Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.9 LAccepted-AOC | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹52.9 L+₹1.7 L (3.23%)Rejected-Finance GANDHI PARK ROAD TINSUKIA ASSAM PIN 786125 | TINSUKIA | ASSAM | 786125 | L2 | Rejected-Finance Higher bid value | |
| 3 | L3₹53.2 L+₹2.0 L (3.93%)Rejected-Finance P O WEST SRIPURIA DIST TINSUKIA ASSAM PIN 786 145 | TINSUKIA | ASSAM | 786145 | L3 | Rejected-Finance Higher bid value | |
| 4 | L4₹54.0 L+₹2.8 L (5.42%)Rejected-Finance | L4 | Rejected-Finance Higher bid value | |
| 5 | L5₹54.4 L+₹3.1 L (6.10%)Rejected-Finance | L5 | Rejected-Finance Higher bid value |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
15 Oct 2022, 6:00 pmClosed
GE DINJAN
GE DINJAN, PANITOLA (PO), DIBRUGARH (DIST), ASSAM
SPECIAL REPAIR REPLACEMENT OF WATER SUPPLY PIPE LINE AT SECTOR C AND SPECIAL REPAIR TO BLDG NO P-34 AND P-38 OF MH AND CERTAIN MINOR WORKS UNDER GE DINIAN
2022_MES_554008_1
C/8485/E8
Open Tender
Civil Works
Item Rate
180 days
DINJAN MIL STN
AS PER TENDER DOCUMENT
10 documents required · 10 mandatory
₹500
GE DINJAN
₹94,000
Yes
22 Nov 2022
23 Sept 2022
17 Oct 2022
23 Sept 2022
15 Oct 2022
8 Oct 2022
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m deep for foundtion etc ( for taking out and laying pipe etc.) and not exceeding 10 Sqm in plan and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm complete all as specified and as directed.
Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
M&L for hardcore of brocken bricks or boulder, of gauge not exceeding 63 mm, deposited, spread, and leveled in layers not exceeding 15 cm thick, watered and rolled / rammed to a true surfaces complete all as specified and as directed.
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
M&L for PCC (1:4:8) type D2 (using 40 mm graded aggregate) as in foundation, filling and mass concrete complete all as specified and as directed.
M&L for precast cement concrete manhole cover, type B1 (1:2:4), (using 20mm graded stone aggregate) set in cement mortar (1:4) complete all as specified and as directed.
M&L for RCC (design mix), type M-25, (20 mm graded agg) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
M&L for RCC (design mix), type M-25, (20 mm graded agg) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
M&L for RCC (design mix), type M-25, (20 mm graded agg) in column, pillar, piers, post and struts complete all as specified and as directed.
M&L for RCC (design mix), type M-25, (20 mm graded agg) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, and similar work complete all as specified and as directed.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions etc rough finished flat surface of concrete complete all as specified and as directed.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc rough finished flat surface of concrete complete all as specified and as directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200mm thick (horizontal or sloping) complete all as specified and as directed.
M&L for mild steel TMT bars 10 mm dia and over ,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed.
S&F for mild steel TMT bars 8mm dia and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and as directed.
S&F for mild steel TMT bars 8mm dia and over for stirrups, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Demolition of brickwork or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.
M&L for brick work with sub class ‘B’ bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar (1:6) complete all as specified and as directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and as directed.
M&L for rendering 15 mm thick on fair faces of external wall of brick work or stone surfaces in two layers (10 mm and 5 mm thick) in cement mortar (1:4) using water proofing compound in top layer and finished even and smooth without using extra cement complete all as specified and as directed. Note : Water proofing compound measured separately.
M&L for rendering 10 mm thick of internal wall on fair faces of brick work or concrete surfaces in cement mortar (1:6) and finished even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 10mm thick on fair faces of brick masonary or concrete surfaces in cement mortar (1:4) and finishes the surfaces even and fair without using extra cement complete all as specified and as directed.
M&L for rendering 5 mm thick on ceiling in cement mortar (1:3) finished even & smooth without using extra cement complete all as specified and as directed.
Supply only liquid water proofing compound complete all as specified and as directed.
M&L for 40 mm thick damp proof course to horizontal or vertical surface including necessary formwork in cement mortar (1:2:4) type B-0 complete all as specified and as directed.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including nainital or similar pattern roof coverings complete all as specified and as directed.
S&F for pre painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F for pre painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
S&F for joist, channel, angle, or tee sections of Fe 290 (Gde E-165) fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) complete all as specified and as directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and as directed.
M&L for anodised aluminium snap grid size 605 X 605 mm frame work for false ceiling complete all as specified and as directed.
S&F for hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and as directed.
M&L for 6 mm thick non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/aluminium framework with screws complete all as specified and as directed.
Taking down chowkhats or frames not exceeding 1.5 Sqm each (without taking off shutters from the frames) complete all as specified and as directed.
Taking down chowkhats or frames exceeding 1.5 Sqm but not exceeding 4 sqm each (without taking off shutters from the frames) complete all as specified and as directed.
S&F for pressed steel frames for doors local work shop made of size 125x60mm with one or more rebates using cold rolled commercial mild steel sheet of 1.2mm thick including providing and fixing necessary lugs, 100mm butt hinges, hold fast, lock strike plate, shock absorber etc and including PCC filling of hollow section using plain cement concrete (1:3:6) type C1 complete all as specified and as directed.
S&F for pressed steel frames for doors local work shop made of size 105x60mm with one or more rebates using cold rolled commercial mild steel sheet of 1.2mm thick including providing and fixing necessary lugs, 100mm butt hinges, hold fast, lock strike plate, shock absorber etc and including PCC filling of hollow section using plain cement concrete (1:3:6) type C1 complete all as specified and as directed.
S&F for 35 mm thick second class hardwood plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and as directed.
S&F for 35mm thick, glazed and skelton shutters with second class hard wood, open rebated and prepared to receive glass, gauge, etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass/gauge etc, sizes of members of shutter as specified in SSR Part I Section 8, clause 8.24 (a) complete all as specified and as directed.
S&F in repairs galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and as directed.
S&F for factory made Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing in SSR Part II 2020 complete all as specified and as directed.
S&F for factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing in SSR Part II 2020 complete all as specified and as directed.
S&F for 100 mm long butt hinges, medium weight, cold rolled mild steel fixed to chowkats complete all as specified and as directed.
S&F for aluminium handle 150 mm long cast type, anodised extruded fabricated type complete all as specified and as directed.
S&F for aluminium anodised barrel tower bolts of extruded section 150 mm long complete all as specified and as directed.
S&F for 300 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and as directed.
S&F for 375 mm mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and as directed.
M&L for 18/19mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work and fixed with wooden beading complete all as specified and as directed.
S&F for 3 mm thick sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
M&L for PCC (1:2:4) type B0 (using 12.5 mm graded aggregate) as in hold fast and filling of steel chowkhat etc. complete all as specified and as directed.
S&F for mild steel flat iron as in hold fast 25x6 mm confirming to Fe 290 (Gde E-165) complete all as specified and as directed.
M&L for preparation of new or untreated surfaces of wooden surface of any description, not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
M&L for painting steel and iron surfaces of steel surfaces of any description, over 10cm in width or girth, not otherwise described, applying two coats of synthetic enamel paint over coat of red oxide primer including preparation of new surface complete all as specified and as directed.
S&F for mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe 290 (Gde-E-165) complete all as specified and as directed.
M&L for preparing newly plastered surfaces of walls, etc and applying three coats of white wash complete all as specified and as directed.
M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of walls and applying two coats of distemper-oil-emulsion over a coat of primer including 3 mm thick wall care putty complete all as specified and as directed.
M&L for preparing old decorated surfaces of walls by complete removal of existing treatment and applying two coats of distemper-oil-emulsion over a coat of primer including 2 mm thick wall care putty complete all as specified and as directed.
M&L for preparation of old decorated plastered surfaces of walls by brooming down or steel wire brushing, scraping down with steel scraper, smoke soot, moulds moss and efflorescent salts, trading oil and greasy spots and applying one coat of white wash complete all as specified and as directed.
M&L for preparation of old decorated plastered surfaces of ceiling by brooming down or steel wire brushing, scraping down with steel scraper, smoke soot, moulds moss and efflorescent salts, trading oil and greasy spots and applying one coat of white wash complete all as specified and as directed.
M&L for preparation of new plastered surface of walls etc and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and as directed.
Demolition of unreinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness (below or above ground level) complete all as specified and as directed.
M&L for 75 mm thick, plain cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) as in plinth protection, footpath, etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand (1:2) making impressions of expanded metal whilst the concrete is green complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
M&L for non-skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed or bedding layer of cement mortar (1:6) for laying floor finishes complete all as specified and as directed.
M&L for non-skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed or bedding layer of cement mortar (1:6) for laying floor finishes complete all as specified and as directed.
M&L for coloured glazed ceramic tiles in vertical surface of size 450X 350X 7 mm thick over 10 mm thick backing coat of cement mortar (1:4) set and jointed in neat cement slurry and pointed in white or colour cement to match over complete all as specified and as directed.
M&L for light shade vitrified ceramic tiles 10 mm thick (Square/rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed in cement mortar (1:6) complete all as specified and as directed.
M&L for light shade vitrified ceramic tiles 10 mm thick (Square.rectangular) polished, area of each tiles exceeding 0.36 sqm but not exceeding 0.42 sqm, in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10 mm thick backing coat in cement mortar (1:4) complete all as specified and as directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and as directed.
M&L for machine cut kota stone slab flooring 20-25 mm thick laid over 15 mm thick screed bed or bedding layer of cement mortar (1:6) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
M&L for machine cut kota stone slab 20-25 mm thick in riser of steps, skirting, dado and pillar laid over 10 mm thick back coat of cement mortar (1:4) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
M&L for 20 mm thick granite (of any type) work (table rubbled and polished) in steps, Jambs, Pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over 15 mm screed complete all as specified and as directed.
M&L for chequered cement concrete tiles 20cmX20cmX25mm thick, , as in floors etc, including 15 mm thick screed bed or bedding in cement mortar (1:6) and set and jointed in neat cement slurry and pointed in grey cement and pigments to match with the shade of tiles complete all as specified and as directed.
M&L for 100 mm thick Cement concrete type D-2, (1:4:8) (40mm graded aggregate) in sub base of floor etc complete all as specified and as directed.
M&L for 40mm thick PCC, type B0, (1:2:4), (using 12.5mm graded broken stone aggregate) as in sub base of surface finished even and smooth without using extra cement complete all as specified and as directed.
S&F for 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.
S&F in repairs110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.
S&F in repairs 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and as directed
S&F for 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed
S&F in repairs 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed.
S&F in repairs 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and as directed.
S&F for 110 mm bore PVC (SWR) junction single, (Single T) equal or unequal complete complete all as specified and as directed.
S&F for 75mm bore PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and as directed.
S&F for 110 mm bore PVC (SWR) bends any radius complete all as specified and as directed.
S&F for 75 mm bore PVC (SWR) bends any radius complete all as specified and as directed.
Taking up or down 15 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed.
Taking up or down 20 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed.
Supply and laying of 16mm of CPVC pipes SDR 11& Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors, trenches complete all as specified and as directed.
Supply and laying of 20mm of CPVC pipes SDR 11& Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors ,tranches complete all as specified and as directed.
Supply and laying of 25mm of CPVC pipes SDR 11& Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors ,tranches complete all as specified and as directed.
S&F for 16mm dia CPVC Brass thread elbow complete all as specified and as directed.
S&F for 20mm dia CPVC Brass thread elbow complete all as specified and as directed.
S&F for 25mm dia CPVC Brass thread elbow complete all as specified and as directed.
S&F for 16mm dia CPVC Brass thread Tee complete all as specified and as directed.
S&F for 20mm dia CPVC Brass thread Tee complete all as specified and as directed.
S&F for 25mm dia CPVC Brass thread Tee complete all as specified and as directed.
S&F for 16mm CPVC Brass thread union complete all as specified and as directed.
S&F for 20mm CPVC Brass thread union complete all as specified and as directed.
S&F for 25mm CPVC Brass thread union complete all as specified and as directed.
S&F for 16mm CPVC ball valve complete all as specified and as directed.
S&F for 20mm CPVC ball valve complete all as specified and as directed.
S&F for 25mm CPVC ball valve complete all as specified and as directed.
S&F for 25mm CPVC tank adopter complete all as specified and as directed.
Dismantling of water tank capacity exceeding 500 not exceeding 1000 Ltrs and removing to store complete all as specified and as directed.
S&F for rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of capacity 1000 ltrs hoisted and fixed in position specified in SSR Part I complete all as specified and as directed.
S&F for 20 mm bore, ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and as directed.
S&F for 20 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed.
M&L for cutting chases, pinning in brickwalls, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth complete all as specified and as directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed
S&F in repairs Harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc. complete all as specified and as directed.
S&F in repairs white vitreous china squatting pan Orissa pattern of size 580mm x 440 mm white, with integral foot rests connected with 'P' or 'S' trap and flushing pipe and taking out old WC & connections complete all as specified and as directed.
S&F in repair vitreous china wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) complete all as specified and as directed.
S&F for plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and as directed.
S&F in repairs PVC low level flushing cistern 10 litre capacity, valveless, symphonic action type with inlet, ball valve, float and handle incl bracket, PVC conection pipe and flush pipe of polyethylene of low or high density or PVC. 32 mm dia complete all as specified and as directed.
S&F in repairs vitreous china wash hand basin white flat back size 550x400mm excluding taps, waste chain and plug and porcelain stopper including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe complete all as specified and as directed.
S&F in repairs for PVC connections 15mm size with PTMT nuts of length 600 mm complete all as specified and as directed.
S&F in repairs 32 mm Waste coupling of PTMT (half or full threaded) (Minimum weight 32mm?45gms/40mm-60 gms)complete all as specified and as directed.
M&L for PVC (SWR) floor trap 75mm dia, plain with grating including jointing with solvent cement including disconnection of old existing trap, and connected with existing water pipe complete all as specified and as directed.
S&F for grating doom 100mm dia of PTMT (Minimum weight 25gms) complete all as specified and directed.
S&F for PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and as directed.
S&F for tubular towel rail, 20mm dia, D type, 60cm long Brass Chromium plated between flanges complete all as specified and as directed.
S&F in repairs soap dish vitreous china coloured approximate size (160mmx160mmx90mm) complete all as specified and as directed.
S&F in repair brass chromium plated shower rose 125 mm size fixing to steel pipe or union complete all as specified and as directed.
S&F in repairs for bib taps fancy type CP with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferule and fixed of size 15mm bore in repair complete all as specified and as directed.
S&F in repairs 15 mm bore dia cast copper alloy fancy type, chromium plated stop valves, crewed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
S&F in repairs 15mm stop valves (concealed type), cast copper alloy fancy type chromium plated, long sunk and cup, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
S&F in repair pillar taps of size 15mm, chromium plated fancy type cast copper alloy, with capstan heads, screwed down high pressure, with or without lettered 'Hot' or cold with long screwed shanks and fly nuts screwed for iron pipe complete all as specified and as directed.
S&F for anodised aluminium windows/ventilator sliding shutter, three track way type without sash bars, alumimium sections weighing 0.55 Kg/m including necessary joining cleats, glass clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings, such as peg stays, 150mm long (1 No) hinges type B-21, 100mm long (2 Nos) suitable handle, with complete accessories including glass, wire mesh, anodised aluminium frame (chowkhat) complete all as specified and as directed.
S&F in repairs 32mm brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed complete all as specified and as directed.
S&F for vitreous china bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), (excluding flushing cistern, flush pipe and waste pipe) including providing and fixing plugs, bedding urinal against wall in cement mortar (1:2), securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and union for discharge pipe (exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and as directed.
S&F for Jet spray universal complete all as specified and as directed.
S&F in repair health faucet cast copper alloy with push button & 1m long flexible steel pipe with PVC lining suitable for 15mm bore pipe complete all as specified and directed.
S&F 15mm dia Parryware (Cat Part No G1807A1) angle stop cock with wall flange complete all as specified and as directed.
S&F for Parryware corner shelf (Cat Part No T6010A1) complete all as specified and as directed.
S&F for PVC waste pipe of 32 mm size flexible and 1.2 mtr long, fitted to basin or sink complete all as specified and as directed.
S&F for new magnum parryware urinal port (combo set) size 590x400, Cat Part No. C0583 including spreader complete all as specified and as directed.
S&F for parryware urinal dome waste coupling Cat Part No (T-9954A1) complete all as specified and directed.
S&F for designer curtain rail with fixing Brackets all as specified complete all as specified and as directed.
M&L for preparation newly or old decorated external surfaces of wall, chajja, facia etc by complete removing old paints by hand scrubber without disturbing the plastered surfaces broomed to remove all dust, dirt and all loose scales of old paints and other foregin matter and applying one coats of water based acrylic weather proof exterior emulsion (Apex ultima superior quality) paint complete all as specified and as directed.
M&L for water proofing treatment on RCC roof etc. comprising with the following operation & as specified herein below:- (a) Taking down existing old tarfelt, bituminous compound, cement mortar including cleaning & removing debris to a distance exc 100 m n.exc.250m. (b) M&L 25 thick cement concrete type B0 1:2:4 (12.5 mm graded aggregate). (c) M&L for 15 mm thick cement mortar with WPC in 1:4 over PCC when concrete is green. (d) Preparing & cleaning of fully dried cement plastered surface. (e) Applying one coat of cold bituminous primer to the plastered surface @ 0.25 litres per sqm conforming IS-3384. (g) A layer of APP based polymeric membrane membrane 3mm thick (minimum) weighing 3.5 kg per sqm reinforced with polyster non woven fabric (weighing not less than 160 gms/sqm) shall be applied over bituminous primer as specified above. Application of polymeric membrane shall be by torch application. The over lap shall be minimum 100 mm on transverse direction and 75 mm in longitudinal direction. (f) One coat of aluminium paint over APP membrane @0.11Kg/Sqm. Note : Prior to execution of the APP Membrane works, leak proof test shall be done by ponding water on roof slab to minimum depth of 25 mm. The entire roof slab shall be flooded with water for 48 hours. The necessary barrier shall be made to make feasible to stagnate water for 48 hours on roof slab.
Taking down carefully unserviceable aluminium/copper point wiring (light, fan, socket or power) complete, (fitting such as switches, ceiling roses, pendants, regulators, sockets, etc to be measured separately), removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed.
M&L for concealed point wiring complete with 1.5 sqmm FRLSH, PVC insulated multi stranded copper conductor single core cable 1100 volts grade, drawn into non metallic PVC rigid conduit medium grade of 20mm dia and conduit accessories and fittings like bend, elbows, crosses wall crossing etc. including cutting, chasing and pinning fixed on wall, floor, roof and including provision of PVC insulated FRLS 1.5 sqmm copper conductor for earth continuity and connected to common earth dolly and modular metal flush boxes concealed in wall and modular cover plate with frame for housing the switches socket outlet, fan regulator etc, including testing on completion for one light/ fan point/ bell buzzer point controlled by one way 6 Amp modular switch complete all as specified and as directed. Note : Cost of PVC conduit, cover plate and box of suitable module, cutting chases of wall, making good disturbed wall surfaces including finishing with cement mortar (1:4), matching with existing colour/paint of surface are deemed to be included in the quoted rate.
All as per item No 149 above but for one 3 pin socket outlet, 5 Amps on Independent board.
All as per item No 149 above but for one 5 Amps, 3/5 pin socket outlet on the same board with other switches.
All as per item No. 149 above but wiring with cables of size 2.5 sqmm & cables of size 2.5 sqmm as continuous earth wire for one 3 pin socket outlet, 5/15 Amps on Independent board complete all as specified and as directed.
S&F for switch piano, 5 Amp single pole, flush type one way 230 volts bearing ISI marked complete all as specified and as directed.
S&F for socket outlet, 2 in 1, 3 pin, 5 Amps, flush type bearing ISI marked complete all as specified and as directed.
S&F for switch socket combination, 2 in 1, 5 Amps, flush type, 240 volts bearing ISI marked complete all as specified and as directed.
S&F for switch socket combination, 2 in 1, 5/16 Amps, 240 volts, bearing ISI marked flush type complete all as specified and as directed.
S&F for ceiling rose, 3 phase/PVC/polycarbonate, isolated body bearing ISI marked and including PVC box complete all as specified and as directed.
S&F for stepped type(five steps) electronic fan regulator flush type complete all as specified and as directed. Make : Model No. 14502 of Anchor or equivalent.
S&F for bell push, 5 Amps, 240 volts, flush type complete all as specified and as directed.
S&F for call bell, AC, 230 volts, single pole complete all as specified and as directed.
S&F in repair lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.
S&F in repair LED bulb of 9 Watt complete all as specified and as directed. Make : Havells /Philips/Bajaj.
S&F in repair 20 Watt, surface and wall mounted LED Batten with polycarbonate housing and intigrated complete all as specified and as directed. Make : Cat No LTTB4F20WLEDEW BATTEN of C&S/ Philips/ Bajaj/ Havells.
S&F in repair decorative type city-1 wall light fittings made of polycarbonate suitable for 10/15 watt retrofit LED including LED 10 watt spiral B22 base complete all as specified and as directed.
S&F in repair sheet metal enclosure for MCB DB double door, single pole & neutral, 12 way, 240 Volt with common bus bar at incoming end, complete all as specified and as directed.
S&F for sheet metal enclosure for MCB DB double door, triple pole & neutral, 4 way, 240 Volt with common bus bar at incoming end, complete all as specified and as directed.
S&F for MCB, SPN, 6 to 32 Amps, 240 Volts, 'C' Series, breaking capacity 10KA complete all as specified and as directed.
S&F for MCB, single pole, 6 to 32 Amps, 240 Volts, 'C' Series, breaking capacity 10KA complete all as specified and as directed.
S&F for MCB, double pole, 6 to 32 Amps, 240 Volts, 'C' Series, breaking capacity 10KA complete all as specified and as directed.
Taking down unserviceable sub-main wiring up to 10 Sqmm with rigid steel conduits /PVC casing-caping including cutting chases for taking out conduits and making good disturbed surfaces complete all as specified and as directed.
M&L for sub main wiring with two run of 6 Sqmm (Nominal area) single core cable PVC insulated, multistranded, unsheathed, copper conductor cables (FRLSH), 1100 Volts grade drawn through PVC casing-caping/conduit of suitable size, fixed to wall/ceiling etc including one run of 6 Sqmm (nominal area) single core, PVC insulated, multistranded, unsheathed, copper conductor (FRLSH) as earth wire and duly connected to common earth point complete all as specified and as directed. Note : (a) PVC Casing-caping/conduit, two run wiring cables and one run of earth wire will be measured as one length (b) All incoming and outgoing cable shall be connected by using proper lugs & sockets)
M&L for concealed sub main wiring with two run of 4 Sqmm (nominal area) single core cable PVC insulated, multistranded, unsheathed, copper conductor cables (FRLSH), 1100 Volts grade drawn through PVC conduit of suitable size, fixed to wall/ceiling etc including one run of 4 Sqmm (nominal area) single core, PVC insulated, multistranded, unsheathed, copper conductor (FRLSH) as earth wire and duly connected to common earth point complete all as specified and as directed. Note : (a) PVC Casing-caping/conduit, two run wiring cables and one run of earth wire will be measured as one length (b) All incoming and outgoing cable shall be connected by using proper lugs & sockets)
S&F in repair PVC casing caping of size 20-25 mm complete all as specified and as directed.
Supply, installing, testing and commissioning of light duty metal anti dust exhaust fan, suitable for Single Phase AC supply, earthing etc, power input 31 W, 220/240 V, 380 mm sweep size, fan speed 900 RPM, 3 nos. blades, copper winding, Air delivery minimum 800 CMM and including all fixing accessories complete all as specified and as directed. Make : Model No Tarns Air 12" - reversible of Cropmpton/Bajaj/Khaitan/Havells/Orient.
S&F in repairs 25 Watt LED building security light new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING separate driver compartment with IP65 protection and impact resistance of IK07 complete all as specified and as directed.
Supply, Installation, testing & commissioning of heater water storage type electric geyser (vertical cylindrical type) 25 Litre capacity suitable for 240 volts, AC, single phase with BEE 5 star rating(minimum) and metallic/ABS body, porcelain enamel glass lined inner tank including fixing arrangement with providing including suitable capacity flexible cable 3 core 1.5 metre to 2 metre length and necessary connection, fixing on Walls with and including all necessary fitting material i.e. Mild Steel Bolts (Bolts to be grouted), Nuts, Washers etc. and surface finished with cement mortar (1:4) complete all as specified and as directed.
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to 4mm GI wire by means of bolts and nuts checknuts and washers protected by 20mm bore galvanised iron light grade pipe, funnel with 40mm bore GI medium grade pipe for watering, wire mesh including concrete pit PCC (1:3:6) type C1, precast RCC 1:2:4 type B1 cover slab of size 350x350x50mm reinforced with 8mm dia TMT steel bars @ 150 mm center to center in both direction and 10mm dia MS handle of suitable size, charcoal or coke and salt in alternative layers, including necessary excavation and earth work in any type of soil, all as specified and shown in electrical plate no 3 of SSR part-1 and tested on completion complete all as specified and as directed.
Supply laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with standard aluminium conductor of size 50 Sqmm 3.5 core and testing, including brass compression cable gland, terminal lug, etc complete all as specified and as directed.
Supply, laying and testing cable low tension UG XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6 Sqmm 2 core complete all as specified and as directed.
M&L for 15mm bore galvanised steel tubing (light grade), with all fittings laid in trenches, wall and floor etc complete all as specified and as directed.
M&L for sand cushioning (dry) in trenches for protection of UG cables (below, above and around the UG cable laid in trenches) of 23cm spread thick ness and consolidated (punned) upto 18cm thickness complete all as specified and as directed. Note : For the purpose of payment, punned thick-ness of sand cushioning only shall be measured and paid for.
S&F for sub-class B brick, well burnt, laid breadth-wise along the axis of cable laid in trenches over sand cushion laid for UG Cable protection complete all as specified and as directed.
Taking down carefully serviceble ceiling fan/ exhaust fan deposit in safe costody and refix it original position after minor repair complete all as specified and as directed.
Taking down carefully serviceble geyser any size and capacity deposit in safe custody and refix it after minor repair complete all as specified and as directed.
Taking down carefully serviceble energy meter deposit in safe custody and refix it after minor repair complete all as specified and as directed.
S&F for plug and socket type DB (Functional Unit) 20 Amps capacity with provision of single pole 20 amps MCB, plug top and earth plug, grouted flush to walls complete all as specified and as directed.
S&F in repairs PP-R gate valves of Size 40 mm outer dia (brass insert) connect to PP-R pipe complete all as specified and as directed.
S&F in repairs PP-R gate valves of Size 50 mm outer dia (brass insert) connect to PP-R pipe complete all as specified and as directed.
S&F in repairs CI venturimeter having size 100mm complete all as specified and as directed.
Taking up or down 100 mm bore galvanised steel tubing incl connections from trnches/wall/ floor/ceiling etc and keeping serviceable pipes in safe custody for reuse in the work complete all as specified and as directed. Note : Excavation and earth work shall be measured and paid separately under relevant item.
Taking up or down 80 mm bore galvanised steel tubing incl connections from trnches/wall/ floor/ceiling etc and keeping serviceable pipes in safe custody for reuse in the work complete all as specified and directed.complete all as specified and as directed. Note : Excavation and earth work shall be measured and paid separately under relevant item.
Taking up or down 50 mm bore galvanised steel tubing incl connections from trnches/wall/ floor/ceiling etc and keeping serviceable pipes in safe custody for reuse in the work complete all as specified and as directed. Note : Excavation and earth work shall be measured and paid separately under relevant item.
Taking up or down 40 mm bore galvanised steel tubing incl connections from trnches/wall/ floor/ceiling etc and keeping serviceable pipes in safe custody for reuse in the work complete all as specified and as directed. Note : Excavation and earth work shall be measured and paid separately under relevant item.
Supply, laying, connection, and testing, 100 mm bore, steel water tubing, galvanised, medium grade conforming to IS 1239 (Part-1): 2004 with all fittings conforming to IS 1239 (Part-2): 2011 & fixed to laid in trenches etc complete all as specified and as directed.
Supply, laying, connection, and testing, 80 mm bore, steel water tubing, galvanised, medium grade conforming to IS 1239 (Part-1): 2004 with all fittings conforming to IS 1239 (Part-2): 2011 & fixed to laid in trenches etc complete all as specified and as directed.
Supply, laying, connection, and testing,50 mm bore, steel water tubing, galvanised, medium grade conforming to IS 1239 (Part-1): 2004 with all fittings conforming to IS 1239 (Part-2): 2011 & fixed to laid in trenches etc complete all as specified and as directed.
Supply, laying, connection, and testing, 40 mm bore, steel water tubing, galvanised, medium grade conforming to IS 1239 (Part-1): 2004 with all fittings conforming to IS 1239 (Part-2): 2011 & fixed to laid in trenches etc complete all as specified and as directed.
Supply, laying, connection, and testing, 50 mm outer dia, 3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and as directed.
Supply, laying, connection, and testing, 63 mm outer dia, 3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and as directed.
Supply, laying, connection, and testing, 90 mm outer dia, 3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and as directed.
Supply, laying, connection, and testing, 110 mm outer dia, 3- layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches complete all as specified and as directed.
Taking up 200 mm bore cast iron pipe (including all fitting) with spigot and socket end and lead joints including burning out lead joint and recovering lead complete all as specified and as directed. Note : Excavation and earth work shall be measured and paid separately under relevant item.
All as per item No. 203 here-in - before but size 150mm bore.
All as per item No. 203 here-in - before but size 100mm bore.
All as per item No. 203 here-in - before but size 80mm bore.
Supply, laying, connection, and testing, 200 mm bore, ductile iron pressure pipe centrifugally cast (spun) with spigot and socket ends, class K-7 and confirming to IS 8329- 2000 with push on rubber gasket jointing inside with cement mortar lining and outside zinc coating with finishing layer of back bitument / blue epoxy coating duly ISI marked in any length laid in trenches complete all as specified and as directed.
All as per item No.207 here-in - before but size 150mm bore.
All as per item No. 207 here-in - before but size 100mm bore.
All as per item No. 207 here-in - before but size 80mm bore.
Supply, laying, connection, and testing, 200 mm bore, ductile iron pressure pipe centrifugally cast (spun) with both ends flanged, class K-7 and confirming to IS 8329- 2000 with push on rubber gasket jointing inside with cement mortar lining and outside zinc coating with finishing layer of back bitument / blue epoxy coating duly ISI marked in length 5 meter (Each) laid in trenches complete all as specified and as directed.
All as per item No. 211 here-in - before but size 150mm bore.
S&F in repairs 200mm bore, cast iron sluice valve both ens flanged, class P-N 1.6 confirming to IS 14846 (raising stem type) with iron wheel head and stainless steel spindle including necessary jointing materials like nut, bolt, washers and rubber / fiber board gasket complete all as specified and as directed.
S&F in repairs 150mm bore, cast iron sluice valve both ens flanged, class P-N 1.6 confirming to IS 14846 (raising stem type) with iron wheel head and stainless steel spindle including necessary jointing materials like nut, bolt, washers and rubber / fiber board gasket complete all as specified and as directed.
S&F in repairs 100mm bore, cast iron sluice valve,both ens flanged, class P-N 1.6 confirming to IS 14846 (raising stem type) with iron wheel head and stainless steel spindle including necessary jointing materials like nut, bolt, washers and rubber / fiber board gasket complete all as specified and as directed.
S&F in repairs 80mm bore, cast iron sluice valve, both ens flanged, class P-N 1.6 confirming to IS 14846 (raising stem type) with iron wheel head and stainless steel spindle including necessary jointing materials like nut, bolt, washers and rubber / fiber board gasket complete all as specified and as directed.
S&F in repairs 150mm bore, cast iron butterfly valve, both ens flanged, class P-N 1.6 confirming to relavent IS lever operated including necessary jointing materials like nut, bolt, washers and rubber / fiber board gasket complete all as specified and as directed.
S&F in repairs 100mm bore, cast iron butterfly valve, both ens flanged, class P-N 1.6 confirming to relavent IS lever operated including necessary jointing materials like nut, bolt, washers and rubber / fiber board gasket complete all as specified and as directed.
S&F in repairs 100mm bore, cast iron non return (reflux) valve, flangedtype with by-pass arrangement suitable for 100mm dia water mains conforming to IS 5312 Part-1, class P-N 1.6 complete all as specified and as directed.
M&L in repair making connection of PP-R distribution branch with PP-R main of size 40mm outer dai by providing and fixing tee including cutting and making fusion joint etc. complete all as specified and as directed.
M&L in repair making connection of PP-R distribution branch with PP-R main of size 50mm to 90mm outer dai by providing and fixing tee including cutting and making fusion joint etc. complete all as specified and as directed.
M&L in repair making connection of PP-R distribution branch with PP-R main of size 110 mm outer dai by providing and fixing tee including cutting and making fusion joint etc. complete all as specified and as directed.
M&L in repair 40mm dia, stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
M&L in repair 50mm dia, stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
M&L for cast iron fittings for spigot and socketed pipe, such as bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. "Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs complete all as specified and as directed.
M&L for brick masonry valve pit of size 1.5cm x 1.5cm x 1.5cm (internal dimensions) including concrete work and construction of similar size valve pit with one brick thick wall in cement mortar (1:4) on 100mm thick PCC 1:4:8 type D2 (using 40mm graded broken stone aggregate) as in foundation lean concrete, including PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in benching and coping and 10mm thick rendering in cement mortar (1:4) internally and externally upto 15cm below ground level valve pit cover made out of 40x40x6mm angle iron frame all round fixed by means of 4 Nos holdfast 150mm long made out of flat iron 40x6mm embedded in PCC block (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) of size 230x200x100mm including hinges welded with angle iron frame and MS cover 3mm thck sheet, MS handle of suitable length and size welded with MS cover and suitable locking arrangement and applying two coats of synthetic enamel paint over a coat of red oxide primer including demolition of unserviceable/damaged valve pit complete all as specified and as directed.
M&L for preparation of old painted steel surfaces (horizontally or vertically 18 mtr height) and applying one coat of synthetic enamel paint any description over 10 cm in width or girth not otherwise described with colour as approved including temporary bamboo stagging arrangement as required complete all as specified and as directed.
M&L for plain cement concrete (1:3:6) type C-1 (using 20mm graded stone aggregate) in foundation of pipe supports/platform etc including necessary form work complete all as specified and as directed.
Burning out existing lead joint in position including removing old lead and keeping in safe custody for re-use for CI pipe 150 mm bore complete all as specified and as directed.
Burning out existing lead joint in position including removing old lead and keeping in safe custody for re-use for CI pipe 100 mm bore complete all as specified and as directed.
Burning out existing lead joint in position including removing old lead and keeping in safe custody for re-use for CI pipe 80 mm bore complete all as specified and directed. Note for item No. 230 to 232 : Excavation and earth work shall be measured and paid separately under relevant item.
M&L for run lead joint for CI spigot and socket pipes and fittings 150mm bore with new lead and other jointing materials complete all as specified and as directed.
M&L for run lead joint for CI spigot and socket pipes and fittings 100mm bore with new lead and other jointing materials complete all as specified and as directed.
M&L for run lead joint for CI spigot and socket pipes and fittings 80mm bore with new lead and other jointing materials complete all as specified and as directed.
Bimal Trading Company
Shree Trilok Electric Corporation
NChetia and Sons Trading
FREEZCON
M/s GANDHESWAR PHUKAN
STANDARD ELECTRIC WINDERS
MAZUMDAR ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .