| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.1 LAccepted-AOC 121004 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹32.0 L+₹3.5 L (12.4%)Rejected-Finance NO 6 A ANNASANDRAPALYA NEAR BIG MASJID BUILDING HAL VIMANAPURA POST BANGALORE 560017 | BENGALURU URBAN | KARNATAKA | 560017 | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹32.5 L+₹4.0 L (14.0%)Rejected-Finance | L3 | Rejected-Finance NOT BEING LOWEST | |
| 4 | L4₹32.9 L+₹4.4 L (15.3%)Rejected-Finance | L4 | Rejected-Finance NOT BEING LOWEST | |
| 5 | L5₹33.6 L+₹5.1 L (17.9%)Rejected-Finance 8 6TH CROSS MATHRU SHREE NILAYA OPP MAHARISHI RESIDENCE KAGGADASAPURA CV RAMAN NAGAR BANGALORE 560 093 | BENGALURU URBAN | KARNATAKA | 560093 | L5 | Rejected-Finance NOT BEING LOWEST |
| Sl No | Description | Qty | Unit | RAHUL ENTERPRISES L6 | Neptune Engineers and Builders L1 | SAPTHAGIRI CONSTRUCTIONS L7 | ARCHANA CONSTRUCTION CO L5 | Suneetha Engineers and Contractors L4 | ShaikPyarejanandsons L2 | Standard enterprises L8 | MAHESH CHIKKAIAH L3 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Receiving complaints from JE in-charge lodged by the user/occupants of electrification nature, rectification of the fault as per the complaint lodged by the user onward 433 V 3 ph 50 Hz in respect of main distribution board having switch board, fused, MCB distribution board in sheet metal enclosure, point wiring fixture for light /fan / bell / light or power sockets, metal clad plug socket complete repairs to the extent by removing connections from the system, removing faults in (surface / concealed) wiring / circuits, sunken boxes, junction boxes, main switches, MCBs/DBs any type of utility light fittings, lamp holders, AC, ceiling fan/exhaust fans and other connected fixtures of internal electrification including providing stores such as wires of appropriate size and conductor matching to existing one upto the light of 5 mtr, insulation tape, screws, nuts as per the site requirement to rectify the fault with regard to complaint lodged and refixing of fitting and fixture to their original position as dismantled complete all as directed at site to the entire satisfaction of Engineer -in- Charge. | 234 | EACH JOB | 4,300 ₹10,06,200 | 2,250 ₹5,26,500 Lowest | 3,165.89 ₹7,40,818.26 | 4,200 ₹9,82,800 | 3,500 ₹8,19,000 | 2,300 ₹5,38,200 | 3,447 ₹8,06,598 | 4,200 ₹9,82,800 |
| 1.01Details of Area : (a) DIBT Residential Area (b) MES Residential Area (c) DIBT Technical Area (d) MES Office (e) All MES installations under DIBT Campus NOTE FOR ITEM NO 1.00 :- (i) Services shall be provided for attending and completing complaints on same day on urgent basis by providing technician with safety gadgets, tools and necessary equipments as per govt norms and as directed by Engineer in Charge. (ii) The services provided under this item with necessary technicians(at least one Electrician and two helpers) during the period 0800 Hrs to 1700 Hrs with 1 hour lunch break on each day shall be measured as One Job for payment purpose. In case if services are not attended in any particular day / time penal recovery @ double the quoted rate will be effected from the contractor for that day. | |||||||||||
| 1.02(iii) The electrical spares will be paid separately under supply only items. (iii) Rate quoted shall include for dressing of loose hanging cables in the site as and when required. (iv) T&P like ladder upto 20 ft , 2.5 sq.mm multistranded copper wire upto 5m for testing, tester, cutting plier, nose plyer, insulation tapes of various colour, allen key sets, spanner tool sets, crimping tools, screw driver sets, test lamp, multimeter, hand gloves, drilling machine and hammer required for electrician shall be provided by the contractor. (v) The cost of providing additional labours to carry mobile type step ladders for repairs of street light is deemed to have been included in the rate quoted. (vi) Contractor shall provide the complaint register and complaint slip serially numbered in quadruplicate as per prescribed format available in the sub-division. The rate of such items are included in this items. (vii) Any complaint which is left out / unatten-dend 2 days by the electrician by any reasons the same to be communicated to the JE in charge / AGE E/M with proper justified reason duly countersigned by user / rep of user. | |||||||||||
| 1.03(viii) The technicians on duty should have proper uniform and contractor shall provide with all protective arrangement during the duties and required tools for maintenance. (ix) The staff / tradesman deployed by the contractor should be much familiar with the distribution system of DFRL Mysore Area. If the tradesmen are found / observed indulged in any misbehavior or illegal activities will be not allowed to continue to work in the premises. Further the contractor will be solely responsible for any loss or problem raised due to such situations. No claims / relief from department will be entertained in any circumstances. (x) The above quoted rate is inclusive of providing transport (at least one two wheeler) to the tradesman for prompt conveyance to the site. Further fuel required for the same needs to be provided by the contractor. The tradesmen needs to be equipped with at least one mobile connection each. | |||||||||||
| 1.04(xi). The labourers shall be provided with protective devices and shall wear them while working. In case any accident / injury / fatal or partial disability happened, the contractor shall be solely responsible for settling all claims / compensation. Department will have a right to recover any sum indicated / claimed by Labour Commissioner / Court directive. | |||||||||||
| 2.00 | Attending day to day petty power supply problem complaints for maintenance and repairs of electric supply upto three phase 50 Hz 433 V in DIBT Residential, technical area and MES Complex complete all as specified and directed by Engineer-in-Charge.
Nature of duties (works) to be attended: -
(i) Registering the complaints with JE E/M or rep of this sub-division as and when received either communicating by personally or by telephonically.
(ii) No supply power complaint as and when received to be attended within 15 min and further give a prompt feed back report to JE (E/M) within half - an- hour telephonically.
(iii) The problem needs to be rectified either temporarily / permanently within 02 Hours from the complaint been registered. | 60 | EACH JOB | 2,100 ₹1,26,000 | 1,230 ₹73,800 | 1,074.71 ₹64,482.6 Lowest | 4,200 ₹2,52,000 | 2,500 ₹1,50,000 | 15,000 ₹9,00,000 | 3,800 ₹2,28,000 | 2,100 ₹1,26,000 |
| 2.01NOTE FOR SL ITEM NO 2.00 : (i) Necessary Tools / T&P needs to be supplied by the contractor for carrying out the Job. (ii) Sufficient No of tradesmen needs to be supplied by the contractor. In this regard no extra amount can be claimed by the contractor under any circumstances. (iii) The supply problem needs to be rectified within 02 Hours from the complaints been registered excluding the general shift as catered under Sr.No 1 & job to be carried out 24 x 7 (including Sundays & Closed Holidays). failing this clause a penalty of Rs. 2000/- per complaint will be charged. In this proof of delay in prescribed format will be submitted by user and will be treated as final and binding. On receiving 03 such instances a penalty of 10% of Total CA amount will be levied. (iv) Measurement of this job shall be considered only in cases where the complaint is received after the completion of the general Shift as catered under Sr.No1 / Sundays/ Closed holidays. | |||||||||||
| 3.00Supply only following electrical fittings for replacing as per site requirement. | |||||||||||
| 3.01 | (a) LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete | 80 | EACH | 280 ₹22,400 | 530 ₹42,400 | 1,163.89 ₹93,111.2 | 300 ₹24,000 | 500 ₹40,000 | 300 ₹24,000 | 1,500 ₹1,20,000 | 250 ₹20,000 Lowest |
| 3.02 | (b) 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. | 80 | EACH | 790 ₹63,200 | 620 ₹49,600 | 1,119.3 ₹89,544 | 800 ₹64,000 | 700 ₹56,000 | 300 ₹24,000 Lowest | 1,050 ₹84,000 | 710 ₹56,800 |
Tender Value
₹45.8 L
EMD Value
₹91,680
Closing Date
29 Oct 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
LT COL CHANDRAKANT JOSHI
DRDO Complex, CV Raman Nagar PO, Bangalore 560 093
DAY TO DAY MAINTENANCE OF MISCELLANEOUS ELECTRICAL SERVICES THROUGH SERVICE CELL IN RESIDENTIAL AND TECH AREA AT DIBT MYSORE UNDER GE I R AND D EAST BANGALORE
2025_MES_733990_1
8655/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE I R AND D EAST BANGALORE
CLASS D CATEGORY b(i)
8 documents required · 8 mandatory
₹500
Yes
GE I R AND D EAST BANGALORE
₹91,680
Yes
3 Dec 2025
10 Oct 2025
5 Nov 2025
10 Oct 2025
29 Oct 2025
24 Oct 2025
10 Oct 2025 - 23 Oct 2025
Amount
Receiving complaints from JE in-charge lodged by the user/occupants of electrification nature, rectification of the fault as per the complaint lodged by the user onward 433 V 3 ph 50 Hz in respect of main distribution board having switch board, fused, MCB distribution board in sheet metal enclosure, point wiring fixture for light /fan / bell / light or power sockets, metal clad plug socket complete repairs to the extent by removing connections from the system, removing faults in (surface / concealed) wiring / circuits, sunken boxes, junction boxes, main switches, MCBs/DBs any type of utility light fittings, lamp holders, AC, ceiling fan/exhaust fans and other connected fixtures of internal electrification including providing stores such as wires of appropriate size and conductor matching to existing one upto the light of 5 mtr, insulation tape, screws, nuts as per the site requirement to rectify the fault with regard to complaint lodged and refixing of fitting and fixture to their original position as dismantled complete all as directed at site to the entire satisfaction of Engineer -in- Charge.
Details of Area : (a) DIBT Residential Area (b) MES Residential Area (c) DIBT Technical Area (d) MES Office (e) All MES installations under DIBT Campus NOTE FOR ITEM NO 1.00 :- (i) Services shall be provided for attending and completing complaints on same day on urgent basis by providing technician with safety gadgets, tools and necessary equipments as per govt norms and as directed by Engineer in Charge. (ii) The services provided under this item with necessary technicians(at least one Electrician and two helpers) during the period 0800 Hrs to 1700 Hrs with 1 hour lunch break on each day shall be measured as One Job for payment purpose. In case if services are not attended in any particular day / time penal recovery @ double the quoted rate will be effected from the contractor for that day.
(iii) The electrical spares will be paid separately under supply only items. (iii) Rate quoted shall include for dressing of loose hanging cables in the site as and when required. (iv) T&P like ladder upto 20 ft , 2.5 sq.mm multistranded copper wire upto 5m for testing, tester, cutting plier, nose plyer, insulation tapes of various colour, allen key sets, spanner tool sets, crimping tools, screw driver sets, test lamp, multimeter, hand gloves, drilling machine and hammer required for electrician shall be provided by the contractor. (v) The cost of providing additional labours to carry mobile type step ladders for repairs of street light is deemed to have been included in the rate quoted. (vi) Contractor shall provide the complaint register and complaint slip serially numbered in quadruplicate as per prescribed format available in the sub-division. The rate of such items are included in this items. (vii) Any complaint which is left out / unatten-dend 2 days by the electrician by any reasons the same to be communicated to the JE in charge / AGE E/M with proper justified reason duly countersigned by user / rep of user.
(viii) The technicians on duty should have proper uniform and contractor shall provide with all protective arrangement during the duties and required tools for maintenance. (ix) The staff / tradesman deployed by the contractor should be much familiar with the distribution system of DFRL Mysore Area. If the tradesmen are found / observed indulged in any misbehavior or illegal activities will be not allowed to continue to work in the premises. Further the contractor will be solely responsible for any loss or problem raised due to such situations. No claims / relief from department will be entertained in any circumstances. (x) The above quoted rate is inclusive of providing transport (at least one two wheeler) to the tradesman for prompt conveyance to the site. Further fuel required for the same needs to be provided by the contractor. The tradesmen needs to be equipped with at least one mobile connection each.
(xi). The labourers shall be provided with protective devices and shall wear them while working. In case any accident / injury / fatal or partial disability happened, the contractor shall be solely responsible for settling all claims / compensation. Department will have a right to recover any sum indicated / claimed by Labour Commissioner / Court directive.
Attending day to day petty power supply problem complaints for maintenance and repairs of electric supply upto three phase 50 Hz 433 V in DIBT Residential, technical area and MES Complex complete all as specified and directed by Engineer-in-Charge. Nature of duties (works) to be attended: - (i) Registering the complaints with JE E/M or rep of this sub-division as and when received either communicating by personally or by telephonically. (ii) No supply power complaint as and when received to be attended within 15 min and further give a prompt feed back report to JE (E/M) within half - an- hour telephonically. (iii) The problem needs to be rectified either temporarily / permanently within 02 Hours from the complaint been registered.
NOTE FOR SL ITEM NO 2.00 : (i) Necessary Tools / T&P needs to be supplied by the contractor for carrying out the Job. (ii) Sufficient No of tradesmen needs to be supplied by the contractor. In this regard no extra amount can be claimed by the contractor under any circumstances. (iii) The supply problem needs to be rectified within 02 Hours from the complaints been registered excluding the general shift as catered under Sr.No 1 & job to be carried out 24 x 7 (including Sundays & Closed Holidays). failing this clause a penalty of Rs. 2000/- per complaint will be charged. In this proof of delay in prescribed format will be submitted by user and will be treated as final and binding. On receiving 03 such instances a penalty of 10% of Total CA amount will be levied. (iv) Measurement of this job shall be considered only in cases where the complaint is received after the completion of the general Shift as catered under Sr.No1 / Sundays/ Closed holidays.
Supply only following electrical fittings for replacing as per site requirement.
(a) LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete
(b) 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
(c) LED T8, linear LED T8 mirror lite LED Patti Capacity 20 watt with extruded aluminium body PC diffuser and inbuilt driver(Batten suitable for LED T8 lamps).
(d) LED T8 tube rod with in built driver and efficacy of 100 lm/W.
(e) LED light fitting 1x9W/1x10 W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size.
(f) LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.
(g) LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC surface type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.
(h) LED luminaire 1 ft x 4 ft, 35/36 watt, 220 V AC recessed/surface type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.
(i) suspended linear in sleek design suitable for all commercial spaces of capacity 36 watts, 4 feet
(j) Post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete. NOTE : The Post top lantern needs to be of same make and model of existing in the site. If in any case not available new type of fittings will be accepted at the discretion of Accepting Officer only and the contractor is abide to follow at any circumstances
(k) Pressure die cast powder coated housing with PC diffuser. efficient high output LED with IP 65 protection LED bollard light complete all as directed and as specified. NOTE : The Bollard light needs to be of same make and model of existing in the site. If in any case not available new type of fittings will be accepted at the discreation of Accepting Officer only and the contractor is abide to follow at any circumstances
(l) Very high efficiency round highbay LED of capacity upto 80 W in PDC housing suitable for industrial application. The luminaire has efficacy upto 140 lm/W to reduce quantity/wattage thereby reducing operational cost. It has 10KV SPD & ingress protection of IP66 with additional safety chain.
(m)LED street light fitting 60 watt 230V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP 66 protection Efficacy > 110/120 LPW, and 10KV SPD complete all as specified and directed.
(n) LED flood light 250 watt 230 V AC made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 protection having 10KV SPD,and System Efficacy ≥ 110/120/135 LPW.
(o) LED Round / Square surface mounted LED panel of 18 watt consist of PDC aluminium housing and high translucent frosted plastic diffuser makes it a robust Luminaire & having Efficacy of 100 lm/W complete all as specified and as directed by Engineer-in-Charge.
Supply only the following miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete testing and commissioning etc as required
(a) SP 6A to 32A rating 240/415 V, 10KA 'C' curve.
(b) SPN 32 A rating 240/415 V, 10KA 'C' curve
(c) SPN 40A to 63 A rating 240/415 V, 10KA 'C' curve
(d) TP 25A to 63 A rating 240/415 V, 10KA 'C' curve
(e) TPN 16A to 32 A rating 240/415 V, 10KA 'C' curve
(f) TPN 40A to 100 A rating 240/415 V, 10KA 'C' curve
Supply only the following internal electrical items.
(a) 1 way 6A 230 Volts single pole modular type
(b) 1 way 16A 230 Volts single pole modular type
(c) 1 way 6A 230 Volts single pole piano switch flush type
(d) 1 way 16A piano 230 Volts single pole piano switch flush type
(c) 6A 230 Volts 2/3 Pin socket outlet modular type
(d) 6A/16A 230 Volts 2/3 Pin socket outlet modular type
(e) Socket outlet 2 in 1, 3 pin, 5A ,230 Volts, flush type
(f) Socket outlet 2 in 1, 3 pin, 5 and 15 amp 230 V flush type
(g) Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal (2/4 fixing hole)
(h) Switch socket combination 2 in 1, 5 A flush type(2/4 fixing hole)
(i) Bell push, flush type, 5 amp
(j) Modular Bell push 6A 1 module
(k) Buzzer, Ding Dong AC. 230 volts, single pole
(l) ceiling rose, PVC/Polycarbonate, isolated body.
(m) stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd
(n) plug top 3 pin 5 amps AC 230 volts.
(o) plug top 3 pin 15 Amps AC 230 volts.
Supply only terminal junction boxes of suitable ways, plastic / MS of thickness 2 mm size and breadth of not less than 50mm with suitable openings for conductor including fixing of cover plates / Hylem sheets complete all as directed NOTE : The rate is deemed to be inclusive of necessary masonry work as required on walls.
Removing the Exhaust Fan complete of any type and size after disconnecting the electrical wiring & cleaning it with cleaning solutions (like white vinegar or baking soda paste or warm water with dish soap solutions) and scrubbing it with stiff- bristled brush or a non - abrasive sponge to scrub the soaked parts and wire brush or steel wool for removal of grease / rust and refixing it to the original position after connecting the electrical wiring complete as directed by Engineer-in-Charge. NOTE :- (i) The cleaning and scrubbing will be done at the site only. (ii) The quoted rate deemed to be inclusive of dismantling the exhaust fan from the height upto 20 ft . (iii) The quoted rate deemed to be inclusive of replacement of nuts, bolts , washers if any required during the removing/ re-fixing of exhaust fans.
Supply and fix louvers with shutters of size 450 mm complete all as specified and directed by Engineer -in Charge.
Supply and fix louvers with shutters of size 600 mm complete all as specified and directed by Engineer -in Charge.
Supply only Hylam Sheet complete all as specified and as directed.
Supply only the following Cover Plates along with frames complete all as specified and as directed.
(a) 1M Plate
(b) 2M Plate
(c) 3M Plate
(d) 4M Plate
(e) 6M Plate
(f) 8M Plate
Supply only in replacement the following MCB DBs complete all as specified and as directed. NOTE : The rate is deemed to be inclusive of necessary Mason work as required on walls.
(a) 8 way SPN with 200 Amps rated busbar sheet metal enclosure (Factory made) double door type
(b) 4 way SPN with 200 amps rated bus bar sheet metal enclosure (Factory made) double door type
Supply only service wire 10 sq.mm 4 core copper conductor complete all as specified and as directed.
ShaikPyarejanandsons (BID ID -3467420)
MAHESH CHIKKAIAH (BID ID -3459853)
Suneetha Engineers and Contractors (BID ID -3462617)
ARCHANA CONSTRUCTION CO (BID ID -3462322)
RAHUL ENTERPRISES (BID ID -3459086)
SAPTHAGIRI CONSTRUCTIONS (BID ID -3462262)
Standard enterprises (BID ID -3460915)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
BOQ_822672.xls
BOQ • 2.27 MB
8655Tender.pdf
Tender Documents • 0.75 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .