Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.5 LAdmitted-Finance | ₹13.5 L | L1 | Admitted-Finance |
| 2 | L2₹13.5 LAdmitted-Finance | ₹13.5 L | L2 | Admitted-Finance |
| 3 | L3₹13.6 LAdmitted-Finance | ₹13.6 L | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/S MD FAREED L1 | LIBRA CONSTRUCTION AND SUPPLIERS L3 | VIGRO ENTERPRISE L2 |
|---|---|---|---|---|---|---|
| 1.01 | Comprehensive Cleaning of Indoor Unit , air filter , blower wheel & evaporator Coil using pressureized ,mild detergent and Gas Charging (R22/R32/R410) including leakage check vacuming.
(i) IGAR (N) - 07 (ii) Grn Bn (13 AR) - 05 | 12 | Job | 2,310 ₹27,720 Lowest | 2,312.5 ₹27,750 | 2,315 ₹27,780 |
| 1.02 | Inspection and tightening of electrical terminals, wiring & both Indoor and outdoor Unit Incl fixing of Capacitor (as per AC) | 12 | Job | 987 ₹11,844 | 975 ₹11,700 Lowest | 988 ₹11,856 |
| 1.03 | Functional testing of compressor, fan motor, Swing motor & thermistors sensors including verification of control panel, remote function and fixing of Printed control Bd (PCB) | 12 | Job | 1,975 ₹23,700 Lowest | 1,979.5 ₹23,754 | 1,980 ₹23,760 |
| 1.04 | Flushing and cleaning of Condenstee drainge line to prevent water leakage and foul smell and external cleaning & descaling of water inlet/outlet nozzles and safety valve | 12 | Job | 675 ₹8,100 | 675 ₹8,100 | 670 ₹8,040 Lowest |
| 1.05 | Supplying and fixing of compressor (1.5 /2 Ton Rotary type incl gas charging) | 5 | Each | 6,755 ₹33,775 Lowest | 6,755 ₹33,775 Lowest | 6,760 ₹33,800 |
| 1.06 | Supplying and fixing of Thermostate Sensors | 12 | Each | 570 ₹6,840 Lowest | 570 ₹6,840 Lowest | 575 ₹6,900 |
| 1.07 | Cleaning of inner Tank , heating elemetn and sadeiment removal including dismantling reassembly and fixing of Thermostate (manual/elctroni type as per mode) | 50 | Job | 1,000 ₹50,000 Lowest | 1,000 ₹50,000 Lowest | 1,005 ₹50,250 |
| 1.08 | Inspection and Testing of Thermostate thermal cut out Switch ,electrical connection with multimeter and fixing of Magnesium Rod | 50 | Job | 600 ₹30,000 Lowest | 605 ₹30,250 | 602.5 ₹30,125 |
| 1.09 | External cleaning and descalling of water inlet/outlet nozzles and safety valve including fixing of heating element (as per model 1500 /2000 W) | 50 | Job | 650 ₹32,500 Lowest | 650 ₹32,500 Lowest | 655 ₹32,750 |
| 1.10 | Functional Testing after maintainance (heating time, auto cut off, leakage check) | 50 | Job | 1,455 ₹72,750 | 1,450 ₹72,500 Lowest | 1,455.5 ₹72,775 |
Tender Value
₹13.5 L
EMD Value
₹27,005
Closing Date
7 Apr 2026, 4:00 pmClosed
SO-1(Wks), HQ IGAR(N)
SO-1 (Wks), HQ IGAR(North) Kohima, Nagaland PIN - 797001
Annual Maint Contract for AC (1.5/2 Ton), Geysers, Water Coolers, Solar Water Heaters, Solar Street Lights and 01 x 50 KW Roof Top Solar Power Plant for Kohima Garrison
2026_ARMHA_902604_1
VIII.11001/Engr/AMC/2025-26/02
Open Tender
Civil Works - Others
Works
245 days
HQ IGAR(N)
As per tender documents
2 documents required · 2 mandatory
₹1,000
SO-1(Works), HQ IGAR(N)
₹27,005
10 Jul 2026
14 Mar 2026
9 Apr 2026
15 Mar 2026
7 Apr 2026
15 Mar 2026
15 Mar 2026 - 25 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Comprehensive Cleaning of Indoor Unit , air filter , blower wheel & evaporator Coil using pressureized ,mild detergent and Gas Charging (R22/R32/R410) including leakage check vacuming.
(i) IGAR (N) - 07 (ii) Grn Bn (13 AR) - 05 | 12 | Job | - | - |
| 1.02 | Inspection and tightening of electrical terminals, wiring & both Indoor and outdoor Unit Incl fixing of Capacitor (as per AC) | 12 | Job | - | - |
| 1.03 | Functional testing of compressor, fan motor, Swing motor & thermistors sensors including verification of control panel, remote function and fixing of Printed control Bd (PCB) | 12 | Job | - | - |
| 1.04 | Flushing and cleaning of Condenstee drainge line to prevent water leakage and foul smell and external cleaning & descaling of water inlet/outlet nozzles and safety valve | 12 | Job | - | - |
| 1.05 | Supplying and fixing of compressor (1.5 /2 Ton Rotary type incl gas charging) | 5 | Each | - | - |
| 1.06 | Supplying and fixing of Thermostate Sensors | 12 | Each | - | - |
| 1.07 | Cleaning of inner Tank , heating elemetn and sadeiment removal including dismantling reassembly and fixing of Thermostate (manual/elctroni type as per mode) | 50 | Job | - | - |
| 1.08 | Inspection and Testing of Thermostate thermal cut out Switch ,electrical connection with multimeter and fixing of Magnesium Rod | 50 | Job | - | - |
| 1.09 | External cleaning and descalling of water inlet/outlet nozzles and safety valve including fixing of heating element (as per model 1500 /2000 W) | 50 | Job | - | - |
| 1.1 | Functional Testing after maintainance (heating time, auto cut off, leakage check) | 50 | Job | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.06 MB
BOQ_948702.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].