensor should also have part night operation facility for 4-12 hours. The sensor alongwith suitable power contactor, incoming-outgoing MCBs should be enclosed in a pole/wall moutaed enclosure made out of rust proof, electric shock proof, termite proof and FR grade SMC junction box conforming to IP-54. The circuit should be suitable enough to take 8 KW 3 Phase load with contactor 25 Amps conforming to IEC-60947-4-1/IS-13947-4-1 and incoming and outgoing MCBs of rating 32 Amps conforming to IEC-60898/IS-8828 and circuit wiring of minimum 10 sqmm copper conductor wire and including providing of 50x6mm flat iron clamp, necessary nuts and bolts, complete all as specified and directed. Make of nature switch - Model No Swadeep-02EC8kw3P of Kakatiya Energy System or equivalent make of Bajaj/Healer, Make for Contactor- BCH/L&T/Schneider, Make of MCBs-Hager/Schneider/L&T/C&S, Enclouser - Sintax or equivalent
Cable Junction box made out of polycarbonate with IP 55/IP 65 protection of size 200mm x 160mm x 98mm, 5 way having terminals for termination of cable with necessary nuts and bolts including 02 Nos polycarbonate cable gland, 01 Nos DIN rail for mounting of MCB and including MCB, Single Pole, rupturing capacity 10 kA, 6 Amps in and including fixing clamp of FI 50 x 6mm with necessary nuts and bolts complete including taking down old unserviceable junction box of any type complete all as specified and directed.
Attending major breakdowns by providing 01 line man, one helper and one Camper Vehicle in serviceable condition on LT/HT lines, LT/HT cables, LT Panels, DBs, VCBs, RMUs, four pole, two pole, transformers etc including clearing of lines, trimming of tree branches, replacement of insulators/conducotrs/ cross arms & removal of tree branches from LT/HT lines and laying of temporary cables etc complete all as directed at site by Engr-in-charge. Note:- 1 Items used will be measured & paid seperately under relevent item of sch A. Contractor has to arrange suitable vehicle with manpower as above and T&P on short notice as & when required on the direction of Engineer in charge. The contractor will immediately depute complete set of arrangements as above on receipt of information to attend the electric breakdown, failing which the contractor should face penalty at the rate of 1% of work done amount of the CA.
MCCB, 3 Pole, 100 Amps rating, rupturing capacity 16 kA, 415 Volt grade, AC, 50 Hz, thermal Magnetic protection unit and connected link and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified & directed.
MCCB, 4 Pole, 160 Amps rating, rupturing capacity 36 kA, 415 Volt grade, AC, 50 Hz, thermal Magnetic protection unit and connected link and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified & directed.
MCCB, 4 Pole, 200 Amps rating, rupturing capacity 36 kA, 415 Volt grade, AC, 50 Hz, thermal Magnetic protection unit and connected link and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified & directed.
MCCB, 4 Pole, 250 Amps rating, rupturing capacity 36 kA, 415 Volt grade, AC, 50 Hz, thermal magnetic protection unit and connected link and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed.
MCCB, 4 Pole, 400 Amps rating, rupturing capacity 36 kA, 415 Volt grade, AC, 50 Hz, thermal magnetic protection unit and connected link and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed.
MCCB, 4 Pole, 630 Amps rating, rupturing capacity 50 kA, 415 Volt grade, AC, 50 Hz, thermal magnetic protection unit and connected link and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified and directed.
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc. or for laying of cables, pipes, erection of poles, structs/stays etc. or for shafts, wells, cesspits, manholes, pier holes, etc not exceeding 10 sqm on plan and getting out any type of soil complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil complete all as specified.
Removal of excavated soil/ material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50 metre above the starting point complete all as specified.
Stone patti 40 to 50mm thick rough dressed Jodhpur stone slab cover in trenches for protection of cable 25 to 35cm wide and not less than 80cm in length laid dry abutting each other with gap between adjacent slab not exceeding 10mm over sand cushioning complete all as specified and directed.
Dry tibba sand cushioning to underground cable provided with a layer of 8cm deep before laying cable and 15cm after laying of cable and punned to 18cm after laying of cable and cover for protection of underground cable complete all as specified and directed. Notes :- (i) Approved dry sand free from vegetation, grass and other deleterious substances shall be used. (ii) For the purpose of payment only punned thickness shall be measured for payment.
Plain cement concrete (1:4:8) Type D-2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete for foundation of walls complete all as specified and directed.
Plain cement concrete (1:2:4) Type B-1 (using 20 mm graded granite stone aggregate) as in copping of poles including necessary form work and finished the surfaces complete all as specified and directed.
Making earthing pit on existing old earthing where pit is completely damaged including cover 80mm thick pre-cast RCC (1:2:4) type B-1 cover reinforced with hard drawn steel wire fabric weighing not less than 4 Kg/sqm in lieu of CI cover, PCC 1:3:6 type C2 pit/chamber including all necessary excavation and earth work complete all as directed and directed.
Making earthing pit chamber cover on existing old earthing of 80mm thick pre-cast RCC (1:2:4) type B-1 reinforced with hard drawn steel wire fabric weighing not less than 4 Kg/sqm complete all as specified and directed.
M/S SUMAN ENTERPRISES
AUTOMATION AND SWITCHGEAR CONTROL
SANJOLI CONSTRUCTION COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .