Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹3.4 CrAdmitted-Finance | -27.52% | ₹3.4 Cr | L1 | Admitted-Finance |
| 2 | L2₹3.6 CrAdmitted-Finance | -21.75% | ₹3.6 Cr | L2 | Admitted-Finance |
| 3 | L3₹3.7 CrAdmitted-Finance | -21.10% | ₹3.7 Cr | L3 | Admitted-Finance |
| 4 | L4₹3.8 CrAdmitted-Finance | -18.33% | ₹3.8 Cr | L4 | Admitted-Finance |
| 5 | L5₹3.9 CrAdmitted-Finance | -16.20% | ₹3.9 Cr | L5 | Admitted-Finance |
Updated dates
Tender Value
₹4.7 Cr
EMD Value
₹9.3 L
Closing Date
25 Mar 2026, 4:00 pmClosed
SE PWD R and B KATHUA SAMBA CIRCLE KATHUA
SE PWD R and B KATHUA SAMBA CIRCLE KATHUA
Please refers to BOQ
2026_PWDJK_304996_1
e-NIT No.PWD/SE/KS/38 of 2025-26 Dated 28-02-2026
Open Tender
Civil Works - Roads
1080 days
KATHUA-BASOHLI
Please refers to NIT and SBD
4 documents required · 4 mandatory
₹6,000
SE PWD R and B KATHUA SAMBA CIRCLE KATHUA
₹9.3 L
SE PWD R and B KATHUA SAMBA CIRCLE KATHUA
3 Apr 2026
3 Mar 2026
27 Mar 2026
3 Mar 2026
25 Mar 2026
3 Mar 2026
18 Mar 2026
Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. a) All kinds of soil
Earthwork in excavation in all kinds of soil by mechanical means (Hydraulic excavator) in trenches for foundation, drains, pipes etc. (not exceeding 1.5m in width) and for shafts, wells, cesspits and the like not exceeding 10sqm on Plan, including dressing of sides and ramming of bottoms lift upto 1.5m, including getting out the excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 mtr.
Providing and laying cement concrete of specified grade including curing but excluding the cost of centering and shuttering. All work upto plinth level with: a) 1:5:10 (1 cement:5 coarse sand:10 graded stone aggregate 40mm nominal size).
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts,struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchors blocks, plain window sills, fillets etcupto floor V level, including curing but excluding the cost of centring, shuttering and finishing with. a) 1:5:10 (1 cement : 5 coarse sand : 10 graded brick aggregate 40 mm nominal size
Providing and laying cement concrete of specified grade including curing but excluding the cost of centering and shuttering. All work upto plinth level with: a) 1:3:6 (1 cement:3 coarse sand:6 graded stone aggregate 20mm nominal size)
Providing and laying damp-proof Course 50 mm thick with cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and curing complete
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in charge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable separately. a) All works upto plinth level
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in charge. Note: - Cement in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is content considered payable or recoverable separately. a) All works above plinth level upto floor V level
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level: a) Thermo-Mechanically Treated bars of grade Fe-500D or more.
Centering and shuttering including strutting propping etc. and removal of form work for:-
Foundations, footings, bases of columns etc. for mass concrete.
Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
Columns, pillars, piers, abutments, posts and struts.
Lintel, beams, plinth beams, girders, bressumers and cantilevers.
Suspended floors, roofs, landings, balconies and access platform.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.
Disposal of excavated earth by way of mechanical transport lead upto 10.00 km.
Supplying and filling in plinth with fine sand under floors including, watering, ramming, consolidating and dressing complete.
Brick work with common burnt clay (non modular) bricks of class designation 7.5 in foundation and plinth including curing in cement mortar 1:6 (1 cement:6 coarse sand).
Extra for brick work with common burnt clay bricks / cement concrete bricks in superstructure above plinth level upto floor five level.
Half brick masonry with common burnt clay (non-modular) bricks of class designation 7.5 in foundations and plinth including curing in : a)Cement mortar 1:4 ( 1 cement : 4 coarse sand)
Extra for half Brick masonry in superstructure above plinth level upto floor V level.
12mm cement plaster of mix. 1:6 (1 cement:6 fine sand).
15mm Cement plaster on the rough side of single or half brick wall of mix: a) 1 : 6 ( 1 cement : 6 fine sand)
6mm cement plaster to ceiling of mix. 1:3 (1 cement:3 fine sand).
Making of grooves 12mm x10mm between brick sand RCC (LMR)
Add for plaster drip course/grooves in plastered surface or moulding to R.C.C. projections
Providing and laying vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete. a) Size of tile 600x600mm.
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement and matching pigments etc. complete. a) Size of tile 600x600 mm
Kota stone slab flooring 25 mm thick over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing, polishing and curing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand) :
Providing edge moulding to 18 mm/16 mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. a) Granite Work
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying integral cement based water proofing treatment including preparation of surfaces as required for treatment of roofs, balconies, terraces etc consisting of following operations. a) Applying a slurry coat of neat cement using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over the RCC Slab including adjoining walls upto 300mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/ Brick Bats 25mm to 115mm size with 50% of Cement mortar 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge over 20mm thick layer of cement mortar of mix 1:5 (1 Cement : 5 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineerin-charge to required slope and treating similarly the adjoining walls upto 300mm height including rounding of Junctions of walls and slabs) c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/sqm of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge. d) finishing the surface with 20mm thick joint less cement mortar of mix 1:4(1 cement: 4 coarse sand) admixed with water proofing compound conforming to IS 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300mm/sq 3mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by Engineerin-charge: a) With average thickness of 120mm and minimum thickness at khurra as 65 mm
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm . This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. A) 2 mm thick
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface.
Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ liter, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. A) Two coat
Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm)
Extra for providing opening of required size and shape for wash basin/ kitchen sink in kitchen platform, vanity counters and similar location in marble/granite / stone work including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. A) In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement:3 coarse sand: 6 graded stone aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth. a) Crushed.
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately). a) Sal Wood.
Providing and fixing 30mm thick glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. A) Second class deodar wood
Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in-charge. (Cost of aluminum snap beading shall be paid in basic item.) a)With float glass panes of 8 mm thickness (weight not less than 20.0 kg / sqm)
Providing and fixing 30mm thick wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge : a) Second class deodar wood
Providing and fixing 30mm thick ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. a) With ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete. A) Fixed to openings / wooden frames with rawl plugs screws etc.
Applying priming coat: With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood)
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. A) Two or more coats on new work.
Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :
Providing and fixing aluminium tower bolts lSI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :
Providing and fixing aluminium handles lSI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete.
Providing and fixing aluminum hanging floor door stopper, ISI marked, anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : a) Twin rubber stopper
Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodized (anodic coating not less than grade AC 10 as per IS : 1868) aluminum lever handles of approved quality with necessary screws etc. complete.
Providing and fixing aluminum die cast body tubular type universal hydraulic door closer (having brand logo with IS: 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete :
Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, having brand logo embossed on the body/plate with double spring mechanism and door weight upto 125 kg for doors including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer in- plate etc. complete as per the direction of Engineer-in-charge. a) With Stainless Steel cover plate minimum 1.25 mm thickness.
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength confirming to IS:4454 part-1 and M.S. top cover of required thickness for rolling shutters. a) 80x1.25 mm M.S. laths with 1.25 mm thick top cover
Providing and fixing ball bearing for rolling shutters.
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 liter low level white P.V.C. flushing cistern, including flush pipe with manually controlled device (handle lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: a) W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : a) Stainless steel AISI-304 (18/8) Round basin 405x355 mm with single 15mm C.P. brass pillar trap
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : i) Kitchen sink without drain board a) 610x510mm bowl depth 200mm
Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour: a) Waste coupling 38mm of 83 mm length and 77 mm breadth weighing not less than 60gms.
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C waste fittings complete: i) Semi rigid pipe: a) 40 mm dia
Providing and fixing 100 mm sand cast iron grating for gully trap.
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing unplasticised- Rigid PVC pipes conforming to IS:13592 Type A including joining with seal ring conforming to IS:5382 leaving 10mm gap of thermal expansion: with necessary stays / clamps with fasteners having working pressure of 4 kg / cm2 of make Supremen or finolex only:- all complete including testing of joints and pipes for leakage etc. (Including cost / carriage of material by Mechanical transport).
50mm dia (LMR)
75mm dia (LMR)
110mm dia (LMR)
Providing and fixing unplasticised- PVC moulded fittings / accessories for unplasticised -Rigid PVC pipes conforming to IS:13592 Type A including joining with seal ring & insertion rubber washer 3 mm thick conforming to IS:5382 leaving 10mm gap of thermal expansion: with necessary stays / clamps with fasteners bolts and nuts complete; having working pressure of 4 kg / cm2 of make Supremen or finolex only:- all complete including testing of joints and pipes for leakage etc. (Including cost / carriage of material by Mechanical transport).
PVC Plain Bend 50mm dia (LMR)
PVC Plain Bend 75mm dia (LMR)
PVC Plain Bend 110mm dia (LMR)
PVC Door Bend 75mm dia (LMR)
PVC Door Bend 110mm dia (LMR)
PVC Plain TEE 50mm dia (LMR)
PVC Plain TEE 75mm dia (LMR)
PVC Plain TEE 110mm dia (LMR)
PVC DoorTEE 50mm dia (LMR)
PVC DoorTEE 75mm dia (LMR)
PVC DoorTEE 110mm dia (LMR)
PVC Reducer Door TEE 110mm x 75mm (LMR)
PVC Reducer Plain TEE 110mm x 75mm (LMR)
PVC Off Set 50mm dia (LMR)
PVC Off Set 75mm dia (LMR)
PVC Off Set 110mm dia (LMR)
PVC Coupler / Collar 50mm dia (LMR)
PVC Coupler / Collar 75mm dia (LMR)
PVC Coupler / Collar 110mm dia (LMR)
PVC Vent Cowl 110mm (LMR)
PVC Floor / Nahani Trap 110mm x 75mm (LMR)
PVC Floor / Nahani Trap 110mm x 100mm (LMR)
Providing and fixing soap dish (CP brass) with brackets, nuts & Screws complete etc. of make hindware/cera / Jaquar only: (with all carriages)
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with a minimum distance of 37 mm from wall face with concealed fittings arrangements of approved quality and colour, weighing not less than 88 gms.
Providing and fixing 15 mm nominal bore C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.
Providing and fixing 15 mm nominal bore C.P. stop cock (concealed) of standard design and of approved make conforming to IS : 8931
Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931
Providing and unplasticised PVC connection pipe with brass unions: 45cm length. A) 15mm nominal bore.
Providing and fixing 8mm dia CP / SS jet with flexible tube upto 1 metre long with SS triangular plate to Euorpean type W.C. of quality and make as approved by Engineer-in-charge.
Providing and fixing 15 mm nominal bore of standard back type C.P. brass close hole basin mixer pillar tap of approved quality and make, weighing not less than 1.970 kg.
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc.: i) Internal work-Exposed on wall :
15mm dia nominal bore (medium)
25mm dia nominal bore (medium)
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing Tee, including cutting and threading the pipe etc. complete: a) 25 to 40 mm nominal bore
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (new work) : a)25 mm nominal bore
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
Providing and fixing G.I. Tank Nipple of suitable dia of make UNIK or New or equivalent ISI marked as approved by Engineer incharge at site all complete including testing of fittings and joints for leakage etc. (Incl. carriages): a) 25mm dia nominal bore.
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete
25mm dia nominal bore
40mm dia nominal bore
Providing and fixing of stainless steel Rainwater khurra jali to be placed at roof and mumty levels of make ChILLY or CAMRY or equivalent all complete: Square or circular in shape of dia / size:( Incl. all carriages): 150mm(LMR)
Providing and fixing Electric motor pump 1.5 H.P. (Cromption /Khalsi) incl. fittings. (LMR)
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarsesand (zone- III) : 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) finished with a floatingcoat of neat cement complete as per standard design : a) Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : i) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5.
Making soak pit 2.5 m diameter 3.0 meter deep with 45x45 cm dry brick honey comb shaft with common burnt clay (non modular) bricks of class designation 7.5 bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.
Providing and fixing 60mm thick interlock precast cement concrete tiles M-30 grade over 50mm thick crusher dust or dry sand and joints to be filled by crusher dust or dry sand including watering complete job.
Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface / recessed medium class PVCconduit, with modular switch, modular plate, suitable GI boxand earthing the point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable etc. as required. a) Group A
Wiring for Circuit/Submain Wiring along with earth Wire with the following Sizes of FRLSPVC insulated copper conductor,single core Cable in surface/Recessed medium class PVC conduit as required.
2 X 2.5 SQ.MM + 1 X 2.5 SQ.MM Earth Wire
2 X 4.0 SQ.MM + 1 X 4.0 SQ.MM Earth Wire
2 X 6.0 SQ.MM + 1 X 6.0 SQ.MM Earth Wire
4 X 16.0 SQ.MM + 2 X 4.0 SQ.MM Earth Wire
4 X 4.0 SQ.MM + 2 X 4.0 SQ.MM Earth Wire
Supplying and drawing following pair 0.5 mm dia FRLS PVCinsulated annealed copper conductor, unarmored telephonecable in the existing surface/ recessed steel/ PVC conduit asrequired. A_ 2 Pair
Supplying and fixing of following sizes of medium class PVCconduit along with accessories in surface/recess includingcutting the wall and making good the same in case of recessedconduit as required.
Supplying and fixing following modular switch/ socket on theexisting modular plate & switch box including connections butexcluding modular plate etc. as required. A) Telephone socket outlet
Supplying and fixing two module stepped type electronic fanregulator on the existing modular plate switch box includingconnections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate and switch box excluding modular plate as required
Supplying and fixing suitable size GI box with modular plate andcover in front on surface or in recess, including providing andfixing 3 pin 5/6 A modular socket outlet and 5/6 A modularswitch, connections etc. as required.
Supplying and Fixing suitable size G.I box with modular plate and cover in front on surface or in recess,including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modularswitch, connection,painting etc. as required.
Extra for fixing the louvers/ shutters complete with frame for aexhaust fan of all sizes.
Supplying & fixing suitable size GI box wih modular plate andcover in front on surface or in recess including providing andfixing 25 A modular socket outlet and 25 A modular SP MCB, "C"curve including connections, painting etc. as required.
Supplying and fixing following way, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earthbar, din bar, interconnections, powder painted includingearthing etc. as required.
12 way , Double door
16 way , Double door
Supplying and fixing following way, horizontal type three poleand neutral, sheet steel, MCB distribution board, 415 V, onsurface/ recess, complete with tinned copper bus bar, neutralbus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required.
6 way (4 + 18), Double door
12 way (4 + 36), Double door
Supplying and fixing following rating, 240/415 V, 10 kA, "C"curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required.
Single Pole 6 to 32 Amp
Single pole and neutral 6 to 32 Amp
Single pole and neutral 40-63 Amp
Supplying and fixing following rating, Four pole, 415 V, 10 Ka M.C.B in the existing MCB DB complete with connections, testing and commissioning etc. as required.
40 A F.P MCB 10 Ka "C" Curve
63 A F.P MCB 10 Ka "C" Curve
Supplying and fixing single pole blanking plate in the existingMCB DB complete etc. as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminium housing with in built driver , System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. a) 40 watt LED 4 feet with min. lumen output (4000) lm
Supply installation testing and commissioning of Ceiling Fan 3 Star Rated with Voltage Range 90 V to 300 V,Min. Air Delivery 212 CMM,Service Value 5.3 Cu.m/min/watt,Aluminium Blades ,including wiring the down rods of standard length(Upto 45 cm)with 1.5 sq.mm FR PVC insulated,copper conductor,single core cable including providing and fixing phenolic laminated sheet cover on the Fan Box etc as Required. a) 1200 MM LED Street light fixture, powder coated pressure die castaluminum body (System lumen efficacy >135 lm/Watt)
Supplying, installation, Testing & Commissioning of Street light LEDfixture, powder coated pressure die cast aluminum body with built in orseparate driver as per the requirement with Driver efficiency >85%, Inputvoltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P.F.≥0.95, IP-66,IK-10, CRI >80 , under voltage and over voltage protection,EMIEMCas per CISPR-15, lenses for beam angle as per IESNA type I/II/III asper the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry) of minimum50000 Burning Hours with 70% of initial Lumen maintained till lifeends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K /4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(StandardDeviation Color Matching) <5, Maximum power consumption should notmore than the specified rating and Fixture shall be of relevant BIS standardcomplete in all respect i/c connections with 1.5 sq mm FRLS, PVCinsulated copper conductor single core cable and earthing etc. as requiredwith Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Wattoutput . LM79 & LM80 Test report from NABL lab for all testing requiredfor LED fixtures as per BIS shall be submitted. Shape size and CCT shall beas approved by Engineer-in-Charge as per requirement. (Thermalmanagement: heat sink of aluminum housing such that LED junctiontemperature shall not rise above 90°C). 120 watts
Supplying, installation, Testing & Commissioning of LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminum Body including trim 12-15 watts
Supplying and fixing of following sizes Transair exhaust fan with metal blade complete set on existing holes on wall with necessary connection from ceiling rose to fan using 2 core flexible copper wire. A) 300mm/12" sweep exhust fan
Supply installation testing and commissioning of IP:20 Aluminium Batten 10W-12 W +- 1 W LED Surface Mounted 2 ft. with system lumen efficacy of 100 lm/W and P.F >0.9 THD <20% CCT 6500K,CRI 80 .The LED should have life of 50000 Burning Hours at L70.The input voltage shall be 150 V to 270 V.The fixture should have inbuit surge protection of 2KV.Certification-LM 79 and LM 80.The test report should be from Govt. Approved Lab/inhouse NABL Lab. LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt)
Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., offollowing body material and construction as per IS : 10322 with driver as perthe requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuitprotection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified GlareRating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver& electrical circuitry), of minimum 50000 Burning Hours with, 70% of initialLumen maintained till life ends as per LM80 extrapolation IES TM-21-11report, CCT 3000°K / 4000°K / 5700°K /6000°K / 6500°K (As perANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximumpower consumption should not more than the specified rating and Fixtureshall be of relevant BIS standard and trade mark certificate ( T.C.).Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS,PVC insulated copper conductor single core cable and earthing etc. asrequired with Minimum 5 year OEM warranty. System lumen efficacy ≥105<120 lm/Watt output . LM79 & LM80 Test report from NABL lab for alltesting required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement.(Thermal management: heat sink of aluminum housing such that LEDjunction temperature shall not rise above 90°C). Powder coated die cast / Extruded aluminium Body (Thickness≥ 1.20 mm) 40 watt
SITC of Main lt Panel indoor (IP:42) free standing floor mounted dust and vermin proof compartmentalized cubical panel for electrical Works, made out of CRCA sheet. Other parameters required as per point (a) Thickness of sheet shall not be less than 1.6 mm up to 600 mm length/width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartment shaving bolted type doors with/without detachable extension type structure (b) Panel shall be duly treated for derusting in 7 tank process with de phosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/Neoprene rubber gasket of not less than 3mm thickness, required hardware, separate detachable gland plate M.S. base channel (min 75mm), hinged door with locking arrangement for equipment/switchgear c) Interconnection between bus bar and switch gears/cable shall be rigidly supported and made out by flexible copper wires (upto 125 amp) and by solid bus bar (> 125). (d) Only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator CPRI Test certificates to be submitted) All as per pre approved by Engineer in charge.
INCOMBER
100 Amp, 36 KA, FP MCCB ICU = 100% ICS
63 Amp, 36 KA, FP MCCB ICU = 100% ICS
Aluminium Bus Bar 200 Amp set of 4 strips 18"
Aluminium Bus Bar 100 Amp set of 4 strips 18"
OUTGOINGS
ON Load Change Over Switch FP 63 amp. (Front operated)
63 Amp, 36 KA, FP MCCB ICU = 100% ICS
63 Amp, 10 KA FP MCB
40 Amp, 10 KA FP MCB
63 Amp, 10 KA SPN MCB
Supplying and laying of following size DWC HDPE pipe ISI markedalong with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting,jointing etc. in the existing trench, complete as required. A) 120 mm dia (OD-120 mm & ID-103 mm nominal)
Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in groundin Existing DWC Pipe including excavation, sand cushioning, protective covering and refilling the trench etc as required.
3.5 C X 185 Sq.mm A2XFY
3.5 C X 25 Sq.mm A2XFY
Supply and Making end Termination with Brass Compression Gland and Aluminium Lugs for the Following Sizes of PVC insulated and PVC Sheathed/XLPE Aluminium Conductor Cable of 1.1 KV Grade as Required (Comet)
3½ X 185 sq. mm (57mm)
3½ X 25 sq. mm (28mm)
Supply, installation, testing and commissioning of Junction Boxes/DB-10 Pairs with Original Krone module and Back Mount Frame and have Lock -n- key, complete in all respect as per specification and desired by EIC
Supply,installation with foundation as per approved Drawing 11 Mtr SP-56 M.S Pole
Supply,installation of Structural Steel as per Standard Approved Drawing
Supply,Installation and Commissioning of 11 KV Air Break Switch(200 Amps).
Supply,Installation of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
Supply,Installation of 11 KV HG Fuse Unit .
Supply,Installation of Disc Insulator(B&S)70 KN suitable for 100 sq.mm Triple AAAC.
Supply and Installation of 100 Sq.mm AAAC Triple AAAC.
Supply,Installation of 11 KV Pin Insulator suitable for 100 sq.mm Triple AAAC.
Supply and Erection of 150 mm Dia. Heavy Class G.I Pipe for the Cable Protection.
Supply and Installation of Anti Climbing Device
Supply,Installation and Commissioning of 11 KV Meter with suitable size Out door Type combined C.T and P.T's of 15/1A Accuracy Class 0.5 S Burden 100 VA 11 KV/Root3/110 V /Root3
Supply, installation, testing and commissioning of following capacity(continuous loading) BEE 3 Star rated (Corresponding Level as per BISamended upto date of receipt of tender) , 11/0.433 KV step down, 3 Phase,50 Hz, Dyn 11 vector group, KNAN [K(K-Class insulating liquid) Natural AirNatural] copper wound transformer (Electrolytic grade 99.9% pure copper,Core made of first grade Cold Rolled Grain Oriented (CRGO) Core gradeMOH or better),Dielectric material shall be type -A, suitable for outdoor/indoor applications with On Load Tap Changer (OLTC) on HV sidehaving AVR relay and Remote Tap Changer Control (RTCC) for automaticsensing of incoming voltage, automatic operation of OLTC and facility forremote and manual operation of OLTC HV side in range of +5% to -15% insteps of 2.5%, having cable end boxes on HV side suitable for 3x300 sqmmXLPE cable of 11 KV grade, including bus trunking arrangement on LV sideincluding supplying and laying of copper conductor multicore control cablefrom transformer to HT breaker/panel for safety tripping, complete with allaccessories and safety provisions as per relevant IS 1180 (Part-3) includingfirst filling of filtered dehydrated Synthetic organic Ester oil, i/c supplying andgrouting of suitable M.S. Channel with all accessories and transformer shallbe confirming to IS : 2026 (Part 1 to Part 5), IS : 1180 (Part-3) and duly ISI Marked and as per CPWD specifications complete in all respects etc asrequired at site. The maximum flux density in any part of the core and yoke atrated voltage and frequency shall be such that the flux density with +12.5percent combined voltage and frequency variation from rated voltage andfrequency does not exceed 1.9 Tesla. The permissible temperature-rise shallnot exceed 40 dg.C for oil and 45 dg. C for winding up to 200 KVA and 45 dg.Cfor oil and 50 dg. C for winding for above 200 KVA. Inside of tank shall bepainted with varnish or liquid resistant paint. For external surfaces one coatof thermo setting powder paint or one coat of epoxy primer followed by twocoats of polyurethane base paint shall be used. IS: 1180 (Part 3) shall bereferred for paint thickness for normal to medium corrosive atmosphere. Forhighly polluted atmosphere and special application external paint work shallbe as per direction of Engineer-in-Charge. Design ambient condition : a) airtemperature 50 deg C, b) Relative Humidity 90 % Max, c) Seismic Zone asper location of site, d) Altitude as per location/site. Noise level Shall notexceed limits as per NEMA TR-1 with all accessories running measured asper IEC 551 / NEMA standard. The transformer should have QR code whichshould contain drawing, test report OEM manual, Geo- Tag of manufacturinglocation etc. Marking Each transformer shall be provided with rating platemade of anodized aluminum/ stainless steel material securely fixed on theouter body, easily accessible,as per IS: 1180 Part-3. The entries on the ratingplate shall be indelibly marked.
Supply, Installation testing and commissioning of indoor type termination kit for 3 C x 35 mm² 11 KV XLPE insulated Aluminum. conductor PVC outer sheathed armoured HT Cable with Earth (A2XFY with Earth HT Cable).(Raychem make)
Supply, Installation testing and commissioning of outdoor type termination kit for 3 C x 35 mm² 11 KV XLPE insulated Aluminum. conductor PVC outer sheathed armoured HT Cable with Earth (A2XFY with Earth HT Cable).(Raychem make) POWER AND CONTROL CABLES :-
Supplying and Laying of XLPE Insulated and PVC Sheathed Power Cable of 11KV/ 1.1 KV Grade of the following size direct in Ground including excavation,sand Cushioning,Protective Covering and Refilling the Trench as Required. a) 3 C x 35 mm² 11 KV XLPE insulated Aluminum. conductor PVC outer sheathed armoured HT Cable with Earth (A2XFY with Earth HT Cable).
Supplying,Installation,Testing and Commissioning of Copper Earthing Electrode of Size 50 x 3000mm with Copper Pipe Outer Dia. 50 mm (+-) 5 %),Length 3000 mm,Inner & and Outer Strip Size 25X6mm (Copper),Terminal Hole Two Nos.,Terminal Hole Dia. 14 mm,Seal Plate Thickness 4 mm,Base Plate Thickness 4 mm,Inner filling Material – Highly Conductive Super Crystalline Mixture,Outer filling material - Highly Hygroscopic, Non corrosive Back Fill Compound 50 Kgs.
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I.pipe from earth electrode including connection with brass nut,bolt, spring, washer excavation and re-filling etc. as required.
Supplying,Installation,Testing and Commissioning of G.I Earthing Electrode of Size 50 x 3000mm with GI Pipe Outer Dia. 58 mm (+-) 5 %,Length 3000 mm,Inner & Outer GI Strip Size 32X6mm,Terminal Hole Two Nos.,Terminal Hole Dia. 14 mm,Seal Plate Thickness 4 mm,Base Plate Thickness 4 mm,Inner filling Material – Highly Conductive Super Crystalline Mixture,Outer filling material - Highly Hygroscopic, Non corrosive Back Fill Compound 50 Kgs.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I.pipe from earth electrode including connection with G.I. nut,bolt, spring, washer excavation and re-filling etc. as required.
Carriage of material by Mechanical Transport including loading / unloading and stacking at site complete.
Sand from Hut Mashka for an av. lead of 55.00 km. by M.T.
Stone aggregate (Crusher bajree) below 40mm nominal size from Hut Mashka for an av. lead of 55.00 km. by M.T.
Stone aggregate 40mm nominal size & above from Hut Mashka for an av. lead of 55.00 km. by M.T.
Bricks from Kathua for an average lead of 170.00 Km. by M.T.
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.38 MB
MakeList.pdf
Additional Documents • 0.63 MB
BOQ_990713.xls
BOQ • 0.44 MB
Download all tender documents and submit your bid