| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹79.7 LAccepted-AOC RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L1 | Accepted-AOC QUOTED AMOUNT IS REASONABLE | |
| 2 | L2₹83.3 L+₹1.8 L (2.16%)Rejected-Finance B 87 SHAM NAGAR KHAYALA ROAD NEW DELHI 110018 | NEW DELHI | NEW DELHI | DELHI | 110018 | L2 | Rejected-Finance OTHER THAN LOWEST |
| Sl No | Description | Qty | Unit | RUCHIKA ENGG.WORKS L1 | New Era Engineers L2 |
|---|---|---|---|---|---|
| 1.00 | Comprehensive / Routine Maintenance of 02 Nos. Carrier Make Water-Cooled Chillers (Model: 30HXC190A, Capacity: 190 TR each, Sl. Nos: HJ1118 & HJ1116), AC Plant executed strictly through the OEM (M/s Carrier) including routine preventive inspections, 24/7 breakdown support, and the repair or replacement of all mechanical and electrical components including compressors, controls, and refrigerants to ensure peak operational efficiency following the successful completion of overhauling work all as specified and as directed. | 11 | Per Calender Month | 1,56,189 ₹17,18,079 Lowest | 1,75,000 ₹19,25,000 |
| 2.00 | Comprehensive / Routine Maintenance of 01 No. Bluestar Make Water-Cooled Chillers (LCW1-210V082525 Make:- Blue Star , Ser No VF08 AR1220281M3 ) , AC Plant including routine preventive inspections, 24/7 breakdown support, and the repair or replacement of all mechanical and electrical components including compressors, controls, and refrigerants to ensure peak operational efficiency following the successful completion of overhauling work all as specified and as directed. | 11 | Per Calender Month | 74,272 ₹8,16,992 Lowest | 85,000 ₹9,35,000 |
| 3.00Note for item no 1 & 2 -: (i) Water and Electric required for operation of plant shall be provided free of cost by the Department. (ii) After handing over of plant to contractor . Contractor shall fully responsible for satifactory performance of plant parameters during complete duration of contract period. During Comphensive maintance period any type of fault ( Major & Minor ) occurs in chiller plant contractor shall attend and rectify it without cost . No payment is admisible in this account to contractor. (iii) Contractor shall procure and provide all day to day consumable items such as refrigent gas and grease, sensors, electrical and electronic cards, control and power wirings, lugs sundry items etc reqired for operation of chiller AC plant shall be provided by contractor at his own cost . The quoated rate also include the periodical descaling of condenser coil , chemical cleaning of cooling tower fins and filters as per OEM recommendations and direction of GE during the period of defect liability . The cost of the same shall be deemed included in the unit rates quoted by the contractor. (iv) Contractor should produce MOU of agreement between OEM (carrier and Blue Star) & contractor firm from Whom contractor should carry out the comprehensive maintenance of compressor for 11 months time after completion of overhauling work. The After due varification from OEM chiller plant shall be handed over to contractor for comprehensive maintenance for 11 months. (v) In case contractor fails to attend fault within 24 hr after intimation by the department , he shall be liable to bear the recovery @ Rs 1500 /- per Hr and department shall rectify the fault through other agency on contractor risk and cost and amount shall be recovered from contractor dues. (vi) Tradesman will take all preventive measures as per code of practice of EI Rules and the Department will not be responsible for any type of untowards incident. (vii) Contractors shall provide all kind hand tools,tester, test lamp without any extra cost as per OEM recommendations. | |||||
| 4.00 | M&L for taking out Condenser Motor 25HP Capacity 720 rpm 3 phase 415 volt , opening the motor, cutting & removing old and burnt winding wire, rewinding the motor With new super enameled copper winding of suitable size including bearing insulating materials, varnishing, drying, replacement of both driven end , non driven end bearings and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed by engineer in charge. Note: The quoated rates must include loading & unloading with to and fro transportation for workshop and vice versa | 2 | Each Job | 24,000 ₹48,000 Lowest | 25,000 ₹50,000 |
| 5.00 | M&L for taking out Chiller Plant Primary & Secondry Motor 20 HP Capacity 720 rpm 3 phase 415 volt , opening the motor, cutting & removing old and burnt winding wire, rewinding the motor with new super enameled copper winding of suitable size including bearing insulating materials, varnishing, drying, replacement of both driven end,non driven end bearings and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed by engineer in charge. Note: The quoated rates must include loading & unloading with to and fro transportation for workshop and vice versa | 3 | Each Job | 21,000 ₹63,000 | 20,000 ₹60,000 Lowest |
| 6.00 | Material and Labour for dismantling of existing Air Handling Unit of any capacity upto 32000 CFM , cleaning, servicing, overhauling to all component of AHU, with and including cleaning of heating & cooling coil with caustic soda solution, including welding / brazing, wherever required to arrest leakages, cleaning of Pre-Micro Filters, replacing of vertical GI sheet supports, complete replacement of foam insulation of best quality using adhesive substance to avoid cold air leakages, fabrication of bottom GI tray of existing size with drain pane made out of 16 guage thick GI Sheets duly painted with bituminous paint over interior surface of tray, re-assembling all the dismantled components to its original position using new nut, bolt, washer and other packing material etc, with and including testing, commissioning of Air handling Unit at optimum efficiency, complete all as directed by Engineer -in-charge. | 13 | Each Job | 5,000 ₹65,000 | 4,000 ₹52,000 Lowest |
| 7.00 | S&F in repair AHU fan belt of Size B-82 complete as specified and directed by Engineer-in-charge. | 5 | Each Job | 482 ₹2,410 Lowest | 590 ₹2,950 |
| 8.00 | S&F in repair AHU fan belt of Size B-101 complete as specified and directed by Engineer-in-charge. | 8 | Each Job | 698 ₹5,584 Lowest | 700 ₹5,600 |
| 9.00 | S&F in repair AHU fan belt of Size B-116 complete as specified and directed by Engineer-in-charge. | 3 | Each Job | 821 ₹2,463 Lowest | 850 ₹2,550 |
| 10.00 | S&F in repair AHU fan belt of Size B-124 complete as specified and directed by Engineer-in-charge. | 5 | Each Job | 865 ₹4,325 Lowest | 865 ₹4,325 Lowest |
Tender Value
₹75.0 L
EMD Value
₹1.4 L
Closing Date
19 Jun 2026, 6:00 pmClosed
CWE DELHI CANTT
HQ CWE DELHI CANTT 110010
COMPREHENSIVE MAINT OF CENTRAL AC PLANT AIR HANDLING UNIT REPAIR OF COOLING TOWER PUMPS BODY PARTS PIPE LINE AND DUCTING AND COMPREHENSIVE MAINT OF DG SET INSTALLED AT CGDA AND CENTRAD EXTERNAL LIGHTING AND OTHER MISC E AND M WORK AT CGDA HQ AND CENT
2026_MES_767042_1
CWE/D-114/2025-26
Open Tender
Civil Works
Item Rate
330 days
DELHI CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE EAST DELHI CANTT
₹1.4 L
Yes
13 Aug 2026
22 May 2026
20 Jun 2026
22 May 2026
19 Jun 2026
12 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Comprehensive / Routine Maintenance of 02 Nos. Carrier Make Water-Cooled Chillers (Model: 30HXC190A, Capacity: 190 TR each, Sl. Nos: HJ1118 & HJ1116), AC Plant executed strictly through the OEM (M/s Carrier) including routine preventive inspections, 24/7 breakdown support, and the repair or replacement of all mechanical and electrical components including compressors, controls, and refrigerants to ensure peak operational efficiency following the successful completion of overhauling work all as specified and as directed. | 11 | Per Calender Month | - | - |
| 2 | Comprehensive / Routine Maintenance of 01 No. Bluestar Make Water-Cooled Chillers (LCW1-210V082525 Make:- Blue Star , Ser No VF08 AR1220281M3 ) , AC Plant including routine preventive inspections, 24/7 breakdown support, and the repair or replacement of all mechanical and electrical components including compressors, controls, and refrigerants to ensure peak operational efficiency following the successful completion of overhauling work all as specified and as directed. | 11 | Per Calender Month | - | - |
| 4 | M&L for taking out Condenser Motor 25HP Capacity 720 rpm 3 phase 415 volt , opening the motor, cutting & removing old and burnt winding wire, rewinding the motor With new super enameled copper winding of suitable size including bearing insulating materials, varnishing, drying, replacement of both driven end , non driven end bearings and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed by engineer in charge. Note: The quoated rates must include loading & unloading with to and fro transportation for workshop and vice versa | 2 | Each Job | - | - |
| 5 | M&L for taking out Chiller Plant Primary & Secondry Motor 20 HP Capacity 720 rpm 3 phase 415 volt , opening the motor, cutting & removing old and burnt winding wire, rewinding the motor with new super enameled copper winding of suitable size including bearing insulating materials, varnishing, drying, replacement of both driven end,non driven end bearings and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed by engineer in charge. Note: The quoated rates must include loading & unloading with to and fro transportation for workshop and vice versa | 3 | Each Job | - | - |
| 6 | Material and Labour for dismantling of existing Air Handling Unit of any capacity upto 32000 CFM , cleaning, servicing, overhauling to all component of AHU, with and including cleaning of heating & cooling coil with caustic soda solution, including welding / brazing, wherever required to arrest leakages, cleaning of Pre-Micro Filters, replacing of vertical GI sheet supports, complete replacement of foam insulation of best quality using adhesive substance to avoid cold air leakages, fabrication of bottom GI tray of existing size with drain pane made out of 16 guage thick GI Sheets duly painted with bituminous paint over interior surface of tray, re-assembling all the dismantled components to its original position using new nut, bolt, washer and other packing material etc, with and including testing, commissioning of Air handling Unit at optimum efficiency, complete all as directed by Engineer -in-charge. | 13 | Each Job | - | - |
| 7 | S&F in repair AHU fan belt of Size B-82 complete as specified and directed by Engineer-in-charge. | 5 | Each Job | - | - |
| 8 | S&F in repair AHU fan belt of Size B-101 complete as specified and directed by Engineer-in-charge. | 8 | Each Job | - | - |
| 9 | S&F in repair AHU fan belt of Size B-116 complete as specified and directed by Engineer-in-charge. | 3 | Each Job | - | - |
| 10 | S&F in repair AHU fan belt of Size B-124 complete as specified and directed by Engineer-in-charge. | 5 | Each Job | - | - |
| 11 | S&F in repair AHU fan belt of Size B-138 complete as specified and directed by Engineer-in-charge. | 5 | Each Job | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.55 MB
TENDERDOCUMENTSD114.pdf
Tender Documents • 2.31 MB
BOQ_859036.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .