Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹52.2 LAccepted-AOC | ₹52.2 L Quoted ₹56.9 L | 1 | Accepted-AOC Being lowest rate quoted contractor L-1 |
| 2 | 2₹57.2 L+₹30,500 (0.54%)Rejected-Finance | ₹57.2 L+₹30,500 (0.54%) | 2 | Rejected-Finance Not lowest one |
| 3 | 3₹57.5 L+₹61,000 (1.07%)Rejected-Finance | ₹57.5 L+₹61,000 (1.07%) | 3 | Rejected-Finance Not lowest one |
Tender Value
₹49.9 L
EMD Value
₹99,720
Closing Date
15 May 2023, 5:00 pmClosed
Er.Harjot Singh Walia
Addl. Superintending Engineer, BC and Township Division, BBMB, Nangal Township.
Construction of 1 no. Conference Hall in Bhakra Sadan premises at Nangal Township
2023_BBMB_100629_1
774/23/TS
Open Tender
Civil Works
Tender cum Auction
365 days
Nangal Township
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,360
₹99,720
3 Jul 2025
13 Apr 2023
16 May 2023
13 Apr 2023
15 May 2023
13 Apr 2023
Amount
Civil Items (Schedule Items)
Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres. (CSR Item No. = 6.6)
Cement concrete 1:5:10 (b) With stone aggregate 40mm gauge (ii) mixing by mechanical means using concrete mixer volumetric type (CSR Item No. = 10.9 (b) ii)
Shuttring for faces of concrete foundations and foundation beams and plinth beam (vertical or battering). (CSR Item No. = 9.1)
Centring and shuttring for columns (Squares or Rectangular or poly gonal in plan) in first story (up to 4 mtr) (CSR Item No. = 9.4)
Centring and shuttring for columns (Circular or curved in plan) (up to 4 mtr) (CSR Item No. = 9.5)
Centring and shuttring for columns (Squares or Rectangular or poly gonal in plan) in first story (4 mtr to 5 mtr) (CSR Item No. = 9.4, 9.16)
Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels in first story (upto 4 mtr height). (CSR Item No. = 9.6)
Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. in first story (upto 4 mtr height). (CSR Item No. = 9.8)
RCC M-20 mechanically batch mixed using batch type concrete mixture as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centering and shuttering in foundation and plinth. (CSR Item No. = 10.15)
First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth. (CSR Item No. = 11.3 (i))
Damp proof course 4 cm thick of CC 1: 2: 4 with two coats of bitumen 20/30 penetration @ 1.65 kg per sqm laid hot and sanded. (CSR Item No. = 10.26)
First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level. (CSR Item No. = 11.4 (i))
115mm thick brick wall cement sand mortar 1:4 without reinforcement in super structure in first story (upto 4 mtr height). (CSR Item No. = 11.36)
Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. (CSR Item No. = 10.20)
Cold twisted deformed (Ribbed/ Tor Steel Bar) Bars Fe 500 grade as per IS 1786-2000, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete (CSR Item No. = 18.18)
Terracing consisting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg/sqm top of RCC slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing etc. (CSR Item No. = 13.13 (i))
Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. (CSR Item No. = 13.55)
Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16. (CSR Item No. = 13.45)
Providing and fixing 110 mm dia SWR U.P.V.C Rain water pipe (4.0 kg/cm2) as per IS:4985 including jointing during masonry complete as per specifications and to the entire satisfaction of EIC. (CSR Item No. = 13.74)
Providing and fixing 110 mm dia U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer-in-charge (a) upvc 110mm bend (CSR Item No. = 13.75 (a))
Plastering on underside of ceiling 10 mm thick cement plaster 1:4 (CSR Item No. = 15.44)
Plastering on walls 6 mm thick cement plaster 1:4 ( 0 to 4 mtr) (CSR Item No. = 15.3)
12.5 mm thick cement plaster 1:6 (CSR Item No. = 15.11)
20mm thick cement plaster 1:6 in two coats work (CSR Item No. = 15.28)
Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm gauge and 100mm fine sand filling using mechanical mixer for mixing of material (CSR Item No. = 14.3)
Providing and laying vitrified floor tiles of different sizes in light colour shades made using Double Charge technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. (Design is homogenous throughout the tile body). (a) Size 1000x1000mm (CSR Item No. = 14.113 (c ))
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. (i) Size 1000x1000 mm. (CSR Item No. = 14.120 ( c ))
Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/ Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 450 x 310 mm as approved by Engineer-in- Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. (CSR Item No. = 14.127)
Black Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps. (CSR Item No. = 14.87)
Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate z sections and other sections conforming to Is:733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. Aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing/ paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In- Charge. (Glazing and paneling to be paid for separately) a) For fixed portion and chaukhats (CSR Item No. = 17.45 (a))
Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate z sections and other sections conforming to Is:733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. Aluminum sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing/ paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In- Charge. (Glazing and paneling to be paid for separately) b) For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug / neoprene gasket required (CSR Item No. = 17.45 (b))
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic items) ii) Float glass panes of 5.0 mm thickness (CSR Item No. = 17.47(i))
Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in paneling fixed in aluminium doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on both side. (CSR Item No. = 17.46 (ii))
Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete B) 250mm x 16mm (CSR Item No. = 17.49-B)
Cost of Aluminum fittings complete for doors, windows such as tower bolts, handless, stoppers and screw etc. for these fittings (Excluding sliding bolt) (ii) For shutter area above 0.50 sqm (CSR Item No. = 17.23 (ii))
Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, for doors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single piece MS sheet outer box with slide plate and with stainless steel cover plate etc. complete as per the direction of Engineer-in-charge (CSR Item No. = 17.48)
Providing and fixing hydraulic door closer ISI mark with necessary screw etc. complete (c) I.S.I Designation No. III (size of door 851mm to 1000mm) (CSR Item No. = 17.43 (c))
Preparation of plastered or concrete surface for painting (including sand papering the surface) using Acryllic Wall Putty by applying two or more coats to get required finish including priming coat to make an even surface before applying Acrylic wall putty on new plastered surface. Complete as per specifications (CSR Item No. = 16.73)
Wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade (two or more coats) (CSR Item No. = 16.63)
Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two or more coats applied @ 1.43litre/10 sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 sqm. (CSR Item No. = 16.60)
Dressing of earth work:- New work or remodeling work. Unit (CSR Item No. = 6.3 (i))
Cement Concrete 1:8:16 (b) With stone aggregates 40mm gauge (ii) mixing by mechanically means using concrete mixer volumetric type. (CSR Item No. = 10.6 (b) (ii))
Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-35 grade machine made rubber moulded smooth finish with strong vibratory process or with vibrohydraulic compaction machine and of approved size and design / shape laid in Ordinary Grey and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge for Non traffic Areas and streets having width less than 3.05 mt.( Also not to used over footpaths). (CSR Item No. = 14.137)
Providing and laying 60 mm thick factory made cement concrete interlocking Paving blocks of M- 35 grade manufactured by block making machine equipped with steel mould clamped to a strong vibratory table with hydraulic pressure for compaction of concrete as per IRC SP 63 -2014 and of approved size and design / shape laid in Ordinary Grey Colour and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in- Charge. (CSR Item No. = 14.138)
Dismantling brick work tile masonary or tile lining. B) in cement (CSR Item No. = 8.5 (b))
Stripping and stacking iron sheets of a roof including ridging, flashing, eaves boards gutters and down pipes. (CSR Item No. = 8.11)
Scraping (e) Bricks dismantled from brick work in lime or cement. (CSR Item No. = 8.31 (e))
Carriage of Bricks lead 1 km including loading & unloading. (CSR Item No. = 5.2 (vi) & 4.3)
Carriage of Bricks Bats lead 1 km including loading & unloading (CSR Item No. = 5.2 (i) & 4.1 A)
Civil Item (Non-Schedule Items)
Providing & fixing in position MS or heavy flat iron clamps made out of MS flat iron of the approved design for fixing UPVC pipes to walls compete in all respects (MR)
Providing and fixing Anti-skid floor tiles 10mm thick 300x300mm (fully vitrified) in flooring skirting ;and dado in 12.5mm thick cement plaster 1:3 in base and jointed with white cement slurry @ 3.3 kg/sqm in joints including corners angles and beading. (NS)
Providing & Fixing of Soft Fiber Acoustical Suspended Ceiling System – of approved make acoustik soft Fiber Glass micro look/Square edge tile with 15mm Exposed Groove Grid. The tiles should have Humidity Resistance (RH) of 95%, NRC 0.90, Light Reflectance >84% with Fire Resistance in module size of 595 X 595 X 15 mm. The grid should 15mm grid sections i.e. the Main Runner 3000mm in 38 mm web height, 1200 mm & 600 mm Cross Tees in web height of 26mm with thickness 0.3mm, to comprise main runner spaced at 1200mm centre securely fixed to the structural soffit using suspension system at 1200mm maximum centre. The First/Last suspension system at the end of each main runner should not be greater than 450mm from the adjacent wall. Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm centre to form 1200 x 600 mm module. Cut cross tees longer than 600mm require independent support. 600 x 600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross tees. Perimeter trim to be wall angles of size 3000x19x19mm, secured to walls at 450 mm maximum centres and as per the drawing and the work complete in all respects to the satisfaction of Engineer in-charge. All accessories consisting of Fasteners of thread size 6.5mm x 25/5 with Soffit Cleat made of Galvanized steel of size 27 x 37 x 25 x 1.6mm and Level Clip in dimensions of 85x30x0.8mm with 4.00 mm GI wire. (MR)
Providing & fixing of Wooden Slats Wall paneling Dexune /Pro Acoustic / Veils Dexi wood grooved panel having shall be fire resistance (FR) BS476 Part 7 with melamine laminate panel 2440mm x128mmx15mm with 2mm grooved at 14mm pitch, Tongue and grove adages for seamless mounting having density of 800 kg/m3 (based panel confirming to IS 12406 and laminated panel confirming to IS 114587) The black of the panels are perforated with a nonwoven fabric covering of 0.2 mm for providing Sound absorption via the acoustic impedance method. Dexune panel ids fixed by using GI Framework spaced at 600mm centres @ aluminium framework spaced at 400mm centres with suitable brackets or wood batten to maintain line length & level and the system is backline with 50 mm Roxul Rockwool and along with all accessories. Installation wooden battens (provided by others) of section 50mmx50mm or as approved by the Architect on the solid wall horizontally using screws and plugs at spacing of 600 mm centre-to- centre. Screw the aluminium extruded keel for channeled woodworks provided by manufacture over the lowest and second wooden batten at an on- centre distance of 600mm. Install the first set of wooden panels by inserting the clips for border channelled woodworks and insert the groove of the panel into the projecting flange of the aluminium clip. Continue installing rows of panels by inserting the tongue into the groove of the earlier inserted panel and progressively installing clips for inside channelled woodwork into the next keel till the actual height is achieved. Use clips for border channeled woodworks to finish off the installation. Finish off the edges using wooden moulding of matching colour complete in all respect as per instructions/Approval of the Engineer –in charge. (NS)
Providing & fixing Acoustic/Veils Stretch Fabric System with Acoustic panel solution having 25mm to 30 mm thickness on G.I studs 2400mm x 50mm web, flanges 15 & 50mm fully knurled giving it high strength, hot dipped galvanized steel with 120 GSM zinc coating specially designed for Acoustic vibration management and long life with a backing 50mm thick insulation. 600x1200x15mm wood tile NRC 1.00 to be mechanically fastened on the G.I studs. Then 12mm/20mm vinyl tracks are screw fixed on the 10mm ply and Acoustics panels Then the fabric is stretched over the Vinyl tracks. The installed system should provide NRC of 1.00. Fabric colour as per Architect choice-Ref attached specifications for more details. To be installed on GI studes 600x600 mm centre to centre 2400x50mm web thickness 0.5 mm, flanges 15 & 50mm fully knurled giving it high strength, hot dipped galvanized steel with 120 GSM zinc coating specially designed for Acoustic vibration management and long life with a backing 50mm thick,1000 GSM rock wool tested as per fire retardant ASTMD 635-1991/Insulation and IS 15061-2002 for excellent results. complete in all respect as per instructions/Approval of the Engineer –in charge. (NS)
Providing & fixing Wooden conference table for 32 seats 710 mm (Depth) and 750 mm (Height) in U-shape made of 3/4" commercial board/ply board mica. All edges covered with wooden teak beading duly spirit polished complete in all respect as per instructions/ Approval of the Engineer –in charge. (MR)
Providing & fixing Revolving Chair high back with heavy duty pedestal & wheels complete in all respect as per instructions/Approval of the Engineer –in charge. (MR)
Providing & fixing Vistor side writing Chair with cousiand complete in all respect as per instructions/Approval of the Engineer –in charge. (MR)
Extra for frosting glass pan in door, window and clearstory complete in all respect as per instructions/ Approval of the Engineer –in charge. (MR)
Water Supply (Schedule Items)
Excavation manually in trenches with straight or open cutting in built up street/lane having wall to wall width of straight/ lane upto 30.0 meter, for intramural sullage drains, extramural intercepting drains and outfall drains, storm water channels and other work contingent or incident thereto , to full dimensions and depth as shown on the drawings or as shall be required by engineer- in – charge including dressing to correct sections and dimensions according to templates and levels, dewatering of rain water, diversion of traffic, providing and fixing and maintenance of caution boards, fencing, night signals, for leads upto 15 m and for all the lifts and subsequent refilling, watering and dressing upto ground level, including removal of surplus spoil from the site upto 15meter distance complete in all respect a) For all classes of soil except rocky. (CSR Item No. = 29.1 A (a))
Cement concrete 1:5:10 (b) with stone aggregate 40 mm gauge (ii) mixing by mechanical means using concrete mixer volumetric type (CSR Item No. = 10.9 (b) ii)
Providing, lowering, cutting & jointing salt glazed stone ware pipes and specials ISI marked as per IS: 651-2007 class 5p-1 into trenches for all depths and laying out the same to correct alignment, gradients, levels etc. cutting of concrete beds joints holes, supporting the pipes and specials in correct position in a suitable rigid manner while the same are being jointed and until the supporting benching, hunching and envelopes are completed including jointing of pipes and specials in trenches, using cement sand mortar 1:1 and best spun jute yarn as per IS:1887, finishing and trowelling of each joint at an angle of 45 degree with the longitudinal axes of pipe watering, keeping the joint covered and wetted till the same are curd testing the sewerage line of leakage and defects good as laid in the contract specification and chipping and finish the cut surface to uniform finish to the entire satisfaction of engineer-in-charge Including all cartage etc complete in all respects. b) 150mm i/d pipe (CSR Item No. = 29.41 (b))
Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. (B) Single Socket Type B (b) 110mm o/d SWR UPVC pipe lines laid complete (CSR Item No. = 30.74 (iii) B (b))
Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. (B) Single Socket Type B d) 75mm o/d SWR UPVC pipe lines laid complete (CSR Item No. = 30.74 (iii) B (d))
Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. 110 mm dia pipe VI vent cowel (CSR Item No. = 30.81 (iii) B (vi))
Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. Elbow 90 Degree (All side socketed ) (CSR Item No. = 30.81 (iii) B (v))
Providing PVC solvent cement joints to SWR Pipes and specials including cost of PVC solvent cement and tools etc of approved make (to the approval of Engineer-in-charge) (b) 110mm o/d (CSR Item No. = 30.77 C (b))
Providing PVC solvent cement joints to SWR Pipes and specials including cost of PVC solvent cement and tools etc of approved make (to the approval of Engineer-in-charge) (d) 75mm o/d (CSR Item No. = 30.77 C (d))
Providing and fixing H.C.I. Floor traps conforming to I.S.I. Specification of reputed firm of the self cleaning design with S.S. grating with frame with or without vent arm and including cement concrete 1:2:4 under and around the floor trap where required upto floor level complete in all respects including cutting and making good the walls and floors, etc. (b) With 100mm x 75mm i/d Floor Trap (weighing 5.8 Kg) (CSR Item No. = 30.79 (b))
Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm. (b) 100mm internal Diametre H.C.I. gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm (CSR Item No. = 30.99 (b))
Providing, laying, jointing , fixing and testing ISI marked G.I. pipe (as per IS 1239) B-class premium make such (Jindal Hisar) including cost of specials (such as tees, bends, sockets, elbows etc.) painting with anti-corrosive bitumastic paint, testing, cutting, threading inside building complete. a) 15 mm i/d (CSR Item No. = 28.35 (a))
Providing, laying, jointing , fixing and testing ISI marked G.I. pipe (as per IS 1239) B-class premium make such (Jindal Hisar) including cost of specials (such as tees, bends, sockets, elbows etc.) painting with anti-corrosive bitumastic paint, testing, cutting, threading inside building complete. (b) 20 mm i/d (CSR Item No. = 28.35 (b))
Providing, laying, jointing , fixing and testing ISI marked G.I. pipe (as per IS 1239) B-class premium make such (Jindal Hisar) including cost of specials such as tees, bends, sockets, elbows etc. cutting, threading and testing in trenches in the ground complete . b) 20 mm i/d (CSR Item No. = 28.36 (b))
Providing, fixing and jointing G.I. Union couplings (of approval make with the approval EIC) as per IS 1879 in G.I. pipe lines complete in all respect. a) 15 mm i/d G.I Union (CSR Item No. = 28.40 (a))
Providing, fixing and jointing G.I. Union couplings (of approval make with the approval EIC) as per IS 1879 in G.I. pipe lines complete in all respect. b) 20 mm i/d G.I Union (CSR Item No. = 28.40 (b))
Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I. pipes line and making good the same to its original condition. a) Size 75mmx75mm (CSR Item No. = 30.85 (a))
Cutting holes upto 23 cm square through B.B. in cement walls or stone masonry wall in cement for pipes, and making good the same & finishing according to existing finish where required.(L/R) b) Through wall 22.86 cm thick (CSR Item No. = 28.56 (b))
Providing and placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer-in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fittings and base support for tank. i) Triple layer Tanks (CSR Item No. = 30.97-A (i))
Providing and fixing in position automatic brass ball cock in tanks. b) Brass Ball cock with rod and Plastic i) 15 mm i/d (CSR Item No. = 30.96 (b) (i))
Providing and placing in position G.I. Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC water storage tanks complete in all respect. a) G.I. tank nipple 15mm i/d (CSR Item No. = 30.98 (a))
Providing, fixing and jointing Brass Ball valves screwed with SS/BRASS ball & spindle & Teflon seats, on G.I. pipe lines including all carriages complete. a) 15 mm i/d Brass Ball valves (CSR Item No. = 28.44 (a))
Providing and fixing in position M.S. or heavy flat iron clamps made out of M.S. flat iron not less than 5mm of the approved design for fixing C.I. soil waste, vent or antisyphonage pipes to walls complete in all respect. Including cutting and making good the walls and floors etc. and painting.(a) M.S. holder bats clamps for 100mm i/d H.C.I. pipes (CSR Item No. = 30.78 (a))
Providing & fixing 15mm i/dia bib cock of approved make to the approval of the EIC complete in all respect. i) CP Brass bib cock long nose/long body without flange (CSR Item No. = 30.65 A (i))
Providing and fixing in position stop cock/ Angle valve of approved make ( to the approval of Engineer-in-charge) complete in all respect. b) C.P. brass 15mm Concealed stop cock with flange (CSR Item No. = 30.66 (b))
Providing and fixing in position stop cock/ Angle valve of approved make ( to the approval of Engineer-in-charge) complete in all respect. b) C.P. brass 15mm Concealed stop cock without flange (CSR Item No. = 30.66 ( c))
Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect. ii) Size 550mmx400mmx815mm (CSR Item No. = 30.32 (ii))
Providing and fixing vitreous chinaware standard pedestal of approved make (to the approval of Engineer-in-charge) for wash hand basin complete in all respect. (i) Vitreous chinaware standard white pedestal for wash hand basin. (CSR Item No. = 30.43 (i))
Providing and fixing PVC waste pipe 32mm complete in all respect. (CSR Item No. = 30.20)
Providing and fixing in position vitreous Chinaware white Senso urinal size 37 x 39 x 61 cm of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass Urinal waste Coupling dome type 32mm outer length 75 mm complete in all respect. (CSR Item No. = 30.17 A)
Providing and fixing in position Chinaware Floor Mounted One Piece EWC type with matching chinaware cistern 10 ltr. Capacity. (without cistern fitting) with P trap or S trap of approved make (to the approval of the Engineer-in-charge) and seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. (a) Chinaware Floor Mounted One Piece EWC type with matching chinaware cistern 10 ltr. Capacity (without cistern fitting) size 62x37x67 cm with P trap or S trap and seat cover complete in all respect. (CSR Item No. = 30.3 (a))
Providing and fixing stainless steel health faucet complete in all respect. (CSR Item No. = 30.24)
Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge) fixed into wall with rawl plugs and C.P. brass screws complete in all respect. (CSR Item No. = 30.60)
Providing and fixing in position 5mm thick beveled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with crawl plugs 50mm, C.P. brass screws and washer and S/S studs on top complete in all respect (as required by the Engineer-in-charge) (a) Size 600mmx450mm (CSR Item No. = 30.61 (a))
Providing and fixing in position towel rail/ ring of approved make (to the approval of Engineer-in-charge) fixed in with crawl plugs embedded in walls with brass screws complete in all respect. (b) C.P. towel ring (CSR Item No. = 30.58 (b))
Providing and fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge) complete in all resprct. ( e) PVC tube connection of size 15 mm x 450 mm with PTMT nut (CSR Item No. = 30.72 (e))
Providing and fixing in position S.S. grating with frame of approved make (to the approval of Engineer-in-charge) complete in all respect. (CSR Item No. = 30.80)
Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design. (b) 450mm x 600mm inside with 455mm x 610mm cover and frame light duty double seal (CSR Item No. = 29.60 (b))
Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:2 (1 cement : 2 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete. (a) For pipes 100 to 250 mm Diametre (CSR Item No. = 29.65 (a))
Water Supply (Non –Schedule Items)
Providing and fixing malleable iron holder bats (NS)
ELECTICAL ITEMS (Schedule Items)
RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- a) Wiring fan point (Without fan box) (CSR Item No. = 34.02 (i) (a))
RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- (b) Wiring light point (CSR Item No. = 34.02(ii))
RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- (d) Wiring 3 pin 6 Amp. wall socket (CSR Item No. = 34.02 (iv))
RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½" deep for walls and CI 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):- (f) Wiring 3 pin 16/20 amp. power plug control point (CSR Item No. = 34.02(vi))
PVC INSULATED SINGLE CORE FRLS COPPER CONDUCTOR CABLE:- Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- (ii) Overall size 1.5sq.mm (Un-sheathed) (CSR Item No. = 34.09 (ii))
PVC INSULATED SINGLE CORE FRLS COPPER CONDUCTOR CABLE:- Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- Overall size 2.5sq.mm (Un-sheathed) (CSR Item No. = 34.09 (iii))
PVC INSULATED SINGLE CORE FRLS COPPER CONDUCTOR CABLE:- Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- Overall size 4sq.mm (Un-sheathed) (CSR Item No. = 34.09 (iv))
XLPE/ PVC INSULATED UN-ARMOURED CABLES (ON SURFACE):Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:- (xxii) Overall size 25sq.mm (3½ Core) Unarmoured (On-Surface) (CSR Item No. = 34.10 C (xxii))
COPPER EARTHING: 8 SWG COPPER EARTHING : Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:-(a) Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 4.50 metre (14.76 feet) below ground level (up to 8metre in Length) with G.I. pipe 20mm dia. (A-class), 3 metre long (CSR Item No. = 34.14 (i) a)
SHEET METAL Double Door Distribution Board for MCBS/RCBO/RCCB’s: Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers / RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-TP&N Horizontal Double Door Distribution Board 8 way each (CSR Item No. = 34.17 (vii))
SHEET METAL IRON CLAD SWITCHES: Supply and erection of sheet metal Iron Clad Switches on existing surface with G.I. bolts & nuts/ rag bolts and nuts etc., according to the size of holes in the body of the enclosure including connections with suitable size of thimbles and bonding to the existing earth as Per PWD General Specifications:- (vii) ICTPN Switch 100amp., 415volts (CSR Item No. = 34.18 (vii))
MINIATURE CIRCUIT BREAKERS/ RCBO's/ RCCB's: MINIATURE CIRCUIT BREAKERS: Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- (ii) MCB Single Pole 6-32amp. (10kA, Curve-C) (CSR Item No. = 34.16 A (ii))
PVC, HDPE PIPES & PVC FLEXIBLE PIPES:- Supply & erection of PVC conduit pipes (ISI marked) as per IS 9537:PART III & HDPE pipes (fire retardant) for wiring purposes including bends, inspection boxes etc., where necessary including other petty material as per PWD General Specifications 2010:- Heavy gauge PVC conduit pipe 25mm dia. (ISI marked 2mm thick) Heavy Gauge PVC Conduit Pipe 25mm dia. (On Surface) (CSR Item No. = 34.12 (ii))
Electrical Items (Non-Schedule Items)
Providing & Fixing Exaust Fan 10'' Heavy duty complete in all respect as per instructions/ Approval of the Engineer –in charge. (MR)
Providing & Fixing Exaust Fan 15'' Heavy duty complete in all respect as per instructions/ Approval of the Engineer –in charge. (MR)
Providing & Fixing LED Light-36 W (2'x2') complete in all respect as per instructions/ Approval of the Engineer –in charge. (MR)
Providing & Fixing 1.8 tons Inverter Split Air Conditioners (4 star) complete in all respect as per instructions/Approval of the Engineer –in charge. (MR)
Providing & Fixing Stablizer for AC (120 v- 280 v) complete in all respect as per instructions /Approval of the Engineer –in charge. (MR)
Providing & Fixing Conference Mics and speaker system complete in all respect as per instructions/Approval of the Engineer –in charge. A) CMD-4200 Delegate Unit HSN:8518 (MR)
Providing & Fixing Conference Mics and speaker system complete in all respect as per instructions/Approval of the Engineer –in charge. B) CMC-4100 HSN: 8518 (MR)
Providing & Fixing Conference Mics and speaker system complete in all respect as per instructions/Approval of the Engineer –in charge. C) CMA-4400 Conformance Amplifier HSN:8518 (MR)
Providing & Fixing Conference Mics and speaker system complete in all respect as per instructions/Approval of the Engineer –in charge. D) SMX-902T Speaker HSN: 8518 (MR)
Providing & Fixing Conference Mics and speaker system complete in all respect as per instructions/Approval of the Engineer –in charge. E) TZA-7000DP 700 WATTS with built-in digital player 2 Zone PA Mixer Amplifier HSN:8543 (MR)
Providing and fixing Wall fan complete in all respect as per instructions/ Approval of the Engineer –in charge. (MR)
Providing and fixing LED Tube light 36W complete in all respect as per instructions/ Approval of the Engineer –in charge. (MR)
Bidder Name
Amount in Words
SUBASH CHAND
THE GAG CO OP L AND C SOCIETY
SUDHIR ANAND
SUBASH CHAND
THE GAG CO OP L AND C SOCIETY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .