| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.0 LAccepted-AOC | L1 | Accepted-AOC Lowest reasonable Bidder | |
| 2 | L2₹14.0 L+₹59,240 (4.42%)Rejected-Finance 852 EKTA VIHAR 1 C NEAR ANAND NAGAR 9 B PATIALA 147001 | PATIALA | PATIALA | PUNJAB | 147001 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹14.1 L+₹67,860 (5.06%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹14.6 L+₹1.2 L (8.66%)Rejected-Finance 32 FATEH ENCLAVE OFFICERS ENCLAVE PHASE II PATIALA 147001 PB | PATIALA | PATIALA | PUNJAB | 147001 | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹14.9 L+₹1.5 L (11.3%)Rejected-Finance C 33 3971 GALI NO 6 JALANDHAR CANTT 144005 | JALANDHAR | JALANDHAR | PUNJAB | 144005 | L5 | Rejected-Finance Not Lowest |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
9 Sept 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE North Patiala
GE North Patiala Sangrur Road Patiala Mil Stn
CLEANING AND MAINTENANCE OF SEWAGE NETWORK IN ZONE A AND OTHER MISC LOCATIONS UNDER AGE BR II GE NORTH PATIALA
2020_MES_364833_2
GE(N)/PAT-23/2020-21
Open Tender
Civil Works
Item Rate
335 days
Patiala Mil Stn
As per cover 1
6 documents required · 6 mandatory
₹500
Yes
GE North Patiala
₹30,000
Yes
15 Sept 2020
22 Aug 2020
11 Sept 2020
22 Aug 2020
9 Sept 2020
28 Aug 2020
22 Aug 2020 - 27 Aug 2020
60 days
Amount
Upkeeping under ground sewage network including manholes obstruction free by removing any type of blockage in any kind of manhole or lines including removing blockage inside the building from EWC/WC/floor trap/gully trap etc in Zone 'A' old cantt area by deploying adequate manpower and suitable T&P so as to avoid damage to the line/structure complete all as specified and as directed. Note:- (i) Sewage network under new cantt area consists appx 15.0 Km long (Dia of pipe up to 200mm-11.00 Km & Dia of pipe exc 200mm but n. exc 600mm-4.00 Km) (ii) Contractor will arrange suitable T & P such as vibrations/drilling concept ie trolly mounted machanised sewer cleaning machine as required for upkeeping the system blockage free including desludging, descaling, flushing the entire stretch. (iii) Contractor or his rep will report daily on 9 AM at complaint cell of old cantt for collection of complaints from the concerned JE's Incharge and muster roll of the staff will be maintained at complaint cell in the custody of JE concerned. On failure of collecting daily complaints, a penalty of Rs. 1000/- per day in addition to delay in attending the complaints will be charged. A seperate muster roll register will be maintained in AGE office. (iv) Immediately after lodging daily complaints by the users or directed by the EIC consequent to his routine check, the concerned JE shall intimate/hand over the complaint to the contractor or his rep for attending complaints to the satisfaction of user / Engineer-in-charge within 24 Hrs. In case of failure to attend the complaint within specified period, a penalty of Rs.500/- per day per complaint shall be imposed on the contractor for the period the work remains incomplete. After 03 days from the date of handing over of complaint, the unattended complaints shall be got completed from any other agency at the risk and cost of the contractor without any notice to the contractor. In case of disputes as to delay happened in attending the complaint or inadequate period, decision of Accepting Officer shall be final, conclusive and binding. (v) During cleaning of deep manholes or pipe lines, for precautions, contractor will also arrange oxyzen cylinder of suitable size, rope/chain to the workmen and cost thereof shall be included under this item.
Excavation in trenches in soft/loose soil not exceeding 1.50 Mtr wide and not exceeding 1.50 Mtr in depth and getting out in soft/loose soil complete all as specified and directed Engineer-in-Charge
All as per Serial items No. 2.00 herein before but exceeding 1.5 Mtr and not exceeding 3.00 Mtr depth
Dismantling of brick work built in cement mortar including all quoins, pillars, arches etc complete all as specified
Brick work using Sub Class "B" bricks, disignation 100, straight or curved on plan not exceeding 6 Mtr means radius built in CM 1:4 complete all specified and directed by Engineer-in-Charge
All as per Serial items No. 5.00 here-in-before but using old serviceable bricks obtained under item No.04 here-in-before.
Taking down cement plaster on brick walls built in cement mortar including raking out joints and concrete surfaces as in wall or ceiling etc. including hacking for key, scrubbing down with water etc complete all as specified and directed.
Cement plaster 15mm thick on fair faces of brick work in cement mortar 1:4 and finished fair and even without using extra cement with/without WPC complete all as specified and directed by Engr-in-Charge (WPC where required shall be measured and paid separately)
Supply only integral water proofing compound of approved quality complete .
Cement concrete (1:2:4) type B-1 using 20mm graded mechanically crushed stone agg as in benching of manholes, coping, plinth course, bands, stops, hold fast etc. incl necessary form works complete all specified and directed by Engineer-in-Charges
PCC (1:4:8) type D-2 (using 40mm graded mechanically crushed stone aggregate) as in foundation of manholes complete all as specified and directed
Demolition by breaking up drain pipes salt glazed stone ware pipe 100/150/200 mm dia jointed in cement mortar and taking out of from trenches removing the debris from site complete all as specified and directed by Engineer-in-Charge
Reinforced cement concrete pipe NP3, conforming to IS : 458-2003, 300 mm bore laid and jointed in CM (1:1) complete including joint fitting all as specified.
Reinforced cement concrete pipe NP3, conforming to IS : 458-2003, 200 mm bore laid and jointed in CM (1:1) complete including joint fitting all as specified.
Reinforced cement concrete pipe NP3, conforming to IS : 458-2003, 150 mm bore laid and jointed in CM (1:1) complete including joint fitting all as specified.
Demolition of reinforced cement concrete of any description and in any position complete all as specified
Precast reinforced cement conctrete (1:2:4) type B-1 using 20mm graded mechanically crushed stone aggregate as in covers of manholes and set in CM 1:6 incl necessary from work and placing of manhole covers complete including marked "MES and month & year of replacement all as specified and directed by Engineer-in-Charge
8mm dia and over mild steel TMT bars as in reinforcement, cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns and binding with MS wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
Returning and filling including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed Engr-in-charge
Removing of excavated Material n.exc 50 m and depositing where directed at a level n.exc. 1.5 m above the starting point complete all as specified and directed..
Cleaning the sewage sump wells, septic tanks of any size, depth and in any location by taking out complete sludge water and solids of any description, mechanically by HCV mounted suction discharge machine having blow back facility with sludge tank of adequate capacity removing & disposing the entire retrieved material to a distance not exceeding 1000 meter outside the periphery of defence land and covering the entire sludge with local earth complete all as directed by the engineer-in-charge. Note: Depth of sludge in the pit shall be measured from bottom of pit to the existing water/affluent level prior to ordering the cleaning in the presence of EIC.
Cutting into existing manhole for connecting new drain of 150 mm to 300 mm bore pipe making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 rounds of ¾ section) in cement concrete 1:2:4 type B1 smooth finished reforming benching as required, complete all as specified.
Cast iron Nahani trap, 100 mm dia with long arm not less than 450mm, including grating including jointing to waste pipe fixed as in repair in cement concrete 1:2:4, type B I all as specified and directed.
Special type cast iron ‘P’ or ‘S’ trap 300mm to 450mm long tail suitable for 100mm dia CI pipe incl jointing to waste pipe in run lead fixed as in repair complete all as specified and directed
Cast iron soil, waste and vent pipe, 100mm bore, spun pipe in any length, with or without ears, with cement joints, fixed to walls with and including stack clamps, nuts , bolts etc. and making necessary connections complete including taking down old 100mm CI pipe all all as specified and directed.
Cast iron soil, waste and vent pipe, 75mm bore, spun pipe in any length, with or without ears, with cement joints, fixed to walls with and including stack clamps, nuts , bolts etc. and making necessary connections complete fixed as in repairall all as specified and directed.
Holder batten clamp suitable for 100 mm dia pipe, made out of mild steel flat iron 50 x 5 mm and 16mm dia round iron stays including nut bolts and securing ends of stays to wall or roof complete fixed as in repairall all as specified and directed.
CI Bends (any radius), for 100mm bore CI piipes diminishing pieces or tapers (larger bore measured) fitted with oval access doors complete all as specified.
Single Y-shaped CI junction pieces, ordinary or inverted (spigot or socket type) for 100mm bore pipes complete all as specified.
Cast iron junction combination 'T' equal or unequal for 100mm bore with access door as in repair complete all as specified.
Cast iron cowls of 100 mm dia complete all as specified and directed.
Salt glazed stone ware, gully trap square or round mounted type 'P' size 150 x 150 mm fixed in PCC 1:2:4 type B-I using stone aggregate complete fixed and jointed to drain pipe complete with CI grating all as specified and directed.
S&F plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes with TMT bar handles to be welded to plates as in Nahani trap cover, if reqd including frame work of angle, complete all as specified and directed by Engr-In-Charge complete. Note : TMT bars will be measured and paid separately.
Preparation of surfaces of steel surfaces of any description, over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified and directed.
PCC100mm thick (1:2:4) type B-1, (using 20 mm graded stone agg) as in road cuttings complete all as specified and directed by Engr-In-Charge.
Arneja Builders
m/s panchmukhi builders
Swami Engineers
M/S Mukesh Kumar Gupta
FAVOURITE ENGINEERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .