| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.0 LAccepted-AOC NO 18 BHARATHI STREET WEST GANDHI NAGAR AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | L1 | Accepted-AOC aoc | |
| 2 | L2₹30.0 L+₹5.9 L (24.7%)Rejected-Finance KALIAPPA COMPLEX THRICHY ROAD RANGANATHAPURAM SULUR COIMBATORE 641 402 | COIMBATORE | COIMBATORE | TAMIL NADU | 641402 | L2 | Rejected-Finance L1 being accepted |
Tender Value
Refer Docs
EMD Value
₹63,000
Closing Date
12 Nov 2020, 6:00 pmClosed
CWE AF TRIVANDRUM
CWE AF TRIVANDRUM HQ SAC IAF COMPLEX AKKULAM THURUVIKKAL POST TRIVANDRUM 11
REPAIR MAINTENANCE TRANSFORMERS SWITCH GEARS 2 4 6 POLE STRUCTURE LT PANELS AND CONNECTED WORKS AT AF STN THANJAVUR.
2020_MES_386676_1
CWE(AF)/TVM/SUL/82323
Open Tender
Civil Works
Item Rate
270 days
Thanjavur
AS per NIT
7 documents required · 7 mandatory
₹500
GE AF Thanjavur
₹63,000
18 Dec 2020
15 Oct 2020
14 Nov 2020
15 Oct 2020
12 Nov 2020
29 Oct 2020
15 Oct 2020 - 22 Oct 2020
Amount
SCHEDULE 'A'
Supply, Laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured LT electric power under ground cables, heavy duty with aluminium conductor of cross sectional area 10 sqmm 2 core with all fixing & connecting accessories including taking down old unserviceable cable complete all as specified and directed.
All as per Item No 2 here-in-before but 16 sqmm 2 core complete all as specified and directed.
All as per Item No 2 here-in-before but 16 sqmm 4 core complete all as specified and directed.
All as per Item No 2 here-in-before but 35 sqmm 3.5 core complete all as specified and directed.
All as per Item No 2here-in-before but 50 sqmm 3.5 core complete all as specified and directed.
All as per Item No 2 here-in-before but 95 sqmm 3.5 core complete all as specified and directed.
All as per Item No2 here-in-before but 120 sqmm 3.5 core complete all as specified and directed.
All as per Item No 2 here-in-before but 150 sqmm 3.5 core complete all as specified and directed.
All as per Item No 2 here-in-before but 185 sqmm 3.5 core complete all as specified and directed.
All as per Item No 2 here-in-before but 240 sqmm 3.5 core complete all as specified and directed.
All as per Item No 2 here-in-before but 300 sqmm 3.5 core complete all as specified and directed.
All as per Item No 2 here-in-before but 400 sqmm 3.5 core complete all as specified and directed.
Note for item nos 2 to 13 : The rate quoted shall inclusive of required number of cable glands on each cable entry to the panel board.
Supply and lay in repair cable HT, XLPE insulated screended PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 11000 volts grade (earthed cable) with stranded aluminium conductor of size 120 sqmm 3 core all as directed. Note: (i) Necessary excavation & earth work and cable protection items shall be measured and paid seperately vide relevant items of this schedule. (ii)While laying the cable the site executive, Engineer-in-Charge and GE shall make sure that necessary testing prior to laying and after laying before energizing has been carried out and test cerificates from the manufacturers are obtained from the contractor and kept in record and shall be produced on demand to visiting Officers..
All as per Item No 15 here-in-before but 95 sqmm 3 core omplete all as specified and directed.
Supply and fixing/laying in repairs/replacement 100 mm bore, steel tubings galvanised, light grade with all fittings fixing along the electric line in trench or pole / wall for protection of cable complete all as specified and as directed.
Supply and fixing/laying in repairs/replacement 80 mm bore, steel tubings galvanised, light grade with all fittings fixing along the electric line in trench or pole / wall for protection of cable complete all as specified and as directed.
Supply and fixing/laying in repairs/replacement 50 mm bore, steel tubings galvanised, light grade with all fittings fixing along the electric line n trench or pole / wall for protection of cable complete all as specified and as directed.
Supply and fixing/laying in repairs/replacement 40 mm bore, steel tubings galvanised, light grade with all fittings fixing along the electric line in trench or pole / wall for protection of cable complete all as specified and as directed.
Material and labour in repairs/replacement of aluminium cable thimbles/line connector/pin terminal/ ring terminal/insulated ring terminal/fork type terminals/bi-metallic terminals etc of size 400 Sqmm UG Cable including complete connection and crimping complete all as specified and as directed..
Material and labour in repairs/replacement of aluminium cable thimbles/line connector/pin terminal/ ring terminal/insulated ring terminal/fork type terminals/bi-metallic terminals etc of size 300 Sqmm UG Cable including complete connection and crimping complete all as specified and as directed..
Material and labour in repairs/replacement of aluminium cable thimbles/line connector/pin terminal/ ring terminal/insulated ring terminal/fork type terminals/bi-metallic terminals etc of size 240 Sqmm UG Cable including complete connection and crimping complete all as specified and as directed..
Material and labour in repairs/replacement of aluminium cable thimbles/line connector/pin terminal/ ring terminal/insulated ring terminal/fork type terminals/bi-metallic terminals etc of size 185 Sqmm UG Cable including complete connection and crimping complete all as specified and as directed.. .
Material and labour in repairs/replacement of aluminium cable thimbles/line connector/pin terminal/ ring terminal/insulated ring terminal/fork type terminals/bi-metallic terminals etc of size 150 Sqmm UG Cable including complete connection and crimping complete all as specified and as directed.. .
Material and labour in repairs/replacement of aluminium cable thimbles/line connector/pin terminal/ ring terminal/insulated ring terminal/fork type terminals/bi-metallic terminals etc of size 120 Sqmm UG Cable including complete connection and crimping complete all as specified and as directed.. .
Material and labour in repairs/replacement of aluminium cable thimbles/line connector/pin terminal/ ring terminal/insulated ring terminal/fork type terminals/bi-metallic terminals etc of size 95 Sqmm UG Cable including complete connection and crimping complete all as specified and as directed.. .
Material and labour in repairs/replacement of aluminium cable thimbles/line connector/pin terminal/ ring terminal/insulated ring terminal/fork type terminals/bi-metallic terminals etc of size 95 Sqmm UG Cable including complete connection and crimping complete all as specified and as directed.. .
Material and labour in repairs/replacement of aluminium cable thimbles/line connector/pin terminal/ ring terminal/insulated ring terminal/fork type terminals/bi-metallic terminals etc of size 35 Sqmm UG Cable including complete connection and crimping complete all as specified and as directed.. .
Material and labour in repairs/replacement of aluminium cable thimbles/line connector/pin terminal/ ring terminal/insulated ring terminal/fork type terminals/bi-metallic terminals etc of size 25 Sqmm UG Cable including complete connection and crimping complete all as specified and as directed.. .
Material and labour in repairs/replacement of aluminium cable thimbles/line connector/pin terminal/ ring terminal/insulated ring terminal/fork type terminals/bi-metallic terminals etc of size 16 Sqmm UG Cable including complete connection and crimping complete all as specified and as directed.. .
Material and labour in repairs/replacement of aluminium cable thimbles/line connector/pin terminal/ ring terminal/insulated ring terminal/fork type terminals/bi-metallic terminals etc of size 10 Sqmm UG Cable including complete connection and crimping complete all as specified and as directed.. .
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft /loose soil complete all as specified and as directed.. . .
M& L for Cement concrete in foundations, and mass concrete type D2 1:4:8 using 40mm graded stone aggregate complete all as specified and as directed.. . .
M& L for Cement concrete in foundations, and mass concrete type C1 1:3:6 using 20mm graded stone aggregate complete all as specified and as directed.. . .
Excavation in trenches in soft/loose soil not exc. 1.5 metre wide and not exc. 1.5 metre in depth and getting out for taking up / laying under ground electric cable or for pole etc complete all as specified and as directed.
Excavation in trenches in soft/loose soil not exc. 1.5 metre wide and exc. 1.5 metre but not exc 3 m in depth and getting out for taking up / laying under ground electric cable or for pole etc complete all as specified and as directed.
Returning, filling in, including spreading levelling watering and well ramming in layers not exceeding 25 cms in depth in soft/loose soils complete all as specified and as directed.
Removing surplus soils to a distance not exceeding 50 mtr and depositing where directed at a level not exc. 1.5 mtr above the starting point all complete as specified and as directed.
Supply and laying Sand coarse dry as in cushioning of under ground electric cable in trenches, laid to a uniform thickness of 23 cm (15 cm under the cable & 8 cm over the cable) and gently punned down to 18 cm thickness all complete as specified and as directed.
Supply and laying Bricks, sub class 'B' old size bricks, laid flat dry with width of the bricks laid to the axis of the cable all complete as specified and as directed.
M & L for providing PCC 1:2:4 type B-1 with 20 mm graded aggregate as in, coping and finishing the surface even and smooth without using extra cement complete all as specified and as directed.
M & L for PCC 1:3:6 type C2 using 40mm graded aggregate as in foundation for stay set / Pole / feeder pillar lean concrete etc including fair finish even and fair to exposed surfaces without using extra cement complete all as specified and as directed.
Supply and erecting steel tubular pole complete with cast iron base plate, finial taper plug, nuts and screw as specified, type 410 SP-31, 9 Metre long including two coats of aluminium paint including dismantling of existing unserviceable pole including demolition of PCC work complete all as specified and as directed. Note:PCC and earthwork in foundation shall be measured and paid under respective item separately
Supply and erecting steel tubular pole complete with cast iron base plate, finial taper plug, nuts and screw as specified, type 410 SP-55, 11 Metre long including two coats of aluminium paint including dismantling of existing unserviceable pole including demolition of PCC work complete all as specified and as directed. Note:PCC and earthwork in foundation shall be measured and paid under respective item separately
S & F for cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape or size as directed inclusive of two coats of aluminium paint over a coat of red oxide primer after and including dismantling old unserviceable cross arm etc complete all as specified and as directed.
S & F aluminium conductor steel reinforced (ACSR) of any size stringing and jointing on poles including, binding wires, jointing sleeves, aluminium tap and PG clamp etc after and including taking out old unserviceable ACSR complete all as specified and as directed.
M & L for under ground high tension cable fault finding for exact location by using LT fault locating equipment and trace out the fault complete all as specified and directed Note :- The rate quoted by the contractor shall include the rate for earth work, cable jointing kit and necessary T&P etc.
M & L for under ground low tension cable fault finding for exact location by using LT fault locating equipment and trace out the fault complete all as specified and directed Note :- The rate quoted by the contractor shall include the rate for earth work, cable jointing kit and necessary T&P etc.
M&L cable jointing kit for 11 KV (earthed) grade cable for outdoor termination heat shrink type joint compelete with jointing material and accessories suitable for 3 core XLPE armoured conductor cable of size 95 Sqmm complete all as specified and directed.
M&L cable jointing kit for 11 KV (earthed) grade cable for outdoor termination heat shrink type joint compelete with jointing material and accessories suitable for 3 core XLPE armoured conductor cable of size 120 Sqmm to 185 Sqmm complete all as specified and directed.
M&L cable jointing kit for 11 KV (earthed) grade cable for Straightthrough heat shrink type joint compelete with jointing material and accessories suitable for 3 core XLPE armoured conductor cable of size 120 Sqmm to 185 Sqmm complete all as specified and directed.
Supply and fixing in repairs/replace Ultra heavy duty capacitors type box series - LTBCU of KVAR 5 to 15 440 volts complete all as specified and as directed by Engr In Charge.
Supply and fixing in repairs/replace Detuned reactors 440 volts 50 HZ AC supply of KVAR 5 with 7% aluminium reactor complete all as specified and as directed by Engr In Charge.
Supply and fixing in repairs/replace Detuned reactors 440 volts 50 HZ AC supply of KVAR 10 with 7% aluminium reactor complete all as specified and as directed by Engr In Charge.
Supply and fixing in repairs/replace Detuned reactors 440 volts 50 HZ AC supply of KVAR 15 with 7% aluminium reactor complete all as specified and as directed by Engr In Charge.
Supply and fixing in repairs/replace capacitor duty contactors suitable for 5 KVAR capacitor complete all as as per L&T cat part No - CS96127 complete all as specified and as directed by Engr In Charge.
Supply and fixing in repairs/replace capacitor duty contactors suitable for 10 KVAR capacitor complete all as per L&T cat part No - CS96156 complete all as specified and as directed by Engr In Charge.
Supply and fixing in repairs/replace capacitor duty contactors suitable for 15 KVAR capacitor complete all as per L&T cat part No - CS90019 complete all as specified and as directed by Engr In Charge.
Supply and laying in repairs/replacement for 10 sqmm one twin core flat or circular 1100 volt grade heavy duty cable insulated stranded aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed complete all as specified and directed.
Supply and fix cable route indicator made out of 15x15x6mm GI plate welded with 8 mm x 45cm long GI rod grouted in PCC block 1:2:4 type B1 using 20mm graded stone aggregate of size 15x15x10cm and writing the words 'LT cable' as directed with synthetic enamel paint of two coats over a coat of primer including excavation and earth work all as directed.
Supply and fix cable route indicator made out of 15x15x6mm GI plate welded with 8 mm x 45cm long GI rod grouted in PCC block 1:2:4 type B1 using 20mm graded stone aggregate of size 15x15x10cm and writing the words 'HT cable' as directed with synthetic enamel paint of two coats over a coat of primer including excavation and earth work all as directed.
Material and labour for painting to existing surfaces of HT/LT 11/9 mtr long steel tubular poles with 2 coats of aluminium paint over the existing surface including brackets clamps junction boxes etc including writing of pole number and painting to HT insulator RYB etc all as specified and as directed.
Material and labour Air break switch (GOD) Gang Operated Device horizontal / vertical type, tripple pole, mechanically operated, mounted on nine insulators and steel frame, with operating mechanism worked from ground level, with operating rod 25mm dia light grade GI pipe, suitabel for current rating upto 200 Amps, HT 11 KV including taking out old unserviceable one and connecting up complete with locking arrangement all as directed .
Material and labour in repairs lightening arrestors expulsion type complete with all fittings, transmission class discharge capacity 65 kilo amps suitable for 11000 volts complete all as specified and as directed by Engr In Charge.
Mateial and labour in repairs pin type, vitreous, white, brown or green insulator including one galvonised mild steel spindle, two galvonised iron washers and one galvonised iron nut, 150mm height, 150mm dia suitable for 11000 volts grade complete all as specified and as directed by Engr In Charge.
Mateial and labour in repairs shackle type, vitreous, white, brown or green insulator including one galvonised mild steel straps 38 x 5mm two galvonised iron washers and one galvonised iron bolts 20mm, 150mm height, 150mm dia, suitable for 11000 volts grade complete all as specified and as directed by Engr In Charge.
Dehydration including filtration of transformer oil on different locations by dehydration plant including testing of samples before and after dehydration and fiteration complete all as specified and directed the dielectric strength to be achieved 60 KV at 4 mm gap after complete dehydration complete all as specified and as directed by Engr In Charge..
M&L for cleaning of complete body of transformer of capacity 315 KVA and painting with two coat dark BS Gray painting & R, Y, B, Black, Green colour coding to insulators complete all as specified and directed
M&L for cleaning of complete body of transformer of capacity 250 KVA and painting with two coat dark BS Gray painting & R, Y, B, Black, Green colour coding to insulators complete all as specified and directed
M&L for cleaning of complete body of transformer of capacity 100/160 KVA and painting with two coat dark BS Gray painting & R, Y, B, Black, Green colour coding to insulators complete all as specified and directed
M&L for cleaning of complete body of transformer of capacity 200 KVA and painting with two coat dark BS Gray painting & R, Y, B, Black, Green colour coding to insulators complete all as specified and directed
Material and labour for filling in with new transformer oil for top up having low viscosity of approved make as per IS 355 of 1992 and di-electric strength 60 KV(after filtration) complete all as specified and directed by Engineer-in-Charge. Make : Savita/Castrol
Taking down old and UNSV transformer any capacity at different locations in the area of responsibility falls under GE (AF) Thanjavur from two pole structure/ foundation including disconnecting the LT/HT connection and shifting to workshop and getting back after repair and refixing the same at original location and connecting electrically and commissioning complete all as specified and directed.
M&L repairs/replacement of burnt defective HT/LT copper coil of different type capcity winding with superior quality enamelled copper winding wire/strips of approved of suitable size/guage and Nos of turns matching with the existing impendence and insulated including all allied materials such as cork sheets, fibre glass insulation/paper insulation cotton, empire tape and wooden, bolts, nuts and washer (Brass) soldering and other packing material etc required for entire winding of coils all as specified and directed by Engineer- in-Charge.
M&L repairs/replacement of HT bushing porcelain, vitreous with brass spindle, threaded with washers nuts, lock nut and rubber seal suitable for transformer of any make /type/capacity in repairs all as specified and directed by Engineer-in-Charge
M&L repairs/replacement of LT bushing porcelain, vitreous with brass spindle, threaded with washers nuts, lock nut and rubber seal suitable for transformer of any make /type/capacity in repairs all as specified and directed by Engineer-in-Charge
M&L Top gasket sheet made out of 2 mm thick cork sheet with suitable GI bolts, nuts, washers for top of transformer any capacity in repairs complete all as specified and directed
M&L Dehydrating breather assembly Aluminium/CI body of standard size filled with silica-gel for transformer of any capacity in repairs complete all as specified and directed
M&L Temperature gauge circular dia type of standard size for transformer of any capacity in repairs complete all as specified and directed
Taking down old and unserviceable VCB/Load braek switch any capacity at different locations in the area of responsibility falls under GE (AF) Thanjavur from foundation including disconnecting electrically and shifting to workshop and getting back after repair and refixing the same at original location and connecting electrically and commissioning complete all as specified and directed.
Supply and fix in repairs/replacement Tulip support 1250 amps Model HCA/HPA/ESH/VD4/VBF suitable for VCB/Load brak switch complete all as specified and as directed by Engr In Charge.
Supply and fix in repairs/replacement Tulip complete (15 Fingure) 1250 amps Model HCA/HPA/ESH/VD4/VBF suitable for VCB/Load brak switch complete all as specified and as directed by Engr In Charge.
Supply and fix in repairs/replacement Phase barrier 360 x 545 T=3mm Model HCA/HPA/ESH/VD4/VBF suitable for VCB/Load brak switch complete all as specified and as directed by Engr In Charge.
Supply and fix in repairs/replacement support insulator Model HCA/HPA/ESH/VD4/VBF suitable for VCB/Load brak switch complete all as specified and as directed by Engr In Charge.
Supply and fix in repairs/replacement close/trip coil 24 volt/30 volt/110 volt/220 volt DC Model HCA/HPA/ESH/VD4/VBF suitable for VCB/Load brak switch complete all as specified and as directed by Engr In Charge.
Supply and fix in repairs/replacement coil 24 volt/30 volt/110 volt/220 volt DC Model HCA/HPA/ESH/VD4/VBF suitable for VCB/Load break switch complete all as specified and as directed by Engr In Charge.
Supply and fix in repairs/replacement aux contact Model HCA/HPA/ESH/VD4/VBF suitable for VCB/Load brak switch complete all as specified and as directed by Engr In Charge.
Supply and fix in repairs/replacement Motor assembly 110 volt / 220 volt AC/DC Model HCA/HPA/ESH/VD4/VBF suitable for VCB/Load brak switch complete all as specified and as directed by Engr In Charge.
Supply and fix in repairs/replacement Micro switch with ball or without ball Model HCA/HPA/ESH/VD4/VBF suitable for VCB/Load brak switch complete all as specified and as directed by Engr In Charge.
Supply and fix in repairs/replacement anti pumping relay 110 volts AC/DC Model HCA/HPA/ESH/VD4/VBF suitable for VCB/Load brak switch complete all as specified and as directed by Engr In Charge.
Note for item nos 53 to 60, 76 to 78 & 83 to 92 : The make and model No. given against these items are indicative and any alteration/modification required to bring the item suit to normal service/functioning, the bidder has to make such arrangement without any extra cost.
Total of Schedule 'A'
SUPER COOL
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .