Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹62.1 LAccepted-AOC FLAT NO 1 PLOT NO 54 GRD FLOOR TULSI ASTHA NEAR SHRI ANAND RUSHIUDYAN SECTOR 12 VASHI NAVI MUMBAI 400 703 | THANE | MAHARASHTRA | 400703 | ₹62.1 L Quoted ₹64.0 L | L-1 | Accepted-AOC Being L-1 |
| 2 | L2₹64.4 L+₹41,520.50 (0.65%)Rejected-AOC | ₹64.4 L+₹41,520.50 (0.65%) | L2 | Rejected-AOC Being L-2 |
| 3 | L-3₹66.5 L+₹2.5 L (3.92%)Rejected-AOC ROOM NO 220 2ND FLOOR DEVGIRI BUILDING NO 65 B LALLU BHAI COMPOUND MANKHURD MUMBAI 400043 | MUMBAI SUBURBAN | MAHARASHTRA | 400043 | ₹66.5 L+₹2.5 L (3.92%) | L-3 | Rejected-AOC Being L-3 |
| 4 | L-4₹70.4 L+₹6.4 L (10.0%)Rejected-AOC UNIT NO 7 MOUNT VIEW CO OP HOUSING SOCIETY LIMITED MUMBAI MANKHURD 400 088 | MUMBAI SUBURBAN | MAHARASHTRA | 400088 | ₹70.4 L+₹6.4 L (10.0%) | L-4 | Rejected-AOC Being L-4 |
| 5 | L-5₹71.0 L+₹7.0 L (10.9%)Rejected-AOC 1ST FLOOR SIDDHI PUJA BUSINESS SQUARE SONY PAITHANI CHOWK NASHIK MAHARASHTRA INDIA PIN 422 002 | NASHIK | MAHARASHTRA | 422002 | ₹71.0 L+₹7.0 L (10.9%) | L-5 | Rejected-AOC Being L-5 |
Tender Value
Refer Docs
EMD Value
₹1.5 L
Closing Date
17 Aug 2022, 6:00 pmClosed
CWE (SUbs) Mumbai
Commander Works Engineer Subs NCHC Powai Bhandup Post Office Mumbai 400 078
SPECIAL REPAIR TO BUILDING NO P-05 MAIN TRANSMITTING STATION AT TS MAHUL, MUMBAI
2022_MES_522331_2
8824/E8
Open Tender
Civil Works
Item Rate
270 days
Mankhurd
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE (NW) Mankhurd
₹1.5 L
Yes
28 Sept 2022
29 Jul 2022
20 Aug 2022
29 Jul 2022
17 Aug 2022
5 Aug 2022
Amount
Use and Waste for providing and erecting safety net of opening 75x75 mm in addition vertical fisher net arrester horizontally or vertically throughout to prevent debris falling while execution of work / absorb the debris stone impact . The work should be carried out with all the safety measures like helmet ,safety belt complete all as specified and directed.
Chipping, removing carefully loose/ damaged concrete (total thickness upto 60mm ) from surfaces of RCC members, in any location by low impact Hammer/Breakar without damaging the structure & cleaning the surfaces with wire brush etc and disposal of debris out side MOD land complete all as specified and directed.
M&L for cleaning existing reinforcement with wire/ rotary wire brush to a shining bright finish, making the surfaces free from loose material, dirt etc complete and applying two coats of alkaline rust converting primer conforming to ASTM-B-117 of make. "Feovert" of "Krishna Conchem" OR "Roff Rust Cleaner' of 'Pidilite' OR 'Shali Rustoff' of 'STP Ltd', on rebars with time interval of 1 hr between the coats, complete all as specified and directed. (Note :- Mode of measurement: superficial area of concrete will be measured.)
M&L for Anticorrosive Treatment to Reinforcement using IPNET-RB of M/s Krishna Conchem or Epoxy Zinc Primer of M/s. Dr. Fixit by application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces, complete all as specified and directed. Note:- Mode of measurement: superficial area of concrete will be measured.
M&L for shear connectors of 8mm dia TMT bars including anchoring of the reinforcement bars in existing RCC members by providing holes of minimum 10d depth and grouting in position with locfix (fosroc), including drilling of holes, cleaning and other relevant works, complete all as specified and directed.
M&L for Epoxy bond coat of Make Fosroc (NITOBOND-EP) OR EPOXY BONDING AGENT of Dr. Fixit OR equivalent of M/s. Krishna Conchem as approved by GE over exposed concrete surfaces prior to application of any type of mortar to ensure bond between old concrete & new concrete by brush application, complete all as specified and directed.
M&L for making up for lost section of concrete / mortar with thixotropic repair mortar is one component thixotropic dual shrinkage compensated fiber reinforcement fromulation for structural build up section by hand packing as per manufacturers applied by mean of hand gloves by expert applicator , the rehabilitated surface should be free form air gaps , voids should be in line with existing surface , inlcuding curing , cleaning from manufacturers M/s. Krishna Conchem (Molith PMM) OR Polymer mortar HB of Dr Fixit, , including levelling, profiling etc, complete all as specified and directed.
M&L for casting & repairing of excessively damaged distressed RCC members (exceeding 40mm in thickness) with prebatched, prepacked, single component ready to use microconcrete from Fosroc (Renderoc RG) or equivalent of Dr. Fixit as approved by GE, at any level/ height and at any lead or lift as directed including prefabricated water tight formwork, centering, scaffolding, also including mixing , laying, levelling, finishing, curing etc as per manufacturer's specifications and all other relevant works, complete all as specified and directed. (Note : Reinforcement only shall be measured and paid separately)
M&L building up the profile of structural members using polymer modified mortar of Krishna Conchem (Molith PMM) or polymer mortar HB of Dr Fixit while the bonding agent is tacking upto 40 mm thickness (of 20x20 mm each in 2 layers) including levelling ,profiling formworking ,scaffolding etc complete all as specified and directed.
M&L drilling and fixing Teflon perforated nozzles in RCC member , inlcuding drilling 14 mm dia 50 to 100 mm deep holes in structural members at intervals of 600 mm or 2 nozzles per sqm in staggered manner after cleaning the holes by air blower further the external end of nozzles to be machined to receive outlet of grouting gun ,nozzle is fixed using epoxy sealant to ensure complete sealing and curing the whole affected area for min 12 hours complete as directed by the Engr in Charge and consultants in RCC structural elements .
M&L injecting low viscosity epoxy resin of Dr Fixit Epoxy injection , EPCO -KP-HP -250 of M/s Krishna Conchem Products Shaligrout EI of STP Ltd with an injection pump , pumping shall be stopped once the pressure is felt and no more epoxy resin can be injected, allow resin to set for at least for 7 days , after cutting the ports/ nozzle , seal the grouting holes using epoxy putty ,seal putty shall be ground off with a rotary scrubbing machine. Note: Item No 01 to 11 (structural repair works ) will be carried out through an authorised agency as approved by the GE and the contractor shall get prior approval of the GE before commencement of the execution of the work /repairs included in the scope of these items.
M&L for providing and applying a single coat of bonding agent Plast -O- Grip on base concrete , bricks or mortar blocks by brush or spray and applying cement plaster thereof when bond coat is tacky. Complete all as specified and directed.
Demolition of reinfoced cement concrete of any description and in any position not otherwise specifically provided for including cutting of the reinforcement to facilitate demolition and removing the retreived debris out side MD land, complete all as specified and directed.
M&L for TMT steel bars 10mm dia and over in reinforcement cut to length, bent to shape required, including cranking bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc, complete all as specified and directed. Note : This item is applicable for new RCC Members as well as for provision of additional steel bars in the existing RCC Members.
Ditto but 5 mm over upto and including 10 mm dia in stirrups, spacers and binders.to 8 mm dia , complete all as specified and directed.
M&L for RCC M30 (Design mix) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M&L for RCC M30 (Design mix) in Beams, cantilevers, bressummers, lintels over 1.5m span and the like complete all as specified and directed.
M&L for RCC M30 (Design mix) as in chajjas, complete all as specified and directed.
Use and waste of Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers,lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for rough finished surfaces of flat concrete.
Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landinqs and similar work; not exceeding 200 mm thick (Horizontal or sloping for rough finished surfaces of flat concrete.
Use and waste of formwork to chullah hoods, chajjas, troughs and similar items including edges for rough finished flat surfaces of the concrete, complete all as specified and directed.
Demolition of brickwork built in cement mortar including disposal of debris, etc outside MD land complete all as specified and directed.
M&L Brickwork with subclass `B' bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed.
Dismantaling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering complete all as speicifeid.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed
Dismantling mild steel work as in angles, brackets of valley gutter etc of any description and in any position. complete all as specified and directed
S&F roof trusses (framed), trussed purlins crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc. FE -410W Gde E-250 quality A complete all as specified and directed
M&L preparing new steel surfaces of any description exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zink chrome primer complete all as specified and directed
S&F 'Fe 410-W (Gde E-250) quality A Mild steel plates, plain or chequered, 5mm thick or over in thickness in available sizes complete all as specified and directed.
S&F framed work such as grills, gratings, etc. with ends of bars shouldered and / or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe 290- Gde E -165 complete all as specified and directed
Demolition of wall and ceiling boards (fibre, pulp , insulation , etc.) or insulation boards /slabs/blankets, any thickness inlcuding cover fillets complete all as specified and directed
S&F 605 X605 mm Anodised aluminium snap grid frame work for false ceiling and Hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling and cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long and providing and fixing of 12 mm thick Gypsum board fixed iwth screws as per manufacturer instructions for ceiling complete all as specified and directed.
Dismantling completely existing roof treatment (excluding cement screed bed ) including loosened cement plaster and exposing the top surface of RCC slab and making good the same in CM 1:4 and removing rubbish, etc to a distance exceeding 500m and not exceeding 1.0km complete all as specified and directed by the Engineer-in-charge
M&L complete surface preparation prior to further application using wire brush the surface ,ensure complete crack filling using polymer modified mortar of Dr Fixit Crack -xX Paste, Dr Fixit Crack -X Shrinkate of Shaliseal CPM from STP Ltd ,allow to dry it for 24 hrs afterwards wet the surface , brush apply 1 primer coat of Dr Fixit Primeseal or equivalent primer ,over that brush apply 1 coat of water proofing coating over the primed surface , over that over lay a open woven fibre glass mesh , min 40 GSM of size 2 mm x 2 mm & allow it to soak completely and immidiately apply the second coat of Dr Fixit New coat , Water seal concerntrate of M/s Krishna Conchem Products, Shalicryl 215 of STP Ltd with a roller , to ensure complete coverage of the fibre mesh. complete all as specified and directed
M&L for 10 mm thick screed bed layer in CM (1:3) with WPC when the concrete is still green complete all as speicified and directed. Note : WPC will be measured and paid separately.
Taking down chowkats or frames, not exc 1.5 sqm each with wooden/ flush/ PVC shutters (Without taking off shutters from the frame) including taking down of hold-fasts by cutting/chasing etc from existing surfaces and also taking down of MS Grills (where exists), complete all as specified and directed.
Taking down chowkats or frames, exc 1.5 sqm but not exc 4 Sqm each with wooden/ flush/ PVC shutters (Without taking off shutters from the frame) including taking down of hold-fasts by cutting/chasing etc from existing surfaces and also taking down of MS grills (where exists), complete all as specified and directed.
Taking down the grill not exceeding 2sqm each.incl taking down grill and refixing the same in the same opening after complete cleaning and when the repair work is complete or as and when directed by the Engr in Charge.
Taking down existing aluminium windows/doors with aluminium frames (without taking off shutters from the frame) exceeding 1.50 Sqm and not exceeding 4 Sqm each incl taking down grill (where exists) and refixing the same in the same opening after complete cleaning and completion of repairs to plaster etc, complete all as specified and directed.
M&L for Double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel, heavy duty, complete all as specified and directed.
S&F standard aluminium section powder coated (minimum thickness of powder coating shall be 50 micron and colour shall be as approved by GE ) as in frame, shutters for doors, window / ventilators, partitions, fixed / openable / sliding or in any pattern, cut to size, jointed with cadmium plated steel screws, including rubber beading or gaskets for fixing glass, provision of hinges, screws, plugs, handle, lock, roller, Nylon ball bearing etc complete all as specified and directed (Aluminium section shall be of make Jindal/Hindalco/ Indalco) Note:- Weight of Aluminium sections as per actual or as per IS or as per manufacturer, whichever is less, shall only be considered for payment. Cost of other items / accessories required for entire completion of the work shall be deemed to be included in the quoted rate. However glass panes and wire cloth shall be measured and paid separately as supply only under respective items.
S&F aluminium anodised Grills of approved design with and including F/U channel for window, ventilators, balcony openging in architectural or rectangular type in existing building, including drilling as required in RCC sections, complete all as specified and directed. Note: The Grills shall be of Model DG-102/DG-104 of Make Deco or equivalent make as approved by the GE.
S & F Factory made solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, complete all as specified and shown in drg for SI No. 8095 on ser page No. 180 in SSR-2020 (Pt-II).
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S.frame shall be covered with heat moulded plain colour PVC`C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour PVC sheet shall be fitted in the M.S. frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement as per specification & drawing-for S.I. No. 8080 on Sr page No. 176 in SSR-2020(Part II) complete all as specified and directed.
M&L for kiln seasoned and chemically pressure treated second class Hard Wood (SAL/Hollock/Kalasiris) plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue, pinned at joints etc complete all as specified and directed.
S&F Flush shutters, solid core construction, with block board core and one face is covered with decorative face veneer with lipping/frame to match and other face commercial ,30 mm thick complete all as specified and directed
S&F 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clip of sheet,cast or extruded section and fixing bolt of extruded section or cast aluminium alloy, complete all as specified and directed.
S&F 100mm long Stainless Steel hinges, complete all as specified and directed .
S&F 150 mm long aluminium anodised barrel tower bolts of extruded section, complete all as specified and directed.
S&F 200 mm long aluminium anodised barrel tower bolts of extruded section, complete all as specified and directed.
S&F 150 mm size extruded aluminium alloy handles, fabricated type, anodised, complete all as specified and directed.
M&L for preparation of new wood and wood based surfaces of any description over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer, complete all as specified and directed.
S&F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required:hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165, complete all as specified and directed.
M&L for Cast in situ PCC 1:2:4 type B-1 (using 20mm graded stone aggregates) as in coping, bed blocks, roof curb, mud stops, coving at junction of wall and chajjas etc including weathering, slightly rounded or chamfered angles, provision of necessary form work, complete all as specified and directed.
M & L for machine cut cudappah stone slab 20 - 25 mm thick laid over 15mm thick cement rendering in CM 1:4 as in cills, jambs soffits, cooking platform laid and jointed with grey cement slurry mixed with pigments to match the shade of the slab including rubbing and polishing complete all as specified and directed by the Engineer-in-charge
Supply only 4.8mm thick plain sheet glass, ordinary quality for aluminium joinery, complete all as specified and directed.
Supply only aluminium wire cloth 0.45mm nominal dia of wire and average width of aperature 1.40mm for aluminium joinery, complete all as specified and directed.
Taking down cement plaster or lime plaster on walls /ceiling of any description from concrete or brick wall etc including raking out joints, hacking for key, scrubbing down with water and disposing off the retreived debris out side MD land including necessary scaffoldings etc complete all as specified and directed
M&L for 12 mm thick polymer modified ready mix cement based plaster on the wall surfaces including finishing surfaces even and smooth, complete all as specified and diected Make: Easy Plast from M/s wall plast or chemplast or readyplast from Ultratech Note: The thickness of plaster specified above is the minimum thickness and the quoted rates shall also be deemed to include for provision of dubbing of the surfaces with ready mix plaster and nothing extra shall be payable on this account.
M&L for rendering 5 mm thick in cement mortar (1:3) to ceiling, finishing the surfaces even and smooth without using extra cement, complete all as specified and directed.
M&L for leakage / seepage proof coating consisting of preparing the new surfaces of existing exterior walls, parapet walls, chajjas etc. and applying Primeseal primer of M/s Dr Fixit or equivalent chemical of M/s STP Ltd as approved by the GE or one coat of Chemstic PDE 600 elastomeric coating (and allowing to dry for 8hrs) under torch dry condition and subsequently applying two coats of water proofing decorative elastomeric coating system Raincoat of M/s Dr Fixit with DFT 100microns or Shalicryl 215 of M/s STP Ltd or Chemstic PDE 600 elastomeric coating (the surfaces after painting one coat shall be allowed to dry for 6 to 8hours before application of next coat) including necessary scaffolding etc complete all as per manufacturer instructions, as specified & directed. Note: The aforesaid treatment shall be got executed by the contractor from the authorised applicator of the manufacturer(s) and also necessary authenticated documents on account of above shall be submitted by the contractor to the GE.
M&L for 3 mm thick (minimum) white cement based wall care putty on new or old surfaces of walls/ceilings etc, finished even and smooth, to bring the surface in Plumb line complete all as specified and directed.
M & L for preparation of new plastered surfaces of wall and applying two coats of distemper oil emulsion with roller over one coat of primer, complete all as specified and directed.
M & L for preparation of new plastered surfaces of ceiling and applying two coats of distemper oil emulsion with roller over one coat of primer, complete all as specified and directed.
Demolition of slabs and tiles of any description or thickness in floors, aprons, Dados and Skirting including cement mortar bedding / backing, removing rubbish off the premises outside MD Land, complete all as specified and directed.
M&L Screed bed or bedding layer or mortar 15mm thick for laying floor finishes in CM 1:6 complete all as specified and directed
M&L rendering 10 mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finished even and smooth without using extra cement complete all as specified and directed
M&L for coloured 300x450x7mm thick glazed ceramic tiles on vertical surfaces such as skirting,dado etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match with the colour of tiles, over and including 10mm thick cement mortar backing coat in CM 1:4, complete all as specified and directed.
M&L for coloured Non-skid ceramic tiles 7 to 8 mm thick (square/ rectangular) of approved size, area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floors etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match with nthe colour of tiles, over and including 15mm thick cement mortar screed bed in CM 1:6, complete all as specified and directed.
M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete and rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations ccomplete all as specified and directed.
M&L for Vitrified Ceramic tiles 10mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match ,light shade.
Demoliton of Cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level)
M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80mm thickness, M-40 Grade,with grey cement and pigment complete all as specified and directed.
M&L Sand filling under floors or in foundation including watering and consolidation complete all as specified and directed.
M&L 75 mm thick Cement Concrete in sub base of floors type D-2, PCC 1:4:8 ( 40mmgraded aggregate ) complete all as specified and directed
Demolition of cement concrete of any description and in any position not otherwise specifically provided for and removing the retreived debris out side MD land, complete all as specified and directed.
S&F in repair 15mm bore brass CP stop valve, Make ESSCO Cat No MQT-513 A or equivalent of make Parko/ Zoloto as approved by the GE, complete all as specified and directed.
S&F in repair Grating doom 100 mm dia with waste hole of PTMT (Minimum Weight 25 gram), complete all as specified and directed.
S&F in repairs 15mm bore brass CP pillar tap, Make ESSCO Cat No MQT-507 or equivalent of make Parko as approved by the GE, complete all as specified and directed.
Taking up or down steel water tubing and connections of size 15mm bore, complete all as specified and directed.
Taking up or down steel water tubing and connections of size 20mm bore, complete all as specified and directed.
Supplying and laying 16mm bore of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. and as directed.
Supply & fixing 20mm bore GI tubing, medium grade with and including all fittings and fixed to walls and ceilings or laid in floors complete all as specified and as directed.
S & F of 75 mm bore PVC (SWR) soil, waste, ventilating rain water pipe type 'A', single socketed, (ISI Marked) in any length with and including ruber ring joints, complete fixed to wall with necessary PVC standard stay clamps etc, including taking down existing SWR pipes(including fittings) of any description, complete all as specified and directed.
S & F 110 mm bore PVC (SWR) soil, waste, ventilating, rain water pipe type 'A', single socketed, (ISI Marked) in any length with and including ruber ring joints, complete fixed to wall with necessary PVC standard stay clamps etc, including taking down existing SWR pipes(including fittings) of any description, complete all as specified and directed.
S&F 75 mm bore PVC (SWR) Bends with and including oval access door and also including rubber ring joints, complete all as specified and directed.
S&F 110 mm bore PVC (SWR) Bends with and including oval access door and also including rubber ring joints, complete all as specified and directed.
S&F in repairs, white, vitreous China, wash down water closet pan (pedestal pattern), Ist quality, inlcuding plastic water closet seat white, closed pattern with flat bottom and cover and Mild Steel CP or aluminised hinging device, complete all as specified and directed. Note: Flushing cistern, flush pipe will be measured and paid for separately.
S&F in repair Vitreous China wash basin, white, flat back, size 550x400mm but including brackets, coupling and waste pipe complete
S&F cast iron Nahani trap with 75mm dia out let including grating, connecting, jointing to waste pipe with lead joints, also including embedding the same in PCC 1:2:4 type B-1 (using 20mm graded stone aggregates) mixed with water proofing compound in the proportion as recommanded by the manufacturer(s), taking out existing unserviceable traps by hacking out concrete joints and making good of surfaces, complete all as specified and as directed .
M&L for 15 mm dia Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified , Cat No 187 of Prayag or equivalent make as approved by the GE complete all as speicified
S&F 20 mm dia brass chromium plated tubular towel rail 'D' type 600 mm long between flanges, complete all as specified and directed.
S&F in repairs flushing cistern, 10 Ltrs. Capacity, PVC valveless, syphonic action type with dual flushing system, low level,white with inlet, ball valve,float and handle including brackets, flush pipe of polyethylene of low or high density or PVC, 32mm dia, complete all as specified and directed.
S&F in repairs PVC connections 15mm size with PTMT nuts of length 450mm, complete all as specified and as directed.
S&F in repairs gun metal gate valve, ISI marked with iron wheel head, screwed at both ends for iron pipe or ferrule of 20mm bore and provision of necessary fittings like unions, check nuts, etc, complete all as specified and as directed.
S&F two way Bib cock of Pryag make Cat No SQT-512 ANKN or of ESSCO or equivalent of Marko ,Parko as approved by the GE complete all as specified and directed.
S&F steel rolling shutters in repairs without ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer, erected in position as indicated, complete; push pull or manual type, 1.25mm thickness of lath, complete all as specified and directed.
M&L for providing 75mm thick PCC (1:3:6) type C1 (using 20mm graded stone aggregate) as in plinth protection, surface finished even & smooth without using extra cement including provision of 10 mm joints (at an interval of 3 metre and turnings) duly filled with fine sand and bitumen in the ratio of 3:1 ,complete all as specified and directed.
M&L for Cement concrete in surface channels and drains type C2 1:3:6 (using 40mm graded stone aggregate) including provision of necessary form work, complete all as specified and directed.
Extra for forming fair finished drain or channel min 30cm inner girth in cement concrete using extra cement, including forms, moulds, mitred/ stopped ends etc, complete all as specified and directed.
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar of 150 dia pipe, complete all as specified and directed.
M&L for Salt Glazed, Stoneware, Drain pipes of 150mm bore, grade 'A', laid in trenches and jointed, complete all as specified and directed, Note: Excavation & earth work and PCC for bedding & haunching shall be measured and paid for separately.
M&L for 100mm thick concrete bed in cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) for 150mm bore pipes including packing under and haunching against the sides of pipes after they are laid and tested etc, complete all as specified and directed.
Excavation in trenches not exc 1.5m wide and not exc 1.5m in depth for pipes, foundation etc and not 10 Sqm on plan and not exc1.5 metre in depth for pits, independent holes etc, including getting out in any type of soil, complete all as specified and directed.
Returning, filling in with approved earth including spreading, levelling, watering, well ramming in layers n exc 25 cm thick, complete all as specified and directed.
Removing excavated material/soil to a distance not exceeting 50 metre and depositing where directed at a level not exc 1.5 metre above the starting point, complete all as specified and directed.
Dismantling existing water tanks of capacity exc 250 ltrs and not exc 500 ltrs, complete all as specified and directed
Supplying and fixing rotational moulded polythylene water storage tanks, double layered (ISI marked) of 500 litres capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I, including provision of necessary fittings for connecting the overflow, drain out, inlet and outlet pipes, complete all as specified and as directed.
S&F Ball valve, high pressure of PTMT fixed with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe of 25 bore (minimum weight 455gms), complete all as specified and as directed.
Supply only Integral water proofing compound
Taking down carefully point wiring of any type & pattern (Light/Fan/Socket or power) including fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings of any type etc and making good disturbed surfaces of walls/ roof etc, complete all as specified and directed.
Taking down complete main switches/DBs with enclosure and its components of any size and capacity ,etc complete all as specified and directed.
M & L for point wiring complete with proper colour coding using, 1100 Volts grade, 1.5 Sqmm, PVC insulated FRLS, unsheathed wire with multi stranded copper conductor confirming to IS-694, Part II, ISI marked drawn in and including PVC casing caping (minimum 20mm width) fixed on the surfaces of wall, ceiling etc with all accessories, fittings, PVC junction boxes etc, sunk pressed steel boxes not less than 2 mm thick, 50 mm deep terminal boxes covered with 3mm thick plastic laminated hylam sheet top cover fastended with chromium plated brass screws, also including 1.5 Sqmm, PVC insulated, FRLS, unsheathed, 1100 Volts multistranded copper conductor green colour as continuous earth wire connected to common earth dolly all as specified and directed for one light point /fan/bell point controlled by one one way switch, complete all as specified and directed. Note : 1. Two runs of cable, one run of earth wire, one run of PVC casing capping will be measured and paid one unit.
-ditto- all as per item No. 115 above but for One 2pin/3 pin socket outlet 5 Amps on same board complete all as specified and directed.
-ditto- all as per item No. 115 above but for One 2 pin/3 pin socket outlet 5 Amps on independent board.
M&L for point wiring using proper colour coding with 1100 Volts grade, 2.5 Sqmm PVC insulated, FRLS, unsheathed, wire confirming to IS-694, Part-II, ISI marked with multistranded copper conductor drawn in and including PVC casing caping (minimum 20mm in width) fixed on the surfaces of wall, ceiling etc with all accessories, fittings, PVC junction boxes etc, sunk pressed steel terminal box not less than 2 mm thick, 50 mm deep, covered with 3 mm thick plastic laminated hylam sheet top cover fastened with chromium plated brass screws, also including 1.5 Sqmm, PVC insulated, FRLS, unsheathed, multistranded, copper conductor 1100 Volts grade, green color, continuous earth wire connected to common earth dolly for 15 Amps, 3 Pin, socket outlet independent complete all as specified and directed. Note : 1. Two runs of cable, one run of earth wire, one run of PVC casing capping will be measured and paid one unit.
S&F Switch Piano 5 Amps, 250 Volts, one way, flush type, complete all as specified and directed.
S&F Switch Socket combination 2 in 1 , 5 Amps, flush type, 5 Pin, 240 Volts, ISI marked complete all as specified and directed.
S&F Switch Socket combination 2 in 1 , 5/15 Amps, flush type, 6 Pin, ISI marked complete all as specified and directed.
Supply & Fix Bell push, flush type, 5 Amp, 230 Volts, ISI marked complete all as specified and directed.
S&F ceiling rose three terminal, 230 Volts PVC / Polycarbonate body, ISI marked complete all as specified and directed.
S&F fan regulator, electronic stepped (5 step), 230 volts, 100 watt, flush type and connecting-up, ISI marked complete all as specified and directed.
Supply and fix bell dig dong, AC, 230 V, single pole, complete all as specified and directed.
S & F surface/wall mounted LED batten fittings 20 W capacity made of polycarbonate co extrusion tube for LED light housing with engg plastic end caps having high efficiency, long life LED chips with luminous efficacy not less that 100 lm/W, and having CCT white 6000+500K, Constant current driver operating range 140-270V AC supply voltage, PF> 0.9, IP 20 including electrical connection with 3 core flexible copper conductor cable of appropriate size from ceiling rose to the fixture complete all as specified ad directed. Make: Bajaj Cat No BCLSB 20 WH or equivalent model of Jaguar/Wipro/Philips/Surya. Note :- (i) LED fitting/fixtures supplied should be along with LM-79 & LM-80 test certified from NABL certified laboratory. (ii) The contractor / tenderer shall produce return warranty certificate for 05 years on his company / firm letter head alongwith warranty certificate issued by the OEM of LED fitting/fixtures for 05 years.
S & F 10W surface/wall mounted LED batten made of polycarbonate co extrusion tube for LED light having with plastic end caps having high efficiency long life LED chips with luminous efficacy not less than 100 lm/W and CCT white 6500+510K, Color rendering index >80, operating temperature - 100 to 450 C input voltage 100 to 300 V AC, Frequency 50/ 60Hz, Power factor > 0.90, THD < 20%, built in surge protection 3.5 KV, IP 20 including electrical connection with 3 core flexible copper conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed. Make: Bajaj Cat No BCLSB 10 WH or equivalent model of Jaguar/Wipro/Philips/Surya. Note :- (i) LED fitting/fixtures supplied should be along with LM-79 & LM-80 test certified from NABL certified laboratory. (ii) The contractor / tenderer shall produce return warranty certificate for 05 years on his company / firm letter head alongwith warranty certificate issued by the OEM of LED fitting/fixtures for 05 years.
Taking down old unserviceable ceiling fan 1200 mm sweep by disconnecting the electric power supply, unscrewing the bolts and nuts, removing the blades and transporting to workshop to undertake repairs by rewinding of burnt out winding using suitable gauge copper wire, replacement of worn out capacitor 2.5 mfd - 01 No., PVC canopy - 02 No and bearing including scrapping of old paint and applying two coats of synthetic enameled white paint over a coat of red oxide primer complete and re-fixing back at site with new clamps, nuts, washers, safety wire of size not less than 1.00mm & bolts including cotter pin for complete all as directed.
S & F MCB DB, 4 way, TPN, double door, 415 Volts and including cutting chases in wall, concealing DB in wall, making good the disturbed surfaces and making all connections complete all as specified and directed. Note: Quoted rate shall be deemed to include for provision of copper bus bar of 200 Amps rating.
S & F MCB DB, 4 way, SPN, double door, 240 Volts and including cutting chases in wall, concealing DB in wall, making good the disturbed surfaces and making all connections complete all as specified and directed. Note: Quoted rate shall be deemed to include for provision of copper bus bar of 200 Amps rating.
S & F MCB DB, 8 way, SPN, double door, 240 Volts and including cutting chases in wall, concealing DB in wall, making good the disturbed surfaces and making all connections complete all as specified and directed. Note: Quoted rate shall be deemed to include for provision of copper bus bar of 200 Amps rating.
S & F MCB DB, 12 way, SPN, double door, 240 Volts and including cutting chases in wall, concealing DB in wall, making good the disturbed surfaces and making all connections complete all as specified and directed. Note: Quoted rate shall be deemed to include for provision of copper bus bar of 200 Amps rating.
S & F MCB, TPN 63 Amps, 415 Volts, 10 KA Breaking capacity, C-series, complete all as specified and directed.
S & F MCB, SP, 05 to 32 Amps, 240 Volts, 10 KA Breaking capacity, C-series, complete all as specified and directed.
S & F MCB, SPN, 40 Amps, 240 Volts, 10 KA Breaking capacity, `C' series, complete all as specified and directed.
M&L for sub main wiring with two single core 6.0 Sqmm PVC insulated FRLS multistranded flexible copper conductor cable 660/1100 volts grade down in through non metalic PVC casing caping of size 25mm with and including PVC insulated 6.00 Sqm single core single strand copper conductor as continous earth wire in green colour connected to common earth dolly all as specified and as directed Note : 1. Two runs of cable, one run of earth wire, one run of PVC casing capping will be measured and paid one unit.
S&F in repairs single pole and neutral enclosure with a two pin and earth and metal clad plug socket complete with one single pole MCB 20 Amp 240 Volts complete all as specified.
supply & fixing GI Cable Tray with Cover Size 300mmX 100 mm including spacers screws, saddles nut bolt ,clamp etc for fixing the trunking in wall/GI sheets of shed all as specified and as directed
Taking down of existing GI Cable tray any type any size and re-fixing of the same GI Cable tray any type any size including spacers screws, saddles for fixing , after preparation of surfaces, complete all as specified and directed.
Taking down of existing XLPE Cable 6 sqmm to 50 sqmm any core and re-fixing of the same XLPE Cable any type any size including spacers screws, saddles for fixing , after preparation of surfaces, complete all as specified and directed.
Taking out old unserviceable underground cable XLPE insulated, PVC sheathed armored heavy duty aluminum conductor LT 1100 Volts grade of size 2 Core 6 Sqmm, fixed on pole, wall and laid in trenches etc after disconnecting Note - Excavation and earth work will be mesured and paid seprately.
All as per item no 141 but of size 4 core 25 Sqmm
All as per item no 141 but of size 2 core 10 Sqmm
All as per item no 141 but of size 3.5 core 35 Sqmm
All as per item no 141 but of size 2 core 4 Sqmm
Supply & Laying XLPE insulated, armoured, heavy duty, 1100 volt grade electric LT UG cable with multi stranded copper conductor of size 6 Sqmm, 2 Core, saddling the cable in duct/wall etc and making all connections and also taking out existing LT cable, complete all as specified and directed. Note:- Unless otherwise directed, the cable shall be in single piece.
Supply & Laying XLPE insulated, armoured, heavy duty, ISI marked 1100 volt grade electric LT UG cable with multi stranded copper conductor of size 25 Sqmm, 4 Core, saddling the cable in duct/wall etc and making all connections and also taking out existing LT cable, complete all as specified and directed. Note:- Unless otherwise directed, the cable shall be in single piece.
Supply & Laying XLPE insulated, armoured, heavy duty,ISI marked 1100 volt grade electric LT UG cable with multi stranded copper conductor of size 10 Sqmm, 2 Core, saddling the cable in duct/wall etc and making all connections and also taking out existing LT cable, complete all as specified and directed. Note:- Unless otherwise directed, the cable shall be in single piece.
Supply & Laying XLPE insulated, armoured, heavy duty, ISI marked 1100 volt grade electric LT UG cable with multi stranded copper conductor of size 35 Sqmm, 3.5 Core, saddling the cable in duct/wall etc and making all connections and also taking out existing LT cable, complete all as specified and directed. Note:- Unless otherwise directed, the cable shall be in single piece.
Supply & Laying XLPE insulated, armoured, heavy duty, 1100 volt grade electric LT UG cable with multi stranded copper conductor of size 4 Sqmm, 2 Core, saddling the cable in duct/wall etc and making all connections and also taking out old unsv existing LT cable, complete all as specified and directed. Note:- Unless otherwise directed, the cable shall be in single piece.
S&F in repairs LED street light complete made out of pressure die cast housing with prismatic polycarbonate modular secondary lens optics with IP 66 ingress protection having 4 KV inbuilt and 10 KV external surge protection device with top opening driver cover having efficacy not less than or equal to 110 lm/watt and having CCT 5700K, with all accessories, pre-wired, also with and including GI steel tube light grade 40mm bore bracket of length upto 1.50 metre, bent to shape of off set angle upto 45 degree for fixing street light fittings including necessary MS Clamps, nuts, bolts etc, all as specified and directed, Cat No ENXT P 54L WH PO PC SD of Bajaj or equivalent from Philips/Jaguar /Crompton as approved by the GE.
Supply and fix in repair MCCB 100 Amp 4Pole 415 Volt 25KA with and including CRCA powder coated 2mm thick enclosure with front openable door wall mounted type with chequred base plate for cable entry,including taking down of old MCCB of any size and reconnecting the cable with proper gland
M&L for new earthing complete with copper earth plate electode 600 x 600 x 3.15 mm thick buried directly in ground, earth pit not less than 2.25 meters deep below ground level, connected to and including copper earth strip 32mm X 6mm to the extent upto 7.5 metre as earth lead by means of bolts, nuts etc, with provision of charcoal and salt all as per electrical plate No 3 of SSR Part I, including water arrangement with GI pipe 20mm bore (medium grade), earth lead protection pipe 40mm bore light grade with bends, elbow etc. from earth plate to test point, excavation and earth work, returning, filling, ramming and removing of soil to a distance not exc 50 metre, making PCC 1:2:4 type B-1 pit (Earth chamber) with RCC 1:2:4 cover 50mm thick reinforced with XPM and testing on completion including making test point on wall as per SSR specifications all as specified and directed including taking down existing earthing. (Note: Cost of copper strip 32mm X 6mm and protection pipe upto 7.5 metre shall also be deemed to be included in quoted rate)
M & L for earthing chemical with copper plated 50 mm dia pipe 3 mtr long (100 microns) including Electrodite 50 Kg buried directly in ground including earth bore hole work (earth bore not less than 3 Mtr deep below normal ground level and connected to copper earth strip of size 20×3 mm by means of copper nuts bolts with washers and connected as per following specifications complete all as directed by Engineer-in-Charge. (a) In -Pipe Technology, Designed & Manufactured using M.S Pipes, Outer Dia is 50 mm with a wall thickness of 2 mm, Inner Dia is 26 mm with a wall thickness of 2.6 mm, Overall Length is 3000 mm, External Corrosion Protection: Copper Plated (100+ microns), Internal Corrosion Protection: In addition to Copper Plated (100+ microns), a ground breaking corrosion resistant Crystalline Conductive Compound is filled and compacted in the cavity within the pipes to enhance the electrodes performance. Conforms to IS: 3043 - 1987 i.e., Code Of Practice For Earthing (+ 10%) variations in dimensions applicable. (b) Electrodite backfill: Manufactured using Eco - Friendly minerals, Blended homogeneously with conductive carbon(s), Resistivity: < 5 ohm-metre (In ideal moist conditions); > 5 ohm-metre (Dry Conditions), Ph Value: 7.0 - 8.5, High water retention capacity, Hygroscopic, Ionic & Electronic conduction, Swells when it comes in contact with water thereby engaging constant contact between the electrode surface & soil which is a crucial aspect in the performance of an earthing system. Packing Size: 25 kilograms, Recommended for normal soil conditions. Conforms to IS : 3043 – 1987. Make: Ashlok or any ISO Certified approved make.
Supply & Fix copper strip of size 20 X 3.15 mm duly covered, fixed on porcelain insulators along the wall / roof / ceiling etc including connection to equipments body etc complete all as directed. Note : Cost of Porcelain insulators is deemed to be included in the quoted rate of the job
S&F in repair 36 watt recessed mounted 2 ft x 2 ft luminarie with deep drawn CRCA housing efficacy of not less than or equal to 120 lm/watt for false ceiling including connecting 1.5 Sqmm white colour PVC insulated three core flexible multi stranded copper conductor cable including fixing arrangement all as specified and directed in Engr-in-Charge. The fitting shall conform to Cat No BZRSQL 43L LED GX PRO WH of Bajaj or equivalent from Philips/Crompton/ Jaguar. Note :- (i) LED fitting/fixtures supplied should be along with LM-79 & LM-80 test certified from NABL certified laboratory. (ii) The contractor / tenderer shall produce return warranty certificate for 05 years on his company / firm letter head alongwith warranty certificate issued by the OEM of LED fitting/fixtures for 05 years.
Taking down of existing 25 KVA Servo Controlled Voltage stabilizers and re-fixing of the same including Connect to Change Over and connected to industrial plug and socket , after preparation of surfaces, complete all as specified and directed.
supply and fixing of change over switch 63 Amp,Three Pole & Neutral - 50 Hz, 415 V in sheet metal enclosure box with provision for fixing on wall including all necessary grouting, nut bolt clamp etc after preparation of surfaces,complet all as specification and directed
Taking down of existing Change over switch 63Amp and re-fixing of the same including connected to industrial plug and socket , after preparation of surfaces, complete all as specified and directed.
Taking down of existing MCCB 63 Amp with enclosure any type any capacity and re-fixing of the same including connected to industrial plug and socket , after preparation of surfaces, complete all as specified and directed.
Supply & fix Heavy Duty metallic Exhaust fan of sweep 300 mm sweep with frames, blades, mounting anchor fasteners, aluminium ouvers made of aluminium sheet of 0.5 mm thickness, provision of three core 1.5 Sqmm copper cable from ceiling rose to fan, making opening of required in cement mortar brick wall/RCC for fixing of exhaust fan, making good the distrubed surfaces in CM 1:4, including scafolding if any required to carry out the work in building of height up to 20 Meters complete in all respects the Exhaust Fan Shall Conform to Cat no EXHD300-4-1 of Crompton or Equivalent from Bajaj/GE
Supply and fix inreplacement 10 watt LED garden light pressure die cast powder coated housing with PC diffuser efficient light output LED with IP 65 protection including driver nut bolt ,washer base plate foundation 0.3mtr x 0.3 mtr x 0.3 mtr by PCC 1:2:4 type B-1 using 20mm grade stone aggegates of size including excavation and earth work , provision of GI bend of size 50MM dia in the PCC for cable entry the fitting shall conform to CAT No LBLA3-10-CDL of Crompton all as directed by EIC at site conforming or equivalent from Philips/Bajaj.
Dismantling of existing AHU complete for remove from AHU Room, including all cutting welding nut, bolt and worn part like bottom tray pedestral bearing, blower shaft etc and refixing the same in same position by reassambing at site including welding fabrication/ all parts at before including connecting the inlet and out let of pipes, cable and S& F of AHU bottom tray of existing size,new belt of existing size etc and testing complete all as specified and as directed. Note-:All material required for complete dismantling and installation of AHU though not mentioned,hererein before shall included in the quoted rate
Supply and fixing, Fabrication, Installation, Testing and Commissioning of ducting for supply/Return made out of GI steel metal 22 gauge, Zinc coated complete with all standard accessories, flanges, G I Hardware, Self Adhesive elastomeric foam gasket, support etc as per IS-655, complete all as specified and directed.
Taking down of existing AC ducting of any size any type unbolting and refixing the same at required hight including all necessary anchor support, nut bolts, etc to make the AC duct strongly fixed including insulation of (50mm thick) with resin bonded fiber glass wool roll of density 24 kg/cum, with factory laminated aluminium vapour barrier and cleaning the duct surface and taking special care so that all duct joints are sealed against any leakage and applying rubber based adhesive CPRX compound including aluminium foil tape 50mm wide to make the insulaton leakproof etc complete all as specified and directed.
Supply install, test and commissioning of Powder coated LT Feeder panel cubical in door type Channel mounted compartmentalized in construction all Confirming to IS 8623 Part 1 1993 CPRI approved factory fabricated made out of 2 mm thick CRCA Sheet with seven tank process & suitable size to accomodate all accessories / fittings, to accommodate incoming MCCB and TPN Copper bus bars, incomer MCCB and outgoing MCCB, MCB, Contactors The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator. The bus bar shall have copper extension links for connecting with out going MCCB. The cubicle shall have a bottom channel & free standing frame made of angle iron of size not less than 40mm X 40mm X 6mm but of A detachable predrilled gland plateof thickness not less than 3 mm thick powder coated should be used at the bottom for entry of armoured cable of adequate size with glands.The above panel shall be front & back openable lockable /openable by key from both side. The panel shall be Dust, vermin proof and powder coated of approved thickness complete including CTs, control wiring by 2.5Sqmm Wire and consisting the following, including taking down of old unsv panel after disconnecting Existing cables, and including provision PCC foundation, excevation, grouting bolts a) Electrolytic Copper bus bar 600 Amps for 3 phase and Neutral b) MCCB 4 Pole 320 Amps 415 Volt 36 KA (Thermal magnetic type, ICS = 100% Icu) – 01 No c) MCCB 3 pole 63 Amp, 415 Volt 16 KA (Thermal magnetic type, ICS = 100% Icu) – 10 Nos d) Digital Ameter -01 No, f) Digital Volt Meter - 01 No e) RYB LED Indicators - 1 Set
Supply install, test and commissioning of Powder coated LT Feeder panel cubical indoor type Channel mounted compartmentalized in construction all Confirming to IS 8623 Part 1 1993 CPRI approved factory fabricated made out of 2 mm thick CRCA sheet with seven tank process & suitable size to accomodate all accessories / fittings, to accommodate incoming MCCB and TPN Copper bus bars, incomer MCCB and outgoing MCCB, MCB, Contactors The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator. The bus bar shall have copper extension links for connecting with out going MCCB. The cubicle shall have a bottom channel & free standing frame made of angle iron of size not less than 40mm X 40mm X 6mm ut of A detachable predrilled gland plateof thickness not less than 3 mm thick powder coated should be used at the bottom for entry of armoured cable of adequate size with glands.The above panel shall be front & back openable lockable /openable by key from both side including provision of adequate hooks for lifting arrangements and provn of separate bus bar to be used as earth strip of panel. The panel shall be Dust, vermin proof and powder coated of approved thickness complete including CTs, control wiring by 2.5 Sqmm Wire and consisting the following, including taking down of old unsv panel after disconnecting Existing cables, and including provision PCC foundation, excavation, grouting bolts complete all as specified and directed.
a) Electrolytic Copper bus bar 1300 Amps for 3 phase and Neutral b) ACB with Microprocessor Release IPR E+ (4 Pole) 800 Amp (Thermal magnetic type) – 02 No c) Four Pole Changeover with Advance Neutral 800 Amp (Thermal magnetic type) – 02 Nos d) MCCB 4 Pole 320 Amps 415 Volt 36 KA (Thermal magnetic type, ICS = 100% Icu) - 02 Nos e) MCCB 3 pole 160 Amp, 415 Volt 35 KA (Thermal magnetic type, ICS = 100% Icu) - 03 Nos f) MCCB 3 pole 100 Amp, 415 Volt 35 KA (Thermal magnetic type, ICS = 100% Icu) - 02 Nos g) Digital Ameter -01 No, h) Digital Volt Meter - 01 No i) RYB LEDIndicators - 1 Set
Supply, laying and jointing GI tubes 25 mm bore medium grade in any lengths with screwed and socket joints, together with all galvanised steel fitting such as sockets, elbows, bends, tees, reducers, unions, cap plugs, nipple, short pieces etc fixed complete by means of and including clips, wall hook etc or laid in trenches all as specified and directed. Make - Jindal/Tata
All as per item no 168.00 above but of size 20mm dia.
S & F Gun metal gate valve of size 25 mm dia with iron wheel head screwed both ends for iron pipes complete all as specified and directed.
M & L for cutting of existing GI Pipe in position for inserting GI Tee complete with 100 mm dia union, nipple, etc all as directed for taking 25 mm GI branch line
M & L for Construction of new valve chamber of size 800 X 800 X 800 mm including necessary earth work in any type of soil, PCC foundation C-2 1:3:6 in base concrete, brick work in CM 1:6 with 10 mm thick plaster internally and 15 mm thick externally in CM 1:4, 6 mm thick MS cover with hinges and locking arrangement fixed to angle iron frame made-out of 40 X 40 X 5 mm MS angles complete with 2 coats of synthetic enamel paint over one coat of red oxide zinc chrome primer on all metal works & two coats of white wash on all plastered surfaces of valve chambers complete all as specified and directed by EIC.
ORIENT ELECTRIC CO
mp construction co
Joy builders
M/s Mohd Altaf Hanif Qureshi
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .