| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹27.5 LAccepted-AOC 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹34.7 L+₹5.9 L (20.3%)Rejected-AOC D1C 47A JANAK PURI NEW DELHI 110058 | NEW DELHI | DELHI | DELHI | 110058 | L-2 | Rejected-AOC L-2 |
Tender Value
Refer Docs
EMD Value
₹94,000
Closing Date
14 Sept 2023, 6:00 pmClosed
GE I RND DELHI
MILITARY ENGINEER SERVICE, GARRISON ENGINEER (I) RND, LUCKNOW ROAD, TIMARPUR, DELHI-110054
REPAIR/ MAINT OF TRANSFORMER, VCB PANEL INCLUDING HT CABLES AND CERTAIN ALLIED MISC WORKS AT METCALFE HOUSE AREA AND JCB UNDER GE (I) RND DELHI
2023_MES_614644_1
GE/RND-70/DLI/2023-2024
Open Tender
Civil Works
Item Rate
270 days
Delhi
Class-D, Cat-b(ii)
2 documents required · 2 mandatory
₹500
GE I RND DELHI
₹94,000
Yes
21 Nov 2023
19 Aug 2023
16 Sept 2023
19 Aug 2023
14 Sept 2023
26 Aug 2023
Amount
Taking proper shutdown & Isolate the HT electric supply and taking out the trolley of VCB HT 11KV 400 to 630 amps of any make and type and servicing of all minor/major parts of the VCB by cleaning isolating contact moving parts,removing dust particle from the bus bar chamber spout gear mechanism, repair to motor charge spring mechanism,tightening of all nut & bolts of entire trolley component all as directed , inserting the trolley, testing the complete HT electric supply and putting on supply on load complete all as specified and directed. Note:- (i) All cleaning /testing equipment/material shall be provided by the contractor and rate of deemed to be included in quoted rates. (ii) The complete test report shall be submitted by the contractor to GE (I) R&D Delhi.
Calibration of IDMT/ BUCHHOLZ relay of 11KV HT VCBs /TRF and 1.1KV ACBs installed at Main Receiving sub station, DESIDOC, ISSA, CEPTEM and DCDA sub station complete all as specified and directed. Note:- 1. All testing & calibration equipment with all accessories shall be brought by the contractor and rate for same is deemed to be included in quated rates. 2. The complete test reports shall be submitted to GE (I) R&D Delhi
Supply, fixing, installation, testing and Calibration of IDMT relay of 11KV HT VCBs installed at Main Receiving sub station, DESIDOC, ISSA, CEPTEM and DCDA sub station complete all as specified and directed.
S&F in replacement fuse base suitable for cylindrical /DIN type HRC fuse of capacity 2-32 amps complete all as specified and directed. Make:- AE/GE/L&T or equivalent.
S&F in replacement of closing spring assembly complete all as specified and directed.
S&F in replacement of tripping spring assembly complete all as specified and directed.
S&F in replacement of charging motor cut off limit switch complete all as specified and directed.
S&F in replacement of spring charging handle motorized mechanism complete all as specified and directed.
S&F in replacement of push button bracket assembly complete all as specified and directed.
S&F in replacement bus bar support insulator 75 mm dia including all fixing accessories complete suitable for VCB/HT Bus bar chamber with colour coding all as specified and directed. Make:- Jaipuriya or equivalent as approved by GE.
S&F in replacement bus bar barrier (set of three) with nuts bolts complete all as specified and directed. Make:- CG/ andrew Yule /ABB.
S&F in replacement Charged/Discharged indication assembly complete all as specified and directed. Make:- CG/Andrew Yule or ABB.
S&F in replacement one pole assembly of any make/type 11 KV VCB complete all as specified and directed.
S&F in replacement 3 Pole MCCB, 100 Amp, 50 Hz, 415 V with rupturing capacity 16 KA complete all as specified and directed.
S&F in replacement 3 Pole MCCB, 250 Amp, 50 Hz, 415 V with rupturing capacity 25 KA complete all as specified and directed.
S&F in replacement 3 Pole MCCB, 400 Amp, 50 Hz, 415 V with rupturing capacity 36 KA complete all as specified and directed.
S&F in replacement 3 Pole MCCB, 630 Amp, 50 Hz, 415 V with rupturing capacity 50 KA complete all as specified and directed.
S&F in replacement 4 Pole MCCB, 160 Amp, 50 Hz, 415 V with rupturing capacity 25 KA complete all as specified and directed.
S&F in replacement 4 Pole MCCB, 250 Amp, 50 Hz, 415 V with rupturing capacity 25 KA complete all as specified and directed.
S&F in replacement 4 Pole MCCB, 400 Amp, 50 Hz, 415 V with rupturing capacity 36 KA complete all as specified and directed.
S&F in replacement 4 Pole MCCB, 630 Amp, 50 Hz, 415 V with rupturing capacity 50 KA complete all as specified and directed.
Disconnecting and taking down unserviceable current transformer of any description and in any position and supply, installation, commissioning and testing of current transformer any type/model 11 KV having ratio of 200+100\5+5 A having protection core class 5P 10, burden of 15 VA and metering core class 1.0 and burden of 15 VA breaking cap of 13.1 KV for 1.0 second all as specified and directed. Make :- Crompton/Alstom/L&T
M&L in replacement control wiring with multistranded copper conductor of size 2.5 sqmm 3 Core FRLSH matching with existing size/type including proper laying with the help of locking device complete all as specified and directed.
Taking down repairable potential transformer of HT VCB 11 KV/ 110 V of any make, opening & dismantling the complete unit and refitting after carrying out the following jobs:- (a) Rewinding of transformer as per existing gauge and pattern. (b) Cleaning and servicing of the PT (c) Replacement of wornout nuts/bolts and other minor parts including HRC Fuse. (d) Soldering / tightening of loose connections. (e) Replacement of potential transformer oil having dielectric strength upto 60 KV. (f) Painting of outer portion of PT with two coats synthetic enamel paint of grey colour. (g) Testing of the PT's for proper functioning to the entire satisfaction of GE.
Disconnecting and taking down unserviceable Potential transformer of any description and supply, installation, commissioning and testing of potential transformer for HT VCB 11 KV/110 VAC 3 Phase of Mild Steel Body Oil cooled Class 10 complete all as specified and directed. Make :- Crompton/Alstom/L&T
S&F in replacement of 11 pin anti pumping relay 110V DC complete all as specified and directed. Make:- CG/L&T/Andrew yule or equivalent as approved by GE.
S&F in replacement of bottom terminal with jaw contact complete all as specified and directed. Make:- CG/L&T/Andrew yule or equivalent as approved by GE.
S&F in replacement of Top terminal with jaw contact complete all as specified and directed. Make:- CG/L&T/Andrew yule or equivalent as approved by GE.
S&F in replacement of space heater 230V AC 80W complete with all accessories all as specified and directed. Make:- CG/L&T/Andrew yule or equivalent as approved by GE.
S&F in replacement of thermostate complete with all accessories all as specified and directed. Make:- CG/L&T/Andrew yule or equivalent as approved by GE.
S&F in replacement of PT epoxy female bushing suitable for R-Y-B phase complete all as specified and directed. Make:- CG/L&T/Andrew yule or equivalent as approved by GE.
S&F in replacement of PT epoxy male bushing suitable for R-Y-B phase complete all as specified and directed. Make:- CG/L&T/Andrew yule or equivalent as approved by GE.
S&F in replacement of PT fuse 11 KV complete all as specified and directed. Make:- CG/L&T/Andrew yule or equivalent as approved by GE.
M&L for replacement of interlocking control wiring of capacitors bank ( contactor type & Thyristor type) with suitable size not less than 2.5 sqmm multistranded FRLSH of copper wires complete including making connection and testing the system complete all as specified and directed.
Dehydration and filtration of transformer oil with proper dehydration machine to achieve dielectric strength between 45 to 60 KV including testing/recording of dielectric strength result before and after of dehydration complete all as specified and directed.
Supply and topping up transformer oil having dielectric strength not less than 45 KV complete all as specified and directed. Make: Savita/Power or equivelent as approved by GE.
Taking shut down from main substation and drain out the transformer oil to be collected in barrel by opening the transformer cover of capacity 300 to 500 KVA by unscrewing the nuts/bolts and washers and kept in safe custody and reuse the same, and checking any type of leakage from both HT and LT side including cleaning the sludge etc depositing in the core and tank by using soft brushes and clean with old transformer oil, refilling of transformer oil including refixing of top cover including nut/bolts etc and testing the input & output voltage and adjustment of the voltage through tape changer if required complete for entire satisfaction of engineer incharge complete all as specified and directed.
All as per item Ser No 37.00 above but transformer of capacity 630 KVA to 1500 KVA.
All as per item Ser No 37.00 above but Automatic Voltage Stabilizer of capacity 300 KVA.
Taking shut down from main substation and M&L for painting to Transformer 300 KVA to 1500 KVA and automatic servo voltage stabilizer 100 KVA to 300 KVA with spray gun with two coats of synthetic enamel heat resistant grey paint over a coat of red oxide primer including preparation of old painted surfaces/removing old faded/rust/ cemented material of surface of transformer including base frame, connected LT panels, duct covers of including writing MES/SM No of existing size/surface complete all as specified and directed.
S&F in repair HT bushing 11KV suitable for 300 to 1000 /1500 KVA Transformer including brass rod and complete with gasket as per matching to existing complete all as specified and directed.
S&F in repair LT bushing 1.1KV suitable for 300 KVA to 1000 /1500 KVA transformer including brass rod and complete with gasket as per matching to existing complete all as specified and directed.
M&L in replacement Cable jointing kit for 11 KV (Earthed) grade cable for indoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed. Make: M-Seal/Denson/Raycham
M&L in replacement Cable jointing kit for 11 KV (Earthed) grade cable for indoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185sqmm complete all as specified and directed. Make: Cabseal/Denson/Raycham
M&L in replacement Cable jointing kit for 11 KV (Earthed) grade cable for indoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm to 300 sqmm complete all as specified and directed. Make:M-Seal/Denson/Raycham
S&F in repair Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed. Make: M-Seal/Denson/Raycham
S&F in repair Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm. complete all as specified and directed. Make: M-Seal/Denson/Raycham
S&F in repair head gasket sheet 6mm thick suitable for Transformer 300KVA to 1500 KVA capacity as per matching to existing complete all as specified and directed.
S&F in repair head gasket sheet 6mm thick suitable for Automatic Servo Voltage stabilzer 100KVA to 300 KVA capacity as per matching to existing complete all as specified and directed.
S&F in replacement of Dehydrating breather assembly complete with silica gel grains in the breather assembly suitable for transformers 300 KVA to 1000/1500 KVA complete as per matching to existing complete all as specified and directed.
S&F in replacement of temperature gauge analog type complete with all accessories as per matching to existing complete all as specified and directed.
Supply & laying in replacement and testing XLPE Cable Insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 11000 Volts grade with stranded aluminium conductor of size 95 sq mm 3.0 core complete all as specified and directed.
Supply & laying in replacement and testing XLPE Cable Insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 11000 Volts grade with stranded aluminium conductor of size 120 sq mm 3.0 core complete all as specified and directed.
Supply & laying in replacement and testing XLPE Cable Insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 11000 Volts grade with stranded aluminium conductor of size 185 sq mm 3.0 core complete all as specified and directed.
Supply & laying in replacement and testing XLPE Cable Insulated screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 11000 Volts grade with stranded aluminium conductor of size 300 sq mm 3.0 core complete all as specified and directed.
Excavation in trenches in soft/loose soil not exceeding 1.5m depth not exceeding 1.5m in width for laying of cables/brick work etc complete all as specified and directed.
Excavation in trenches in hard/dense soil not exceeding 1.5m depth not exceeding 1.5m in width over energised LT cables for carrying out brick work/cable etc for preparation of cable duct including for taking out and relaying of LT Cables etc complete all as specified and directed.
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25cm thick as in soft/loose soil complete all as specified and directed.
Removing surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level and not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Supply & laying dry fine sand for cushioning of underground cable laid in trenches/duct complete all as specified and directed. Note:- Punned thickness shall be measured and paid sand shall be laid 8cm below & 15cm above the cable.
M&L for un-reinforced precast concrete cable cover, class HV type I, flat, size 300mm x 180 mm x 40mm over the HT cable for protection of cable complete all as specified and directed.
M&L for boring of holes under road, pavement, hard standing by trenchless techonology using ultra sound technique and necessary machine including supply and laying of HDPE pipe pf 160 mm dia type PN 4 working pressure complete all as specified and directed.
M&L for GI pipe medium grade of 100mm dia laid in trenches for protection of UG cable including taking out old unserviceable GI pipe complete all as specified and directed.
M&L for GI pipe medium grade of 150mm dia laid in trenches for protection of UG cable complete including taking out old unserviceable GI pipe complete all as specified and directed.
M&L for PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate) for repairing of foundation of transformers, VCBs and earthing pit etc including filling in road cuts/ hard standing etc complete all as specified and directed.
S&F Laying synthetic insulating mat of size 2m x lm x 25 mm complete all as specified and directed.
M&L for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size complete all as specified and directed.
S&F in replacement battery 12V 200 AH in Bhaskar building UPS room for 60 KVA UPS to be connected by OEM representative or as per OEM's discretion complete including all connected materials required at site for smooth functioning of UPS of OEM : M/s Riello Powers India Pvt Ltd complete all as specified and directed.
Material and Labour for earthing complete with iron earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not less than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with galvanised iron strip of 32x6 mm by means of Copper nuts, bolts and washers. Strip laid in 40mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following complete all as specified and shown in electrical plate No 3 of SSR Part-I & testing on completion :- (a) GI strip of size 32mm x 6mm. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) Excavation & earthwork in any type of soil PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 50mm thick 1:2:4 type B1 reinforced with 8mm dia mild steel bar 75mm centre to centre with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover.
M&L in replacement for earth continuity conductor passing through PVC Conduit of size 25 mm as main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or any other indicated situation for loop earthing etc as required 20x3mm Copper strip complete all as specified and directed.
M&L in replacement for earth continuity conductor passing through PVC Conduit of size 40 mm as main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or any other indicated situation for loop earthing etc as required 32x6 mm galvanised iron strip complete all as specified and directed.
M&L in replacement for MS chequred plate of suitable size for cable duct cover 6mm thick and earth pit cover complete all as specified and directed.
S&F three phase overcurrent earth fault relay MC-61A as per matching to existing one including all accessories and wiring complete including taking down old unserviceable relay complete all as specified and directed. Make:- AE/L&T or equivelent as approved by GE.
S&F three phase digital KV meter range up to 15 Kv as per matching to existing one including all accessories and wiring complete including taking down old unserviceable relay complete all as specified and directed. Make:- AE/L&T or equivelent as approved by GE.
S&F in repair digital ammeter for current range of (0-1000Amps) as per matching to existing including all accessories and wiring complete all as specified and directed. Make:- AE/L&T or equivelent as approved by GE.
S&F in replacement of power bank DC voltage for VCBs suitable for the VCBs including testing complete all as specified and directed. Make :- CG/Andrew Yule or equivelent as approved by GE.
S&F in replacement of Ring type Copper thimble of size 95 sqmm for terminal end of HT cable suitable for 11KV high Voltage carrying high quality material complete all as specified and directed.
S&F in replacement of Ring type Copper thimble of size 120 sqmm for terminal end of HT cable suitable for 11KV high Voltage carrying high quality material complete all as specified and directed.
S&F in replacement of Ring type Copper thimble of size 185 sqmm for terminal end of HT cable suitable for 11KV high Voltage carrying high quality material complete all as specified and directed.
S&F in replacement of Ring type Copper thimble of size 300 sqmm for terminal end of HT cable suitable for 11KV high Voltage carrying high quality material complete all as specified and directed.
S&F in replacement of Ring type Copper thimble of size 400 sqmm for terminal end of HT cable suitable for 11KV high Voltage carrying high quality material complete all as specified and directed.
Supply only Electrical insulation HT tape of 3/4"width and 30 feet length Etylene Propylene backing highly comfortable to wrap snugly over most any shape streches up 100 percent to provide avoid moisture, resistant insulation tape complete all as specified and directed.
S&F Monoplast compound Putty use for jointing material of LT/HT cable complete all as specified and directed.
Suply only CRC 2-23 Electrical equipment (contact) cleaner spray used to prevent electronic malfunction equipment caused by water penetration, humidity, corrosion etc and of 500ml can complete all as specified and directed.
S&F earth pit chamber alongwith cover of Polymer, FRP Pit Cover of heavy high grade polypropelene for high stress and starin level of size 225x300x 195 mm complete all as specified and directed.
M&L for repair, rewinding of indoor transformer of capacity upto 630 KVA capacity after disconnecting HT/LT supply cables shifting of transformer to workshop , drain out oil in barrels and clean the chamber. Taking out all brunt wiring and rewinding the same with existing gauge copper winding wire/strip both side. Replace damaged HT/LT porcelain bushes with stud nuts wasahers etc, connections with primary and secondary windings and reconnecting with main terminals as required and as directed, reassembling of all parts line breather assembly, conservator, temprature gauges and all minor parts after proper cleaning. Replace all unserviceable gaskets of top cover, HT/LT bushings and tape changers etc with new one of 4.0/6.0 mm thick rubberised sheet duly pasted with adhesive. Repositioning of core and winding assembly inside tank, reassembling complete transformer properly, replace unserviceable nuts bolts etc for proper tightening, refill transformer oil after proper dehydration and topup with new oil. Testing of transformer on load for and after reinstallation at site for entire satisfaction of Engr-in-Charge complete all as specified and directed.
S&F in replacement ACP retro reflective sign board to fix in existing pipe frame stand approx size 1.9m x 1.3m using retro reflective high intensity prismatic reflective sheeting. The back ground of board is Blue Colour with white border and writing letter, numbers white colour mentioning the HT/LT subtation Details, and Single line Schematic diagram of substation. Retro sign board shall be pasted on 3 mm thick ACP sheet. The board shall be fixed on wall/existing stand including fixing of fastners, nuts, bolts, washer etc required if any complete all as specified and directed Make: ALOMAX/INDO BOND/ALUTEC
S&F in replacement ACP retro reflective sign board of suitable to fix in existing pipe frame stand approx size 1.5m x 1.1m using retro reflective high intensity prismatic reflective sheeting. The back ground of board is Blue Colour with white border and writing letter, numbers white colour mentioning the HT/LT subtation Details, and Single line Schematic diagram of substation. Retro sign board shall be pasted on 3 mm thick ACP sheet. The board shall be fixed on wall/existing stand including fixing of fastners, nuts, bolts, washer etc required if any complete all as specified and directed. Make: ALOMAX/INDO BOND/ALUTEC
Pradeep Bros
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .