Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
Tender Value
₹50,000
EMD Value
₹1,000
Closing Date
29 Jan 2024, 12:00 pmClosed
Executive Engineer MHD, Srinagar
Executive Engineer MHD, Srinagar
Maintenance and repair of wall mount points by way of providing and fitting of Oxygen point, oxygen flow meter, Vacuum point and vacuum jar for ICU/Cardiology ward at Govt. SMHS Hospital, Srinagar.
2023_PWDJK_238384_3
MHDS/TS /2023-24/143/e-tendering dated28-11-2023
Open Tender
Repair and Maintenance Works
Item Wise
5 days
Govt SMHS Hospital
As detailed in NIT
4 documents required · 4 mandatory
₹50
Executive Engineer MHD SGR
₹1,000
31 Jan 2024
28 Nov 2023
29 Jan 2024
28 Nov 2023
29 Jan 2024
28 Nov 2023
Amount
Providing, fitting and testing of ward vacuum units (600 ml) complete with suction regulator and Compatible probe. The ward vacuum units of 600 ml capacity shall be designed for minimum servicing and high efficiency. The body shall house an ON/OFF knob, regulation knob, vacuum gauge graduated in mili bars. The jar of the vacuum unit shall be transparent made of polycarbonate, unbreakable to the temperature of 134 degree centigrade. The units shall be provided with fluid control trap (safety) fitted on the unit and shall automatically and efficiently shut off vacuum fully, preventing the transfer of liquid to the vacuum regulator, pipe line and pump. The vacuum units are to be fitted on walls with the help of brackets. The job shall be inclusive of high pressure vacuum pipe of length not less than 1metre/job.
Dismounting of old malfunctioned wall suction points, Providing,fitting and testing of self sealing valve assembly (front loaded double locking) including cover for suction supply. The valve shall be installed on the wall with its inlet connected to the copper tubing carrying suction pipe by means of brazing with silver electrode. The job includes providing and fitting of necessary copper fittings complete in all respects. The valve shall be non-interchangeable, self sealing, quick- connect gas outlet for Suction suitable for head wall units/Wall. The front fascia of valves shall be non interchangeable and Gas colour coded.
Providing, fitting and testing of new BPC oxygen flow meter with humidifier bottles connected to the self sealing valves of oxygen and compatible probe. BPC oxygen flow meter shall be offering the latest technical improvements for a precise measuring of the flow with +/-5% accuracy. The body of the flow meter shall be chrome plated Brass, graduated flow tubes and cover made of polycarbonate. The flow meters shall have adjustable flow by needle valve with micro metrical regulation. The flow meter shall be able to compensate back pressure and shall have a standard flow of 0-15 LPM. The inlet filter of flow meter shall be made of stainless steel wire net and is to be connected to the outlet of self sealing valve with humidifier bottles. This includes providing and fitting of necessary copper fittings complete in all respects.
Dismounting of the old malfunctioned wall oxygen points, Providing, fitting and testing of Oxygen self-sealing valve-assembly (front loaded double locking) including cover for oxygen supply. The valve shall be installed on the wall with its inlet connected to the copper tubing carrying oxygen by means of brazing with silver electrode. The job includes providing and fitting of necessary copper fittings complete in all respects. (The valve shall be non-interchangeable, self sealing, quick connect gas outlet for oxygen, suitable for head wall units. The front facia of valves shall be non interchangeable and Gas colour coded.
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .